首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for Ge determination in hot spring water and acid extracts from coal fly ash samples involving hydride generation, trapping and atomisation of the hydride generated from Ir-treated graphite tubes (GTs) has been developed. Hydride was generated from hydrochloric acid medium using sodium tetrahydroborate. Several factors affecting the hydride generation, transport, trapping and atomisation efficiency were studied by using a Plackett-Burman design. Results obtained from Plackett-Burman designs suggest that trapping and atomisation temperatures are the significant factors involved on the procedure. The accuracy was studied using NIST-1633a (coal fly ash) reference material. The detection limit of the proposed method was 2.4 μg l−1 and the characteristic mass of 233 pg was achieved. The Ge concentrations in fly ash and hot spring samples were between 6.25-132 μg g−1 and 12.84-36.2 μg l−1.  相似文献   

2.
《Analytica chimica acta》2002,461(2):261-271
Different procedures of tin hydride generation from aqueous and acidified slurries of marine sediment, soil, coal fly ash and coal samples, coupled to electrothermal atomic absorption spectrometry were optimised by using factorial designs. A batch mode generation system and Ir-treated graphite tubes were used for the hydride generation and atomisation, respectively. Eight variables, affecting the hydride generation and hydride transport efficiency (hydrochloric acid and sodium tetrahydroborate concentrations, particle size, acid volume and argon flow rate), the hydride trapping efficiency (trapping temperature and trapping time) and the atomisation efficiency (atomisation temperature) were studied and optimised. In addition, acid pre-treatment procedures assisted by ultrasonic energy were used for soil and coal matrices, to obtain acidified slurries and acid leachates. The involved variables were hydrochloric and nitric acid concentrations, exposure time to ultrasound, particle size and leaching solution volume. Adequate accuracy (41.5±0.8 and 1.4±0.2 mg kg−1, for PACS-1 (sediment marine) and NIST-1633b (coal fly ash), respectively) were obtained by using aqueous slurry reference materials. In addition, values of 6.2±0.6 and 1.2±0.1 mg kg−1 were assessed by analysing GBW-07401 (soil) and NIST-1632c (coal) certified reference materials.  相似文献   

3.
Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USS-ETV-ID-ICP-MS) has been applied to the determination of Cd, Hg and Pb in coal fly ash samples. Thioacetamide (TAC) was used as the modifier. Since the sensitivities of the elements studied in coal fly ash slurry and aqueous solution were quite different, isotope dilution method was used for the determination of Cd, Hg and Pb in these coal fly ash samples. The isotope ratios of each element were calculated from the peak areas of each injection peak. This method has been applied to the determination of Cd, Hg and Pb in NIST SRM 1633a coal fly ash reference material and a coal fly ash sample collected from Kaohsiung area. Analysis results of reference sample NIST SRM 1633a coal fly ash agreed satisfactorily with the certified values. The other sample determined by isotope dilution and method of standard additions was agreed satisfactorily. Precision was better than 6% for most of the determinations and accuracy was better than 4% with the USS-ETV-ID-ICP-MS method. Detection limits estimated from standard addition curves were in the range of 24–58, 6–28 and 108–110 ng g−1 for Cd, Hg and Pb, respectively.  相似文献   

4.
We propose a procedure for the determination of sulfur in coal slurries by high resolution continuum source electrothermal molecular absorption spectrometry. The slurry, whose concentration is 1 mg mL 1, was prepared by mixing 50 mg of the sample with 5% v/v nitric acid and 0.04% m/v Triton X-100 and was homogenized manually. It sustained good stability. The determination was performed via CS molecular absorption at 257.592 nm, and the optimized vaporization temperature was 2500 °C. The accuracy of the method was ensured by analysis of certified reference materials SRM 1632b (trace elements in coal) and SRM 1633b (coal fly ash) from the National Institute of Standards and Technology, using external calibration with aqueous standards prepared in the same medium and used as slurry. We achieved good agreement with the certified reference materials within 95% confidence interval, LOD of 0.01% w/w, and RSD of 6%, which confirms the potential of the proposed method.  相似文献   

