共查询到20条相似文献,搜索用时 15 毫秒
1.
Qingxiang Zhou Jingfu LiuYaqi Cai Guoguang LiuGuibin Jiang 《Microchemical Journal》2003,74(2):157-163
A method based on micro-porous membrane liquid-liquid extraction (MMLLE) enrichment and nonaqueous capillary electrophoresis (CE) separation, was established for the analysis of sulfonylurea herbicides in water samples. After MMLLE, the analyte trapped in the chloroform was treated mildly with nitrogen flow to dryness and then dissolved in 200 μl of 4 mM Tris methanol solution for CE analysis. Five sulfonylurea herbicides were separated by nonaqueous CE with Tris/acetate of methanol solution as the run buffer. MMLLE related parameters such as organic solvent used as acceptor, sample flow rate, sample pH, enrichment time, and salt effect were investigated with tribenuron methyl (TBM) as a model compound. Results showed that with a sample flow rate of 3.0 ml min−1 and an enrichment time of 20 min, the proposed method has good linear relationship over the scope of 1-15 ng ml−1 with related coefficient of R2=0.9911, and a detection limit of 0.4 ng ml−1. This method was applied to determine TBM in realworld water samples with recoveries over the range of 89-97%. 相似文献
2.
Nickolaj Jacob Petersen Henrik Jensen Steen Honoré Hansen Knut Einar Rasmussen Stig Pedersen-Bjergaard 《Journal of chromatography. A》2009,1216(9):1496-1502
Electromembrane extraction (EME) of basic drugs from 10 μL sample volumes was performed through an organic solvent (2-nitrophenyl octyl ether) immobilized as a supported liquid membrane (SLM) in the pores of a flat polypropylene membrane (25 μm thickness), and into 10 μL 10 mM HCl as the acceptor solution. The driving force for the extractions was 3–20 V d.c. potential sustained over the SLM. The influence of the membrane thickness, extraction time, and voltage was investigated, and a theory for the extraction kinetics is proposed. Pethidine, nortriptyline, methadone, haloperidol, and loperamide were extracted from pure water samples with recoveries ranging between 33% and 47% after only 5 min of operation under totally stagnant conditions. The extraction system was compatible with human urine and plasma samples and provided very efficient sample pretreatment, as acidic, neutral, and polar substances with no distribution into the organic SLM were not extracted across the membrane. Evaluation was performed for human urine, providing linearity in the range 1–20 μg/mL, and repeatability (RSD) in average within 12%. 相似文献
3.
Luke Chimuka Titus A.M. Msagati Ewa Cukrowska Hlanganani Tutu 《Journal of chromatography. A》2010,1217(16):2318-2325
The reviews cover important critical parameters that are often optimized in a supported liquid membrane extraction technique in both flat sheet and hollow fibre designs for ionizable organic molecules. Understanding of these parameters can enable one to predict the behavior of the compound before hand and thus reduce the number of optimization experiments. Moreover, less number of experiments can be also generated using statistical techniques which are now becoming more commonly used. Supported liquid membrane extraction optimal parameters such as the conditions of the pH of the acceptor and donor phases should easily be fixed from the pKa values of the compounds. Other parameters, including the polarity of the compound can help to predict the partitioning into the membrane and the behavior of the compound. The influence of parameters such as temperature on the mass transfer in supported liquid membrane depends on the design of the module, experimental design and type of mass transfer controlling the extraction process. 相似文献
4.
