G. J. Dear D. N. Mallett D. M. Higton A. D. Roberts S. A. Bird H. Young R. S. Plumb I. M. Ismail 《Chromatographia》2002,55(3-4):177-184
Summary In this paper we investigate the potential of alkyl-bonded silica monolithic columns for the isolation and identification
of drug-related components in biological fluids. Up to 6 columns have been connected in series to produce a chromatographic
system with up to 40,000 plates. This high-resolution chromatography system has been coupled to both MS and NMR to enable
efficient detection and characterisation of drug-related components in biological fluids. The use of six coupled columns has
been shown to give enhanced resolution over a high quality silica particulate column packed with 3 μm material which exhibits
the same back pressure. The effect of volume and mass load on the performance of monolithic columns for semi-preparative chromatography
of biological fluids has also been investigated. In these studies it was possible to inject up to 100 mL of neat urine with
no loss of chromatographic performance. Furthermore, upon re-testing, the columns showed similar chromatographic performance.
Again several columns were serially connected, producing enhanced resolution in the semi-preparative mode. 相似文献
2.
Gerber F Krummen M Potgeter H Roth A Siffrin C Spoendlin C 《Journal of chromatography. A》2004,1036(2):127-133
The potential and limitations of fast reversed-phase high-performance liquid chromatographic separations for assay and purity of drug substances and drug products were investigated in the pharmaceutical industry working under current good manufacturing practice using particle packed columns and monolithic columns. On particle packed columns, the pressure limitation of commercially available HPLC systems was found to be the limiting factor for fast separations. On 3 microm particle packed columns, HPLC run times (run to run) for assay and purity of pharmaceutical products of 20 min could be achieved. As an interesting alternative, monolithic columns were investigated. Monolithic columns can be operated at much higher flow rates, thus allowing for much shorter run times compared to particle packed columns. Compared to particle packed columns, the analysis time could be reduced by a factor up to 6. However, some compounds investigated showed a dramatic loss of efficiency at higher flow rates. This phenomenon was observed for some larger molecules supporting the theory that mass transfer is critical for applications on monolithic columns. At flow rates above 3 ml/min some HPLC instruments showed a dramatic increase in noise, making quantifications at low levels impossible. For very fast separations on monolithic columns, the maximum data acquisition rate of the detector is the limiting factor. 相似文献
3.
Since the appearance of monolithic silica, much work has been done describing the properties of monolithic silica columns. Meanwhile the transferability of analytical methods from conventional to monolithic silica columns has been intensively investigated [1-5]. RP HPLC method development strategies for conventional columns should be updated or scaled to meet the higher performing monolithic column technology. Because of the high permeability of monolithic silica columns it should be possible to decrease the time for method development by applying high isocratic flow rates. Here we suggest a clear strategy for method development using monolithic columns. The strategy will be applicable for various sample compositions, e. g., acidic, basic, or neutral. The applicability of monolithic columns for especially complex separations of basic mixtures without the need of using a highly basic mobile phase that harms the column will be pointed out in this work. This work will describe in detail the actual method development process. For better understanding of our strategy, the influence of flow rate, column length, mobile phase composition, pH, and temperature will be discussed. Details about the application of a flow program will be mentioned. 相似文献
4.
Fast HPLC methods are becoming more and more important. Using monolithic HPLC columns for fast separations, a flow program can be applied for further decrease in the total run time. An interesting issue was whether the flow program affects repeatability. The investigated method was a generic assay for the oral antidiabetic drugs glibenclamide and glimepiride in the presence of two of their degradation products. A flow program ranging from 5.0 to 9.9 mL/min had been set up to decrease the run time to approximately 1.7 min. Within-day RSD% (n = 40) for both retention times and peak areas were less than 1%. At flow rates higher than 7 mL/min, repeatability was impaired to some extent. It became mainly noticeable through the day-to-day precision (n = 60) which showed RSD% up to 2%. However, further investigations indicated that this was rather related to pump inefficiency at high flow rates than to the flow program as such. Presuming the use of appropriate equipment, qualified for high flow rates, the application of a flow program for shortening the run time is absolutely reasonable and does not affect repeatability. 相似文献
5.
6.
