1.
A complete electrochemical study and a novel electroanalytical procedure for bromhexine quantitation are described. Bromhexine in methanol/0.1 mol L−1 Britton–Robinson buffer solution (2.5/97.5) shows an anodic response on glassy carbon electrode between pH 2 and 7.5. By DPV and CV, both peak potential and current peak values were pH-dependent in all the pH range studied. A break at pH 5.5 in EP versus pH plot revealing a protonation–deprotonation (pKa) equilibrium of bromhexine was observed. Spectrophotometrically, an apparent pKa value of 4.3 was also determined.

An electrodic mechanism involving the oxidation of bromhexine via two-electrons and two-protons was proposed. Controlled potential electrolysis followed by HPLC–UV and GC–MS permitted the identification of three oxidation products: N-methylcyclohexanamine, 2-amino-3,5-dibromobenzaldehyde and 2,4,8,10-tetrabromo dibenzo[b,f][1,5] diazocine.

DPV at pH 2 was selected as optimal pH for analytical purposes. Repeatability, reproducibility and selectivity parameters were adequate to quantify bromhexine in pharmaceutical forms. The recovery was 94.50 ± 2.03% and the detection and quantitation limits were 1.4 × 10−5 and 1.6 × 10−5 mol L−1, respectively. Furthermore, the DPV method was applied successfully to individual tablet assay in order to verify the uniformity content of bromhexine. No special treatment of sample were required due to excipients do not interfered with the analytical signal. Finally the method was not time-consuming and less expensive than the HPLC one.  相似文献   


2.
C. Velasco-Aguirre 《Talanta》2010,82(2):796-4507
The electrochemical behavior and the analytical application of the selective serotonin agonist naratriptan (N-methyl-3-(1-methyl-4-piperidyl)indole-5-ethanesulfonamide) are presented herein. Naratriptan exhibits an anodic response in aqueous media over a broad pH range (pH 2-12), as determined by differential pulse voltammetry and cyclic voltammetry using glassy carbon electrodes. This response is irreversible in nature, diffusion-controlled and probably caused by the oxidation of the naratriptan indole moiety. The differential pulse voltammetry technique was performed in 0.1 mol L−1 Britton-Robinson buffer (pH = 3), which elicited the most reproducible results. The percentage of naratriptan recovery was 102.1 ± 1.8%, and the limits of detection and quantitation were 9.5 × 10−6 and 2.0 × 10−5 mol L−1, respectively. Selectivity trials revealed that the oxidation signal of the drug was not disturbed by the presence of excipients or degradation products. Thus, we conclude that the method presented herein is useful for the quantification of naratriptan in pharmaceutical drugs and that this method requires no separations or extractions. Finally, this voltammetric method was successfully applied to determine the quantity and the content uniformity of naratriptan in drug tablets. A comparison of this technique to the standard high-performance liquid chromatography technique was conducted at the end of our study.  相似文献   

3.
The oxidative behaviour of moxifloxacin was studied at a glassy carbon electrode in different buffer systems using cyclic, differential pulse, and Osteryoung square-wave voltammetry. The oxidation process was shown to be irreversible over the entire pH range studied (2.0–10.0) and was diffusion-controlled. The methods were performed in Britton–Robinson buffer and the corresponding calibration graphs were constructed and statistical data were evaluated. When the proposed methods were applied at pH 6.0 linearity was achieved from 4.4×10–7 to 1.0×10–5 mol L–1. Applicability to tablets and human plasma analysis was illustrated. Furthermore, a high-performance liquid chromatographic method with diode-array detection was developed. A calibration graph was established from 4.0×10–6 to 5.0×10–5 mol L–1 moxifloxacin. The described methods were successfully employed with high precision and accuracy for estimation of the total drug content of human plasma and for pharmaceutical dosage forms of moxifloxacin.  相似文献   

4.
《Electroanalysis》2006,18(7):655-661
In this paper, the possibility of analyzing levodopa and carbidopa by differential pulse voltammetry (DPV) utilizing a glassy carbon electrode in 0.1 mol L?1 HClO4 is reported. Cyclic voltammograms of levodopa show a redox couple with anodic and cathodic peak potentials at 0.58 V and 0.52 V (vs. Ag/AgCl), respectively. For carbidopa, there are two oxidation waves with maximum currents at 0.53 V and 1.02 V, without any cathodic counterpart at slow enough scan rate. Since in such conditions, the oxidation product of carbidopa does not undergo reduction, it is possible to analyze levodopa without interference. On the other hand, carbidopa can be determined between 0.85 V and 1.1 V in the presence of levodopa, coating the electrode with a Nafion film, which is selective for carbidopa. The developed methodology was applied to two different commercial samples of pharmaceutical products. The obtained data were compared with the results of the analysis by high performance liquid chromatography (HPLC) with UV detection, showing good correlation (relative errors changing between 0.4% and 3.5%) and absence of interference of the other components that accompanied the pharmaceuticals.  相似文献   

