首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel microwave-assisted wet-acid decomposition method for the multi-element analysis of glass samples using inductively coupled plasma atomic emission spectrometry (ICP-AES) was developed and optimized. The SRM 621 standard reference glass material was used for this purpose, because it has similar composition with either archaeological glass specimens or common modern glasses. For the main constituents of SRM 621 (Ca, Na, Al, Fe, Mg, Ba and Ti), quality control data are given for all the examined procedures. The chemical and instrumental parameters of the method were thoroughly optimized. Thirteen acid mixtures of hydrochloric, nitric, and hydrofluoric acids in relation to two different microwave programs were examined in order to establish the most efficient protocol for the determination of metals in glass matrix. For both microwave programs, an intermediate step was employed with addition of H3BO3 in order to compensate the effect of HF, which was used in all protocols. The suitability of the investigated protocols was evaluated for major (Ca, Na, Al), and minor (Fe, Mg, Ba, Ti, Mn, Cu, Sb, Co, Pb) glass constituents. The analytes were determined using multi-element matrix matched standard solutions. The analytical data matrix was processed chemometrically in order to evaluate the examined protocols in terms of their accuracy, precision and sensitivity, and eventually select the most efficient method for ancient glass. ICP-AES parameters such as spectral line, RF power and sample flow rate were optimized using the proposed protocol. Finally, the optimum method was successfully applied to the analysis of a number of ancient glass fragments.  相似文献   

2.
本文引入微波技术消解聚合物塑料样品,使用电感耦合等离子体原子发射光谱仪(ICP-AES)测定聚合物中的铅(Pb)和镉(Cd)含量,并建立了优化的样品消解程序和测定方法,得到满意的测定结果。[摘要应包括目的、方法、结果、结论,请修改,同时修改英文]该方法具有效率高、污染小的优点。检测结果具有良好的精密度。  相似文献   

3.
A background correction method based on wavelet transform was devised and applied to inductively coupled plasma atomic emission spectrometry (ICP-AES). The proposed approach separated background from analyte signal according to their different frequencies. Compared with the analyte signal, the background has a low frequency. By removal of the components attributed to the signal, the background over the spectral window of the analyte line can be fitted through wavelet reconstruction. The results showed that the wavelet transform technique could handle all kinds of background and low signal-to-background ratio spectra, and required no prior knowledge about the sample composition, no selection of suitable background correction points, and no mathematical assumption of the background distribution. This technique performed as well as the conventional three-point background correction method for linear backgrounds, and provided better results than the latter for curved backgrounds. The proposed procedure was illustrated, by processing real spectra, to be an effective and practical tool for background correction in ICP-AES.  相似文献   

4.
A method for the determination of silicon by inductively coupled plasma atomic emission spectrometry (ICP-AES) is described. The procedure is based on a discontinuous generation of volatile silicon tetrafluoride in concentrated sulphuric acid medium after injecting 125 μl of 0.1%, w/v sodium fluoride solution into 100 μl of the sample. The gaseous silicon tetrafluoride is fed directly into the ICP torch by a flow of 250 ml min−1 Ar carrier gas. The calibration curve was linear up to at least 100 μg ml−1 of Si(IV) and the absolute detection limit was 9.8 ng working with a solution volume of 100 μl. The relative standard deviation for six measurements of 10 μg ml−1 of Si(IV) was 2.32%. The method was applied to the determination of silicon in water and iron ores.  相似文献   

5.
Fly ash samples of cement works were analysed using slurry nebulization inductively coupled plasma atomic emission spectrometric (ICP-AES). Because of the influence of the experimental factors on the signal intensity, the optimal conditions of the analysis circumstances were determined. Control analyses (wet digestion followed by ICP-AES, and XRF of dry powders (pressed pellets)) were also carried out to compare the results. Based on the result, it was concluded that the slurry nebulization method using slurry standard of same type reference material for calibration can be applied for rapid but less precise (RSD 5–10%) determination of the elements in fly ash.  相似文献   

6.
ICP-AES 法测定硅铁中痕量元素   总被引:1,自引:0,他引:1  
艾军 《分析试验室》2001,20(5):51-53
采用电感耦合等离子原子发射光谱法测定硅铁中的痕量元素,研究了 Fe 基体对被测元素的影响,并选择了最佳工作条件.被测元素的检测限为 0 .60~76.2 ng/mL,样品加标回收率为 92%~108%,RSD(n=8)<3%.  相似文献   