A novel monolithic capillary column (530 microm i.d.) was prepared for capillary liquid chromatography (CLC) by in situ copolymerization of octyl methacrylate (MAOE) and ethylene dimethacrylate (EDMA) in the presence of a porogen solvent containing 1-propanol, 1,4-butanediol, and water with azobisisobutyronitrile as the initiator. The influences of the contents of the porogen solvent, EDMA and the various concentration ratios of 1-propanol to 1,4-butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of monolithic capillary columns were characterized by SEM and mercury intrusion porosimetry, respectively. Chromatographic evaluations of the columns were performed under CLC mode. The results showed that good permeability and stability can be obtained under optimal experimental conditions. The separation results of some acid, neutral and basic analytes demonstrated the hydrophobicity and low affinity to basic analytes of the new column. Three metal ions, i.e. Mg(II), Zn(II) and Cd(II) were also separated under ion-pair mode on the new monolithic capillary column and the results were acceptable. 相似文献
7.
Dependence of monolithic column efficiency on column pressure was analyzed using modified Van Deemter relationship with incorporated inlet and outlet column pressures as independent variables. It was demonstrated that the highest column efficiency is observed at high pressures. Inlet and outlet pressure increase has to be controlled in such a way that the relative pressure approaches 1 and the pressure drop across the column is close to zero. Experimental results obtained for open and monolithic capillary columns confirm up to 50% higher column efficiency as compared to column efficiency under standard conditions found using conventional Van Deemter plot. Pressure increase also results in a decrease in the optimal carrier gas velocity and corresponding increase in the analysis time. This drawback can be compensated via an increase in the column temperature. 相似文献
8.
Eeltink S Wouters B Desmet G Ursem M Blinco D Kemp GD Treumann A 《Journal of chromatography. A》2011,1218(32):5504-5511
The separation of intact proteins, including protein isoforms arising from various amino-acid modifications, employing a poly(styrene-co-divinylbenzene) monolithic capillary column in high-performance liquid chromatography coupled on-line to a time-of-flight mass spectrometer (MS) is described. Using a 250 mm × 0.2 mm monolithic capillary column high-sensitivity separations yielding peak capacities of >600 were achieved with a 2h linear gradient and formic acid added in the mobile phase as ion-pairing agent. The combination of high-resolution chromatography with high-accuracy MS allowed to distinguish protein isoforms that differ only in their oxidation and biotinylation state allowing the separation between structural isoforms. Finally, the potential to separate proteins isoforms due to glycosylation is discussed. 相似文献
9.
Fast analysis of soy isoflavones by high-performance liquid chromatography with monolithic columns 总被引:1,自引:0,他引:1
A fast method using high-performance liquid chromatography based on two monolithic columns has been developed for the simultaneous determination of isoflavones extracted from soybeans and derived foods. The 12 main isoflavones were resolved in 10 min in two coupled monolithic columns working at 35 °C using a elution gradient of acidified water (0.1% acetic acid) and methanol (0.1% acetic acid) at a flow rate of 5 mL min−1. Retention time and relative area standard deviations were below 1% for all isoflavones. The method developed was successfully applied to several soy food samples and spiked samples. Total isoflavone concentration in sampled soy foods ranged from 34.28 mg L−1 to 4.29 mg g−1. 相似文献
10.
Summary Stainless steel columns (internally mirror-finished, 125 or 250nm in length, of bore 1.0 or 1.6mm) were slurry-packed with
5μm and 4μm reversed phase silicas (Hypersil ODS, LiChrosorb RP-8 and RP-18 and Superspher RP-8. The HPLC equipment consisted of a pump
LC5A (Shimadzu) or a pump 2150 (LKB Instruments), a rheodyne valve 7413 with loops of 0.5, 1.0 and 5.0mm3 and a Jasco-Uvidec 100-II UV detector, variously with one of three specially constructed cells of 0.2, 0.4 and 1.3mm3 volume. Columns were assembled using two types of coupling device employing a stainless steel capillary of 0.12mm bore. The
effect of sample volume, design of coupling device in assembled column, detector cell volume and geometry on column plate
count was examined to optimize the conditions and the instrument compartments. The highest efficiency for the assembled columns
was achieved by use of the 0.2mm3 detector cell, a low dead volume coupling device and a 0.5μl sample volume. Sets of 5 assembled columns gave reduced plate height values between 2–3 at a reduced velocity 2<v<3, indicating that extra-column effects were negligibly small; the performance was identical to that of conventional analytical
columns.
Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984 相似文献
11.
Christina Gatschelhofer Agnes Mautner Franz Reiter Thomas R. Pieber Michael R. Buchmeiser Frank M. Sinner 《Journal of chromatography. A》2009,1216(13):2651-2657
Functionalized monolithic columns were prepared via ring-opening metathesis polymerization (ROMP) within silanized fused silica capillaries with an internal diameter of 200 μm by in situ grafting. This procedure is conducted in two steps, the first of which is the formation of the basic monolithic structure by polymerization of norborn-2-ene (NBE) and 1,4,4a,5,8,8a-hexahydro-1,4,5,8-exo,endo-dimethanonaphthalene (DMN-H6) in a porogenic system (toluene and 2-propanol) using RuCl2(PCy3)2(CHPh) as ROMP initiator. In the second step the still active initiator sites located on the surface of the structure-forming microglobules were used as receptor groups for the attachment (“grafting”) of functional groups onto the monolithic backbone by flushing the monolith with 7-oxanorborn-2-ene-5,6-carboxylic anhydride (ONDCA). Functionalization conditions were first defined that did not damage the backbone of low polymer content (20%) monoliths allowing high-throughput chromatographic separations. Variation of the functionalization conditions was then shown to provide a means of controlling the degree of functionalization and resulting ion-exchange capacity. The maximum level of in situ ONDCA grafting was obtained by a 3 h polymerization in toluene at 40 °C. The weak cation-exchange monoliths obtained provided good separation of a standard peptide mixture comprising four synthetic peptides designed specifically for the evaluation of cation-exchange columns. An equivalent separation was also achieved using the lowest capacity column studied, indicative of a high degree of robustness of the functionalization procedure. As well as demonstrably bearing ionic functional groups enabling analyte separation in the cation-exchange mode, the columns exhibited additional hydrophobic characteristics which influenced the separation process. The functionalized monoliths thus represent useful tools for mixed-mode separations. 相似文献
12.
Erik Haghedooren 《Talanta》2009,78(3):665-671
The rise of monolithic stationary phases offers to routine and research laboratories several advantages. In spite of their recent discovery, they have rapidly become highly popular separation media for liquid chromatography. Time reduction and economic reasons like e.g. a diminished use of mobile phase are the most important ones. At the same time, it was reported that these columns offer a faster and better separation. The aim of this article was to investigate the transferability of methods originally developed on conventional particle-packed C18 columns (XTerra RP18 and Zorbax RX), onto the more recent monolithic columns. Both types, conventional particle-packed and monolithic columns, were able to separate tetracycline, oxytetracycline and chlortetracycline from their respective impurities with sufficient resolution, but showed remarkably shorter analysis times and lower backpressures, improving the lifetime of the column. 相似文献
13.
Erik L. Regalado 《Journal of separation science》2014,37(18):2552-2558
The term tmin cc provides a ready estimate of the shortest time that can be obtained by “column cutting” for baseline resolution of two components showing excess chromatographic resolution. While actual column cutting is impractical, the tmin cc value is shown to be closely related to the minimum separation time obtainable by adjusting other parameters such as flow rate, mobile phase composition, and temperature, affording scientists interested in the development of fast chromatographic separations a convenient tool for estimating the minimum separation time that can be obtained by modifying a given method development screening result. Furthermore, the relationship between tmin cc and the minimum separation time obtainable by adjusting other parameters is shown to be dependent on the speed of the screening method, with aggressive screening gradients affording tmin cc estimates that match the actual minimum separation time, and “lazy” screening gradients affording tmin cc values that overestimate minimum separation time. Consequently, the analysis of the relationship between tmin cc and actual minimum separation time may be a useful tool for determining the “fitness” of method development screening methods. 相似文献
14.