5.
A simple, fast and reliable method is described for the quantitative extraction of Sb and Co from inorganic environmental matrices containing variable amounts of silicates prior to their determination by electrothermal-atomic absorption spectrometry. The method is based on the ultrasound-assisted extraction of both elements using the mixture 20% v/v HF + 20% v/v HNO3 as extractant. The extraction procedure was carried out in closed Eppendorf vials immersed in a cup-horn sonoreactor for 20?min. Once extraction has been accomplished, the supernatant liquid is separated from the solid phase and subsequently transferred into the autosampler of the instrument. A two-level full factorial design (24) was applied for screening optimisation of the variables influencing the ultrasonic extraction. These variables were: sonication time; amplitude of the ultrasound energy; nitric and hydrofluoric acid concentrations. MLDs were 0.20 and 0.06?µg?·?g?1 for Sb and Co, respectively. Between-batch precision values, expressed as relative standard deviations (n?=?3), were less than 5.5 and 9.6% for Sb and Co, respectively. The method was evaluated using a wide variety of inorganic certified reference materials, such as SRM 2702 (Marine Sediment), SRM 2782 (Industrial Sludge), BCR 176R (Fly Ash), SRM 1633b (Coal Fly Ash) SRM 2710 (Montana Soil) and SRM 2711 (Montana Soil).  相似文献   

6.
Rowe JJ  Steinnes E 《Talanta》1977,24(7):433-439
Thirty elements are determined in coal and fly ash by instrumental neutron-activation analysis using both thermal and epithermal irradiation. Gamma-ray spectra were recorded 7 and 20 days after the irradiations. The procedure is applicable to the routine analysis of coals and fly ash. Epithermal irradiation was found preferable for the determination of Ni, Zn, As, Se, Br, Rb, Sr, Mo, Sb, Cs, Ba, Sm, Tb, Hf, Ta, W, Th and U, whereas thermal irradiation was best for Sc, Cr, Fe, Co, La, Ce, Nd, Eu, Yb and Lu. Results for SRM 1632 (coal) and SRM 1633 (fly ash) agree with those of other investigators.  相似文献   

7.
Different techniques were selected for comprehensive characterization of seven samples of fly ashes collected from the electrostatic precipitator of the San Nicolás thermal power plant (Buenos Aires, Argentina). Particle size was measured using laser based particle size analyzer. X-ray diffraction powder (XRD) analysis and scanning electron microscopy (SEM) were used to characterize the mineral phase present in the matrix consisting basically of aluminosilicates and large amounts of amorphous material. The predominant crystalline phases were mullite and quartz. Major and minors elements (Al, Ca, Cl, Fe, K, Mg, Na, S, Si and Ti) were detected by energy dispersive X-ray analysis (EDAX). Trace elements (As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Se, V and Zn) content was quantified by inductively coupled plasma optical emission spectrometry (ICP OES). Different acid mixtures and digestion procedures were compared for subsequent ICP OES measurements of the dissolved samples. The digestion procedures used were: i) a mixture of FH + HNO3 + HClO4 (open system digestion); ii) a mixture of FH + HNO3 (MW-assisted digestion); iii) a mixture of HF and aqua regia (MW-assisted digestion). Instrumental neutron activation analysis (INAA) was employed for the determination of As, Ba, Co, Cr, Ce, Cs, Eu, Fe, Gd, Hf, La, Lu, Rb, Sb, Sc, Sm, Ta, Tb, Th, U and Yb. The validation of the procedure was performed by the analysis of two certified materials namely, i) NIST 1633b, coal fly ash and ii) GBW07105, rock. Mean elements content spanned from 41870 μg g− 1 for Fe to 1.14 μg g− 1 for Lu. The study showed that Fe (41870 μg g− 1) ? V (1137 μg g− 1) > Ni (269 μg g− 1) > Mn (169 μg g− 1) are the main components. An enrichment, with respect to crustal average, in many elements was observed especially for As, V and Sb that deserve particular interest from the environmental and human health point of view.  相似文献   

