首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Artificial neural networks (ANNs) are relatively new computational tools that have found extensive utilization in solving many complex real-world problems. This paper describes how an ANN can be used to identify the spectral lines of elements. The spectral lines of Cadmium (Cd), Calcium (Ca), Iron (Fe), Lithium (Li), Mercury (Hg), Potassium (K) and Strontium (Sr) in the visible range are chosen for the investigation. One of the unique features of this technique is that it uses the whole spectrum in the visible range instead of individual spectral lines. The spectrum of a sample taken with a spectrometer contains both original peaks and spurious peaks. It is a tedious task to identify these peaks to determine the elements present in the sample. ANNs capability of retrieving original data from noisy spectrum is also explored in this paper. The importance of the need of sufficient data for training ANNs to get accurate results is also emphasized. Two networks are examined: one trained in all spectral lines and other with the persistent lines only. The network trained in all spectral lines is found to be superior in analyzing the spectrum even in a noisy environment.  相似文献   

2.
A method based on laser induced breakdown spectroscopy (LIBS) and neural networks (NNs) has been developed and applied to the identification and discrimination of specific bacteria strains (Pseudomonas aeroginosa, Escherichia coli and Salmonella typhimurium). Instant identification of the samples is achieved using a spectral library, which was obtained by analysis using a single laser pulse of representative samples and treatment by neural networks. The samples used in this study were divided into three groups, which were prepared on three different days. The results obtained allow the identification of the bacteria tested with a certainty of over 95%, and show that only a difference between the bacteria can cause identification. Single-shot measurements were sufficient for clear identification of the bacterial strains studied. The method can be developed for automatic real time, fast, reliable and robust measurements and can be packaged in portable systems for non-specialist users.  相似文献   

3.
Laser-induced breakdown spectroscopy (LIBS) has been applied to the analysis of three chromium-doped soils. Two chemometric techniques, principal components analysis (PCA) and neural networks analysis (NNA), were used to discriminate the soils on the basis of their LIBS spectra. An excellent rate of correct classification was achieved and a better ability of neural networks to cope with real-world, noisy spectra was demonstrated. Neural networks were then used for measuring chromium concentration in one of the soils. We performed a detailed optimization of the inputs of the network so as to improve its predictive performances and we studied the effect of the presence of matrix-specific information in the inputs examined. Finally the inputs of the network—the spectral intensities—were replaced by the line areas. This provided the best results with a prediction accuracy and precision of about 5% in the determination of chromium concentration and a significant reduction of the data, too. Awarded a poster prize on the occasion of the Euro-Mediterranean Symposium on Laser-induced Breakdown Spectroscopy (EMSLIBS 2005), Aachen, Germany, 6–9 September 2005.  相似文献   

4.
Multi-pulse laser induced breakdown spectroscopy (LIBS), in combination with the generalized linear correlation calibration method (GLCM), was applied to the quantitative analysis (fineness determination) of quaternary gold alloys. Accuracy and precision on the order of a few thousandths (‰) was achieved. The analytical performance is directly comparable to that of the standard cupellation method (fire assay), but provides results within minutes and is virtually non-destructive, as it consumes only a few micrograms of the sample.  相似文献   

5.
Femtosecond laser induced breakdown spectroscopy (LIBS) was used to identify the spatial resolution limitations and assess the minimal detectable mass restrictions in laser-ablation based chemical analysis. The atomic emission of sodium (Na) and potassium (K) dopants in transparent dielectric Mica matrices was studied, to find that both these elements could be detected from 450 nm diameter ablation craters, full-width-at-half-maximum (FWHM). Under optimal conditions, mass as low as 220 ag was measured, demonstrating the feasibility of using laser-ablation based chemical analysis to achieve high spatial resolution elemental analysis in real-time and at atmospheric pressure conditions.  相似文献   