Separation of lignosulfonate from its aqueous solution using supported liquid membrane 总被引:2,自引:1,他引:1
Kabita Chakrabarty Prabirkumar Saha Aloke Kumar Ghoshal 《Journal of membrane science》2009,340(1-2):84-91
This paper presents an experimental and theoretical study on facilitated transport of lignosulfonate (LS) through a flat sheet supported liquid membrane using trioctylamine (TOA) as carrier and dichloroethane as diluent. The studies were carried out with various support materials and operating conditions (viz. carrier concentration, strip phase concentration, salt concentration, etc.) and their effects on the transport of LS. The results were analyzed to identify a suitable combination of support and operating condition that would yield best performance of the supported liquid membrane (SLM) in terms of fast and efficient transport of LS. The stability of the SLM was assessed in terms of loss of liquid from the pores of membrane support. The SLM is found to be stable till 10 h. Co-transport mechanism has been adopted in this work by using NaOH as the strip phase. It was observed that extraction of LS is increased with increase in concentration of NaOH up to a limiting value of 0.5 M NaOH. Difference of salt concentration between feed and strip phase considerably affect the separation process. The diffusional resistances of organic membrane (Δorg) and aqueous solution (Δaq) calculated from the permeation model, which is again a combination of three unique mechanisms viz., diffusion through a feed aqueous layer, a fast interfacial chemical reaction, and diffusion of carrier–complex through the organic membrane, are found to be 609.9 and 176.6 s cm−1, respectively. The values of the diffusion coefficient in the membrane (Dorg) and in the bulk organic phase (Dcomplex) are 1.67×10−9 and 6.68 × 10−8 m2s−1, respectively. The extraction of LS is about 90%. Nearly 43% of LS can be recovered at optimum condition. 相似文献
5.
6.
Seip KF Stigsson J Gjelstad A Balchen M Pedersen-Bjergaard S 《Journal of separation science》2011,34(23):3410-3417
A large screening of different components in the supported liquid membrane (SLM) in electromembrane extraction (EME) was performed to test the extraction efficiency on eight model peptides. Electromembrane extraction from a 500 μL acidified aqueous sample containing the model peptides in the concentration 10 μg/mL was used. Extraction time was 5 min with an electric potential of 10 V and 900 rpm agitation of the sample vial. The samples were extracted through a hollow fiber-based SLM with different compositions of organic solvents and carriers. A small volume of acidified acceptor solution (25 μL) was after extraction analyzed directly, or with some dilution, on CE or HPLC. This article has identified mono- or di-substituted phosphate groups as the prominent group of carrier molecules needed to obtain acceptable recoveries. For the organic solvents, primary alcohols and ketones have shown promise regarding recovery and reproducibility, with some differences in selectivity. A new composition of the SLM, namely 2-octanone and tridecyl phosphate (90:10 w/w) has proved to give higher extraction recoveries and lower standard deviation than SLMs previously reported in the literature. 相似文献
7.
An on-line coupled continuous flow liquid membrane extraction (CFLME) and C18 precolumn system was developed for sample preconcentration in liquid chromatography determination. After preconcentration by CFLME, which is based on the combination of continuous flow liquid–liquid extraction and supported liquid membrane, bisphenol A (BPA) was enriched in 960 μl of 1 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto a C18 analytical column for separation and detected at 220 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor, and enrichment time were optimized. The proposed method presents a detection limit of 0.03 μg l−1 (S/N=3) when 60 ml samples was enriched with an enrichment time of 30 min. Compared with C18 based column-switching procedure, this proposed procedure presents similar sample throughput and lower detection limits. The proposed method was successfully applied to determine BPA in tap water, river water, and municipal sewage effluent samples. 相似文献
8.
Kabita Chakrabarty Prabirkumar Saha Aloke Kumar Ghoshal 《Journal of membrane science》2010,346(1):37-44
This paper presents an experimental investigation on facilitated and simultaneous transport of mercury and lignosulfonate (LS) through a flat sheet supported liquid membrane (SLM) having Nylon 6,6 as support, trioctylamine (TOA) as carrier and dichloroethane as solvent. The experiments were performed at various operating conditions such as strip phase concentration, feed pH, carrier concentration and feed concentration to find the best set of parameters that would yield the maximum separation of pure mercury as well as its mixture with LS. The experiments were performed in co-transport mode using NaOH as the strip phase. It was observed that extraction of mercury as well as its mixture increases with increase in concentration of NaOH up to a certain limit 0.1 M NaOH in case of pure solution and 0.2 M NaOH in case of mixture). Feed phase pH significantly affects the mercury separation process. However, initial feed concentration does not affect the extraction process appreciably. Separation of mixture of mercury and LS behaves in a similar way as their pure solution; however the extraction is low in comparison to pure solution. The extraction of mercury from its pure solution is about 81% in 1 h. The extraction of mercury and LS from their mixture is about 52.6% and 50.2%, respectively at optimum condition and in a period of 2 h. 相似文献
9.
