首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
A simple electrochemical method was developed for the single and simultaneous determination of butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) in food samples using square-wave voltammetry (SWV). A carbon composite electrode modified (MCCE) with copper (II) phosphate immobilized in a polyester resin was proposed. The modified electrode allowed the detection of BHA and BHT at potentials lower than those observed at unmodified electrodes. A separation of about 430 mV between the peak oxidation potentials of BHA and BHT in binary mixtures was obtained. The calibration curves for the simultaneous determination of BHA and BHT demonstrated an excellent linear response in the range from 3.4 × 10−7 to 4.1 × 10−5 mol L−1 for both compounds. The detection limits for the simultaneous determination of BHA and BHT were 7.2 × 10−8 and 9.3 × 10−8 mol L−1, respectively. In addition, the stability and repeatability of the electrode were determined. The proposed method was successfully applied in the simultaneous determination of BHA and BHT in several food samples, and the results obtained were found to be similar to those obtained using the high performance liquid chromatography method with agreement at 95% confidence level.  相似文献   

2.
The development and performance evaluation of an analytical method dedicated to the comprehensive determination of the most relevant antioxidants and their metabolites in aqueous environmental samples is presented. This was achieved by a miniaturised solid-phase extraction (SPE) with 10 mg Oasis HLB cartridges, which allow to achieve a concentration factor of 200, reducing organic solvent wastes (1 mL of ethyl acetate suffices for complete elution) and SPE costs and eliminating the need for solvent evaporation that otherwise compromises the recoveries of butylated hydroxytoluene (BHT) and 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q). Analytes were then determined by gas chromatography–mass spectrometry (GC–MS) after derivatisation with N-methyl-N-(tert-butyldimethylsilyl)-trifluoroacetamide (MTBSTFA) in a single run. BHT-d7 and n-propyl-paraben-d4 (PrP-d4) were used as surrogate internal standards. These surrogates allowed obtaining relative recoveries in the 80–110% range for all analytes even with complex wastewater samples and LODs at the 2–44 ng L−1 level taking into account blank issues often associated to antioxidants analysis. The method was applied to sewage and river waters, showing that the seven analytes could be detected in raw wastewater. BHT and BHT-Q were the most concentrated species in that type of sample (in the 275–871 ng L−1 range). On the other hand two metabolites of BHT, 3,5-di-tert-butyl-4-hydroxybenzaldehyde (BHT-CHO) and 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) appeared to be the most ubiquitous species, being found in all samples in the 10–150 ng L−1 concentration range.  相似文献   

3.
Electrochemical behavior of three antioxidants: butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT) and butylated hydroquinone (TBHQ), was investigated at a glassy carbon electrode modified with gold nanoparticles (AuNPs/GCE). This electrode was characterized by scanning electron microscopy (SEM). The experimental results indicated that the modified electrode was strongly electroactive during the redox reactions of BHA, BHT and TBHQ, and this was confirmed by the observed increased redox peak currents and shifted potentials; in addition, the oxidation products of BHA and TBHQ were found to be the same. The experimental conditions were optimized and the oxidation peaks of BHA and BHT were clearly separated. Based on this, an electrochemical method was researched and developed for the simultaneous determination of BHA, BHT and TBHQ in mixtures with the use of first derivative voltammetry; the linear concentration ranges were 0.10–1.50 μg mL−1, 0.20–2.20 μg mL−1 and 0.20–2.80 μg mL−1, and detection limits were 0.039, 0.080 and 0.079 μg mL−1, for BHA, BHT and TBHQ, respectively. The proposed method was successfully applied for the analysis of the three analytes in edible oil samples.  相似文献   

4.
Tormin TF  Gimenes DT  Richter EM  Munoz RA 《Talanta》2011,85(3):1274-1278
We report here, for the first time, application of batch injection analysis (BIA) with amperometric detection for determination of the phenolic antioxidant butylated hydroxyanisole (BHA) in biodiesel. A sample plug was directly injected onto a boron-doped diamond electrode immersed in 50% v/v hydroethanolic solution with 0.1 mol L−1 HClO4 using an electronic micropipette. Importantly, the only preparation step required for biodiesel analysis is dilution in the same hydroethanolic electrolyte solution. Our proposed method has several advantages for routine biodiesel analysis, including: a low relative standard deviation between injections (0.29%, n = 20), high analytical frequency (120 h−1), adequate recovery values (93-101%) for spiked samples, satisfactory accuracy (based on comparative determinations by high-performance liquid-chromatography), and a low detection limit (100 ng of BHA per g of biodiesel). Finally, our method can be adapted for the determination of other antioxidants in biodiesel samples.  相似文献   

5.
Fakhari AR  Khorrami AR  Naeimi H 《Talanta》2005,66(4):813-817
A novel sensitive chromogenic reagent, N,N′-bis(3-methylsalicylidene)-ortho-phenylene diamine (MSOPD), has been synthesized and used in the spectrophotometric determination of nickel. At pH 8, MSOPD can react with nickel ion at room temperature to form a 1:1 complex. The apparent molar absorptivity is 9.5 × 104 l mol−1 cm−1 at 430 nm. Beer's low is obeyed over the range 0-1.0 × 10−5 M of nickel with a detection limit of 1.36 × 10−8 M. The relative standard deviation for measurement of 3.41 × 10−6 M nickel is 1.3% (n = 10). The method has successfully been applied to determination of trace amounts of nickel in some natural food samples.  相似文献   