6.
Laser Induced Breakdown Spectroscopy (LIBS) was applied on sediments directly under water. The aim of the research was to develop a method for measuring the sediment elemental composition, including minor elements, which could be implemented in-situ. The plasma was generated by a double-pulse, Q-Switched Nd:YAG laser operated at 1064 nm. For signal detection, both ICCD and non-gated, compact detectors were used. The major difficulties in underwater sediment analyses are related to the natural and laser induced surface roughness, and to the sample softness. The latter is responsible for the formation of particle clouds above the surface, which scatter both the laser and plasma radiation, and often results in breakdown formation above the analyzed surface. In such cases, a broad sonoluminescence emission from water, formed during the gas bubble collapse was sometimes registered. Under optimized experimental conditions, even by using a non-gated detector and single shot acquisition, it was possible to detect several minor sediment constituents, such as titanium, barium, manganese and others. A crude estimation of the Limit of Detection (LODs) for these elements was performed by underwater measurements on certified soils/sediments. Due to strong shot-to-shot fluctuations in the plasma temperature, well correlated calibration curves, aimed for quantitative analyses, could only be obtained after applying an appropriate data processing procedure. The latter selects automatically only the spectra characterized by similar plasma parameters, which are related to their continuum spectral distribution. Application of such a procedure improves the measurement accuracy also in other surroundings and on samples different from the ones analyzed here.  相似文献   

7.
Laser induced breakdown spectroscopy (LIBS) has become an analytical tool for the direct analysis of a large variety of materials in order to provide qualitative and/or quantitative information. However, there is a lack of information for LIBS analysis of agricultural and environmental samples. In this work a LIBS system has been evaluated for the determination of macronutrients (P, K, Ca, Mg) in pellets of vegetal reference materials. An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm and an Echelle spectrometer with ICCD detector. The plasma temperature was estimated by Boltzmann plots and instrumental parameters such as delay time, lens-to-sample distance and pulse energy were evaluated. Certified reference materials as well as reference materials were used for analytical calibrations of P, K, Ca, and Mg. Most results of the direct analysis of plant samples by LIBS were in reasonable agreement with those obtained by ICP OES after wet acid decomposition.  相似文献   

8.
We have performed spectroscopic analysis of the plasma generated by Nd:YAG laser irradiation of flesh and skin of fresh potatoes. From the spectra recorded with an Echelle spectrometer 11 minor elements have been identified. Their relative concentrations were estimated by comparing the measured spectra to the spectral radiance computed for a plasma in local thermal equilibrium. According the moderate plasma temperature of about 6500 K at the time of spectroscopic observation, the electrons are essentially generated by the ionization of the minor metal atoms, making plasma modeling possible although the organic elements may be out of equilibrium. Among the spectral lines selected for the analysis, the Na I 588.99 and 589.59 nm doublet was found to be partially self-absorbed allowing us to estimate the number density of sodium atoms. The value was found to agree with the number density predicted by the plasma model. As a result, the relative concentrations of the detected minor elements have been estimated for both the flesh and skin of the potatoes. Among these, aluminum and silicon were found to have relatively large mass fractions in the potato skin whereas their presence was not detected in the flesh. The present study shows that laser-induced breakdown spectroscopy is a promising tool to measure the elemental composition of fresh vegetables without any sample preparation.  相似文献   

9.
Gondal MA  Hussain T  Yamani ZH  Baig MA 《Talanta》2006,69(5):1072-1078
Laser induced breakdown spectroscopy (LIBS) was applied for the elemental analysis of Arabian crude oil residue samples. The spectra due to trace elements such as Ca, Fe, Mg, Cu, Zn, Na, Ni, K and Mo were recorded using this technique. The dependence of time delay and laser beam energy on the elemental spectra was also investigated. Prior to quantitative analysis, the LIBS system was calibrated using standard samples containing these trace elements. The results achieved through this method were compared with conventional technique like inductively coupled plasma.  相似文献   

10.
Laser-induced breakdown spectroscopy (LIBS) has been investigated for the discrimination of automobile paint samples. Paint samples from automobiles of different makes, models, and years were collected and separated into sets based on the color, presence or absence of effect pigments and the number of paint layers. Twelve LIBS spectra were obtained for each paint sample, each an average of a five single shot “drill down” spectra from consecutive laser ablations in the same spot on the sample. Analyses by a nonparametric permutation test and a parametric Wald test were performed to determine the extent of discrimination within each set of paint samples. The discrimination power and Type I error were assessed for each data analysis method. Conversion of the spectral intensity to a log-scale (base 10) resulted in a higher overall discrimination power while observing the same significance level. Working on the log-scale, the nonparametric permutation tests gave an overall 89.83% discrimination power with a size of Type I error being 4.44% at the nominal significance level of 5%. White paint samples, as a group, were the most difficult to differentiate with the power being only 86.56% followed by 95.83% for black paint samples. Parametric analysis of the data set produced lower discrimination (85.17%) with 3.33% Type I errors, which is not recommended for both theoretical and practical considerations. The nonparametric testing method is applicable across many analytical comparisons, with the specific application described here being the pairwise comparison of automotive paint samples.  相似文献   

