首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The electroanalytical determination of isoprenaline in pharmaceutical preparations of a homemade carbon paste electrode modified with copper(II) hexacyanoferrate(III) (CuHCF) was studied by cyclic voltammetry. Several parameters were studied for the optimization of the sensor such as electrode composition, electrolytic solution, pH effect, potential scan rate and interferences in potential. The optimum conditions were found in an electrode composition (in mass) of 15% CuHCF, 60% graphite and 25% mineral oil in 0.5 mol l−1 acetate buffer solution at pH 6.0. The analytical curve for isoprenaline was linear in the concentration range from 1.96×10−4 to 1.07×10−3 mol l−1 with a detection limit of 8.0×10−5 mol l−1. The relative standard deviation was 1.2% for 1.96×10−4 mol l−1 isoprenaline solution (n=5). The procedure was successfully applied to the determination of isoprenaline in pharmaceutical preparations; the CuHCF modified carbon paste electrode gave comparable results to those results obtained using a UV spectrophotometric method.  相似文献   

2.
The L-dopa is the immediate precursor of the neurotransmitter dopamine. Unlike dopamine, L-dopa easily enters the central nervous system and is used in the treatment of Parkinson’s disease. A sensitive and selective method is presented for the voltammetric determination of L-dopa in pharmaceutical formulations using a carbon paste electrode modified with trinuclear ruthenium ammine complex [(NH3)5RuIIIORuIV(NH3)4ORuIII(NH3)5]6+ (Ru-red) incorporated in NaY zeolite. The parameters which influence on the electrode response (paste composition, potential scan rate, pH and interference) were also investigated. The optimum conditions were found to an electrode composition (m/m) of 25% zeolite containing 6.7% Ru, 50% graphite and 25% mineral oil in acetate buffer at pH 4.8. Voltammetric peak currents showed a linear response for L-dopa concentration in the range between 1.2×10−4 and 1.0×10−2 mol l−1 (r=0.9988) with a detection limit of 8.5×10−5 mol l−1. The variation coefficient for a 1.0×10−3 mol l−1 L-dopa (n=10) was 5.5%. The results obtained for L-dopa in pharmaceutical formulations (tablet) was in agreement with compared official method. In conclusion, this study has illustrated that the proposed electrode modified with Ru-red incorporated zeolite is suitable valuable for selective measurements of L-dopa.  相似文献   

3.
The preparation and electrochemical characterization of a carbon paste electrode modified with copper(II) hexacyanoferrate(III) (CuHCF) as well as its behavior as electrocatalyst toward the oxidation of N-acetylcysteine were investigated. The electrochemical behavior of the modified electrode and the electrooxidation of N-acetylcysteine were explored using sweep linear voltammetry. The best voltammetric response was observed for a paste composition of 20% (w/w) copper(II) hexacyanoferrate(III) complex, acetate buffer solution at pH of 6.0 as the electrolyte and scan rate of 10 mV s− 1. A linear voltammetric response for N-acetylcysteine was obtained in the concentration range from 1.2 × 10− 4 to 8.3 × 10− 4 mol L− 1, with a detection limit of 6.3 × 10− 5 mol L− 1. The proposed electrode is useful for the quality control and routine analysis of N-acetylcysteine in pharmaceutical formulations.  相似文献   

4.
Svancara I  Foret P  Vytras K 《Talanta》2004,64(4):844-852
A procedure for the determination of chromium is described based on synergistic pre-concentration of the chromate anion at a carbon paste electrode modified in situ with quarternary ammonium salts such as 1-ethoxycarbonylpentadecyltrimethylammonium bromide (Septonex®), cetyltrimethylammonium bromide (CTAB) or cetylpyridinium bromide (CPB). The proper electrochemical detection utilises the reduction Cr(VI) → Cr(III) performed in the differential pulse cathodic voltammetric mode. In discussion, considerable attention has been paid to the accumulation mechanism at the carbon paste electrode in the presence of surfactants. Furthermore, after optimising the corresponding experimental conditions (0.1-0.3 M HCl + 0.1 M NaCl as the supporting electrolyte, 2.5-25 μM as the total concentration of modifier, pre-concentration at +0.7 V versus Ag/AgCl and the stripping from +0.7 to −0.4 V), the analytical performance of the method has been evaluated. The signal of interest was reproducible within ±8% and proportional to the concentration in a range of 0.5-50 μM CrO42−, with a limit of detection (S/N = 3:1) of about 5×10−8 M CrO42− (with accumulation for 300 s). Interference studies were focused mainly on the species capable of forming ion-pairs with the modifier; i.e., TlCl4, AuCl4, PdCl42−, PtCl62−, VO43−, MnO4 and I. Practical applicability of the method was tested on model solutions via the recovery rates (typically 90-110%) or using selected certified reference materials (tea, bush leaves, clover) and two samples of black tea when the respective results were compared to those obtained by the reference determinations with ICP-AES.  相似文献   

