首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Recent developments in microcolumn liquid chromatography.   总被引:5,自引:0,他引:5  
An overview of the most recent developments in microcolumn liquid chromatography (LC) is presented. A short theoretical discussion on chromatographic dilution and extracolumn bandbroadening is given and also the recent progress and advances in column technology and instrumentation are reviewed. However, the emphasis of this review is on miniaturized sample clean-up, sample introduction techniques and on both established and more recent detection techniques for microcolumn LC. The hyphenation of miniaturized LC columns with other techniques, specifically on multidimensional chromatography and the coupling of microcolumn LC to mass spectrometry is discussed in detail. Both the on-line and automated off-line interfacing to other separation and detection techniques will also be addressed. Finally, a number of typical microcolumn LC applications are presented in order to demonstrate the potential of microcolumn LC methods in a variety of scientific areas.  相似文献   

2.
Pulsed electrochemical detection (PED) has progressed as a highly sensitive and selective detection technique following aqueous-based separation systems over the past three decades. The application of on-line pulsed potential cleaning to electrocatalytic noble metal electrodes has significantly increased the number of applications formerly achieved with conventional electrochemical (EC) detection. Electrochemical cells are easily miniaturized, providing the ability to apply detection by PED at microelectrodes and onto microchips utilizing electrophoretic separations. In addition, recent advances in PED waveforms and instrumentation have enabled the detection technique to be easily coupled with high pressure separation systems which require rapid detection to maintain separation integrity. As a result, advanced applications for the determination of carbohydrates as well as the expansion of PED for the detection of other organic aliphatic compounds have been recently accomplished. This review will focus on developments and methods utilizing PED following liquid chromatography (LC) and capillary electrophoresis (CE). Publications are reviewed in chronological order to emphasize the advancement of the detection method and the sustained relevance of its applications.  相似文献   

3.
Once a suitable stationary phase and column dimensions have been selected, the retention in liquid chromatography (LC) is traditionally adjusted by controlling the mobile phase composition. Solvent gradients enable achievement of good separation selectivity while decreasing the separation time as compared to isocratic elution. Capillary columns allow use of other programming parameters, i.e. temperature and applied electric fields, in addition to solvent gradient elution. This paper presents a review of programmed separation techniques in miniaturized LC, including retention modeling and method transfer from the conventional to micro- and capillary scales. The impact of miniaturized instrumentation on retention and the limitations of capillary LC are discussed. Special attention is focused on the gradient dwell volume effects, which are more important in micro-LC techniques than in conventional analytical LC and may cause significant increase in the time of analysis, unless special instrumentation and (or) pre-column flow-splitting is used. The influence of temperature upon retention is also discussed, and applications where the temperature has been actively used for retention control in capillary LC are included together with the instrumentation utilized. Finally the possibilities of additional selectivity control by applying an electric field over a packed capillary LC column are discussed.  相似文献   

4.
Summary Sample pretreatment is often the bottleneck of a tracelevel analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of procedures in use today for sample treatment coupled on-line to capillary gas chromatography (GC) is briefly discussed. Special attention is devoted to coupled-column techniques such as SPE-GC and LC-GC (SPE, solid-phase extraction; LC, column liquid chromatography) which are topics of much current interest, also because of their frequent use in so-called hyphenated systems.  相似文献   

5.
This work describes a system to interface either microbore or packed capillary gradient liquid chromatography (LC) to fast atom bombardment mass spectrometry (FAB-MS). The interface incorporates on-line ultraviolet detection and post-column matrix addition to enable independent optimization of both LC and FAB-MS. The glycopeptide antibiotic teicoplanin was chosen as a model system because this group of compounds places severe demands on the chromatographic separation and is difficult to analyze by FAB-MS. For both microbore and capillary LC, high-quality mass spectra of the major components in teicoplanin were obtained; however, the increased sensitivity of the capillary system allowed spectra to be obtained at low picomole concentrations. The sensitivity and ease of use make capillary LC the preferred system for use in LC-FAB-MS.  相似文献   