A continuous flow liquid membrane extraction (CFLME)-C18 precolumn-liquid chromatography system was developed for preconcentration and determination of chlorinated phenols (CPs). After preconcentration by CFLME, which is based on the combination of continuous flow liquid-liquid extraction and supported liquid membrane, CPs were enriched in 960 μl of 0.5 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto the C18 analytical column for separation and detected at 215 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor concentration were optimized. The proposed method presents detection limits of 0.02-0.09 μg l−1 (S/N=3) when 100 ml samples were enriched. The proposed method was successfully applied to determine CPs in tap water and river water samples with spiked recoveries in the range of 70-121%. 相似文献
10.
Electromembrane extraction (EME) was carried out using a novel instrumentation capable of impedometric monitoring of the system during the extraction. This instrumentation involves a classical two-electrode assembly fed by two time-resolved potential functions, the first for the extraction of analyte and the second for obtaining the impedance information. The impedometric analysis of the system was achieved by Laplace transformation of the current recorded during the extraction. It has been shown that the obtained impedance information can be converted to very useful knowledge about time dependence of double layer capacitance, kinetics of analyte depletion, total permeability of the SLM and the effect of experimental parameters on system behavior. It has also been shown that the impedance analysis is a powerful tool for the estimation of optimum experimental parameters without determination of analyte in the acceptor phase. 相似文献
11.
以含硅藻土的复合材料为支撑介质,开发了一种独特的支撑液液萃取柱;以一系列酸性、碱性和中性水溶液样品为模型化合物,结合高效液相色谱法(HPLC)对该萃取柱进行了系统评价,同时将其用于复杂基质样品的分析。结果表明: 经该支撑液液萃取柱预处理的苯甲酸、对硝基苯胺和对羟基苯甲酸甲酯水溶液的萃取回收率分别为90.6%、98.1%和97.7%,远超过对应样品经传统液液萃取法处理后的回收率(分别为71.9%、81.9%和83.9%)。对于复杂基质样品的分析,如雪碧中的防腐剂苯甲酸以及牛血清中的中性药物醋酸地塞米松、碱性药物马来酸氯苯那敏及酸性药物吲哚美辛等,样品的加标回收率均在80%和110%之间,相对标准偏差(RSD)均小于15%,符合生物样品的分析要求,且未出现传统液液萃取技术中常见的问题(如乳化现象)。所开发的支撑液液萃取柱具有快速、简单、耐受性好、易于实现自动化和高通量的特点,具有广泛的应用前景。 相似文献
12.
13.
酚类污染物是一类重要的污染物,对很多水生生物有毒,并且可通过食物链进行生物富集,因此,挥发酚的检测对环境污染控制和环境保护具有重要意义。苯酚是中国环境优先监测物中6种酚类物质之一。酚类物质的测定方法主要有气相色谱法、液相色谱法、光度法等。4-氨基安替比林(4-AAP)分光光度法是目前国际上普遍采用的标准方法,但该方法操作繁琐。如将此法应用于流动注射自动分析,虽然可以省去繁琐的操作,但废水中其它离子的干扰严重,必须进行预蒸馏才能进行测定,且检测限高,不能满足低浓度分析检测的需要。 相似文献
14.