5.
A simple and rapid electrochemical method is developed for the determination of trace-level norfloxacin, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs). The MWCNTs/Nafion film-coated glassy carbon electrode (GCE) is constructed and the electrochemical behavior of norfloxacin at the electrode is investigated in detail. The results indicate that MWCNTs modified glassy carbon electrode exhibited efficiently electrocatalytic oxidation for norfloxacin (NFX) with relatively high sensitivity, stability and life time. Under conditions of cyclic voltammetry, the current for oxidation of selected analyte is enhanced significantly in comparison to the bare GCE. The electrocatalytic behavior is further exploited as a sensitive detection scheme for the analyte determinations by linear sweep voltammetry (LSV). Under optimized condition in voltammetric method the concentration calibration range and detection limit (S/N=3) are 0.1-100 micromol/L and 5 x 10(-8)mol/L for NFX. The proposed method was successfully applied to NFX determination in tablets. The analytical performance of this sensor has been evaluated for detection of the analyte in urine as a real sample.  相似文献   

6.
The preconcentration and voltammetric behavior of BiIII on a sodium humate modified carbon paste electrode was studied by means of cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV). The proposed measurement involves an initial nonelectrolytic preconcentration step in which BiIII is complexed by the surface modifier in a solution of 0.05 M KNO3-0.0106 M HNO3 (pH 2.0) and a subsequent electrochemical scan step in which the preconcentrated BiIII was reduced and then oxidized promptly in supporting electrolyte of 0.5 M HNO3. The resulting DPSV anodic current was proportional to the concentration of BiIII ion over the range of 4.78 × 10−8–1.44 × 10−5 M. The detection limit was 4.78 × 10−8 M. The proposed method was used to determine bismuth in various samples. Various factors affecting the electrode behavior were also investigated at the same time.  相似文献   

7.
A bentonite-modified carbon paste electrode has been applied to the determination of 2-nitrophenol by differential pulse voltammmetry. The electrochemical reduction of 2-nitrophenol at –0.8 V is carried out in an artificial sea water-formic acid/sodium formate medium at pH 4. The peak height was found to be dependent on the pH over the range 2–11; the presence of a secondary process was observed in the pH range 8–11. The peak potential showed a dependence on pH, with two linear regions with different slopes. A linear relationship between peak intensity and concentration was obtained in the range 0.07–10 mgl–1, with a detection limit of 0.03 mg 1–1 and a coefficient of variation of 1.3% at 5 mg 1–1. The effects of organic and inorganic species on the 2-nitrophenol determination were studied with a view to testing the resolution of the voltammetric technique. The proposed method has been applied to sea water samples with good results.  相似文献   

