首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Heng LY  Toth K  Hall EA 《Talanta》2004,63(1):73-87
The ion-transport behaviour of methacrylic-acrylic-based polymers for ion-selective electrode (ISE) membranes was investigated by a spectrophotometric method to determine the apparent diffusion coefficient. By observing the degree of deprotonation of the chromoionophore or chromogenic ionophore, the extent of penetration of cations into the polymer films was determined. The transport of the cations into the optode films depended on the stoichiometry of complexation by the ionophores. The apparent diffusion coefficients, estimated from the deprotonation data were of the order of 10−12 to 10−11 cm2 s−1. These values indicate that the apparent ion mobility in the methacrylic-acrylic ISE membranes is approximately a thousand times lower than that in plasticised PVC ISE membranes. For some ionophores, the value of the apparent diffusion coefficient could be modulated according to the ionophore content in the membrane and the data obtained for a calixarene containing membrane were tested against a model for facilitated diffusion with chained carriers. The data did not fit a model where intramolecular diffusion was limiting, but were consistent with a first-order rate-limiting mechanism involving an intermediate 1:2 complex between ion and ionophore. In this instance, the lowest values for Dapp were thus not necessarily obtained for lowest ionophore loading and in the range examined, a trend of decreasing Dapp with increasing ionophore was noted.  相似文献   

2.
To date, poly(vinyl chloride) (PVC) is the most used polymer in the design of ion selective electrode (ISE) membranes. This paper is focused on the use of sulfonated poly(ether ether ketone) (SPEEK) as an alternative material to PVC for the design of ISEs. SPEEK of the desired degree of sulfonation is synthesized from poly(ether ether ketone) (PEEK). An NH4+-ISE has been chosen as a model electrode to study the efficiency of SPEEK as polymer matrix of the membrane. The material was evaluated in ionophore free ion exchanger membranes as well as in ion-selective electrodes membranes containing nonactine as ionophore. Analytical performance parameters of the prepared electrodes were evaluated. The electrodes show a slope between 50 and 60 mV dec−1 depending on both the calibration medium and the membrane composition. A linear range of response between 10−4 and 1.0 M and a lifetime of 1-2 months were obtained. The interferences of cations such us Ca2+, Na+, Li+ and K+ over the prepared ISEs are studied as well. Although the plasticizer in the SPEEK based membrane matrix is not necessary, its presence improves the sensibility. This makes SPEEK a good potential choice over alternative membrane matrices reported in the literature and a promising platform for the establishment of membrane components.  相似文献   

3.
Three new calixarene Tl+ ionophores have been utilized in Tl+ ion-selective electrodes (ISEs) yielding Nernstian response in the concentration range of 10−2–10−6 M TlNO3 with a non-optimized filling solution in a conventional liquid contact ISE configuration. The complex formation constants (log βIL) for two of the calixarene derivatives with thallium(I) (i.e. 6.44 and 5.85) were measured using the sandwich membrane technique, with the other ionophore immeasurable due to eventual precipitation of the ionophore during these long-term experiments. Furthermore, the unbiased selectivity coefficients for these ionophores displayed excellent selectivity against Zn2+, Ca2+, Ba2+, Cu2+, Cd2+ and Al3+ with moderate selectivity against Pb2+, Li+, Na+, H+, K+, NH4+ and Cs+, noting that silver was the only significant interferent with these calixarene-based ionophores. When optimizing the filling solution in a liquid contact ISE, it was possible to achieve a lower limit of detection of approximately 8 nM according to the IUPAC definition. Last, the new ionophores were also evaluated in four solid-contact (SC) designs leading to Nernstian response, with the best response noted with a SC electrode utilizing a gold substrate, a poly(3-octylthiophene) (POT) ion-to-electron transducer and a poly(methyl methacrylate)–poly(decyl methacrylate) (PMMA–PDMA) co-polymer membrane. This electrode exhibited a slope of 58.4 mV decade−1 and a lower detection limit of 30.2 nM. Due to the presence of an undesirable water layer and/or leaching of redox mediator from the graphite redox buffered SC, a coated wire electrode on gold and graphite redox buffered SC yielded grossly inferior detection limits against the polypyrrole/PVC SC and POT/PMMA–PDMA SC ISEs that did not display signs of a water layer or leaching of SC ingredients into the membrane.  相似文献   