11.
We report on the development and implementation of analytical methodology for investigating elemental accumulation in different layers within plant leaves, with in-situ spatial resolution mapping, exploiting the technique of LIBS. The spectrochemical analysis of lead-doped leaf samples is demonstrated to develop a real time identification procedure in order to complement other analytical techniques not lending themselves for spatial resolution analysis. Our findings suggest that with elevated levels of Pb within the plants transportation and storage of some nutrition elements is changed.  相似文献   

12.
The problem of finding new methods for the analysis of precious alloys has stimulated, in recent years, a number of different proposals for improving the analytical procedures introducing more robust calibration (or calibration-free) methods. In the paper “Accurate quantitative analysis of gold alloys using multi-pulse laser-induced breakdown spectroscopy and a correlation-based calibration method” by G. Galbács, N.Jedinski, G.Cseh, Z. Galbács and L. Túri [Spectrochimica Acta Part B, Volume 63, Issue 5, 591–597 (May 2008)] the authors proposed the use of multiple-pulse LIBS and a correlation-based method for building calibration curves for quantitative analysis of gold alloys. The method is proposed for gold alloys prepared using a fixed proportion of the alloying element. The general case where the relative concentration of the elements of the matrix is not a priori known is not discussed in the paper. In this communication, we will demonstrate that the method proposed is extremely fragile against matrix effects, and therefore cannot be usefully applied for the purpose of actual analytical measurements on gold alloys without a previous knowledge of the matrix composition.  相似文献   

13.
Cadmium is known to be a toxic agent that accumulates in the living organisms and present high toxicity potential over lifetime. Efforts towards the development of methods for microanalysis of environmental samples, including the determination of this element by graphite furnace atomic absorption spectrometry (GFAAS), inductively coupled plasma optical emission spectrometry (ICP OES), and inductively coupled plasma-mass spectrometry (ICP-MS) techniques, have been increasing. Laser induced breakdown spectroscopy (LIBS) is an emerging technique dedicated to microanalysis and there is a lack of information dealing with the determination of cadmium. The aim of this work is to demonstrate the feasibility of LIBS for cadmium detection in soils. The experimental setup was designed using a laser Q-switched (Nd:YAG, 10 Hz, λ = 1064 nm) and the emission signals were collimated by lenses into an optical fiber coupled to a high-resolution intensified charge-coupled device (ICCD)-echelle spectrometer. Samples were cryogenically ground and thereafter pelletized before LIBS analysis. Best results were achieved by exploring a test portion (i.e. sampling spots) with larger surface area, which contributes to diminish the uncertainty due to element specific microheterogeneity. Calibration curves for cadmium determination were achieved using certified reference materials. The metrological figures of merit indicate that LIBS can be recommended for screening of cadmium contamination in soils.  相似文献   

14.
The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown in recent years its great potential for rapid qualitative analysis of materials. Thanks to the possibility to implement a portable instrument that perform LIBS analysis, this technique is revealed to be particularly useful for in situ analysis in the field of cultural heritages. The purpose of this work is to evaluate the potentiality of LIBS technique in the field of cultural heritages, with respect to the chemical characterization of complex matrix as calcareous and refractory materials for further quantitative analyses on cultural heritages. X-Ray Fluorescence (XRF) analyses were used as reference. Calibration curves of certified materials used as standards were obtained by XRF analyses. The LIBS measurements were performed with a new mobile instrument called Modì (Mobile Double pulse Instrument for LIBS Analysis). The XRF analyses were performed with a portable instrument ArtTAX. LIBS and XRF measurement were performed on both reference materials and samples (bricks and mortars) sampled in the ancient Greek–Roman Theatre of Taormina. Although LIBS measurements performed on reference materials have shown non linear response to concentrations, and so we were not able to obtain quantitative results, an integrated study of XRF and LIBS signals permitted us to distinguish among chemical features and degradation state of measured building materials.  相似文献   