7.
为了填补现有方法的技术空白,本方法采用微波消解和电感耦合等离子体原子发射光谱法( ICP-AES)相结合,实现对含铜污泥中铅、锌、铬、镉、砷、镁、铝、锑量的同时测定。首先采用盐酸-硝酸-氢氟酸微波消解进行样品的前处理,消解后加入高氯酸置于电热板进行除碳并赶酸,溶样效果理想,且有效避免了高温溶样对易挥发元素砷、锑的损失,整个过程安全、高效、无损。溶样后以电感耦合等离子体发射光谱法( ICP-AES)进行测定。对含铜污泥的分解方法进行了合理选择,并对测定时的元素分析谱线及各测定元素间干扰情况等进行了讨论。该方法的加标回收率在95.31%~107.28%%,相对标准偏差(RSD)在0.31%~2.05%之间(n=7),结果表明,该方法准确度高,操作简单快捷,可同时测定多种元素,能满足批量的测定含铜污泥中铅、锌、镍、铁、镉、铬、砷、锑含量的测定要求。  相似文献   

8.
建立电感耦合等离子体原子发射光谱法测定高温合金中低含量钇的方法。采用盐酸、硝酸、氢氟酸溶解样品,在优化的仪器条件下,采用基体匹配法配制系列标准工作溶液,选择分析线为360.073 nm。钇的含量在0.0005%~0.050%范围内与光谱强度具有良好的线性关系,相关系数为0.99999,检出限为0.000003%。该方法测定结果的相对标准偏差不大于6.0%(n=8),加标回收率为90.0%~104.0%。该方法简便、快速、准确,可用于高温合金中低含量钇的测定。  相似文献   

9.
新及再生铬矿砂经1000℃灼烧,研磨,以过氧化钠为熔剂,经高温熔融,热水洗涤,盐酸、硝酸酸化前处理样品,直接用电感耦合等离子体发射光谱法测定铬矿砂中的二氧化硅。试验了熔融试样时引入的基体元素钠对被测元素的干扰情况,结果表明,过氧化钠加入为1.5克对检测干扰影响小。采用加基体铬、铁有效克服了基体效应对结果影响。硅的检出限为0.0049 mg/L, 二氧化硅测定范围为0.010%~6.0%。对铬矿砂标准物质进行测定,结果与标准值一致,方法精密度(RSD,n=10)小于1%。常规重量方法步骤繁琐、耗时长、工作量大的不足。本检测方法大大提高了检测效率,满足生产需要。  相似文献   

10.
In Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), it has been observed that the emission intensity of some atomic lines is enhanced or depressed by the presence of carbon in the matrix. The goal of this work was to investigate the origin and magnitude of the carbon-related matrix effects in ICP-AES. To this end, the influence of the carbon concentration and source (i.e. glycerol, citric acid and potassium hydrogen phthalate), the experimental conditions and sample introduction system on the aerosol characteristics and transport, plasma excitation conditions and the emission intensity of several atomic and ionic lines of a total of 15 elements has been studied. Results indicate that carbon related matrix effects do not depend on the carbon source and they become more severe when the amount of carbon loaded into the plasma increases, i.e., when using: (i) carbon concentrations higher than 5 g L− 1; (ii) high sample uptake rates; and (iii) efficient sample introduction systems. Thus, when introducing carbon into the plasma, the emission intensity of atomic lines with excitation energies below 6 eV is depressed (up to 15%) whereas the emission intensity of atomic lines of higher excitation energies (i.e. As and Se) are enhanced (up to 30%). The emission intensity of the ionic lines is not affected by the presence of carbon. The origin of the carbon-related interferences on the emission intensity of atomic lines is related to changes in the line excitation mechanism since the carbon containing solutions show the same aerosol characteristics and transport efficiencies as the corresponding aqueous solutions. Based on the previous findings, a calibration approach for the accurate determination of Se in a Se-enriched yeast certified material (SELM-1) has been proposed.  相似文献   

11.
The use of hydride generation coupled with axial view inductively couple plasma atomic emission spectrometry was presented for the determination of selenium in plant samples. The chemical factors affecting potentially the hydride generation efficiency (hydrochloric acid, sodium borohydride and sodium hydroxide concentrations) were assessed through investigation of chemical interference, accuracy and repeatability. The accuracy of measurements was not affected by elements present in high concentration in the plant matrix (K, Ca, Mg, and P). No interference was also observed with transition metals. Using a real sample (maize) with standard additions, decreases of recoveries were sometimes observed for 0.1% (m/v) NaOH, and attained 13.8% in the most unfavourable case. The final accuracy of the method was verified by using two certified reference materials: CRM 402 (white clover) and CRM 279 (sea lettuce). No statistically significant differences were obtained between the measured concentrations and the certified values. The optimized method was found sensitive (detection limit 0.15 μg l−1), reliable and repeatable (R.S.D. between 1.3% and 4.0%).  相似文献   

