首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
Silica gel chemically bonded with aminothioamidoanthraquinone was synthesized and characterized. The metal sorption properties of modified silica were studied towards Pb(II), Cu(II), Ni(II), Co(II) and Cd(II). The determination of metal ions was carried out on FAAS. For batch method, the optimum pH ranges for Pb(II), Cu(II) and Cd(II) extraction were ≥3 but for Ni(II) and Co(II) extraction were ≥4. The contact times to reach the equilibrium were less than 10 min. The adsorption isotherm fitted the Langmuir's model showed the maximum sorption capacities of 0.56, 0.30, 0.15, 0.12 and 0.067 mmol/g for Pb(II), Cu(II), Ni(II), Co(II) and Cd(II), respectively. In the flow system, a column packed modified silica at 20 mg for Pb(II) and Cu(II), 50 mg for Cd(II), 60 mg for Co(II), Ni(II) was studied at a flow rate of 4 and 2.5 mL/min for Ni(II). The sorbed metals were quantitatively eluted by 1% HNO3. No interference from Na+, K+, Mg2+, Ca2+, Cl and SO42− at 10, 100 and 1000 mg/L was observed. The application of this modified silica gel to preconcentration of pond water, tap water and drinking water gave high accuracy and precision (%R.S.D. ≤ 9). The method detection limits were 22.5, 1.0, 2.9, 0.95, 1.1 μg/L for Pb(II), Cu(II), Ni(II), Co(II) and Cd(II), respectively.  相似文献   

2.
The diffusion gradients in thin films (DGT) method was investigated and used to measure trace metal concentrations in river water. The principle of DGT is that trace metal ions diffuse through a thin polyacrylamide gel film (the diffusion gel layer) and are subsequently immobilised and concentrated on a layer of Chelex-100 resin embedded in another polyacrylamide gel film (the resin gel layer). These layers are mounted in a plastic holder, which exposes a fixed area of the diffusion gel layer to the water being monitored. Replacement of the normal agarose cross-linked diffusion gel with bisacrylamide cross-linked gel altered the ion uptake properties of DGT. The bisacrylamide cross-linked gel weakly, and with little selectivity, bound metal ions prior to their irreversible binding to Chelex-100. Trace metal ion uptake by these DGT devices was thus dependent on ionic strength and temperature, although the ionic strength effect is relatively small for most natural waters and negligible in sea water. The concentrations of Cd, Co, Cu, Ni, Pb, and Zn in the Water of Leith, an urban stream in Dunedin, New Zealand, were measured by DGT and the results compared with total dissolved concentrations of these metals measured in conventional (bottle) samples collected in parallel with the DGT monitoring. Greater than 90% of the total dissolved Cd and Zn; 20-40% of the total dissolved Co, Ni, and Pb; and 5% of the total dissolved Cu was available to the DGT method.  相似文献   

3.
A novel automated off-line preconcentration system for trace metals (Al, Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in seawater was developed by improving a commercially available solid-phase extraction system SPE-100 (Hiranuma Sangyo). The utilized chelating resin was NOBIAS Chelate-PA1 (Hitachi High-Technologies) with ethylenediaminetriacetic acid and iminodiacetic acid functional groups. Parts of the 8-way valve made of alumina and zirconia in the original SPE-100 system were replaced with parts made of polychlorotrifluoroethylene in order to reduce contamination of trace metals. The eluent pass was altered for the back flush elution of trace metals. We optimized the cleaning procedures for the chelating resin column and flow lines of the preconcentration system, and developed a preconcentration procedure, which required less labor and led to a superior performance compared to manual preconcentration (Sohrin et al. [5]). The nine trace metals were simultaneously and quantitatively preconcentrated from ∼120 g of seawater, eluted with ∼15 g of 1 M HNO3, and determined by HR-ICP-MS using the calibration curve method. The single-step preconcentration removed more than 99.998% of Na, K, Mg, Ca, and Sr from seawater. The procedural blanks and detection limits were lower than the lowest concentrations in seawater for Mn, Ni, Cu, and Pb, while they were as low as the lowest concentrations in seawater for Al, Fe, Co, Zn, and Cd. The accuracy and precision of this method were confirmed by the analysis of reference seawater samples (CASS-5, NASS-5, GEOTRACES GS, and GD) and seawater samples for vertical distribution in the western North Pacific Ocean.  相似文献   