15.
A simultaneous optimization strategy based on a neuro-genetic approach is proposed for selection of laser induced breakdown spectroscopy operational conditions for the simultaneous determination of macro-nutrients (Ca, Mg and P), micro-nutrients (B, Cu, Fe, Mn and Zn), Al and Si in plant samples. A laser induced breakdown spectroscopy system equipped with a 10 Hz Q-switched Nd:YAG laser (12 ns, 532 nm, 140 mJ) and an Echelle spectrometer with intensified coupled-charge device was used. Integration time gate, delay time, amplification gain and number of pulses were optimized. Pellets of spinach leaves (NIST 1570a) were employed as laboratory samples. In order to find a model that could correlate laser induced breakdown spectroscopy operational conditions with compromised high peak areas of all elements simultaneously, a Bayesian Regularized Artificial Neural Network approach was employed. Subsequently, a genetic algorithm was applied to find optimal conditions for the neural network model, in an approach called neuro-genetic. A single laser induced breakdown spectroscopy working condition that maximizes peak areas of all elements simultaneously, was obtained with the following optimized parameters: 9.0 µs integration time gate, 1.1 µs delay time, 225 (a.u.) amplification gain and 30 accumulated laser pulses. The proposed approach is a useful and a suitable tool for the optimization process of such a complex analytical problem.  相似文献   

16.
17.
Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils.  相似文献   

18.
During Laser-Induced Breakdown Spectroscopy (LIBS) analysis of white lead pigment (basic lead carbonate, 2PbCO3·Pb(OH)2), used in wall paintings of historical interest, a yellow–brown discoloration has been observed around the crater. This phenomenon faded after a few days exposure under ambient atmosphere. It was established that the mechanism of this discoloration consists in lead oxides (PbO) formation. It was verified by further experiments under argon atmosphere that recombination of lead with oxygen in the plasma plume produces the oxides, which settle around the crater and induce this discoloration. The impact of discoloration on the artwork's aesthetic aspect and the role of atmosphere on discoloration attenuation are discussed. The mechanism is studied on three other pigments (malachite, Prussian blue and ultramarine blue) and threshold for discoloration occurrence is estimated.  相似文献   

19.
In this work we compare the analytical results obtained by traditional calibration curves (CC) and multivariate Partial Least Squares (PLS) algorithm when applied to the LIBS spectra obtained from ten brass samples (nine standards of known composition and one ‘unknown’). Both major (Cu and Zn) and trace (Sn, Pb, Fe) elements in the sample matrix were analyzed. After the analysis, the composition of the ‘unknown’ sample, measured by X-ray Fluorescence (XRF) technique, was revealed. The predicted concentrations of major elements obtained by rapid PLS algorithms are in very good agreement with the nominal concentrations, as well as with those obtained by the more time-consuming CC approach. A discussion about the possible effects leading to discrepancies of the results is reported. The results of this study open encouraging perspectives towards the development of cheap LIBS instrumentation which would be capable, despite the limitations of the experimental apparatus, to perform fast and precise quantitative analysis on complex samples.  相似文献   

20.
Laser induced breakdown spectroscopy (LIBS) has been evaluated for the determination of micronutrients (B, Cu, Fe, Mn and Zn) in pellets of plant materials, using NIST, BCR and GBW biological certified reference materials for analytical calibration. Pellets of approximately 2 mm thick and 15 mm diameter were prepared by transferring 0.5 g of powdered material to a 15 mm die set and applying 8.0 tons cm− 2. An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm (200 mJ per pulse, 10 Hz) and an Echelle spectrometer with ICCD detector. Repeatability precision varied from 4 to 30% from measurements obtained in 10 different positions (8 laser shots per test portion) in the same sample pellet. Limits of detection were appropriate for routine analysis of plant materials and were 2.2 mg kg− 1 B, 3.0 mg kg− 1 Cu, 3.6 mg kg− 1 Fe, 1.8 mg kg− 1 Mn and 1.2 mg kg− 1 Zn. Analysis of different plant samples were carried out by LIBS and results were compared with those obtained by ICP OES after wet acid decomposition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号