8.
A slurry sampling method for the simultaneous determination of hydride forming (As, Bi, Ge, Sb, Se, Sn) and Hg and non-hydride forming (Ca, Fe, Mg, Mn, Zn) elements, without total sample digestion has been developed using the commercial dual-mode sample introduction system (MSIS) coupled with microwave induced plasma optical emission spectrometry (MIP-OES) from biological and environmental reference materials and real samples. The main advantage of this system is its simultaneous determination of elements that form volatile vapor species and elements that do not, without any instrumental changes. Optimization of reaction, nebulization and instrumental conditions was performed to characterize the new system. Slurry concentration up to 4% m/v (particles < 100 μm) prepared in 10% HNO3 containing 100 μL of decanol, by application of ultrasonic agitation, was used with calibration by the standard addition technique. An ultrasonic probe was used to homogenize the slurry in the quartz cup just before its introduction into the reaction/nebulization system; the multimode sample introduction system (MSIS) combines the benefits of nebulization and vapor generation in a single device. Detection limits (LOD, 3σblank, peak area) of 0.07, 0.29, 0.25, 0.10, 0.12, 0.14, 0.11, 0.28, 0.42, 0.02, 0.21 and 0.34 μg g− 1 were obtained for As, Bi, Ge, Sb, Se, Sn, Hg, Ca, Fe, Mg, Mn and Zn, respectively. The relative standard deviations were ca. 10%, adequate for slurry analysis. To test the accuracy, six certified reference materials were analyzed with the analyte concentrations mostly in the μg g− 1 level. Measured concentrations are in satisfactory agreement with certified values for the biological reference materials (LUTS-1, DOLT-2) and environmental reference materials (PACS-1, GWB 07302, NIST 2710, NBS 1633b), all adequate for slurry sampling. The method was successfully applied to the determination of the elements in real samples (coal fly ash, lake sediment, sewage). The method requires small amounts of reagents and reduces contamination and losses.  相似文献   

9.
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) was used in the determination of As and Sb concentrations in fly ash samples. The effect of sample pre-treatment reagents and measurement parameters used for hydride generation was evaluated. Due to memory effects observed, the appropriate read delay time was adjusted to 60 s resulting in RSDs 0.6% and 2.3% for As and Sb, respectively. The most suitable volumes of pre-reduction reagents for 10 mL of sample were 4 mL of KI/ascorbic acid (5%) and 6 mL of HCl (conc.). The determination of Sb was significantly interfered by HF, but the interference could be eliminated by adding 2 mL of saturated boric acid and heating the samples to 60 °C at least 45 min. The accuracy of the method was studied by analyses of SRM 1633b and two fly ash samples with the recovery test of added As and Sb. As high a recovery as 96% for SRM 1633b was reached for As using 193.696 nm with two-step ultrasound-assisted digestion. A recovery rate of 103% was obtained for Sb using 217.582 nm and the pre-reduction method with the addition of 2 mL of saturated boric acid and heating. The quantification limits for the determination of As and Sb in the fly ash samples using two-step ultrasound-assisted digestion followed with HG-ICP-OES were 0.89 and 1.37 mg kg−1, respectively.  相似文献   

10.
A simple, cost effective, and yet sensitive sample preparation technique was investigated for determining Polycyclic Aromatic Hydrocarbons (PAHs) in solid samples. The method comprises ultrasonic extraction, Stir Bar Sorptive Extraction (SBSE), and thermal desorption–gas chromatography–mass spectrometry to increase analytical capacity in laboratories. This method required no clean-up, satisfied PAHs recovery, and significantly advances cost performance over conventional extraction methods, such as Soxhlet and Microwave Assisted Extraction (MAE). This study evaluated three operational parameters for ultrasonic extraction: solvent composition, extraction time, and sample load. A standard material, SRM 1649 a (urban dust), was used as the solid sample matrix, and 12 priority PAHs on the US Environmental Protection Agency (US EPA) list were analyzed. Combination of non-polar and polar solvents ameliorated extraction efficiency. Acetone/hexane mixtures of 2:3 and 1:1 (v/v) gave the most satisfactory results: recoveries ranged from 63.3% to 122%. Single composition solvents (methanol, hexane, and dichloromethane) showed fewer recoveries. Comparing 20 min with 60 min sonication, longer sonication diminished extraction efficiencies in general. Furthermore, sample load became a critical factor in certain solvent systems, particularly MeOH. MAE was also compared to the ultrasonic extraction, and results determined that the 20-min ultrasonic extraction using acetone/hexane (2:3, v/v) was as potent as MAE. The SBSE method using 20 mL of 30% alcohol-fortified solution rendered a limit of detection ranging from 1.7 to 32 ng L−1 and a limit of quantitation ranging from 5.8 to 110 ng L−1 for the 16 US EPA PAHs.  相似文献   