4.
A sensitive optode consisting of highly lead-selective ionophore (Lead IV), proton-selective chromoionophore (ETH 5294) and lipophilic anionic sites (KTpClPB) in plasticized polyvinyl chloride (PVC) membrane was fabricated. The optode membranes were used for determination of Pb2+ by absorption spectrophotometry in batch and flow-through systems. The influence parameters such as pH, type of buffer solution, response time and concentration of regenerating solution were optimized. The membrane responded to Pb2+ by changing its color from blue to pinkish purple in Tris buffer containing different concentration of Pb2+ at pH 7.0. The optode provided the response range of 3.16 × 10−8 to 5.00 × 10−5 mol L−1 Pb2+ with the detection limit of 2.49 × 10−8 mol L−1 in the batch system within the response time of 30 min. The dynamic range of 1.26 × 10−8 to 3.16 × 10−5 mol L−1 Pb2+ with detection limit of 8.97 × 10−9 mol L−1 were obtained in the flow-through system within the response time of 15 min. Moreover, the proposed optode sensors showed good selectivity towards Pb2+ over Na+, K+, Mg2+, Cd2+, Hg2+ and Ag+. It was successfully applied to determine Pb2+ in real water samples and the results were compared with well-established inductively coupled plasma optical emission spectrometry (ICP-OES). No significant different value (tcritical = 4.30 > texp = 1.00-3.42, n = 3 at 95% of confidence level) was found.  相似文献   

5.
Jeong T  Lee HK  Jeong DC  Jeon S 《Talanta》2005,65(2):543-548
PVC membrane electrodes for lead ion based on N,N’-bis(salicylidene)-2,6-pyridinediamine as membrane carrier were prepared. Among their membranes, a membrane electrode (m-3) containing o-NPOE as a plasticizer and 50 mol% additive displays an excellent Nernstian response (29.4 mV/decade) and the limit of detection of −log a (M) = 6.04 to Pb2+ in Pb(NO3)2 solutions at room temperature. It has a rapid response time within 10 s over the entire concentration range. The proposed electrode revealed good selectivity and response for Pb2+ over a wide variety of other metal ions in a pH 5.0 buffer solutions, and good reproducibility of base line in subsequent measurements.  相似文献   

6.
An all-solid-state polymeric membrane Pb2+ ion-selective electrode (Pb2+-ISE) based on bimodal pore C60 (BP-C60) as solid contact has been developed. A BP-C60 film can be readily formed on the surface of a glassy carbon electrode by electrochemical deposition. Cyclic voltammetry and electrochemical impedance spectroscopy have been employed to characterize the BP-C60 film. The large double layer capacitance and fast charge-transfer capability make BP-C60 favorable to be used as solid contact for developing all-solid-state ISEs. The all-solid-state BP-C60-based Pb2+-ISE shows a Nernstian response in the range from 1.0 × 10−9 to 1.0 × 10−3 M with a detection limit of 5.0 × 10−10 M. The membrane electrode not only displays an excellent potential stability with the absence of a water layer between the ion-selective membrane and the underlying BP-C60 solid contact, but also is insensitive to interferences from O2, CO2 and light. The proposed solid-contact Pb2+-ISE has been applied to determine Pb2+ in real water samples and the results agree well with those obtained by anodic stripping voltammetry.  相似文献   

7.
A novel fluorescence chemical sensor for the highly sensitive and selective determination of Pb2+ ions in aqueous solutions is described. The preliminary potentiometric and spectrofluorimetric complexation studies in solution revealed that the lipophilic ligand 5,8-bis((5′-chloro-8′-hydroxy-7′-quinolinyl)methyl)-2,11-dithia-5,8-diaza-2,6-pyridinophane (L2) forms a highly stable and selective [PbL2]2+ and [Pb(L2)2]2+ complexes which results in a strong fluorescence quenching of the ligand. Thus, a novel fluorescence Pb2+ sensing system was prepared by incorporating L2 as a neutral lead-selective fluoroionophore in the plasticized PVC membrane containing tetrakis(p-chlorophenyl) borate as a liphophilic anionic additive. The response of the sensor is based on the strong selective fluorescence quenching of L2 by Pb2+ ions. At pH 5.5, the proposed sensor displays a calibration curve over a wide concentration range of 3.0 × 10−7 to 2.5 × 10−2 M with a relatively fast response time of less than 5 min. In addition to high stability, reversibility and reproducibility, the sensor shows a unique selectivity towards Pb2+ ion with respect to common coexisting cations. The proposed fluorescence optode was successfully applied to the determination of lead in plastic toys and tap water samples.  相似文献   