8.
The electrochemical behaviour of pyridoxine hydrochloride (pyridoxine HCl) at the plain carbon paste electrode and the electrode modified with oxa crown ether has been studied using voltammetric and impedance measurements. The macrocycles used as modifiers were 18-crown-6, dibenzo-18-crown-6 (DB18C6), dicyclohexano-18-crown-6 and dibenzo-24-crown-8, out of which DB18C6 gave better response for pyridoxine HCl. Tris buffer (pH 10.3) was chosen as an appropriate medium among the several supporting electrolytes of varying pH studied. The characterization of the DB18C6-modified electrode (CME-DB18C6) using kinetic parameters such as number of electrons (n) and electron transfer coefficient (α) is studied by cyclic voltammetry. Electrochemical impedance spectroscopic measurements obtained confirm the current enhancement over the modified electrode. Analytical applications of this electrode have been studied for the determination of pyridoxine HCl. A sensitive linear working range of 0.6 to 100 μg cm−3 with a detection limit of 0.4 μg cm−3 by differential pulse voltammetry was observed for pyridoxine HCl on CME-DB18C6. However, on decreasing the scan rate to 5 mV s−1, the detection limit lowered to 0.2 μg cm−3. Interference from some vitamins like thiamine hydrochloride, riboflavin, nicotinamide, para-aminobenzoic acid, cyanocobalamin, folic acid and d-biotin and amino acid l-tryptophan was studied, and simultaneously, riboflavin, thiamine hydrochloride and pyridoxine HCl were determined over the modified electrode, CME-DB18C6. The modified electrode is successfully used for the determination of pyridoxine HCl in multivitamin pharmaceutical preparations.  相似文献   

9.
The reactions of dimethyl-, diethyl- and dibutyltin(IV) oxides with pyridoxine (PN) in toluene/ethanol led to the formation of compounds [SnR2(PN-2H)] which were characterized by EI and FAB mass spectrometry and by IR, Raman, Mössbauer and 1H, 13C and 119Sn NMR spectroscopy. The structures of [SnEt2(PN-2H)] · CH3OH, [SnBu2(PN-2H)] and [SnEt2(PN-2H)(DMSO)] were determined by X-ray diffractometry. The first two contain dimeric [SnR2(PN-2H)]2 units in which two bridging-chelating pyridoxinate anions link the Sn atoms, while in [SnEt2(PN-2H)(DMSO)] the DMSO coordinates to the tin atom via its O atom in a similar dimeric unit.  相似文献   

10.
A sensitive electroanalytical method for determination of gemifloxacin in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at multi-walled carbon nanotubes modified glassy carbon electrode in the presence of CTAB. Solubilized system of different surfactants including SDS, Tween-20 and CTAB were taken for the study of electrochemical behaviour of gemifloxacin at modified electrode. The reduction peak current increases in the presence of CTAB while other surfactants show opposite effect. The modified electrode exhibits catalytic activity, high sensitivity, stability and is applicable over wide range of concentration for the determination of gemifloxacin. The mechanism of electrochemical reduction of gemifloxacin has been proposed on the basis of CV, SWV, DPV and coulometeric techniques. The proposed squarewave voltammetric method shows linearity over the concentration range 2.47-15.5 μg/mL. The achieved limits of detection (LOD) and quantification (LOQ) are 0.90 ng/mL and 3.0 ng/mL respectively.  相似文献   

11.
Herein, an electrochemical method was developed for the determination of ciprofloxacin based on the enhancement effect of cetyltrimethylammonium bromide (CTAB). In pH 7.0 phosphate buffer, a poorly-defined oxidation peak is observed at carbon paste electrode (CPE) for ciprofloxacin. However, the oxidation peak current remarkably increases in the presence of low concentration of CTAB, suggesting that CTAB exhibits obvious enhancement effect to the determination of ciprofloxacin. All the experimental parameters, such as supporting electrolyte, pH value, concentration of CTAB, and accumulation time, were optimized for ciprofloxacin analysis. This new method possesses high sensitivity (detection limit is 5.0 × 10−8 mol l−1), wide linearity (1.0 × 10−7−2.0 × 10−5 mol l−1), rapid response, low cost and simplicity. Finally, this method was successfully employed to detect ciprofloxacin in drugs. The text was submitted by the authors in English.  相似文献   