5.
Conventional (CPE) and miniaturized (m‐CPE) carbon paste electrodes consisting of a carbon paste filled capillary were used for differential pulse voltammetric determination of chlortoluron in samples of river water and soil, in the latter case after the extraction by methanol. Britton‐Robinson buffer pH 3 with low content of methanol was found to be optimal for the determination. The achieved determination limits were 2.8 µmol L?1 and 0.34 µmol L?1 in river water, and 3.1 and 4.3 µg g?1 in soil, using CPE and m‐CPE, respectively.  相似文献   

6.
土壤中多种有机氯及拟除虫菊酯类农药的GC-ECD测定   总被引:1,自引:0,他引:1  
气相色谱法同时测定土壤中多种有机氯及拟除虫菊酯类农药。对土壤的分析结果:有机氯农药的检出限0.001~0、003μg/mL,拟除虫菊酯类农药检出限0.008~0.02μg/mL,线性相关系数0.9978~0.9999。用y(石油醚):V(丙酮)=3:1超声波提取,有机氯农药回收率94.2%~124.0%,相对标准偏差为3.3%~8.8%(n=5);拟除虫菊酯类农药回收率95.2%~118.3%,相对标准偏差为5.7%~7.1%(n=5);方法适用于土壤样品中农药残留测定。  相似文献   

7.
Torriero AA  Luco JM  Sereno L  Raba J 《Talanta》2004,62(2):247-254
The electrochemical oxidation of salicylic acid (SA) has been studied on a glassy carbon electrode using cyclic voltammetry and differential pulse voltammetric (DPV) method. SA gives a single irreversible oxidation wave over the wide pH range studied. The irreversibility of the electrode process was verified by different criteria. The mechanism of oxidation is discussed. Using differential pulse voltammetry, SA yielded a well-defined voltammetric response in Britton-Robinson buffer solution, pH 2.37 at 1.088 V (versus Ag/AgCl). The method was linear over the SA concentration range: 1-60 μg ml−1. The method was successfully applied for the analysis of SA as a hydrolysis product, in solid pharmaceutical formulations containing acetylsalicylic acid (ASA).  相似文献   

8.
A new differential pulse voltammetric method for dopamine determination at a bare glassy carbon electrode has been developed. Dopamine, ascorbic acid (AA) and uric acid (UA) usually coexist in physiological samples. Because AA and UA can be oxidized at potentials close to that of DA it is difficult to determine dopamine electrochemically, although resolution can be achieved using modified electrodes. Additionally, oxidized dopamine mediates AA oxidation and the electrode surface can be easily fouled by the AA oxidation product. In this work a chemometrics strategy, partial least squares (PLS) regression, has been applied to determine dopamine in the presence of AA and UA without electrode modification. The method is based on the electrooxidation of dopamine at a glassy carbon electrode in pH 7 phosphate buffer. The dopamine calibration curve was linear over the range of 1–313 μM and the limit of detection was 0.25 μM. The relative standard error (RSE %) was 5.28%. The method has been successfully applied to the measurement of dopamine in human plasma and urine.   相似文献   

9.
Cyclic voltammetry was used to investigate the electrochemical behaviour of triclosan (2,2,4′-trichloro-2′-hydroxydiphenyl ether) at a screen-printed carbon electrode (SPCE). It was found that a single anodic peak occurred over the pH range 6.0–12.0; this peak was considered to result from an irreversible oxidation reaction at the phenolic moiety. A plot of Ep versus pH was constructed and from the break point a pKa value of 7.9 was obtained, thus agreeing with the literature value. Detailed voltammetric studies were performed at pH 10, where the analyte exists as an anion. It was demonstrated that, at an initial potential of 0 V, the anion underwent electrosorption prior to electrochemical oxidation. The oxidation reaction appeared to involve a one-electron transfer, as deduced from a calculated na value of 0.5; the same value was obtained at pH 7.0. In contrast to triclosan, triclosan monophosphate was found to be electrochemically inactive when subjected to voltammetry under the stated conditions.

