首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 37 毫秒
1.
The preparation of a tyrosinase biosensor based on the immobilization of the enzyme onto a glassy carbon electrode modified with electrodeposited gold nanoparticles (Tyr-nAu-GCE) is reported. The enzyme immobilized by cross-linking with glutaraldehyde retains a high bioactivity on this electrode material. Under the optimized working variables (a Au electrodeposition potential of −200 mV for 60 s, an enzyme loading of 457 U, a detection potential of −0.10 V and a 0.1 mol l−1 phosphate buffer solution of pH 7.4 as working medium) the biosensor exhibited a rapid response to the changes in the substrate concentration for all the phenolic compounds tested: phenol, catechol, caffeic acid, chlorogenic acid, gallic acid and protocatechualdehyde. A R.S.D. of 3.6% (n = 6) was obtained from the slope values of successive calibration plots for catechol with the same Tyr-nAu-GCE with no need to apply a cleaning procedure to the biosensor. The useful lifetime of one single biosensor was of at least 18 days, and a R.S.D. of 4.8% was obtained for the slope values of catechol calibration plots obtained with five different biosensors. The kinetic constants and the analytical characteristics were calculated for all the phenolic compounds tested. The Tyr-nAu-GCE was applied for the estimation of the phenolic compounds content in red and white wines. A good correlation of the results (r = 0.990) was found when they were plotted versus those obtained by using the spectrophotometric method involving the Folin-Ciocalteau reagent.  相似文献   

2.
Summary A fully integrated screening system for phenolic compounds was developed incorporating on-line solid phase extraction, fractionation and biosensor detection. Two different types of biosensors, solid graphite and carbon paste electrodes incorporating the enzyme tyrosinase, were compared and used in the screening system. Interfacing of the solid phase extraction and fractionation with the biosensor detection was given special attention since the biosensors were not compatible with the organic modifier used for desorption of phenols from the solid phase extraction step. The system was validated with conventional analytical techniques. Surface water samples from the Ebro river were spiked with 1,10, and 25g L–1 of catechol, phenol,p-cresol, respectively. Three out of seven samples were spiked and the correct samples were identified, containing phenols equivalent to the spiked concentrations.  相似文献   

3.
The challenge of analyzing beta-blocker drugs in sludge and wastewater   总被引:1,自引:0,他引:1  
In this study, different approaches were used to assess and overcome the severe effects of interference from the sample matrix from different types of sludges and wastewater on the analysis of nine beta-blockers and the beta sympathomimetic clenbuterol. The partitioning of the target compounds into sludge was investigated in wastewater treatment plants (WWTPs) in both Canada and Germany to evaluate whether this is an important mechanism for removal from sewage. Due to ion suppression in the electro spray interface, absolute recoveries were for certain compounds even lower than 20%. By using surrogate standards, acceptable relative recoveries of >75% were achieved for WWTP influents and effluents and for sludges. These matrix effects underline the need to use appropriate surrogate standards to aid in analyte quantitation. Using the developed methods, beta-blockers were detected at concentrations up to 2 μg/L in WWTP effluents, with metoprolol, sotalol, and atenolol present as the dominant compounds. Removal rates within WWTPs were highly inconsistent and ranged from 1-69%. Propranolol showed the greatest degree of partitioning into sludge with solid/water partition coefficients of one order of magnitude higher than those for all other compounds. However, even for propranolol, sorption did not contribute significantly to the overall elimination in WWTPs. It is likely that the removal of beta-blockers during waste water treatment can be attributed primarily to microbial biodegradation.  相似文献   

4.
Wastewater treatment plants dealing with industrial wastes are often susceptible to overload of toxic influent that can partially or completely destroy treatment for extended periods. An obvious candidate for monitoring toxicity in such wastewater systems is bioluminescent bacteria. However, the natural bioluminescent bacteria can be particularly sensitive to some industrial wastes and therefore their response to normal operational conditions does not reflect the status of the microbial community responsible for treatment. Moreover, the salt dependence of the marine bioluminescent bacteria, and the temperature sensitivity of some strains, further complicate their use. Here we describe the construction of whole cell genetically modified bioluminescent biosensors and their immobilisation for use in monitoring the toxicity of a complex industrial wastewater containing phenolic materials. A hand-held luminometer was designed for laboratory or field use, and the immobilisation system designed with several things in mind: the geometry of the instrument; the need for containment of GM bacteria; the maximisation of the bioavailability of the wastewater to the biosensor. The performance of a candidate GM sensor was compared with Vibrio fischeri in liquid culture and after immobilisation in thin films of poly(vinyl alcohol) (PVA) cryogels. The biosensors were tested against pure phenol and 3-chlorophenol as a reference toxic chemical known to be much more toxic to bacteria than phenol. The biosensors were then tested with the phenolics-containing industrial wastewater. The immobilisation system proved to operate predictably with pure toxicants, and was able to discriminate toxicity of various zones within the wastewater treatment plant.  相似文献   