4.
The possible adverse effect of competitive binding on DGT (diffusive gradients in thin films) measurements of metals in marine situations was investigated. Of the divalent transition metals, manganese binds most weakly to Chelex resin and is most likely to be affected by competition. In media resembling seawater, the Chelex within DGT devices becomes saturated with Ca and Mg within 2 h, and at pH 5–6 the sensitivity of the DGT measurement for Mn is substantially reduced, due to the appreciable concentration of Mn in contact with the resin. For media resembling freshwater DGT gives a near theoretical response for Mn. Iron was shown to be capable of displacing Mn and to a more limited extent Cd from the resin when its capacity for Fe is approached. Vertical profiles of Mn in a mesocosm sediment, obtained by deploying DGT for different times, could be explained by this displacement effect. The problem only occurs when Fe concentrations are exceptionally high and can be avoided by using short deployment times, typically less than 12 h. Whilst most trace metals can be simply measured by deploying DGT in marine systems, for Mn consideration should be given to possible effects associated with the capacity of the Chelex binding layer being approached by accumulation of the other cations present.  相似文献   

5.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

6.
A series of experiments were undertaken to investigate the effect of ionic strength and the concentration of free sodium ions in the resin gel on the performance of the diffusive gradients in thin films (DGT) technique. When the free sodium ion concentration in the resin gel was estimated by the time-dependent release into solution, it agreed with a previous estimate. However, equilibration with different volumes of water gave a higher value, suggesting that inherent averaging in the time-dependent release method underestimates the free concentration. DGT measurements of Cu and Cd were made over a wide range of ionic strengths (from 3 μmol l−1 to 0.8 mol l−1). For all the ionic strengths above 100 μmol l−1 there was no significant difference between measurements made by DGT and measurements made directly on the solution using atomic absorption spectroscopy. Below 100 μmol l−1 results were erratic. They did not comply with a theory that predicts high results for DGT based on enhancement of the diffusion coefficient of trace metal cations by counter diffusion of sodium ions. When Cd in solutions with a range of ionic strengths was measured by DGT there was no difference whether the resin gels were in Na or Ca form. Rather than counter diffusion of Na ions, it is suggested that the spurious behaviour at low ionic strength is due to interactions of the trace metals with the diffusion gel when there are insufficient excess cations present.  相似文献   

7.
A selective method of elution for the extraction of heavy metals from sea waters on a chelating resin.The extraction of heavy metals in sea water with Chelex 100 prior to their determination by atomic absorption spectrometry (a.a.s.) with electrothermal atomization is discussed. Maximum retention of heavy metals is not obtained with the resin in the H+ form, because it is gradually transformed in contact with sea water by the fixation of alkali and alkaline-earth cations which are eluted simultaneously with the heavy metals and interfere during a.a.s. The separation of heavy metals is quantitative on Chelex 100 in the Ca2+ form; treatment with dilute acetic acid (1 + 99) eliminates the alkali and alkaline-earth metals fixed on the resin before elution or the heavy metals. Elution with 1 M nitric acid gives simultaneous and quantitative recovery of Cu, Pb, Ni, Zn, Cd and Co; intermediate elution with 0.01 M nitric acid isolates Zn, Cd and Co from Cu and Pb, which are subsequently eluted with 1 M nitric acid.  相似文献   