This work presents a fast method for the simultaneous separation and determination of glimepiride, glibenclamide, and two related substances by RP LC. The separation was performed on a Chromolith Performance (RP-18e, 100 mm x 4.6 mm) column. As mobile phase, a mixture of phosphate buffer pH 3, 7.4 mM, and ACN (55:45 v/v) was used. Column oven temperature was set to 30 degrees C. The total chromatographic run time was 80 s. This was achieved using a flow program from 5 to 9.9 mL/min. Precisions of the interday and the intraday assay for both retention times and peak areas for the four analyzed compounds were less than 1.2%. The method showed good linearity and recovery. The short analysis time makes the method very valuable for quality control and stability testing of drugs and their pharmaceutical preparations. 相似文献
15.
Wasura Soonthorntantikul Natchanun Leepipatpiboon Tohru Ikegami Nobuo Tanaka Thumnoon Nhujak 《Journal of chromatography. A》2009,1216(31):5868-5874
Stationary phase selectivities for halogenated compounds in reversed-phase HPLC were compared using C18 monolithic silica capillary columns modified with poly(octadecyl methacrylate) (ODM) and octadecyl moieties (ODS). The preferential retention of halogenated benzenes on ODM was observed in methanol/water and acetonitrile/water mobile phases. In selectivity comparison of selected analytes on ODM and ODS, greater selectivities for halogenated compounds were obtained with respect to alkylbenzenes on an ODM column, while similar selectivities were observed with a homologous series of alkylbenzenes on ODM and ODS columns. These data can be explained by greater dispersive interactions by more densely packed octadecyl groups on the ODM polymer coated column together with the contribution of carbonyl groups in ODM side chains. For the positional isomeric separation of dihalogenated benzenes (ortho-, meta-, para-), the ODM column also provided better separation of these isomers for the adjacently eluted isomers that cannot be completely separated on an ODS column in the same mobile phase. These results imply that the ODM column can be used as a better alternative to the ODS column for the separation of other halogenated compounds. 相似文献
16.
A simple capillary flow porometer (CFP) was assembled for through-pore structure characterization of monolithic capillary liquid chromatography columns in their original chromatographic forms. Determination of differential pressures and flow rates through dry and wet short capillary segments provided necessary information to determine the mean diameters and size distributions of the through-pores. The mean through-pore diameters of three capillary columns packed with 3, 5, and 7 μm spherical silica particles were determined to be 0.5, 1.0 and 1.4 μm, with distributions ranging from 0.1 to 0.7, 0.3 to 1.1 and 0.4 to 2.6 μm, respectively. Similarly, the mean through-pore diameters and size distributions of silica monoliths fabricated via phase separation by polymerization of tetramethoxysilane (TMOS) in the presence of poly(ethylene glycol) (PEG) verified that a greater number of through-pores with small diameters were prepared in columns with higher PEG content in the prepolymer mixture. The CFP system was also used to study the effects of column inner diameter and length on through-pore properties of polymeric monolithic columns. Typical monoliths based on butyl methacrylate (BMA) and poly(ethylene glycol) diacrylate (PEGDA) in capillary columns with different inner diameters (i.e., 50–250 μm) and lengths (i.e., 1.5–3.0 cm) were characterized. The results indicate that varying the inner diameter and/or the length of the column had little effect on the through-pore properties. Therefore, the through-pores are highly interconnected and their determination by CFP is independent of capillary length. 相似文献
17.
Moliner-Martínez Y Molins-Legua C Verdú-Andrés J Herráez-Hernández R Campíns-Falcó P 《Journal of chromatography. A》2011,1218(37):6256-6262
The performance of a monolithic C(18) column (150 mm×0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C(18) column (150 mm×0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorpyrifos (organophosphorous), diuron and isoproturon (phenylureas), trifluralin (dinitroaniline) and di(2-ethylhexyl)phthalate. The results obtained revealed that the monolithic column was clearly advantageous in the context of multiresidue organic pollutants analysis for a number of reasons: (i) the selectivity was considerably improved, which is of particular interest for the most polar compounds triazines and phenyl ureas that could not be resolved in the particulate column, (ii) the sensitivity was enhanced, and (iii) the time required for the chromatographic separation was substantially shortened. In this study it is also proved that the mobile-phase flow rates used for separation in the capillary monolithic column are compatible with the in-valve IT-SPME methodology using extractive capillaries of dimensions similar to those used in conventional scale liquid chromatography (LC). On the basis of these results a new method is presented for the assessment of pollutants in waters, which permits the characterization of whole samples (4 mL) in less than 30 min, with limits of detection in the range of 5-50 ng/L. 相似文献
18.