A quantitative liquid chromatography coupled with high-resolution mass spectrometry method was developed for the determination of more than one hundred compounds belonging to a variety of veterinary drug classes in bovine milk. Salting out supported liquid extraction (SOSLE), a novel extraction and cleanup technique, was introduced to ensure high extraction efficiency and good sample cleanup. The high salt (ammonium sulfate) concentration in the aqueous donor phase permits supported liquid/liquid extraction (SLE) with a relative polar organic acceptor phase (acetonitrile). This is different from traditional SLE, in which the need for phase separation results in the selection of organic solvents with intermediate polarities (e.g., ethyl acetate or dichloromethane). Hence, SOSLE is more efficient in recovering polar analytes than conventional SLE. SOSLE was also compared to classical approaches like solid phase extraction, QuEChERS and ultra-filtration. The proposed technique resulted in extracts of equal or superior cleanliness and with higher average recoveries than those obtained with QuEChERS or SPE. The recovery (median for all compounds) was 73% for QuEChERS, 83% for SPE and 91% for SOSLE. The most significant improvements were observed for polar analytes (penicillines, quinolones and tetracyclines) which are hardly recovered by QuEChERS. The chromatographic separation and detection was based on an ultra-high-performance liquid chromatography Q-Orbitrap system (Q-Exactive plus). The developed analytical method has been validated (based on the commission decision 2002/957/EC) as required for quantitative veterinary drug methods. 相似文献
15.
Luke Chimuka Monika Michel Ewa Cukrowska Boguslaw Buszewski 《Journal of separation science》2009,32(7):1043-1050
The influence of temperature in a supported liquid membrane (SLM) extraction of triazole fungicides was investigated. The mass transfer parameters such as diffusion coefficient, flux and apparent viscosity were determined at temperatures ranging from 5 to 40°C. Increase in temperature led to an increase in diffusion coefficient and flux with a flowing acceptor solution. The apparent viscosity also decreased with an increase in temperature. However, the increase in mass transfer parameters did not result in an overall increase in extraction efficiency with a stagnant or circulation acceptor phase. Stripping of the analytes from the membrane into the acceptor phase as well as the configuration of the extraction unit could have limited the influence of temperature on mass transfer. The partition coefficient of analytes from the acceptor solution to the membrane, KA, was found to be much higher than that from the donor solution to the membrane KD, thus triazole compounds preferred to remain in the membrane even with an increased extraction temperature. 相似文献
16.
Monika Michel Luke Chimuka Tomasz Kowalkowski Ewa M. Cukrowska Bogusław Buszewski 《Journal of separation science》2013,36(5):986-991
An artificial neural network model of supported liquid membrane extraction process with a stagnant acceptor phase is proposed. Triazine herbicides and phenolic compounds were used as model compounds. The model is able to predict the compound extraction efficiency within the same family based on the octanol–water partition coefficient, water solubility, molecular mass and ionisation constant of the compound. The network uses the back‐propagation algorithm for evaluating the connection strengths representing the correlations between inputs (octanol–water partition coefficients logP, acid dissociation constant pKa, water solubility and molecular weight) and outputs (extraction efficiency in dihexyl ether and undecane as organic solvents). The model predicted results in good agreement with the experimental data and the average deviations for all the cases are found to be smaller than ±3%. Moreover, standard statistical methods were applied for exploration of relationships between studied parameters. 相似文献
17.
Tatjana M. Trtić‐Petrović Ksenija R. Kumrić Jelena S. Đorđević Goran T. Vladisavljević 《Journal of separation science》2010,33(13):2002-2009
Transport behaviour of Lu(III) across a polypropylene hollow fibre‐supported liquid membrane containing di(2‐ethylhexyl)phosphoric acid (DEHPA) in dihexyl ether as a carrier has been studied. The donor phase was LuCl3 in the buffer solution consisting of 0.2 M sodium acetate at pH 2.5–5.0. A miniaturised system with a single hollow fibre has been operated in a batch mode. The concentration of Lu(III) was determined by indirect voltammetric method using Zn–EDTA complex. The effect of pH and volume of the donor phase, DEHPA concentration in the organic (liquid membrane) phase, the time of extraction and the content of the acceptor phase on the Lu(III) extraction and stripping behaviour was investigated. The results were discussed in terms of the pertraction and removal efficiency, the memory effect and the mean flux of Lu(III). The optimal conditions for the removal of 177Lu(III) from labelled 177Lu‐radiopharmaceuticals were discussed and identified. The removal efficiency of Lu(III) greater than 99% was achieved at pH of the donor phase between 3.5 and 5.0 using DEHPA concentration in the organic phase of 0.47 M and the ratio of the donor to the acceptor phase of 182. 相似文献
18.