8.
The dynamic technique of diffusive gradients in thin films (DGT), that measures metal speciation in situ, has found wide environmental application. Simple interpretation of the metal accumulation in terms of a solution concentration has assumed that trace metals do not penetrate beyond the surface of the binding layer, but penetration, although theoretically discussed has not yet been directly measured. Multiple binding layers were used to enable analysis of different depths of a DGT binding phase (Chelex-100 or iminodiacetate resins). In simple metal solution (no ligand) at pH 7, metal penetration to the back layer was low and similar for all metals. However, at lower pH up to 42% of an individual metal accumulated in the back resin layer. This was most noticeable for Mn at pH 4 and 5, but Cd and Co were also affected at pH 4. These results were consistent with rate limited binding, particularly for Mn. A kinetic model successfully fitted the data and allowed derivation of a binding rate constant and the mean distance that metals penetrate into a resin gel (λM). Only for Mn, Co and Cd were experimentally derived λM values greater than the diameter of a Chelex-100 resin bead. For most situations, then, the penetration into the binding layer is negligible and binding of trace metal ions can be regarded as instantaneous, validating the simple use and interpretation of DGT. For weakly binding metals at low pH the slower binding allows penetration, which may affect the DGT measurement.  相似文献   

9.
A novel binding phase was developed for use in diffusive gradients in thin-film (DGT) sampling for Cu(II) by employing methylthymol blue as a chelating and chromogenic agent. Methylthymol blue was adsorbed onto beads of Dowex 1 × 8 resin (200-400 mesh) and the resin beads were then immobilised onto an adhesive disc. Analysis of exposed binding discs by either UV-vis spectrophotometry or computer imaging densitometry provided robust quantification of adsorbed Cu(II) in the 0.2-1 μg cm−2 range, allowing detection at μg L−1 concentrations in the test solution (ca. 17 μg L−1 for a 24 h deployment), and in good agreement with established DGT theory. The method was shown to be a potential replacement for binding phases based on Chelex 100 where a colorimetric response to a specific metal is desired.  相似文献   

10.
The chelating resin Metalfix Chelamine and the strong cation exchanger Dowex 50W-X4 were studied for the off-line pre-concentration of Cd, Co, Cu, Ni and Zn prior to the measurements by the inductively coupled plasma atomic emission spectrometry. Different approaches to the recovery of metals were investigated and compared: the elution with the solutions of HCl and HNO3 and the decomposition of the resins with the adsorbed metals by means of the high-pressure microwave assisted system. Due to the problem arisen with the quantitative elution of the metals from the resins, which bound the analytes very strongly, the procedure of the digestion of the resin after the pre-concentration step was preferable to the plain elution, giving significantly better recoveries of the metals. The chosen procedure was applied for the determination of traces of Cd, Co, Cu, Ni and Zn in beer. For the analysis, mineralised and not mineralised beer samples were treated with Dowex 50W-X4 resin in order to assess the total content of Cd, Co, Cu, Ni and Zn and the fraction of the cationic labile species of the analytes, respectively. The increase in the sensitivity allowed determination of the selected metals at concentrations of order of 1 ng ml−1. The accuracy of the entire procedure was verified by the recovery test in the spiked samples of beer. The proposed method provides full recovery for Cd (101±1%), Co (99±2%) and Zn (106±3%) and reasonably high recovery for Cu (84±1%) and Ni (89±1%).  相似文献   