5.
Amperometric biosensors based on a gold planar electrode and on two types of nanocomposite electrodes consisting of multi-walled carbon nanotubes for the determination of L-malic acid designed for wine-makers were developed. The biosensors designed for wine-makers were constructed by immobilization of L-malate dehydrogenase and diaphorase within chitosan layers on the surface of the electrodes. The coenzyme NAD+ and the electrochemical mediator ferricyanide were present in the measuring solution. The current resulting from re-oxidation of produced ferrocyanide was measured at a working potential of +300 mV against an Ag/AgCl reference electrode. The biosensor based on a gold electrode showed linearity over the range 10–520 μM with a detection limit of 5.41 μM. Calibration curves for biosensors utilizing nanocomposites were obtained both with the linear range of 10 to 610 μM. The detection limits were 1.57 and 1.77 μM, respectively. The biosensors showed satisfactory operational stability (no loss of sensitivity after 30 consecutive measurements) and storage stability (90% of the initial sensitivity after one year of storage at room temperature). The results obtained from measurements of wine samples were in a good correlation with the standard HPLC method. Satisfactory biosensor sensitivity, specificity and stability allowed their successful commercialization.  相似文献   

6.
Amperometric biosensors using bacterial cells were developed for the determination of phenolic compounds and the measurement was based on the respiratory activity of the cells. For this purpose, Pseudomonas putida DSM 50026 which is one of the well-known phenol degrading organisms, was used as a biological component. The cells were grown in the presence of phenol as the sole source of organic carbon. As well as phenol adapted cells, the bacterium which used the glucose as the major carbon source, was also used to obtain another type of biosensor for the comparison of the responses and specificities towards different xenobiotics. The commercial oxygen electrode was used as a transducer to test the sensor responses for both induced and non-induced cells. Our results showed that the adaptation step enable us to obtain biosensor devices with different substrate specificity. Moreover, P. putida was immobilized on the surface of thick film working electrodes made of gold by using gelatin membrane cross-linked with glutaraldehyde. The biosensors were calibrated for different phenolic substances. Furthermore, phenol detection was performed in synthetic wastewater samples.  相似文献   

7.
DNA electrochemical biosensors   总被引:4,自引:0,他引:4  
Disposable electrochemical DNA-based biosensors are reviewed; they have been used for the determination of low-molecular weight compounds with affinity for nucleic acids and for the detection of the hybridisation reaction. The first application is related to the molecular interaction between surface-linked DNA and the target pollutants or drugs, in order to develop a simple device for rapid screening of toxic or similar compounds. The determination of such compounds was measured by their effect on the oxidation signal of the guanine peak of calf thymus DNA immobilised on the electrode surface and investigated by chronopotentiometric analysis. The DNA biosensor is able to detect known intercalating compounds, such as daunomycin, polychlorinated biphenyls (PCBs), aflatoxin B1, and aromatic amines. Applicability to river and waste water samples is also demonstrated. Disposable electrochemical sensors for the detection of a specific sequence of DNA were realised by immobilising synthetic single-stranded oligonucleotides onto a graphite screen-printed electrode. The probes became hybridised with different concentrations of complementary sequences present in the sample. The hybrids formed on the electrode surface were evaluated by chronopotentiometric analysis using daunomycin as indicator of the hybridisation reaction. The hybridisation was also performed using real samples. Application to apolipoprotein E (ApoE) is described, in this case samples have to be amplified by PCR and then analysed by DNA biosensor. The extension of such procedures to samples of environmental interest or to contamination of food is discussed.  相似文献   