12.
An inductively coupled plasma atomic emission spectrometry (ICP-AES) procedure has been developed and examined for the determination of boron content (0.01 up to about 2% B) in boron-alloyed steels such as POLDI ATA BOR (65% Fe, 19%Cr, 12% Ni, 1.5% Mn, 1% B), POLDI ATA BOR EXTRA (62% Fe, 18% Cr, 13% Ni, 2.5% Mo, 1.5% Mn, 1% B) and POLDI ATA BOR-R (75% Fe, 18% Cr, 3.5% Ti, 1.8% B). The steel sample is dissolved with a mixture of hydrochloric, nitric, sulfuric and phosphoric acids in a quartz vessel. Borides of alloyed metals, especially of iron and chromium, are quantitatively decomposed. The presence of phosphoric acid in a sample solution reduces the volatility of boric acid with water vapour.Presented in part at the 1989 European Winter Conference on Plasma Spectrochemistry, Reutte, Austria  相似文献   

13.
Regional variations in arterial concentrations of Ca, Mg and Fe may influence susceptibility to atherosclerosis. However, investigation of such hypotheses requires the availability of a sensitive, reliable method for the determination of elements in small arterial samples. These biologically important elements are determined in rabbit arteries by inductively coupled plasma atomic emission spectrometry (ICP-AES). Arterial samples (aorta and iliac arteries) are collected from 4- and 6- to 7-month-old rabbits fed rabbit chow. Closed-vessel microwave acid digestion is used to prepare the samples. The accuracy of the method is tested with a NIST bovine liver (1577b) standard reference material, and the amount of each metal found is within the reported uncertainty in the certified concentration. Also, the recovery from artery samples spiked with 0.5 μg of each metal is nearly 100% (96-105% Ca, 93-105% Fe, and 92-104% Mg). The simultaneous multielement detection of Ca, Fe and Mg at levels more than 1000-fold higher than the detection limit, in arterial samples weighing as little as 5 mg, suggests that this method may be applicable to very small clinical samples or arterial samples from very small animals.  相似文献   

14.
Pohl P  Prusisz B  Zyrnicki W 《Talanta》2005,67(1):155-161
Metalfix Chelamine chelating resins of two different bead sizes (150-300 and 40-80 μm) were examined and compared regarding their application for sorption of Au, Ir, Pd, Pt, Rh and Ru ions from medium of HCl, HNO3 and mixtures of HCl and HNO3. The quantitative enrichment of Au, Ir, Pd and Pt was established for the resin of 150-300 μm particle size and for solutions acidified with HCl and HNO3 (3:1) up to the concentration of 0.50 mol l−1. In the case of Rh and Ru, the uptake of these metals by the resin was lower than 50%. For the elution, solutions of different reagents, i.e. HCl, HNO3, KCN, KI, KSCN and (NH2)2CS, were studied with respect to the complete release of the analytes retained by the resin. In addition, influence of various base metals, i.e. Al, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn, on the retention of the noble metals was investigated. Under the selected conditions for the retention and elution of Au, Ir, Pd and Pt, the analytical performance of the proposed pre-concentration procedure was evaluated and it was applied to the determination of these noble metals in anodic sludge sample.  相似文献   

15.
建立电感耦合等离子体发射光谱(ICP-AES)法测定高纯铝中硅元素的分析方法。样品采用碱溶法进行预处理,以氢氧化钠溶液溶解,再加入盐酸、硝酸酸化。选取了硅251.611 nm分析谱线进行分析。硅的质量分数在0.001%~0.01%范围内与光谱强度具有良好的线性关系,线性相关系数为0.9991。该方法检出限为0.00012%,测定结果的相对标准偏差不大于10.2%(n=8),加标回收率为93.2%~104.2%。该方法操作简便,测定结果准确、可靠,适用于快速检测高纯铝中硅元素,具有推广价值。  相似文献   