11.
In this work, 1,10-phenanthroline was used as a complexing agent for the separation and preconcentration of Cd(II), Co(II), Ni(II), Cu(II) and Pb(II) on activated carbon. The metals were adsorbed on activated carbon by two methods: static (1) and dynamic (2). The optimal condition for separation and quantitative preconcentration of metal ions with activated carbon for the proposed methods was for (1) in the static methods in the pH range 7-9. The desorption was found quantitative with 8 mol dm−3 HNO3 for Cd(II) (92.6%), Co(II) (95.6%), Pb(II) (91.0%), and with 3 mol dm−3 HNO3 for Cd(II) (95.4%), Pb(II) (100.2%). The preconcentration factor was 100 with R.S.D. values between 1.0 and 2.9%. For (2), the dynamic method (SPE), the pH range for the quantitative sorption was 7-9. The desorption was found quantitative with 8 mol dm−3 HNO3 for Cd(II) (100.6%), Pb(II) (94.4%), and reasonably high recovery for Co(II) (83%), Cu(II) (88%). The optimum flow rate of metal ions solution for quantitative sorption of metals with 1,10-phenanthroline was 1-2 cm3 min−1 whereas for desorption it was 1 cm3 min−1. The preconcentration factor was 50 for all the ions of the metals with R.S.D. values between 2.9 and 9.8%.The samples of the activated carbon with the adsorbed trace metals can be determined by ICP-OES after mineralization by means of a high-pressure microwave mineralizer. The proposed method provides recovery for Cd (100.8%), Co (97.2%), Cu (94.6%), Ni (99.6%) and Pb (100.0%) with R.S.D. values between 1.2 and 3.2%.The preconcentration procedure showed a linear calibration curve within the concentration range 0.1-1.5 μg cm−3. The limits of detection values (defined as “blank + 3s” where s is standard deviation of the blank determination) are 5.8, 70.8, 6.7, 24.6, and 10.8 μg dm−3 for Cd(II), Pb(II), Co(II), Ni(II) and Cu(II), respectively, and corresponding limit of quantification (blank + 10s) values were 13.5, 151.3, 20.0, 58.9 and 33.2 μg dm−3, respectively.As a result, these simple methods were applied for the determination of the above-mentioned metals in reference materials and in samples of plant material.  相似文献   

12.
A novel method, combining isotope dilution with standard additions, was developed for the analysis of eight elements (Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb) in seawater. The method requires just 12 mL of sample and employs an off-line pre-concentration step using the commercially available chelating resin Toyopearl AF-Chelate-650M prior to determination by high resolution inductively coupled plasma magnetic sector mass spectrometry (ICP-MS). Acidified samples were spiked with a multi-element standard of six isotopes (57Fe, 62Ni, 65Cu, 68Zn, 111Cd and 207Pb) enriched over natural abundance. In addition, standard additions of a mixed Co and Mn standard were performed on sub-sets of the same sample. All samples were irradiated using a low power (119 mW cm−2; 254 nm) UV system, to destroy organic ligands, before pre-concentration and extraction from the seawater matrix. Ammonium acetate was used to raise the pH of the 12 mL sub-samples (off-line) to pH 6.4 ± 0.2 prior to loading onto the chelating resin. The extracted metals were eluted using 1.0 M Q-HNO3 and determined using ICP-MS. The method was verified through the analysis of certified reference material (NASS-5) and the SAFe inter-comparison samples (S1 and D2), the results of which are in good agreement with the certified and reported consensus values. We also present vertical profiles of the eight metals taken from the Bermuda Atlantic Time Series (BATS) station collected during the GEOTRACES inter-comparison cruise in June 2008.  相似文献   

13.
Gopalan Venkatesh 《Talanta》2007,71(1):282-287
Amberlite XAD-16 was loaded with 4-{[(2-hydroxyphenyl)imino]methyl}-1,2-benzenediol (HIMB) via azo linker and the resulting resin AXAD-16-HIMB explored for enrichment of Zn(II), Mn(II), Ni(II), Pb(II), Cd(II), Cu(II), Fe(III) and Co(II) in the pH range 5.0-8.0. The sorption capacity was found between 56 and 415 μmol g−1 and the preconcentration factors from 150 to 300. Tolerance limits for foreign species are reported. The kinetics of sorption is not slow, as t1/2 is ≤15 min. The chelating resin can be reused for seventy cycles of sorption-desorption without any significant change (<2.0%) in the sorption capacity. The limit of detection values (blank + 3 s) are 1.72, 1.30, 2.56, 2.10, 0.44, 2.93, 2.45 and 3.23 μg l−1 for Zn, Mn, Ni, Pb, Cd, Cu, Fe and Co, respectively. The enrichment on AXAD-16-HIMB coupled with flame atomic absorption spectrometry (FAAS) monitoring is used to determine the metal ion ions in river and synthetic water samples, Co in vitamin tablets and Zn in powdered milk samples.  相似文献   