11.
A simple and rapid dispersive liquid-liquid microextraction procedure based on an ionic liquid (IL-DLLME) was developed for selective determination of cobalt (Co) with electrothermal atomic absorption spectrometry (ETAAS) detection. Cobalt was initially complexed with 1-nitroso-2-naphtol (1N2N) reagent at pH 4.0. The IL-DLLME procedure was then performed by using a few microliters of the room temperature ionic liquid (RTIL) 1-hexyl-3-methylimidazolium hexafluorophosphate [C6mim][PF6] as extractant while methanol was the dispersant solvent. After microextraction procedure, the Co-enriched RTIL phase was solubilized in methanol and directly injected into the graphite furnace. The effect of several variables on Co-1N2N complex formation, extraction with the dispersed RTIL phase, and analyte detection with ETAAS, was carefully studied in this work. An enrichment factor of 120 was obtained with only 6 mL of sample solution and under optimal experimental conditions. The resultant limit of detection (LOD) was 3.8 ng L−1, while the relative standard deviation (RSD) was 3.4% (at 1 μg L−1 Co level and n = 10), calculated from the peak height of absorbance signals. The accuracy of the proposed methodology was tested by analysis of a certified reference material. The method was successfully applied for the determination of Co in environmental and biological samples.  相似文献   

12.
A simple procedure for the determination of manganese in different sections of human brain samples by graphite furnace atomic absorption spectrometry has been developed. Brain sections included cerebellum, hypothalamus, frontal cortex, vermix and encephalic trunk. Two sample preparation procedures were evaluated, namely, slurry sampling and microwave-assisted acid digestion. Brain slurries (2% w/v) could be prepared in distilled, de-ionized water, with good stability for up to 30 min. Brain samples were also digested in a domestic microwave oven using 5 ml of concentrated HNO3. A mixed palladium+magnesium nitrate chemical modifier was used for thermal stabilization of the analyte in the electrothermal atomizer up to pyrolysis temperatures of 1300 °C, irrespective of the matrix. Quantitation of manganese was conducted in both cases by means of aqueous standards calibration. The detection limits were 0.3 and 0.4 ng ml−1 for the slurry and the digested samples, respectively. The accuracy of the procedure was checked by comparing the results obtained in the analysis of slurries and digested brain samples, and by analysis of the NIST Bovine Liver standard reference material (SRM 1577a). The ease of slurry preparation, together with the conventional set of analytical and instrumental conditions selected for the determination of manganese make such methodology suitable for routine clinical applications.  相似文献   

13.
Continuous flow (CF) chemical hydride generation (CHG) and electrochemical hydride generation (ECHG) directly coupled to a novel 40 W, atmospheric pressure, 2.45 GHz microwave microstrip Ar plasma exiting a microstrip wafer has been developed for the emission spectrometric determination of As and Sb using a miniaturized optical fiber spectrometer and a CCD-array detector. The experimental conditions for both procedures were optimized with respect to the relative net intensities of the As I 228.8 nm and Sb I 252.8 nm lines and their signal-to-background intensity ratios. Additionally, the susceptibility to interferences from Cd, Co, Cr, Cu, Fe, Ni, Pb and Zn and other hydride-forming elements in the determination of As and Sb using the CHG and ECHG techniques was investigated in detail. Under the optimized conditions, it was found that ECHG is more prone to interferences compared to CHG. The detection limits (3σ) of As (6 ng mL−1) and Sb (7 ng mL−1) obtained for the ECHG-MSP-OES method are about three times lower than in the case of the CHG-MSP-OES method due to a two-fold lower amount of H2 introduced into the MSP in case of the ECHG, resulting in a better plasma stability and reduced background level. The linearity ranges for both calibration curves to a concentration of up to 5 μg mL−1 and a precision between 2% and 7% (2 μg mL−1 and 0.050 μg mL−1 of As and Sb, respectively) were found for both methods. The developed ECHG-MSP-OES method was validated for As through the analysis of a certified coal fly ash standard reference material (NIST SRM 1633a) after sample dissolution. The derived concentration (140 ± 8 μg g−1) was found to agree well with the certified data (145 ± 15 μg g−1). The method was also successfully applied to the analysis of both a galvanic bath sample, which contained Sb and was spiked with As, and a tap water sample spiked with both analytes. Recovery rates of 99-101% and a Sb concentration of 6.6 μg mL−1 in the galvanic bath sample were revealed. The latter value showed a good agreement with the data obtained from ICP-OES analysis, which was also used for validation purpose.  相似文献   