Monolithic silica capillary columns dynamically modified with quaternary ammonium ions were evaluated for the determination of bromide in seawater samples. A quaternary ammonium ion such as cetyltrimethylammonium ion was dynamically introduced onto monolithic silica surfaces. The first layer of the modifier was introduced by electrostatic interaction, whereas the second layer was introduced by hydrophobic interaction. The latter layer worked as the anion-exchange sites. The modified monolithic silica capillary columns could be used for rapid separation of inorganic anions. Separation of authentic mixture of five anions was achieved within a few minutes. The addition of small amount of the modifier in the eluent improved the repeatability of the retention time. Seawater samples could be directly injected onto the prepared capillary columns, and bromide could be determined to be 63 mg/L. 相似文献
19.
With applications that take advantage of highly selective fluorine–fluorine interactions appearing with greater frequency in the literature, the development of porous polymer monoliths from fluorous components is reported here for the purpose of chromatography of tagged analytes. With potential uses in fields as diverse as separation science and proteomics, facile fabrication of materials with fluorous specificity that can be applied in a high-throughput manner is greatly desirable. To this end, we have developed porous polymer capillary columns with varied fluorous content using a simple UV-initiated radical polymerization process and characterized them using flow-induced backpressure and scanning electron microscopy (SEM). With structural similarities assured (visually, and by backpressure variations of less than 42%), the monoliths were tested as chromatographic columns for the separation of a series of fluorous-tagged analytes under gradient conditions. It was found that columns made with fluorinated components exhibited greater selectivity for fluorous analytes than did equivalent, non-fluorinated monoliths, retaining analytes with either one or two fluorous tags for approximately 6% and 13% longer, respectively. This supports the idea of differences existing between fluorous and reverse-phase separation mechanisms, and encourages a broader range of potential applications for fluorous monoliths of this type. 相似文献
20.
Shu S Kobayashi H Kojima N Sabarudin A Umemura T 《Journal of chromatography. A》2011,1218(31):5228-5234
Poly(lauryl methacrylate-co-ethylene dimethacrylate) monoliths were in situ synthesized within the confines of a silicosteel tubing of 1.02 mm i.d. and 1/16" o.d. for microbore reversed-phase HPLC. In order to obtain practically useful monoliths with adequate column efficiency, low flow resistance, and good mechanical strength, some parameters such as total monomer concentration (%T), cross-linking degree (%C) and polymerization temperature were optimized. High-efficiency monoliths were successfully obtained by thermal polymerization of a monomer mixture (40%T, 10%C) with a binary porogenic solvent consisting of 1-propanol and 1,4-butandiol (7:4, v/v) at a high temperature of 90 °C. The morphology and porous structure of the resulting monoliths were assessed by scanning electron microscope (SEM) and inverse size exclusion chromatography (ISEC), while the column performance was evaluated through the separations of a series of alkylbenzenes in acetonitrile-water (50:50, v/v) eluent. At a normal flow rate of 50 μL/min (corresponding to 1.66 mm/s), the optimized monolithic columns typically exhibited theoretical plate numbers of 6000 plates/10 cm-long column for amylbenzene (k>40), and the pressure drop was always less than 1 MPa/10 cm. The monoliths, which were chemically anchored to the tube inner wall surface using a bifunctional silylation agent, exhibited adequate mechanical strength of up to 12-13 MPa, and were properly operated at 10 times higher flow rate than normal, reducing the separation time to one tenth. The lauryl methacrylate-based monolithic column was applied to a rapid and efficient separation of ten common proteins such as aprotinin, ribonuclease A, insulin, cytochrome c, trypsin, transferrin, conalbumin, myoglobin, β-amylase, and ovalbumin in the precipitation-redissolution mode. Using a linear CH(3)CN gradient elution at a flow rate of 500 μL/min (10-times higher flow rate), 10 proteins were baseline separated within 2 min. 相似文献