16.
建立微波消解样品,电感耦合等离子体发射光谱法测定二硼化锆中26种杂质元素含量的方法。根据二硼化锆的化学组成对杂质检测的影响,确定了各元素最佳分析线;通过考察不同浓度的锆基体对待测元素的影响来确定最佳锆基体浓度;通过萃取法分离硼元素,消除硼对杂质检测的干扰;采用基体匹配法、多谱拟和技术消除了锆基体的干扰。在选定的仪器工作条件下,各待测元素的质量浓度与信号强度成良好的线性关系,线性相关系数均大于0.999。测定结果的相对标准偏差不大于6%(n=11),样品加标回收率为94%~101%。该方法操作简便,测定结果准确,可用于二硼化锆中26种杂质元素的测定。  相似文献   

17.
建立电感耦合等离子体原子发射光谱法(ICP-AES)测定钛合金中锆元素的含量。采用盐酸-氢氟酸-硝酸溶解钛合金样品,选择357.247 nm为锆的分析谱线,通过基体匹配法消除基体钛的干扰,以电感耦合等离子体原子发射光谱法测定钛合金中锆的含量。锆的质量分数在0%~0.4%范围内与光谱强度呈良好的线性关系,相关系数大于0.999,定量下限为0.21%。测定结果的相对标准偏差小于2%(n=11),样品加标回收率为99.0%~102.7%。该方法快速、准确,能够满足实际生产中钛合金样品的测定要求。  相似文献   

18.
A novel method for the determination of trace elements in microliter samples using the tantalum filament electrothermal vaporization/low-pressure inductively coupled plasma (ETV/LP-ICP) atomic emission spectrometry has been developed. An improved tantalum filament ETV was directly coupled with LP-ICP system for efficient vaporization of microliter samples and further quantitative analysis. The experimental parameters including ETV current, rf power and mass flow rate of argon carrier gas were optimized using the copper emission signal produced by 5 μl of standard solution (5 μg/ml). Under the optimized condition, the analytical performances including linearity, precision and detection limit for the developed system were investigated. Absolute detection limits in the range of 22–391 pg for selected eight elements (Fe, Cu, Cr, Mn, Pb, K, Zn and Mg) were obtained with satisfactory precision (<8.9% RSD). The feasibility of the developed system has been demonstrated by analyzing wheat gluten NIST standard sample.  相似文献   

19.
A rapid sample preparation method is proposed for decomposition of milk powder, corn bran, bovine and fish tissues, containing certified contents of the analytes. The procedure involves sample combustion in a commercial stainless steel oxygen bomb operating at 25 bar. Most of the samples were decomposed within 5 min. Diluted nitric acid or water-soluble tertiary amines 10% v/v were used as absorption solutions. Calcium, Cu, K, Mg, Na, P, S and Zn were recovered with the bomb washings and determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Ethanol mixed with paraffin was used as a combustion aid to allow complete combustion. A cooling step prior releasing of the bomb valve was employed to increase the efficiency of sample combustion. Iodine was also determined in milk samples spiked with potassium iodide to evaluate the volatilization and collection of iodine in amine CFA-C medium and the feasibility of its determination by ICP-OES with axial view configuration. Most of the element recoveries in the samples were between 91 and 105% and the certified and found contents exhibited a fair agreement at a 95% confidence level.  相似文献   

20.
In order to determine trace amounts of phosphorus in geological and cosmochemical rock samples, simple as well as reliable analytical schemes using an ICP-AES instrument were investigated. A (conventional) ICP-AES procedure could determine phosphorus contents at the level of several 100 μg g−1 with a reasonable reproducibility (<10% for 200 μg g−1; 1σ). An ICP-AES procedure coupled with matrix-separation using cation and anion exchange resins could lower the quantification level down to 1 μg g−1 or even lower under the present experimental conditions. The matrix-separation ICP-AES procedure developed in this study was applied to twenty-one geological reference samples issued by Geological Survey of Japan. Obtained values vary from 1250 μg g−1 for JB-3 (basalt) to 2.07 μg g−1 for JCt-1 (carbonate). Matrix-separation ICP-AES yielded reasonable reproducibility (less than 8.3%; 1σ) of three replicate analyses for all the samples analyzed. In comparison of our data with certificate values as well as literature or reported values, there appear to be an apparent (and large) discrepancy between our values and certificate/reported values regardless of phosphorus contents. Based on the reproducibility of our data and the analytical capability of the matrix-separation ICP-AES procedure developed in this study (in terms of quantification limit, recovery, selectivity of an analyte through pre-concentration process, etc.), it is concluded that certified values for several reference standard rocks should be reevaluated and revised accordingly. It may be further pointed that some phosphorus data reported in literatures should be critically evaluated when they are to be referred in later publications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号