The electrochemical oxidation of triclosan at a SPCE was exploited for its determination (0.3%) in commercial toothpaste and mouthrinse products using differential pulse voltammetry. The recovery and precision data indicated that this approach may have application in routine quality control analysis.  相似文献   


10.
M. Pérez-Ortiz 《Talanta》2010,82(1):398-630
In this work, the electrochemical behavior and the analytical application of atomoxetine, a selective noradrenaline reuptake inhibitor, are studied. Atomoxetine, studied by differential pulse voltammetry and cyclic voltammetry on a glassy carbon electrode, exhibited an anodic response in aqueous media with pH between 1.5 and 7. In non-aqueous medium (acetonitrile), the drug exhibited two irreversible oxidation peaks that are diffusion controlled. From chronocoulometric studies in acetonitrile, it was determined that each oxidation signal involves two and four electrons, respectively. For analytical purposes, a differential pulse voltammetry technique in 0.1 mol L−1 perchloric acid was selected, which exhibited adequate figures of merit. The percent recovery was 96.6 ± 1.2 and the detection and quantitation limits were 6.9 × 10−5 and 1.0 × 10−4 mol L−1, respectively. Also, results indicate that excipients do not interfere with the oxidation signal of atomoxetine, which leads to the conclusion that the developed method is satisfactorily selective for atomoxetine quantification in pharmaceuticals with no prior separation or extraction necessary. Finally, the proposed voltammetric method was successfully applied to both the assay and the uniformity content of atomoxetine in capsules. For comparison, high-performance liquid chromatography analysis was also performed.  相似文献   

11.
《Analytical letters》2012,45(9):1683-1698
For the first time, a simple differential pulse voltammetry methodology for direct determination of benserazide in presence of levodopa in tablets was developed without any redox mediator, modified electrodes, or the aplication of mathematic deconvolution of signals. Benserazide was studied by differential pulse voltammetry using glassy carbon electrode in aqueous media. The drug exhibited a main well-defined oxidation signal in a broad pH range (2–10), and two poorly resolved signals at higher potentials. We have found that levodopa does not interfere on the electrochemical response of benserazide at pH 6.0. Thus, at this pH value, the developed analytical method exhibited adequate repeatability and reproducibility (RSD < 2%), recoveries >98.5%, which permitted its successful application to both the assay and the uniformity content of benserazide. Also, hydrolytic degradation studies of benserazide were carried out by differential pulse voltammetry.  相似文献   

12.
聚磺胺嘧啶修饰电极伏安法测定对乙酰氨基酚   总被引:1,自引:0,他引:1  
利用循环伏安法制备了聚磺胺嘧啶修饰电极, 研究了对乙酰氨基酚在该修饰电极上的电化学行为. 该电极对对乙酰氨基酚有较强的电催化作用. 在pH 9.0的PBS缓冲溶液中, 用循环伏安法和差分脉冲伏安法在该电极上测定了对乙酰氨基酚, 其线性范围分别为4.0×10-6~3.0×10-4 mol/L和2.0×10-7~1.0×10-5 mol/L, 检出限分别为9.0×10-7 mol/L和8.0×10-8 mol/L.  相似文献   

13.
磷酸可待因在Nafion修饰玻碳电极上的伏安行为研究及测定   总被引:1,自引:1,他引:0  
用循环伏安法和微分脉冲吸附伏安法对磷酸可待因在Nafion修饰玻碳电极上的伏安行为进行了研究。结果表明在 0 .1mol/LHCl底液中 ,磷酸可待因在 + 1 .0 6V处 (vs.SCE)产生一良好的氧化峰 ,磷酸可待因浓度在 5 .0× 1 0 - 7~2 .5× 1 0 - 5mol/L范围内与峰电流呈线性关系 ,检出限为 1 .3× 1 0 - 7mol/L。并分别对其单方药和复方药制剂进行了测定  相似文献   

14.
The preconcentration and voltammetric behavior of BiIII on a sodium humate modified carbon paste electrode was studied by means of cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV). The proposed measurement involves an initial nonelectrolytic preconcentration step in which BiIII is complexed by the surface modifier in a solution of 0.05 M KNO3-0.0106 M HNO3 (pH 2.0) and a subsequent electrochemical scan step in which the preconcentrated BiIII was reduced and then oxidized promptly in supporting electrolyte of 0.5 M HNO3. The resulting DPSV anodic current was proportional to the concentration of BiIII ion over the range of 4.78 × 10−8–1.44 × 10−5 M. The detection limit was 4.78 × 10−8 M. The proposed method was used to determine bismuth in various samples. Various factors affecting the electrode behavior were also investigated at the same time.  相似文献   