8.
Novel formaldehyde-sensitive conductometric biosensors have been developed that are based on commercial bacterial formaldehyde dehydrogenase (FDH) from Pseudomonas putida and recombinant formaldehyde dehydrogenase (rFDH) from the yeast Hansenula polymorpha as the bio-recognition elements. The bio-recognition membranes have mono-layer architecture and consist of enzyme cross-linked with albumin and of the cofactors NAD (for FDH-based sensor) or NAD and glutathione (for rFDH-based sensor). This architecture of the biosensor allows the determination of formaldehyde without adding NAD and glutathione to the analyzed sample at every analysis and conducting measurements on the same transducer without cofactors regeneration since the bio-membrane contains it at high concentration (100 mM for NAD and 20 mM for glutathione). The response is linear in the range from 10 to 200 mM of formaldehyde concentration depending on the enzyme used. The dependence of the biosensor output signals on pH and buffer concentration as well as operational/storage stability and selectivity/specificity of the developed conductometric biosensors have been investigated. The relative standard deviation of the intra-sensor response did not exceed 4% and 10% for rFDH- and FDH-based sensors, respectively. The relative standard deviation of the inter-sensor response constituted 20% for both dehydrogenases used. The biosensors have been validated for formaldehyde detection in some real samples of pharmaceutical (Formidron), disinfectant (Descoton forte) and an industrial product (Formalin). A good correlation does exist between the concentration values measured by the conductometric biosensor developed in this work, an enzymatic method, amperometric biosensors developed earlier, and standard analytical methods of formaldehyde determination.  相似文献   

9.
Modern tools for the analysis of cellular function aim for the quantitative measurement of all members of a given class of biological molecules. Of the analyte classes, nucleic acid measurements are typically the most tractable, both on an individual analyte basis and in parallel. Thus, tools are being sought to enable measurement of other cellular molecules using nucleic acid biosensors. Of the variety of potential nucleic acid biosensor strategies, structure-switching aptamers (SSAs) present a unique opportunity to couple sensing and readout of the target molecule. However, little has been characterized about the parameters that determine the fidelity of the signal from SSA biosensors. In this study, a small molecule biosensor based on a SSA was engineered to detect the model small molecule, theophylline, in solution. Quantitative theophylline detection over nearly three orders-of-magnitude was achieved by scintillation counting and quantitative PCR. Further analysis showed that the biosensor fidelity is primarily controlled by the relative stability of the two conformations of the SSA.  相似文献   

10.
《Electroanalysis》2004,16(16):1305-1310
A novel amperometric biosensor was constructed for the determination of phenols in pure organic phase. This biosensor was fabricated by immobilizing tyrosinase in a titania sol‐gel membrane which was obtained with a vapor deposition method. This method was facile and avoided the calcination step needed in conventional titania sol‐gel process. The titania sol‐gel membrane could effectively retain the essential water layer around the enzyme molecule needed for maintaining its activity in organic phase. The experimental parameters such as solvent and operating potential were optimized. At ?100 mV this biosensor showed a good amperometric response to phenols in pure chloroform without any mediator and rehydration of the enzyme. For catechol determination the sensor exhibited a fast response of less than 5 seconds. The sensitivity of different phenols was as follows: catechol > phenol > p‐cresol. Additionally, the apparent Michaelis‐Menten constants of the encapsulated tyrosinase to catechol, phenol and p‐cresol were found to be 0.15±0.003, 0.17±0.008 and 0.21±0.004 mM, respectively. The biosensor had also good reproducibility and stability. This work provided a promising platform for the construction of pure organic phase biosensors and the determination of substrates with poor water solubility.  相似文献   

11.
The present work describes the development and optimization of a capillary (zone) electrophoresis/mass spectrometric (CE/MS) analysis method for polar hydrophilic aromatic sulfonates (ASs). The compounds were detected by negative ion electrospray ionization (NIESI) and selected ion monitoring (SIM). In comparison with CE/UV, for CE/MS a lower-concentration volatile ammonium acetate buffer (5 mM) without organic modifier and a higher separation voltage were better suited for separation. Sensitivity of CE/MS was slightly better than for CF/UV, with the limit of detection (LOD) ranging between 0.1 and 0.4 mg l(-1). For verification of the CE/MS results, ASs were also analysed by ion-pair liquid chromatography/diode array UV detection coupled in series with electrospray mass spectrometry (IPC/DAD/ESI-MS). Real water samples of different waste water treatment plants (WWTPs) in Catalonia (NE Spain) were extracted by solid-phase extraction (SPE) with LiChrolut EN and analysed with CE/MS and LC/MS. ASs were found in influent and effluent water samples of the WWTPs in the microg l(-1) concentration range. LC/MS offered a higher separation efficiency and sensitivity than CE/MS. Therefore with LC/MS more compounds could be identified in the WWTPs. The persistency of the ASs was distinct: some compounds were well degraded during the water treatment process, while others were quite persistent.  相似文献   