6.
In this study, methodology was developed for on-line and miniaturized enzymatic digestion with liquid chromatographic (LC) separation and mass spectrometric (MS) detection. A packed capillary LC-MS system was combined with on-line trypsin cleavage of a model protein, lactate dehydrogenase, to provide an efficient system for peptide mapping. The protein was injected onto an enzymatic capillary reactor and the resulting peptides were efficiently trapped on a capillary trapping column. Different trapping columns were evaluated to achieve a high binding capacity for the peptides generated in the enzyme reactor. The peptides were further eluted from the pre-column and separated on an analytical capillary column by a buffer more suitable for the following an electrospray ionisation (ESI) MS process. An important aspect of the on-line approach was the desalting of peptides performed in the trapping column to avoid detrimental signal suppression in the ESI process. The developed on-line system was finally compared to a classical digestion in solution, with reference to peptide sequence coverage and sensitivity. It was shown that the on-line system gave more than 100% higher peptide sequence coverage than traditional digestion methods.  相似文献   

7.
Miniaturized fiber-in-tube solid-phase extraction (fiber-in-tube SPE) has been developed as a solventless sample preconcentration technique for microcolumn liquid-phase separation methods. Short capillaries packed with polymer filaments were employed as the extraction tube and the preconcentration power for phthalates in aqueous solutions was studied. On the basis of the successful on-line coupling of this preconcentration method with liquid chromatography (LC), a more miniaturized extraction cartridge, which is installed in the rotor of the micro-injector, has been developed. With a modified commercially available valve, on-line coupling of this sample preconcentration method to capillary electrochromatography (CEC) was also investigated.  相似文献   

8.
A fully automated system, comprising a liquid chromatograph (LC) coupled on-line to a gas chromatograph (GC) by means of a loop interface, has been constructed for clean-up and analysis of polycyclic aromatic hydrocarbons (PAH). An autosampler was utilized for sample injection into the LC. By the use of a back-flush technique in conjunction with an ordinary analytical aminopropylsilica column, PAH could be isolated by LC: a concurrent solvent evaporation injection technique was then used for on-line transfer of the PAH fraction to the GC, where the PAH analysis was completed. Compared with ordinary off-line LC clean-up followed by GC analysis, the sensitivity has been increased by a factor of 50–100, yielding a detection limit for individual PAH of a few nanograms per sample when using flame ionization detection. Further, irreproducible losses of low molecular weight PAH as a result of solvent evaporation steps in off-line clean-up procedures have been eliminated. Reproducibility of retention times and relative peak areas is high, facilitating automatic peak identification and calculation of concentrations, and the system can thus be used for automatic sample evaluation. The total time required for clean-up and analysis is only 1.5 hours, and the demand on personnel time for the analysis of PAH has been drastically reduced. The technique has been demonstrated with samples of urban air and of used automobile engine lubricating oil.  相似文献   

9.
Summary An existing commercial refractive index detector was modified for use with microbore column LC systems. The detector utilizes the Fresnel method. The effect of band dispersion and dilution at the detector side is of extreme importance in connection with the miniaturized LC system. In the modified model the original heat-exchanger tube was removed and a stainless steel capillary was used for heat-exchanging. Gaskets having different cell volumes were also examined with respect to band broadening and sensitivity. The detection limit was 10ng for di-n-pentyl phthalate. The examples include the detection of phthalates, alcohols, n-paraffins, and kerosine.  相似文献   

10.
A comprehensive 2-D LC x LC system was developed for the separation of phenolic and flavone antioxidants, using a PEG-silica column in the first dimension and a C(18) column with porous-shell particles or a monolithic column in the second dimension. Combination of PEG and C18 or C8 stationary phase chemistries provide low selectivity correlations between the first dimension and the second dimension separation systems. This was evidenced by large differences in structural contributions to the retention by -COOH, -OH and other substituents on the basic phenol or flavone structure. Superficially porous columns with fused core particles or monolithic columns improve the resolution and speed of second dimension separation in comparison to a fully porous particle C(18) column. Increased peak capacity and high orthogonality in different 2-D setups was achieved by using gradients with matching profiles running in parallel in the two dimensions over the whole 2-D separation time range. Multi-dimensional set-up combining the LC x LC separation on-line with UV and multi-channel coulometric detection and off-line with MS/MS technique allowed positive peak identification. The Coularray software compensates for the effects of the baseline drift during the gradient elution and is compatible with parallel gradient comprehensive LC x LC technique. Furthermore, it provides significant improvement in the sensitivity and selectivity of detection in comparison to both UV and MS detection. The utility of these systems has been demonstrated in the analysis of beer samples.  相似文献   