6.
In this study a method for the determination of low concentrations of silver in waters using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry (FAAS) was developed. Moringa oleifera seeds were used as a biosorbent material. Chemical and flow variables of the on-line preconcentration system such as sample pH and flow rate, preconcentration time, eluent concentration and sorbent mass were studied. The optimum preconcentration conditions were obtained using sample pH in the range of 6.0-8.0, preconcentration time of 4 min at a flow rate of 3.5 mL min− 1, 0.5 mol L− 1 HNO3 eluent at a flow rate of 4.5 mL min− 1 and 35 mg of sorbent mass. With the optimized conditions, the preconcentration factor, precision, detection limit and sample throughput were estimated as 35 (for preconcentration of 14 mL sample), 3.8% (5.0 μg L− 1, n = 7), 0.22 μg L− 1 and 12 samples per hour, respectively. The developed method was successfully applied to mineral water and tap water, and accuracy was assessed through analysis of a certified reference material for water (APS-1071 NIST) and recovery tests, with recovery ranging from 94 to 101%.  相似文献   

7.
The supramolecular interaction of a homologous series of cucurbit[n]uril (CB[n], n = 5, 6, 7, 8) hosts and coptisine (COP) was studied by spectrofluorimetry. All of the CB[n]s were found to react with COP to form 1:1 host-guest stable complexes and the fluorescence intensity of the complexes was greatly enhanced. The apparent association constants of the complexes were 1.44 × 104, 1.28 × 104, 1.86 × 104 and 1.26 × 104 L mol−1 for CB[5], CB[6], CB[7] and CB[8], respectively. In addition, CB[5] and CB[7] exhibited a higher fluorescence signal than CB[6] and CB[8]. The fluorescence intensity of the complex with CB[7] was enhanced 70-fold compared to that of the studied drug itself. Based on the significant enhancement of fluorescence intensity of supramolecular complex, a simple, rapid, highly sensitive, and selective spectrofluorimetric method was developed for the determination of COP in aqueous solution in the presence of CB[7]. At the optimum reaction conditions, a linear relationship was obtained in the range from 0.05 to 1700 ng mL−1 with a detection limit of 0.012 ng mL−1. The proposed method was successfully applied for the determination of the drug in urine and serum samples.  相似文献   

8.
In this work a simple, fast, sensitive and selective flow-based procedure for the chemiluminometric determination of carvedilol, a recent non-cardioselective β-blocker with noteworthy antioxidant activity, is proposed. The developed methodology takes advantage of the antioxidant capacity of carvedilol to inhibit the chemiluminescence response resulting from the oxidation of luminol by hypochlorite, by acting as a hypochlorite scavenger. The analytical process was implemented in a multi-pumping flow system that employs multiple solenoid actuated micro-pumps as the only active components. These acted as solution insertion, propelling and commuting units assuring an easily controlled, low cost, compact and reliable analytical system.A linear working range for carvedilol concentrations ranging from 1.2 × 10−7 to 3.0 × 10−6 mol l−1 (r > 0.999, n = 6), was obtained, with a detection limit of 8.7 × 10−9 mol l−1. The system handles about 65 samples per hour yielding precise results (R.S.D. < 1.3%, n = 10). Recoveries within 95 and 104% were obtained.  相似文献   

9.
A novel flow-injection spectrophotometry has been developed for the determination of molybdenum(VI) at nanograms per milliliter levels. The method is based on the catalytic effect of molybdenum(VI) on the bromate oxidative coupling of p-hydrazinobenzenesulfonic acid with N-(1-naphthyl)ethylenediamine to form an azo dye (λmax = 530 nm). Chromotropic acid (4,5-dihydroxy-2,7-naphthalenedisulfonic acid) acted as an effective activator for the molybdenum(VI)-catalyzed reaction and increased the sensitivity of the method. The reaction was monitored by measuring the change in absorbance of the dye produced. The proposed method allowed the determination of molybdenum(VI) in the range 1.0-20 ng mL−1 with sample throughput of 15 h−1. The limit of detection was 0.5 ng mL−1 and a relative standard deviation for 10 ng mL−1 molybdenum(VI) (n = 10) was 2.5%. The interfering ions were eliminated by using the combination of a masking agent and on-line minicolumn packed with cation exchanger. The present method was successfully applied to the determination of molybdenum(VI) in plant foodstuffs.  相似文献   