8.
A new surface based on poly(vinylferrocenium) (PVF+)-modified platinum electrode was developed for determination of Hg2+ ions in aqueous solutions. The polymer was electrodeposited on platinum electrode by constant potential electrolysis as PVF+ClO4. Cl ions were then attached to the polymer matrix by anion exchange and the modified electrode was dipped into Hg2+ solution. Hg2+ was preconcentrated at the polymer matrix by adsorption and also complexation reaction with Cl. Detection of Hg2+ was carried out by differential pulse anodic stripping voltammetry (DPASV) after reduction of Hg2+. Mercury ions as low as 5 × 10−10 M could be detected with the prepared electrode and the relative standard deviation was calculated as 6.35% at 1 × 10−6 M concentration (n = 6). Interferences of Ag+, Pb2+ and Fe3+ ions were also studied at two different concentration ratios with respect to Hg2+. The developed electrode was applied to the determination of Hg2+ in water samples.  相似文献   

9.
The performance of calix[2]furano[2]pyrrole and related compounds used as neutral carriers for silver selective polymeric membrane electrode was investigated. The silver ion-selective electrode based on calix[2]furano[2]pyrroles gave a good Nernstian response of 57.1 mV per decade for silver ion in the activity range 1×10−6 to 1×10−2 M. The present silver ion-selective electrode displayed very good selectivity for Ag+ ion against alkali and alkaline earth metal ions, NH4+, and H+. In particular, the present Ag+-selective electrode exhibited very low responses towards Hg2+ and Pb2+ ions. The potentiometric selectivity coefficients of the silver ion-selective electrode exhibited a strong dependence on the solution pH. In particular, the response of the electrode to the Hg2+ activity was greatly diminished at pH 2.5 compared to that at pH 5.0. Overall, the performance of the present silver ion-selective electrode based on the ionophore, calix[2]furano[2]pyrrole, is very comparable to that of the electrode prepared with the commercially available neutral carrier in terms of slope, linear range, and detection limits.  相似文献   

10.
Hassan SS  Attawiya AM 《Talanta》2006,70(4):883-889
A novel potentiometric uranyl membrane sensor with a divalent anionic response is developed, characterized and used for determination of uranyl ion. The sensor incorporates triethylenetetramine (TETA) as an ionophore in poly(vinyl chloride) matrix membrane (PVC) plasticized with o-nitrophenyloctyl ether (o-NPOE). In strong sulphate test solutions, UO22+ ion forms a highly stable [UO2(SO4)2]2− anion, extractable in TETA as {(2TETAH)2+ [UO2(SO4)2]2−} complex. Formation of the complex is confirmed and characterized by elemental analysis, mass spectrometry and infrared spectrometry. Sensor based on this system displays at pH 2.5-3.8 a linear response over the concentration range of 1.0 × 10−1-3.5 × 10−5 mol l−1 uranium with a near-Nernstian calibration slope of −26.5 ± 0.3 mV decade−1. The lower limit of detection is ∼5 μg ml−1, the lifetime is 12 weeks and negligible interferences are caused by most common cations. Validation of the assay method reveals excellent performance characteristics in terms of sensitivity, selectivity, fast response and potential stability. The sensor is used for the determination of 0.01-7.09 wt% uranium in naturally occurring and certified ore samples. The results show an average recovery of 97.6% and compare fairly well with data obtained using X-ray fluorescence technique.  相似文献   