11.
The on-line combination of comprehensive two-dimensional liquid chromatography (LC?×?LC) with the 2,2′-azino-bis(3-ethylbenzothiazoline)-6 sulphonic acid (ABTS) radical scavenging assay was investigated as a powerful method to determine the free radical scavenging activities of individual phenolics in natural products. The combination of hydrophilic interaction chromatography (HILIC) separation according to polarity and reversed-phase liquid chromatography (RP-LC) separation according to hydrophobicity is shown to provide much higher resolving power than one-dimensional separations, which, combined with on-line ABTS detection, allows the detailed characterisation of antioxidants in complex samples. Careful optimisation of the ABTS reaction conditions was required to maintain the chromatographic separation in the antioxidant detection process. Both on-line and off-line HILIC?×?RP-LC–ABTS methods were developed, with the former offering higher throughput and the latter higher resolution. Even for the fast analyses used in the second dimension of on-line HILIC?×?RP-LC, good performance for the ABTS assay was obtained. The combination of LC?×?LC separation with an on-line radical scavenging assay increases the likelihood of identifying individual radical scavenging species compared to conventional LC–ABTS assays. The applicability of the approach was demonstrated for cocoa, red grape seed and green tea phenolics.
Figure
On-line HILIC×RP-LC–ABTS analysis of cocoa proanthocyanidins  相似文献   

12.
A competitive immunoassay for neuropeptide Y (NPY) based on capillary electrophoresis (CE) with laser-induced fluorescence detection was developed utilizing polyclonal antisera as the immunoreagent and fluorescein-labeled NPY as the tracer. The assay was performed with on-line mixing of reagents, automated injections, and a 3 s separation time. The assay had a detection limit of 850 pM. To detect NPY at lower concentrations, the assay was coupled on-line to reversed-phase capillary liquid chromatography (LC). In this arrangement, 5 microL samples were preconcentrated by capillary LC and eluted by a gradient of isopropanol-containing mobile phase. The resulting chromatographic peaks were monitored by the CE immunoassay. With preconcentration, the concentration detection limit was improved to 40 microM and NPY could be measured in push-pull perfusion samples collected from the paraventricular nucleus of freely moving rats. The technique was extended to simultaneous detection of NPY and glucagon secretion from islets of Langerhans.  相似文献   

13.
The role of separation science in proteomics research.   总被引:22,自引:0,他引:22  
H J Issaq 《Electrophoresis》2001,22(17):3629-3638
In the last few years there has been an increased effort into the separation, quantification and identification of all proteins in a cell or tissue. This is a review of the role gel electrophoresis, high performance liquid chromatography (HPLC), and capillary electrophoresis (CE) play in proteomics research. The capabilities and limitations of each separation technique have been pointed out. Instrumental strategies for the resolution of cell proteins which are based on efficient separation employing either a single high-resolution procedure or a multidimensional approach on-line or off-line, and a mass spectrometer for protein identification have been reviewed. A comparison of the advantages of multi-dimensional separations such as two-dimensional polyacrylamide gel electrophoresis, HPLC-HPLC, and HPLC-CE to the separation of cell and tissue proteins are discussed. Also, a discussion of novel approaches to protein concentration, separation, detection, and quantification is given.  相似文献   

14.
Information on protein expression, disease biomarkers or surrogate markers and genetic disorders can nowadays be achieved from analysis of complex biological samples by liquid separation coupled to mass spectrometric (MS) detection. This paper describes fast multidimensional separation by on-line liquid chromatography (LC) and capillary electrophoresis (CE), followed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) MS detection. This detector provides ultrahigh resolution of the detected ions, mass accuracy at the ppm-level and high sensitivity. Most of the challenge of this system lies in the development of a new interface for the on-line coupling of LC to CE. The interface developed in poly(dimethylsiloxane) provides a RSD for injection repeatability of <3.5% and surface control for unspecific binding by deactivation with a cationic polymer, PolyE-323. We have evaluated the interface, as well as the overall system, with respect to robustness and deconvolution ability. Sequence coverage for bovine serum albumin (BSA) of 93% showed a high recovery of sample in the different transfer steps through the system. The detection limit for identification is 277 ng mL(-1) (or 280 nM) on average for peptides. In the future, we expect LC-CE-MS to be a novel strategy for elucidating the chemistry of biological matrices.  相似文献   

15.
Electrospray ionization (ESI) in combination with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry provides for mass analysis of biological molecules with unrivaled mass accuracy, resolving power and sensitivity. However, ESI FTICR MS performance with on-line separation techniques such as liquid chromatography (LC) and capillary electrophoresis has to date been limited primarily by pulsed gas assisted accumulation and the incompatibility of the associated pump-down time with the frequent ion beam sampling requirement of on-line chromatographic separation. Here we describe numerous analytical advantages that accrue by trapping ions at high pressure in the first rf-only octupole of a dual octupole ion injection system before ion transfer to the ion trap in the center of the magnet for high performance mass analysis at low pressure. The new configuration improves the duty cycle for analysis of continuously generated ions, and is thus ideally suited for on-line chromatographic applications. LC/ESI FTICR MS is demonstrated on a mixture of 500 fmol of each of three peptides. Additional improvements include a fivefold increase in signal-to-noise ratio and resolving power compared to prior methods on our instrument.  相似文献   