14.
《Analytical letters》2012,45(7):1441-1450
ABSTRACT

The solid phase extraction of trace amounts of some metal ions from their mixtures using cation exchanger Dowex 50Wx4, cellulose sorbent with phosphonic acid groups Cellex P, chelating resin Chelex 100 and SIO2-TPP sorbent which contains porphyrin ligand covalently attached to aminopropyl silica gel was investigated. With respect to multielement preconcentration Cellex P and Chelex 100 seem to be the best sorbents; the recovery test for Al, Be, Cd, Ni, Pb and Zn were > 90%. Additionally, Cellex P appeared to be suitable for enrichment of Co and Mn. Silica-TPP sorbent could be applied as a selective collector for Mo(VI) and V(IV).  相似文献   

15.
Pohl P  Prusisz B  Zyrnicki W 《Talanta》2005,67(1):155-161
Metalfix Chelamine chelating resins of two different bead sizes (150-300 and 40-80 μm) were examined and compared regarding their application for sorption of Au, Ir, Pd, Pt, Rh and Ru ions from medium of HCl, HNO3 and mixtures of HCl and HNO3. The quantitative enrichment of Au, Ir, Pd and Pt was established for the resin of 150-300 μm particle size and for solutions acidified with HCl and HNO3 (3:1) up to the concentration of 0.50 mol l−1. In the case of Rh and Ru, the uptake of these metals by the resin was lower than 50%. For the elution, solutions of different reagents, i.e. HCl, HNO3, KCN, KI, KSCN and (NH2)2CS, were studied with respect to the complete release of the analytes retained by the resin. In addition, influence of various base metals, i.e. Al, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn, on the retention of the noble metals was investigated. Under the selected conditions for the retention and elution of Au, Ir, Pd and Pt, the analytical performance of the proposed pre-concentration procedure was evaluated and it was applied to the determination of these noble metals in anodic sludge sample.  相似文献   

16.
Dwinna Rahmi 《Talanta》2007,72(2):600-606
The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200-400 mesh), with which trace metals in 50 mL of original seawater sample were concentrated into 0.50 mL of 2 M nitric acid, and then 100-fold preconcentration of trace metals was achieved. Then, 0.50 mL analysis solution was subjected to the multielement determination by ICP-MS equipped with a MicroMist nebulizer for micro-sampling introduction. The preconcentration and elution parameters such as the sample-loading flow rate, the amount of 1 M ammonium acetate for elimination of matrix elements, and the amount of 2 M nitric acid for eluting trace metals were optimized to obtain good recoveries and analytical detection limits for trace metals. The analytical results for V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U in three kinds of seawater certified reference materials (CRMs; CASS-3, NASS-4, and NASS-5) agreed well with their certified values. The observed values of rare earth elements (REEs) in the above seawater CRMs were also consistent with the reference values. Therefore, the compiled reference values for the concentrations of REEs in CASS-3, NASS-4, and NASS-5 were proposed based on the observed values and reference data for REEs in these CRMs.  相似文献   

17.
A chelate resin immobilizing carboxymethylated pentaethylenehexamine (CM-PEHA resin) was prepared, and the potential for the separation and preconcentration of trace elements in water samples was evaluated through the adsorption/elution test for 62 elements. The CM-PEHA resin could quantitatively recover various elements, including Ag, Cd, Co, Cu, Fe, Ni, Pb, Ti, U, and Zn, and rare earth elements over a wide pH range, and also Mn at pH above 5 and V and Mo at pH below 7. This resin could also effectively remove major elements, such as alkali and alkaline earth elements, under acidic and neutral conditions. Solid phase extraction using the CM-PEHA resin was applicable to the determination of 10 trace elements, Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, V, and Zn, in certified reference materials (EnviroMAT EU-L-1 wastewater and ES-L-1 ground water) and treated wastewater and all elements except for Mn in surface seawater using inductively coupled plasma atomic emission spectrometry. The detection limits, defined as 3 times the standard deviation for the procedural blank using 500 mL of purified water (50-fold preconcentration, n = 8), ranged from 0.003 μg L−1 (Mn) to 0.28 μg L−1 (Zn) as the concentration in 500 mL of solution.  相似文献   