12.
A new chemically modified electrode is constructed based on iron(III) doped zeolite modified carbon paste electrode (Fe(3+)Y/ZCME). The electrode was evaluated as a sensor for sub-micromolar determination of tryptophan (Trp), uric acid (UA) and ascorbic acid (AA) in aqueous solutions. The measurements were carried out by application of the differential pulse voltammetry (DPV) method in phosphate buffer solution with pH 3.5. Iron(III) loaded in zeolite can increase anodic peak currents by adsorption of Trp, UA and AA on electrode surface The analytical performance was evaluated with respect to the carbon paste composition, pH of solution, accumulation time and accumulation potential. The prepared electrode shows voltammetric responses with high sensitivity and selectivity for Trp, UA and AA in optimal conditions, which makes it very suitable for simultaneous determination of these compounds. The linear calibration range for AA in the presence of 50muM UA and 50muM Trp was 0.6muM to 100muM, with a correlation coefficient of 0.9992, and a detection limit of 0.21muM (S/N=3). A linear relationship was found for UA in the range of 0.3-700muM containing 10muM AA and 50muM Trp, with a correlation coefficient of 0.9990 and a detection limit of 0.08muM. The linear calibration range for Trp in the presence of 10muM AA and 50muM UA was 0.2-150muM, with a correlation coefficient of 0.9996, and a detection limit of 0.06muM. The proposed method was successfully applied for determination Trp, UA and AA in biological systems and pharmaceutical samples.  相似文献   

13.
The voltammetric behavior of 2-methyl-4,6-dinitrophenol at a modified carbon paste electrode has been studied. Among the modifiers tested, hidepowder was found to give the best results. Cyclic voltammetry and differential pulse voltammetry were used to study the nature of the reaction; the possibility of accumulation of the analyte onto the electrode was studied by differential pulse voltammetry. An irreversible behavior and the adsorption of 2-methyl-4,6-dinitrophenol on the electrode were confirmed. The reduction signal shows two peaks. A linear relationship between the first peak height and the concentration of 2-methyl-4,6-dinitrophenol was obtained in the range 0.001–5 mg l−1, with a detection limit of 3.2 μg l−1 and a relative standard deviation of 3.20%. The interferences with the reduction peak of 2-methyl-4,6-dinitrophenol of several nitro- and chloro-phenols and inorganic species were tested.  相似文献   

14.
Ashrafi AM  Vytřas K 《Talanta》2011,85(5):2700-2702
A new procedure was elaborated to determine mercury(II) using an anodic stripping square-wave voltammetry at the antimony film carbon paste electrode (SbF-CPE). In highly acidic medium of 1 M hydrochloric acid, voltammetric measurements can be realized in a wide potential window. Presence of cadmium(II) allows to separate peaks of Hg(II) and Sb(III) and apparently catalyses reoxidation of electrolytically accumulated mercury, thus allowing its determination at ppb levels. Calibration dependence was linear up to 100 ppb Hg with a detection limit of 1.3 ppb. Applicability of the method was tested on the real river water sample.  相似文献   

15.
A modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) and 3-(4-methoxybenzylideneamino)-2-thioxothiazolodin-4-one as a new synthesized Schiff base was constructed for the simultaneous determination of trace amounts of Hg(II) and Pb(II) by square wave anodic stripping voltammetry. The modified electrode showed an excellent selectivity and stability for Hg(II) and Pb(II) determinations and for accelerated electron transfer between the electrode and the analytes. The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as pH, deposition potential and deposition time were optimized for the purpose of determination of traces of metal ions at pH 3.0. Under optimal conditions the limits of detection, based on three times the background noise, were 9.0 × 10−4 and 6.0 × 10−4 μmol L−1 for Hg(II) and Pb(II) with a 90 s preconcentration, respectively. In addition, the modified electrode displayed a good reproducibility and selectivity, making it suitable for the simultaneous determination of Hg(II) and Pb(II) in real samples such as sea water, waste water, tobacco, marine and human teeth samples.  相似文献   

16.
A simple electrochemical method was developed for the single and simultaneous determination of butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) in food samples using square-wave voltammetry (SWV). A carbon composite electrode modified (MCCE) with copper (II) phosphate immobilized in a polyester resin was proposed. The modified electrode allowed the detection of BHA and BHT at potentials lower than those observed at unmodified electrodes. A separation of about 430 mV between the peak oxidation potentials of BHA and BHT in binary mixtures was obtained. The calibration curves for the simultaneous determination of BHA and BHT demonstrated an excellent linear response in the range from 3.4 × 10−7 to 4.1 × 10−5 mol L−1 for both compounds. The detection limits for the simultaneous determination of BHA and BHT were 7.2 × 10−8 and 9.3 × 10−8 mol L−1, respectively. In addition, the stability and repeatability of the electrode were determined. The proposed method was successfully applied in the simultaneous determination of BHA and BHT in several food samples, and the results obtained were found to be similar to those obtained using the high performance liquid chromatography method with agreement at 95% confidence level.  相似文献   