14.
Fast-heating programmes for determining titanium and tin in soils, sediments and sludges using electrothermal atomic absorption spectrometry (ETAAS) with slurry sampling are developed. For titanium determination, suspensions are prepared by weighing 5-40 mg of sample and adding 25 ml of a solution containing 50% (v/v) concentrated hydrofluoric acid. For tin determination, suspensions are prepared by weighing up to 300 mg of sample and then adding 1 ml of a solution containing 25% (v/v) concentrated hydrofluoric acid. Palladium (30 μg) and ammonium dihydrogen phosphate (7% w/v) are used as matrix modifiers for titanium and tin, respectively. Prior mild heating in a microwave oven is recommended for titanium determination. Calibration is carried out using aqueous standards. The tin and titanium contents of a number of samples obtained by using the slurry approach agree with those obtained by means of a procedure based on the total dissolution of the samples using microwave oven digestion. The reliability of the procedures is also confirmed by analysing several certified reference materials.  相似文献   

15.
A slurry sampling inductively coupled plasma mass spectrometry (ICP-MS) method has been developed for the determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions using flow injection (FI) vapor generation (VG) as the sample introduction system. A slurry containing 2% m/v lotion, 2% m/v thiourea, 0.05% m/v l-cysteine, 0.5 μg mL−1 Co(II), 0.1% m/v Triton X-100 and 1.2% v/v HCl was injected into a VG-ICP-MS system for the determination of Ge, As, Cd, Sb, Hg and Bi without dissolution and mineralization. Because the sensitivities of the analytes in the slurry and that of aqueous solution were quite different, an isotope dilution method and a standard addition method were used for the determination. This method has been validated by the determination of Ge, As, Cd, Sb, Hg and Bi in GBW09305 Cosmetic (Cream) reference material. The method was also applied for the determination of Ge, As, Cd, Sb, Hg and Bi in three cosmetic lotion samples obtained locally. The analysis results of the reference material agreed with the certified value and/or ETV-ICP-MS results. The detection limit estimated from the standard addition curve was 0.025, 0.1, 0.2, 0.1, 0.15, and 0.03 ng  g−1 for Ge, As, Cd, Sb, Hg and Bi, respectively, in original cosmetic lotion sample.  相似文献   

16.
Continuous flow chemical hydride generation coupled directly to a 40 W, atmospheric pressure, 2.45 GHz microwave microstrip Ar plasma operated inside a capillary channel in a sapphire wafer has been optimized for the emission spectrometric determination of As and Sb. The effect of the NaBH4 concentration, the concentration of HCl, HNO3 and H2SO4 used for sample acidification, the Ar flow rate, the reagent flow rates, the liquid volume in the separator as well as the presence of interfering metals such as Fe, Cu, Ni, Co, Zn, Cd, Mn, Pb and Cr, was investigated in detail. A considerable influence of Fe(III) (enhancement of up to 50 %) for As(V) and of Fe(III), Cu(II) and Cr(III) (suppression of up to 75%) as well as of Cd(II) and Mn(II) (suppression by up to 25%) for Sb(III) was found to occur, which did not change by more than a factor of 2 in the concentration range of 2–20 μg ml− 1. The microstrip plasma tolerated the introduction of 4.2 ml min− 1 of H2 in the Ar working gas, which corresponded to an H2/Ar ratio of 28%. Under these conditions, the excitation temperature as measured with Ar atom lines and the electron number density as determined from the Stark broadening of the Hβ line was of the order of 5500 K and 1.50 · 1014 cm− 3, respectively. Detection limits (3σ) of 18 ng ml− 1 for As and 31 ng ml− 1 for Sb were found and the calibration curves were linear over 2 orders of magnitude. With the procedure developed As and Sb could be determined at the 45 and 6.4 μg ml− 1 level in a galvanic bath solution containing 2.5% of NiSO4. Additionally, As was determined in a coal fly ash reference material (NIST SRM 1633a) with a certified concentration of As of 145 ± 15 μg g− 1 and a value of 144 ± 4 μg g− 1 was found.  相似文献   

17.
A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L min−1, auxiliary gas flow of 0.2 L min−1 and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-assisted method developed is highly comparable with the microwave digestion method standardized by the United States Environmental Protection Agency (EPA-3052). The ultrasound-assisted digestion with a digestion solution of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 81%. One exception is arsenic which resulted in recoveries of about 60% only; however, it could be digested with good recovery (>90%) using a digestion solution of 5 mL of water and 5 mL of aqua regia. The major advantage of the ultrasound-assisted digestion over microwave digestion is the high treatment rate (30 samples simultaneously with a sonication time of 18 min).  相似文献   