11.
The present paper has focused on the potential application of the bifunctional polydopamine@Fe3O4 core–shell nanoparticles for development of a simple, stable and highly selective electrochemical method for metal ions monitoring in real samples. The electrochemical method is based on electrochemical preconcentration/reduction of metal ions onto a polydopamine@Fe3O4 modified magnetic glassy carbon electrode at −1.1 V (versus SCE) in 0.1 M pH 5.0 acetate solution containing Pb2+ and Cd2+ during 160 s, followed by subsequent anodic stripping. The proposed method has been demonstrated highly selective and sensitive detection of Pb2+ and Cd2+, with the calculated detection limits of 1.4 × 10−11 M and 9.2 × 10−11 M. Under the optimized conditions, the square wave anodic stripping voltammetry response of the modified electrode to Pb2+ (or Cd2+) shows a linear concentration range of 5.0–600 nM (or 20–590 nM) with a correlation coefficient of 0.997 (or 0.994). Further, the proposed method has been performed to successfully detect Pb2+ and Cd2+ in aqueous effluent.  相似文献   

12.
An ion-selective bulk optode (ISBO) for sensing Cu2+ and Pb2+ ions based on plasticized poly(vinyl chloride) containing 1,10-dibenzyl-1,10-diaza-18-crown-6 (DBzDA18C6) as ionophore and 1-(2-pyridylazo)-2-naphthol (PAN) as chromoionophore was prepared. The effects of DBzDA18C6/PAN and NaTPB/PAN mole ratios on the response behavior of the ISBO were investigated. The ISBO membrane shows enhanced selectivities for Cu2+ (at 530 nm) and Pb2+ (at 467 nm) over alkali, alkaline earth and other transition metal ions. The optical selectivity coefficients were measured using the separate solution method (SSM) in the two corresponding wavelengths at pH=5. The detection limit for Cu2+ and Pb2+ are 3.2×10−7 and 1.0×10−8 M, respectively.  相似文献   

13.
A PVC membrane electrode for copper ion based on 1,3-dithiane,2-(4-methoxy phenyl) as ionophore and o-nitrophenyl octyl ether as a plasticizer is demonstrated. The electrode exhibits a Nernstian slope of 29.5±1 mV per decade in a linear range of 3.0×10−6 to 5.0×10−2 M for Cu2+ ion. The detection limit of this electrode is 1.0×10−6 mol/l. This sensor has a very short response time of about 5 s and could be used in a pH range of 4.0-7.0. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully applied as an indicator electrode for the potentiometric titration of copper ion with EDTA and for the direct determination of copper in river water.  相似文献   

14.
A Sn2+ ion-selective electrode which was prepared with a polymeric membrane based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0]hex-2-ene (NDDBH) as a ionophore. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, the amount of additive and concentration of internal solution on the potential response of Sn2+ sensor were investigated. The electrode exhibited a Nernstian slope of 28.8 ± 1.1 mV/decade of Sn2+ over a concentration range of 1.0 × 10−5 to 1.0 × 10−1 M of Sn2+ in an acidic solution (pH 1). The limit of detection was 4.0 × 10−6 M. The results show that this electrode can be used in ethanol media until 20% (v/v) concentration without interference. It can be used for more than 6 weeks without any considerable divergence in the potentials. The proposed membrane electrode revealed very good selectivity for Sn(II) ions over a wide variety of other cations and could be used in acidic media. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The stability constant (log Ks) of the Sn(II)-ionophore complex was determined at 25 °C by potentiometric titration in mixed aqueous solution. It was used as indicator electrode in potentiometric determination of Sn(II) ion in real samples.  相似文献   

15.
A novel selective membrane electrode for determination of ultra-trace amount of lead was prepared. The PVC membrane containing N,N′-dimethylcyanodiaza-18-cown-6 (DMCDA18C6) directly coated on a graphite electrode, exhibits a Nernstian response for Pb2+ ions over a very wide concentration range (from 1.0×10−2 to 1.0×10−7 M) with a limit of detection of 7.0×10−8 M (∼14.5 ppb). It has a fast response time of ∼10 s and can be used for at least 2 months without any major deviation in potential. The electrode revealed very good selectivity with respect to all common alkali, alkaline earth, transition and heavy metal ions. The proposed sensor was used as an indicator electrode in potentiometric titration of lead ions and in determination of lead in edible oil, human hair and water samples. The proposed sensor was found to be superior to the best Pb2+-selective electrodes reported in terms of detection limit and selectivity coefficient.  相似文献   