12.
In the present study, a comparison between a disposable electrochemical DNA biosensor and a Vibrio fischeri-based luminescent sensor for the detection of toxicants in water samples was made.In order to realize this study, a disposable electrochemical DNA biosensor has been reported. The DNA biosensor is assembled by immobilizing double stranded Calf Thymus DNA onto the surface of a disposable carbon screen-printed electrode. The oxidation signal of the guanine base, obtained by a square wave voltammetric scan, is used as analytical signal to detect the DNA damage; the presence of low molecular weight compounds with affinity for nucleic acids is measured by their effect on the guanine oxidation peak.Wastewater samples provided during First European Interlaboratory Exercise on water toxicity in the course of the project SWIFT-WFD were analyzed, and biosensor results were compared with a currently used toxicity test ToxAlert®100 based on the bioluminescence inhibition of Vibrio fischeri. This test have been used because is rapid, easy handling and cost effectively responses for the toxicity assessment in real water samples.The results showed a promising correlation between two tests used for the detection of toxic compounds in water samples.  相似文献   

13.
Methods for measuring toxicity or respiratory activity of microbial cultures can be used as tools for assessing the impact of chemicals or waste streams on biological wastewater treatment plants. Easy-to-use and highly standardised toxicity tests are gaining wide acceptance due to their capability to make an assessment of the overall composite toxicity of the discharge. In this study we evaluate the relative sensitivity and performance of three microbial assay procedures for measuring toxicity of nine commonly used organic compounds in pharmaceutical processes: ToxAlert® (using Vibrio fischeri), CellSense biosensors (using activated sludge, Pseudomonas putida and V. fischeri sensors) and Biolog MT2 microplates (using industrial activated sludge). Results were statistically compared and characteristics of the three procedures are discussed in terms of their sensitivity, reproducibility, representativity and ease of execution. All tests were found to be easy to perform. ToxAlert® gave the best quantitative results, best reproducibility and repeatability followed by Biolog MT2. The uncertainty in the estimates for CellSense was found to be large, leading to wide confidence intervals. Although ToxAlert® gave the best quantitative results the Biolog MT2 microplates which used industrial activated sludge were found to be more representative of the microflora present in industrial biological treatment plants. The microplate respiration tests are recommended for screening large number of toxicants or wastewater samples. CellSense gave poor reproducibility, however, it is a method with potential since it uses whole cell biosensors which allow different species to be easily and quickly tested.  相似文献   

14.
A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological component immobilized in intimate contact with a transducer which converts the biochemical signal into a quantifiable electrical signal. Toxicity assessment of heavy metals using E.coli biosensors could be finished within 30 min and the 50% effective concentrations (ECso) values of four heavy metals were determined. The results shows that inhibitory effects of four heavy metals to E.coli can be ranked in a decreasing order of Hg^2+ 〉 Cu^2+ 〉 Zn^2+ 〉 Ni^2+, which accords to the results of conventional bacterial counting method. The toxicity test of organic compounds by using CellSense biosensor was also demonstrated. The CellSense biosensor with E. coli shows a good, reproducible behavior and can be used for reproducible measurements.  相似文献   

15.
Biosensors for environmental monitoring A global perspective   总被引:2,自引:0,他引:2  
The intention of this article is to reflect the advances and describe the trends on biosensors for environmental applications. Biosensors are useful analytical tools for environmental monitoring, capable of providing results in real time, simple to use, portable and cost-effective. Some examples of biosensors in advanced stage of development, which have been applied to real samples, as well as of commercial devices, are given. Biosensors designed for measurement of either specific chemicals or their biological effects, such as toxicity biosensors and endocrine effect biosensors, are discussed. This overview also addresses the support provided by public institutions for biosensor research in the USA, Japan and, especially, in Europe. Future prospects of biosensor technology, with special emphasis in the development of new sensing elements, are foreseen.  相似文献   

16.
《Electroanalysis》2003,15(22):1737-1744
A biosensor design, in which glucose oxidase and peroxidase are coimmobilized by simple physical inclusion into the bulk of graphite‐Teflon pellets, is reported for the detection of phenolic compounds. This design allows the “in situ” generation of the H2O2 needed for the enzyme reaction with the phenolic compounds, which avoids several problems detected in the performance of single peroxidase biosensors as a consequence of the presence of a high H2O2 concentration. So, a much lower surface fouling was found at the GOD‐HRP biosensor in comparison with a graphite‐Teflon‐HRP electrode, suggesting that the controlled generation of H2O2 makes more difficult the formation of polymers from the enzyme reaction products. The construction of trienzyme biosensors, in which GOD, HRP and tyrosinase were coimmobilized into the graphite‐Teflon matrix is also reported, and their performance was compared with that of GOD‐HRP bienzyme electrodes. The practical applicability of the composite multienzyme amperometric biosensors was evaluated by the estimation of the phenolic compounds content in waste waters from a refinery, and the results were compared with those obtained by using a colorimetric official method based on the reaction with 4‐aminoantipyrine.  相似文献   