15.
Dejmkova H  Stoica AI  Barek J  Zima J 《Talanta》2011,85(5):2594-2598
Methods for determination of 2-amino-4-nitrophenol and 4-amino-2-nitrophenol, metabolites of 2,4-dinitrophenol, were developed using differential pulse (DP) voltammetry and HPLC with amperometric and spectrophotometric detection. The applicability of these methods was tested by the determination of the analytes in model samples of urine after preliminary separation by solid-phase extraction. Voltammetry enabled parallel determination of both analytes, but its application in real matrix was severely limited due to the interference of other compounds present in urine. HPLC allowed the determination in real urine matrix down to micromolar concentrations; amperometric detection proved to be more sensitive and selective than the spectrophotometric one.  相似文献   

16.
The adsorptive voltammetric behavior of resveratrol was studied at a graphite electrode in B‐R buffer (pH = 6.0) solution using adsorptive cyclic voltammetric technique. The oxidation of resveratrol is an irreversible adsorption controlled process. The oxidation mechanism was proposed and discussed in this work. The dependence of the current on pH and the concentration and nature of buffer were investigated to optimize the experimental conditions for the determination of resveratrol. It was found that in the range of 8.0 × 10?9 ~ 2.0 × 10?6 mol/L, the currents measured by differential pulse voltammetries presented a good linear property as a function of the concentrations of resveratrol. In addition, validation parameters, such as reproducibility, sensitivity and recovery were evaluated as well. The proposed method was also successfully applied for the determination of resveratrol in Chinese patent medicine with good results.  相似文献   

17.
《Analytical letters》2012,45(23-24):2307-2315
Abstract

Trazodone, a triazolopyridine derivative with antidepressant activity, is irreversibly oxidized in two steps in a large range of scan rates. The first peak shows a linear dependence on trazodone concentration. This behaviour is used for analytical purposes in determining trazodone concentrations in commercial preparations. An original alternative gas-liquid chromatographic method is also developed. Comparison of the chromatographic with voltammetric methods shows that a) both are sensitive enough to be applied to single tablet assays; b) the major advantage of the voltammetric method for analytical purposes lies in the rapid determination of the trazodone content in tablets. Preparation of the samples is easy and no extraction procedure is required.  相似文献   

18.
Zhang L  Zhang S  Wan Y 《Talanta》2003,59(5):1009-1013
A well derivative reduction wave of methaqualonc (MTQ) was obtained in 0.033 mol dm−3 B-R (pH 3.76) buffer solution by single-sweep oscillopolarography. The peak potential is −1.36 V (vs. saturated calomel reference electrode, SCE). The peak current is proportional to the concentration of methaqualone over the range of 7.0×10−8-9.0×10−6 mol dm−3. The method has been successfully applied to the determination of methaqualone in tablets. The wave is believed to result from irreversible adsorption through studies of its electrochemical behavior and reaction mechanism.  相似文献   

19.
Differential pulse stripping voltammetry method(DPSV) was applied to the determination of three herbicides,ametryn,cyanatryn,and dimethametryn.It was found that their voltammograms overlapped strongly,and it is difficult to determine these compounds individually from their mixtures.With the aid of chemometrics,classical least squares(CLS),principal component regression(PCR) and partial least squares(PLS),voltammogram resolution and quantitative analysis of the synthetic mixtures of the three compounds were successfully performed.The proposed method was also applied to the analysis of some real samples with satisfactory results.  相似文献   

20.
The reduction of 4-nitrophenol (4-NP) has been carried out on a modified glassy carbon electrode using cyclic and differential pulse voltammetry (DPV). The sensor was prepared by modifying the electrode with lithium tetracyanoethylenide (LiTCNE) and poly-l-lysine (PLL) film. With this modified electrode 4-NP was reduced at −0.7 V versus SCE. The sensor presented better performance in 0.1 mol l−1 acetate buffer at pH 4.0. The other experimental parameters, such as concentration of LiTCNE and PLL, pulse amplitude and scan rate were optimized. Under optimized operational conditions, a linear response range from 27 up to 23200 nmol l−1 was obtained with a sensitivity of 3.057 nA l nmol−1 cm−2. The detection limit for 4-NP determination was 7.5 nmol l−1. The proposed sensor presented good repeatability, evaluated in term of relative standard deviation (R.S.D.=4.4%) for n=10 and was applied for 4-NP determination in water samples. The average recovery for these samples was 103.0 (± 0.7)%.  相似文献   