16.
The feasibility of a newly synthesized Rh(III) complex, Rh[(trpy)(bpy)Cl](PF6)2, as a novel ionophore for the preparation of anion-selective polymeric membrane electrodes was tested. The ionophore exhibited anti-Hofmeister behavior with enhanced potentiometric selectivity toward thiocyanate ion compared to other anions. The influence of some experimental parameters such as membrane composition, nature and amount of plasticizer and additive and concentration of internal solution on the potential response of the SCN sensor were investigated. The electrode exhibits a Nernstian response for SCN over a wide concentration range (1.0 × 10−5 to 1.0 × 10−1 M) with a slope −58.7 ± 0.5 mV per decade and a detection limit of 4.0 × 10−6 M (0.23 ppm). It could be used in a pH range of 3.0-8.0 and has a fast response time of about 15 s. The proposed sensor was used for the determination of thiocyanate ions in real samples such as urine and saliva of smokers and nonsmokers and, as an indicator electrode, in potentiometric titrations of SCN ion.  相似文献   

17.
Novel 5-amino-1,3,4-thiadiazole-2-thiol unit based macrocyclic ionophore 5,11,17-trithia-1,3,7,9,13,15,19,20,21-nonaazatetracyclo[14.2.1.14,7.110,13]henicosa-4(20),10(21),16(19)-triene-6,12,18-trithione (M1), was synthesized and characterized. Preliminary studies on M1 have showed that it has more the affinity toward Cd2+ ion. Thus, the macrocyclic ionophore (M1) was used as electroactive material in the fabrication of PVC-membrane electrodes such as polymeric membrane electrode (PME), coated graphite electrode (CGE) and coated pyrolytic graphite electrode (CPGE) were prepared and its performance characteristic were compared with. The electroanalytical studies performed on PME, CGE and CPGE revealed that CPGE having membrane composition M1:PVC:1-CN:NaTPB in the ratio of 7:37:54:2 exhibits the best potentiometric characteristics in terms of detection limit of 7.58 × 10−9 mol L−1, Nernstian slope of 29.6 mV decade−1 of activity. The sensor was found to be independent of pH in the range 2.5–8.5. The sensor showed a fast response time of 10 s and could be used over a period of 4 months without any significant divergence in its potentiometric characteristics. The sensor has been employed for monitoring of the Cd2+ ion in real samples and also used as an indicator electrode in the potentiometric titration of Cd2+ ion with EDTA.  相似文献   

18.
19.
Zhang L  Li W  Shi M  Kong J 《Talanta》2006,70(2):432-436
A novel film modified electrode for the determination of trace lead was developed in this work. The modified electrode was prepared by the electropolymerization of N,N′-(o-phenylene)-bis-benzenesulfonamide (PBSA) as the ion capturing reagent to create the functional film. The modified electrode shows a high selectivity towards Pb2+ over interfering cations, e.g. Cu2+, Cd2+, Co2+, Ni2+, Zn2+, Cr2+, and the calibration curve was linear in the concentration range of 2.0 × 10−9 to 1.0 × 10−7 M with correlation coefficient of 0.999. For 20 min accumulation, detection limit of 1.0 × 10−9 M was obtained at the signal to noise ratio of 3. Analytical availability of the modified electrode was demonstrated by the application for samples from pond water.  相似文献   

20.
Polycrystalline silver sulphide/silver iodide ion selective electrodes (ISEs) with four different compositions, 9:1, 2:1, 1:1, 1:9 Ag2S-AgI mole ratios, have been fabricated in the laboratory and characterized by X-ray diffractometry (XRD), scanning electron microscopy (SEM), and electrochemical impedance spectroscopy (EIS). X-ray diffraction studies show the presence of Ag3SI, Ag2S and AgI crystalline phases in the electrode material. The electrode surfaces have been found to become smoother and lustrous with increasing percentage of silver sulphide in silver iodide. ISE 1:1, ISE 2:1 and ISE 9:1 all responded in Nernstian manner with slopes of about 60 mV/decade change in iodide ion concentration in the linear range of 1 × 10−1 to 1 × 10−6 M while ISE 1:9 showed sub-Nernstian behavior with slope of about 45 mV up to the concentration 1 × 10−5 M. Two capacitive loops, one corresponding to the charge transfer process at metal electrode and the back contact and a second loop corresponding to the charge transfer process at membrane-electrolyte interface have been observed at high and low frequency ranges, respectively. Mott-Schottky analysis shows that the materials are n-type semiconductors with donor defect concentrations in the range of 5.1 × 1014 to 2.4 × 1019/cm3.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