18.
Profumo A  Spini G  Cucca L  Pesavento M 《Talanta》2002,57(5):929-934
A sequential extraction procedure for separating and determining Be(0), soluble Be(II) inorganic compounds, BeO and beryllium silicates in samples such as particulate matter of emissions and working areas, has been developed. The proposed procedure has been tested on synthetic samples prepared with the inorganic beryllium compounds, in the presence of atmospherical particulate matter sampled in a laboratory of the Department, previously checked for the absence of beryllium. The speciation was then repeated on a sample of fly ash deriving from a solid waste incinerator and on a reference material (Coal Fly ash SRM 1633a, by NIST), followed by an evaluation of matrix spiking and recovery analyses. Performing multiple analyses of the spiked samples assessed the repeatability of the procedure. Quantitative determinations have been made by inductively coupled plasma optical emission spectrometry (ICP-OES) and electrothermal atomic absorption spectrometry (ETAAS). The possible interferences of the most common ions have been investigated. The selective sequential extractions allow one to separate and to determine different inorganic beryllium species, to which a different toxicity and therefore, a different risk are related: it is the case for example of metallic beryllium and beryllium oxide.  相似文献   

19.
Determination of inorganic oxyanions of As and Se by HPLC-ICPMS   总被引:1,自引:0,他引:1  
Sathrugnan K  Hirata S 《Talanta》2004,64(1):237-243
A liquid chromatographic separation of inorganic oxyanions of As (As(V) and As(III)) and Se (Se(VI) and Se(IV)) using mixed ion-pairing reagents followed by ICPMS detection is described. The separation was accomplished in less than 4 min on Capcell C18 RP column using mixed ion-pairing modifier containing 5 mM of butane sulfonic acid (BSA), 2 mM malonic acid, 0.30 mM hexane sulfonic acid (HSA) and 0.5% methanol of pH 2.5. All four species were resolved with retention times of 2.4, 2.6, 3.0, and 3.1 min for Se(VI), As(V), As(III), and Se(IV), respectively. The detection limits were less than 0.08 and 0.77 μg l−1 for arsenic and selenium species, respectively. The relative standard deviation of the proposed method for arsenic (at 2.5 μg l−1) and selenium (at 10 μg l−1) was less than 3.7 and 4.8%, respectively. The technique was used to determine inorganic oxyanions of As and Se in water samples (tap, well, and river) and extracts of coal fly ash and sediment. Low power microwave digestion was employed for extraction from fly ash and sediment samples.  相似文献   

20.
A slurry sampling method has been developed for the determination of Pb in marine plankton by ETAAS using a freshwater plankton certified reference material (CRM 414). Slurries were prepared in 1–3% m/v range with 1% v/v HNO3 by ultrasonic agitation for 5 min. The effects of several chemical modifiers, including Ir(NO3)2, Mg(NO3)2, Pd(NO3)2, Pd(NO3)2 + Mg(NO3)2, and Mg(NO3)2 + NH4H2PO4, were investigated for the stabilization of Pb during thermal pretreatment. Lead in slurries was effectively stabilized up to 1000 °C with Ir, Pd and Pd + Mg modifiers among which Pd + Mg provided the best results with complete atomization at 1850 °C. Firings in the presence of Ir were, problematic due to ash formation inside the atomizer. Water, dilute HNO3 and HF were examined as suspension medium. Dilute HNO3 (1–2% v/v) proved to be advantageous over water as it afforded extraction of Pb from plankton almost quantitatively in 5 min agitation. Hydrofluoric acid was the least suitable medium. Increasing HF concentration up to 5% v/v resulted in inaccuracy and substantial background absorption. Fast-heating furnace method provided comparable accuracy and precision to that of conventional-heating in slurries of CRM 414. Detection limits and characteristic masses were, respectively, 0.49 μg L− 1 and 32 pg for the conventional method and 0.62 μg L− 1 and 37 pg for the fast-heating method. However, fast-heating approach suffered from distorted peaks at high temperatures and incomplete pyrolysis of matrix at lower temperatures. Analysis of marine plankton samples for Pb was performed by using the conventional furnace program. The results showed a high correlation with those obtained by solution ICP-MS. Differences were statistically insignificant within 95% confidence interval.  相似文献   