18.
Venkatesh G  Singh AK 《Talanta》2005,67(1):187-194
2-{[1-(3,4-Dihydroxyphenyl)methylidene]amino}benzoic acid (DMABA) was loaded on Amberlite XAD-16 (AXAD-16) via azo linker and the resulting resin AXAD-16-DMABA explored for enrichment of Zn(II), Mn(II), Ni(II), Pb(II), Cd(II), Cu(II), Fe(III) and Co(II). The optimum pH values for extraction are 6.5-7.0, 5.0-6.0, 5.5-7.5, 5.0-6.5, 6.5-8.0, 5.5-7.0, 4.0-5.0 and 6.0-7.0, respectively. The sorption capacity was found between 97 and 515 μmol g−1 and the preconcentration factors from 100 to 450. Tolerance limits for foreign species are reported. The kinetics of sorption is fast as t1/2 is ≤5 min. The chelating resin can be reused for 50 cycles of sorption-desorption without any significant change (<1.5%) in the sorption capacity. The limit of detection values (blank +3 s) are 1.12, 1.38, 1.76, 0.67, 0.77, 2.52, 5.92 and 1.08 μg L−1 for Zn(II), Mn(II), Ni(II), Pb(II), Cd(II), Cu(II), Fe(III) and Co(II), respectively. The enrichment on AXAD-16-DMABA coupled with monitoring by flame atomic absorption spectrometry (FAAS) is used to determine all the metal ion ions in river and synthetic water samples, Co in vitamin tablets and Zn in milk samples.  相似文献   

19.
Magnetically driven separation technology has received considerable attention in recent decade for its great potential application. In this study, we investigate the application of silica-modified magnetite nanoparticles (NPs) coated with a cationic surfactant as adsorbent for microextraction and determination of trace amounts of Cu(II), Ni(II), Co(II), Cd(II), Pb(II) and Mn(II) from environmental water samples. The synthesized silica-coated NPs in combination with cetylpyridinium bromide have the ability to adsolubilize the metal ions after complexation with 8-hydroxyquinoline. The NPs bearing the target metals are easily separated from the aqueous solution by applying an external magnetic field and the complexed metals were desorbed using acidic methanol. The desorbed analytes are introduced into the graphite furnace of an atomic absorption spectrometer. The effect of pH, complexing agent, amount of cetylpyridinium bromide, microextraction time, desorption conditions, ionic strength on extraction efficiency of the metal ions are investigated and optimized. Under the optimized conditions, the detection limits for Cu(II), Ni(II), Co(II), Cd(II), Pb(II) and Mn(II) are 4.7, 9.1, 9.5, 2.3, 7.4 and 15.3 ng L−1, respectively and the relative standard deviations (n = 6) are less than 3.6%. The accuracy of the method was evaluated by recovery measurements on the spiked samples and good recoveries (93-113%) with low RSDs were achieved.  相似文献   

20.
The determination of trace metals in river water and ground water by DPSV is seriously disturbed by the presence of organic complexes. The influence of these substances can be eliminated by acidification of the samples with acids. Cd, Pb and Cu were determined at pH 1.1 (HNO3 medium) and Zn, Cd, Pb and Cu at pH 2 (HCl medium), in both the Nile river and ground water. Zn was determined at pH 3.5 in HCl and pH 4.5 in HNO3, after neutralizing the samples with NH3/NH4Cl buffer. Manganese could then be determined, after further addition of ammoniacal buffer solution up to pH 7.5 and 8.5. Ni and Co were determined in the adsorptive mode after formation of dimethylglyoximates at pH 9.2. The effect of pH on the stripping peaks of manganese was studied. Good agreement was observed between DPSV and AAS results for Zn, Cd, Pb, Cu and Mn, but the concentrations of Ni and Co were below the detection limits for AAS. Good agreement was obtained between DPSV results in HCl and HNO3 for Ni and Co. The results indicate that decomposition of organic complexes by acidification with HNO3 is better than in the case with HCl for Zn, Pb, Cu, Ni and Co, but HCl is better than HNO3 for Cd and Mn.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号