16.
This article reports a new procedure for the direct determination of faecal sterols coprostanol and cholesterol in wastewater samples as tracers of human sewage contamination. The method combines in-tube solid-phase microextraction (IT-SPME) for analyte enrichment and capillary liquid chromatography (LC) for separation with diode array detection for identification and quantification. A titania-based polymeric capillary column and a conventional octadecyl silica (ODS) capillary column were evaluated and compared for their ability to separate the analytes. The titania-based column allowed the separation of the analytes in much shorter chromatographic times and with better chromatographic profiles, which in turn resulted in better detectability. In addition, IT-SPME allowed the direct injection into the chromatographic system of sample volumes as large as 200 μL, thus making unnecessary off-line clean-up and concentration steps. In such a way, the tested compounds could be directly analysed in less than 10 min, the limits of detection (LODs) being 10 and 1.2 μg/L for coprostanol and cholesterol, respectively. The reliability of the proposed method was tested by processing several wastewater samples.  相似文献   

17.
Narrow-bore column liquid chromatography coupled on-line with capillary gas chromatography (LC/GC) is used for the determination of polychlorinated biphenyls (PCBs) in sediment via a heart-cutting technique. This method is compared with a method in which two off-line column clean-up steps are used with subsequent analysis by capillary gas chromatography. For the LC/GC analysis the recovery of PCBs was 90–100%. For two sediment samples from the river Meuse the LC/GC and the other, more laborious method showed good agreement.  相似文献   

18.
The use of the multidimensional detection systems, mass spectrometry and NMR, with separation techniques is discussed with a consideration of their actual or potential application in food analysis. The features of the most commonly used interfaces for coupling liquid chromatography (LC) and mass spectrometry (MS) are briefly examined and examples from the literature on the use of LC-MS in the analysis of natural components in foodstuffs are reported. The potential capabilities for food analysis of LC-NMR, supercritical fluid chromatography (SFC)-MS and capillary electrophoresis (CE)-MS are highlighted.  相似文献   

19.
A mixture of unsaturated fatty acid methyl esters was separated with a new splitless capillary set-up. With the employed apparatus configuration different capillary separation techniques such as capillary high-performance liquid chromatography (cHPLC), capillary electrochromatography (CEC) and pressurized capillary electrochromatography (pCEC) could be applied. The detection and identification of the sample compounds were accomplished by hyphenating these capillary separation techniques with nuclear magnetic resonance (NMR) spectroscopy using a novel configuration of the detection capillary set-up. Using modified electrokinetically driven separation techniques, the electric field was applied solely across the separation column. With this improved interface for capillary liquid chromatography-NMR on-line coupling, the stereochemical assignment of the cis and trans configuration of unsaturated fatty acids could be easily accomplished. Finally, the results of cHPLC-NMR, CEC-NMR and pCEC-NMR coupling experiments were compared.Dedicated to Professor Günter Häfelinger on the occasion of his 65th birthday  相似文献   

20.
The development of a simple and sensitive assay for the quantitative analysis of the marine anticancer agent Yondelis (ET-743, trabectedin) in human plasma using liquid chromatography (LC) with column switching and tandem mass spectrometric (MS/MS) detection is described. After protein precipitation with methanol, diluted extracts were injected on to a small LC column (10 x 3.0 mm i.d.) for on-line concentration and further clean-up of the sample. Next, the analyte and deuterated internal standard were back-flushed on to an analytical column for separation and subsequent detection in an API 2000 triple-quadrupole mass spectrometer. The lower limit of quantitation was 0.05 ng mL(-1) using 100 micro l of plasma with a linear dynamic range up to 2.5 ng ml(-1). Validation of the method was performed according to the most recent FDA guidelines for bioanalytical method validation. The time needed for off-line sample preparation has been reduced 10-fold compared with an existing LC/MS/MS method for ET-743 in human plasma, employing a labor-intensive solid-phase extraction procedure for sample pretreatment. The proposed column switching method was successfully applied in phase II clinical trials with Yondelis and pharmacokinetic monitoring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