17.
M. Ghiaci  R.J. Kalbasi 《Talanta》2007,73(1):37-45
The main purpose of this study is to develop an inexpensive, simple, selective and especially highly selective modified mixed-oxide carbon paste electrode (CPE) for voltammetric determination of Pb(II). For the preliminary screening purpose, the catalyst was prepared by modification of SiO2-Al2O3 mixed-oxide and characterized by TG, CHN elemental analysis and FTIR spectroscopy. Using cyclic voltammetry the electroanalytical characteristics of the catalyst have been determined, and consequently the modified mixed-oxide carbon paste electrode was constructed and applied for determination of Pb(II). The electroanalytical procedure for determination of the Pb(II) comprises two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse anodic stripping voltammetry. During the preconcentration step, Pb(II) was accumulated on the surface of the modifier by the formation of a complex with the nitrogen atoms of the pyridyl groups in the modifier. The peak currents increases linearly with Pb(II) concentration over the range of 2.0 × 10−9 to 5.2 × 10−5 mol L−1 (r2 = 0.9995).The detection limit (three times signal-to-noise) was found to be 1.07 × 10−9 mol L−1 Pb(II). The chemical and instrumental parameters have been optimized and the effect of the interferences has been determined. The Proposed method was used for determination of lead ion in the real samples.  相似文献   

18.
本文研究了芬苯达唑(Fenbendazole,FBZ)在石墨烯(RGO)与离子液体(N-丁基吡啶六氟磷酸盐)复合修饰碳糊电极上的电催化氧化及电化学动力学性质。同时用CC法(计时库仑法)、计时电流法(CA)测定FBZ在RGO-[Bupy]PF6/CPE上的电极反应动力学参数,并用方波伏安法(SWV)测定FBZ氧化峰电流(Ip)与其浓度c在4.0×10-8~1.0×10-5mol·L-1范围内呈良好线性关系,线性回归方程为Ip(μA)=1.471+5220.78c(10-3mol·L-1),R=0.9995,检测限(S/N=3)为1.4×10-9mol·L-1,在此基础上用SWV法对FBZ片剂中FBZ含量进行了电化学定量测定,RSD在0.2%~0.9%之间,回收率在99.0%~101.4%之间。  相似文献   

19.
A new modified carbon paste electrode based on multi-walled carbon nanotube and Alizarin Red S acts as a chelating agent for tellurium(IV) ions, is described. The electrochemical responses were found to be analytically suitable to develop a method for the determination of tellurium at low concentration levels. Under optimised operational conditions, the sensor exhibited linear behaviour in the range of 2.0–300 ng mL?1 (correlation coefficient: 0.9982) with a detection limit of 0.45 ng mL?1. The results indicate that the sensor is sensitive and effective for the determination of tellurium in water samples and certified reference materials.  相似文献   

20.
《Electroanalysis》2006,18(22):2218-2224
This article deals with the development of a method for the determination of osmium at a carbon paste electrode (CPE) modified with cationic surfactants of the quaternary ammonium salt type; namely, cetyltrimethylammonium bromide (CTAB) and 1‐(ethoxycarbonyl)‐pentadecyltrimethyl‐ammonium bromide (Septonex); both being added in situ and serving for preconcentration of osmium via its hexachloroosmate(IV) anion. The proper electrochemical detection was performed by cathodic scanning in the differential pulse voltammetric mode. Optimization studies concerning important experimental parameters also included a specially performed potentiometric titration, helping to define the actual stoichiometry for the ion‐pairing process, the main principle and driving force of the accumulation step. In a chloride/acetate buffer based supporting medium and with Septonex as the modifier of choice, the reduction signal for osmium was found to be proportional to the Os(IV) concentration in a range from 5×10?9 to 5×10?7 mol L?1 with a limit of detection close to 5×10?9 mol L?1 (with preconcentration for 60 s). The method capable to determine Os(IV) in the presence of both Pt(IV) and Ir(III) was tested on model solutions as well as with real sample of industrial waste water (spiked with the analyte); both yielding the recovery rates within 88–99%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号