17.
Toxicity assays applied to wastewater treatment   总被引:1,自引:0,他引:1  
The utility and validity of toxicity tests for monitoring of wastewater treatment have been assessed. The evaluated acute toxicity tests have been Vibrio fischeri, Selenastrum capricornotum and Daphnia magna tests. The validation studies indicated that the acute toxicity tests can be considered as high sensitivity analytical tools to detect common environmental concentrations of the pollutants at concentration levels as low as ng l−1. The toxicity tests showed to have discriminatory ability to distinguish between different degrees of toxicity, and the toxic specificity of the compounds on target organisms. Synergistic, additive or antagonistic effects were evaluated indicating the capacity of the toxicity test to assess the combined effects of chemicals in wastewaters. The reproducibility of these tests, calculated as relative standard deviation, is acceptable in the range of 5-22.3%. The application of multivariate date analysis proved that toxicity and chemical measures are complementary analytical tools for monitoring of wastewaters quality. The toxicity tests are useful analytical tools for screening of chemical analysis and as an early warning system to monitor the treatment of WWTPs. The use of single toxicity test or battery of tests is the best approach to evaluate the risk because they are reliable indices of the toxic impact of effluents in the aquatic environment. The toxicity tests were applied in the quality control of different European WWTPs.  相似文献   

18.
This paper describes the development of a new system for amperometric determination of phenolic compounds, and its application for monitoring these compounds in paper mill effluent. The method was based on a flow system, a dialysis sampler, and a laccase-based biosensor. The performance of this system was investigated with respect to pH, ionic strength, working potential, and flow-rate dependence. The biosensor showed an excellent long-term stability allowing measurements for over than 3 months. The sensitivity of laccase-based biosensor was tested for phenol, p-chlorophenol, guaiacol and chloroguaiacol; the detector presented selective measurements of micromolar concentration of these compounds. The integration of a dialysis membrane sampling in the system protected the biosensor surface from fouling and gave independence of sample conditions that commonly influence the biosensor performance. These favorable characteristics allowed its application for direct measurements in complex media with no sample pretreatment. This ability was confirmed employing this system in a continuous analysis of phenolic compounds during the remediation of paper mill effluent by ozonization process.  相似文献   

19.
A 4-vinylpyridine-divinylbenzene (VP-DVB) resin was synthesized to be used for on-line solid-phase extraction process and it was tested for a group of polar compounds. The high specific surface area and the nitrogen content of the VP-DVB sorbent increased the interactions with the polar analytes in the preconcentration process. The sorbent enabled 100 ml of water to be concentrated with recoveries higher than 70% for several polar compounds (including phenol) except for oxamyl (55%) and methomyl (43%). The method was used to analyse water samples by liquid chromatography and UV detection. Linearity was good and detection limits were 0.1-0.2 microg l(-1) for all compounds. Several tap and river water and waste water treatment plant samples were analyzed; phenol and (4-chloro-2-methyl-phenoxy)acetic acid (MCPA) were tentatively determined in some samples.  相似文献   

20.
罗碧容  万旭  邓星亮  余媛媛  谢振伟 《色谱》2016,34(5):473-480
建立了上清液直接进样-高效液相色谱-串联质谱同时测定废水中18种酚类污染物的分析方法。取5.0 mL水样置于具塞离心管中,加氨水调节pH≥12,摇匀,加入1.0 mL二氯甲烷-正己烷(2: 1, v/v)混合溶液并振摇5 min, 4000 r/min离心5 min,用玻璃针筒抽取上清液并经0.22 μ m聚四氟乙烯滤膜过滤,用甲酸调节水样pH至中性;然后采用Thermo Hypersil ODS柱(100 mm×2.1 mm, 5.0 μ m)分离,以甲醇-0.01 mol/L甲酸铵-甲酸水溶液(pH 4.0)为流动相进行梯度洗脱,流速0.2 mL/min,柱温30℃,进样10 μ L,电喷雾负离子电离(ESI-)模式、多反应监测(MRM)模式进行检测,外标法定量。18种酚类化合物的峰面积与其质量浓度在一定浓度范围内均呈良好的线性关系(r2≥0.9991),方法检出限为0.10~0.88 μ g/L。测定低、中、高加标浓度的样品,18种酚类化合物的相对标准偏差为2.5%~9.9%(n=6);火工药剂废水与石油化工废水样品中的平均加标回收率为68.7%~118%(n=3)。此方法操作简单,灵敏度高,干扰小,分析速度快,可适用于环境废水中18种酚类污染物的同时分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号