Saied Saeed HosseinyDavarani Hamid Reza Moazami Elham Memarian Saeed Nojavan 《Electrophoresis》2016,37(2):339-346
Electromembrane extraction (EME) of model analytes was carried out using a virtually rotating supported liquid membrane (SLM). The virtual (nonmechanical) rotating of the SLM was achieved using a novel electrode assembly including a central electrode immersed inside the lumen of the SLM and five counter electrodes surrounding the SLM. A particular electronic circuit was designed to distribute the potential among five counter electrodes in a rotating pattern. The effect of the experimental parameters on the recovery of the extraction was investigated for verapamil (VPL), trimipramine (TRP), and clomipramine (CLP) as the model analytes and 2‐ethyl hexanol as the SLM solvent. The results showed that the recovery of the extraction is a function of the angular velocity of the virtual rotation. The best results were obtained at an angular velocity of 1.83 RadS?1 (or a rotation frequency of 0.29 Hz).The optimization of the parameters gave higher recoveries up to 50% greater than those of a conventional EME method. The rotating also allowed the extraction to be carried out at shorter time (15 min) and lower voltage (200 V) with respect to the conventional extraction. The model analytes were successfully extracted from wastewater and human urine samples with recoveries ranging from 38 to 85%. The RSD of the determinations was in the range of 12.6 to 14.8%. 相似文献
19.
Planar polyamide 6 nanofibrous membrane was for the first time used in direct coupling of supported liquid membrane (SLM) extraction to CE analysis. Disposable microextraction device with the nanofibrous membrane was preassembled and stored for immediate use. The membrane in the device was impregnated with 1 µL of 1‐ethyl‐2‐nitrobenzene and the device was subsequently filled with 10 µL of acceptor solution (10 mM HCl) and 15 µL of donor solution (sample). The device was in‐line coupled to CE system for selective extraction and direct injection, separation and quantification of model basic drugs (nortriptyline, haloperidol, loperamide and papaverine) from standard saline solutions (150 mM NaCl) and from undiluted human body fluids (urine and blood plasma). Compared to standard polypropylene supporting material, the nanofibrous membrane demonstrated superior characteristics in terms of lower consumption of organic solvents, constant volumes of operational solutions, full transparency and possibility to preassemble the devices. Extraction parameters were better or comparable for the nanofibrous vs. the polypropylene membrane and the hyphenated SLM‐CE method with the nanofibrous membrane was characterized by good repeatability (RSD ≤ 11.3%), linearity (r2 ≥ 0.9953; 0.5–20 mg/L), sensitivity (LOD ≤ 0.4 mg/L) and transfer (27–126%) of the basic drugs. 相似文献
20.
Actually there is a great trend on the development of effective analytical methods for monitoring trace levels of various phenols which can indicate, among others compounds, the water quality. A simple, inexpensive supported liquid membrane (SLM) device was used in combination with commercially available capillary electrophoresis (CE) equipment for the direct determination of chlorophenols in surface water samples. The manifold was used simultaneously to extract and preconcentrate the analytes from liquid samples. In the extraction set-up, the donor phase (4 mL) was placed in the CE vial, where a micro-membrane extraction unit (MMEU) accommodating the acceptor phase (100 μL) in its lumen was immersed. The supported liquid membrane was constructed by impregnating a porous Fluoropore Teflon (PTFE) membrane with a water-immiscible organic solvent (dihexyl ether). The extraction process was optimized with regard to the pH of the donor and acceptor phases, membrane liquid, extraction time and voltage applied to the inlet or outlet vial during extraction. The chlorinated phenols pentachlorophenol (PCP), 2,3,6 trichlorophenol (TCP) and 2,6 dichlorophenol (DCP) were thus efficiently separated by CE, using tris(hydroxymethyl)aminomethane (Tris) and an NaH2PO4 solution containing 1% (v/v) methanol at pH 10.5 as running buffer. 相似文献