10.
Two highly sensitive chemiluminescence (CL) systems are described. The method is based on the CL generated during the oxidation of luminol by N-bromosuccinimide (NBS) and N-chlorosuccinimide (NCS) in alkaline medium. The emission intensity is reduced by the presence of some surfactants at concentrations lower than critical micelle concentration (cmc).A new, simple, rapid and selective flow injection CL method for the determination of cationic surfactants such as dodecyltrimethylammonium bromide (DTAB), cetyltrimethylammonium bromide (CTAB) and cetylpyridinium chloride (CPC) is proposed. Their determinations are based on the reducing effect on the emission intensity of NBS-luminol and NCS-luminol chemiluminescent reactions. The effect of analytical and flow injection analysis (FIA) variables on these CL systems and on the determination of the cationic surfactants are discussed. The optimum parameters for the determination of cationic surfactants were studied and were found to be the following: luminol, 1×10−6 M; NBS and NCS both, 5×10−2 M; NaOH, 5×10−2 M and flow rate, 3.5 ml min−1.  相似文献   

11.
The present work describes a sequential injection analysis (SIA) system adapted to direct analysis of oil samples. In this way, the flow system was designed by incorporation, in the SIA system, of an injection valve that was responsible for the sample insertion. With the developed sampling strategy the sample pre-treatment outside the flow system is avoided and also the problems associated with viscous samples in flow systems.The developed SIA system was applied to the determination of iron (Fe(III)) in edible oil samples and was based on the formation of a red complex (λ = 510 nm) between Fe(III) and thiocyanate in organic medium. A mixture of methanol:chloroform (85:15) was used as carrier solution and possible refractive index associated with the spectrophotometric detection was avoided by introduction of a mixing chamber in the flow system. The presented methodology produced 4.2 ml of effluent and consumed 150 μl of sample and 0.95 mg of thiocyanate per determination.Linear calibration plots were obtained for Fe(III) concentrations up to 25 mg l−1 and the detection limit of the determination was 0.31 mg l−1. The developed methodology exhibited a good precision, with an R.S.D. < 3.5% (n = 15) and a determination frequency of 20 determinations h−1. The results of the analysis were evaluated by recovery studies (96.5-104.5%) and by the analysis of two AOCS reference samples.  相似文献   

12.
An on-line flow injection spectrofluorimetric method for the direct determination of aluminium in water samples is described. The method is based on the reaction of aluminium with N-o-vanillidine-2-amino-p-cresol (OVAC) in acidic medium at pH 4.0 to form a water-soluble complex. The excitation and emission wavelengths were 423.0 and 553.0 nm, respectively, at which the OVAC-Al complex gave the maximum fluorescence intensity at pH 4.0 in a 50% methanol-50% water medium at 50 °C. An interference from fluoride ions was minimised by the addition of Be2+. Other ions were found not to interfere at the concentrations likely to be found in natural waters. The proposed methods were validated in terms of linearity, repeatability, detection limit, accuracy and selectivity. Under these conditions, the calibration was linear up to 1000 μg L−1 (r = 0.999). The limit of detection (3σ) for the determination of Al(III) was 0.057 μg L−1 and the precision for multiple determinations of 3 ng mL−1 Al(III) prepared in ultra-pure water was found to be 0.62% (n = 10).The Schiff base ligand could be used to determine ultra-trace aluminium from natural waters. Analysis of environmental certified reference materials showed good agreement with the certified values. The procedure was found to be equally applicable to both freshwater and saline solutions, including seawater.  相似文献   

13.
A new capillary electrophoresis (CE) method for the determination of quinolizidine alkaloids in Sophora medicinal plants was developed. A total of seven alkaloid components (cytisine, sophocarpine, matrine, lehmannine, sophoranol, oxymatrine and oxysophocarpine) were separated within 15 min. The running buffer was a 50 mM phosphate buffer containing 1%HP-β-CD and 3.3% isopropanol. The linear calibration ranges were 5.50-88.0 μg ml−1 for cytisine and lehmannine, 5.00-88.0 μg ml−1 for sophocarpine and sophoranol, 5.60-89.6 μg ml−1 for matrine and oxysophocarpine, and 24.0-384 μg ml−1 for oxymatrine. The recoveries of the seven alkaloids were 96.0-102.9% with relative standard deviations from 1.50 to 3.00% (n = 5). The method was successfully applied to different Sophora medicinal plants including Sophora flavescens, Sophora tonkinensis and Sophora alopecuroides.  相似文献   

14.
Nie F  Wang N  Zheng J  Zhang J 《Talanta》2011,84(4):1063-1067
A strong post chemiluminescence (PCL) phenomenon was observed when ammonium was injected into the reaction mixture after the finish of CL reaction of N-bromosuccinimide (NBS) and dichlorofluorescein. Based on this, a sensitive flow injection PCL method was established for the determination of ammonium. The possible CL mechanism of the reaction was proposed based on a series of experiments. The PCL intensity responded linearly to the concentration of ammonium in the range 3.0 × 10−11-1.0 × 10−7 g mL−1 with a detection limit of 1 × 10−11 g mL−1. The relative standard deviation (R.S.D.) was 1.4% for 1.0 × 10−9 g mL−1 ammonium (n = 11). This method had been applied to the determination of ammonium in samples of mineral water, tap water and river water.  相似文献   

15.
A highly sensitive and relatively interference-free spectrophotometric method for determination of calcium is described. The method is based on the reaction between calcium ions and carboxyazo-p-CH3 in aqueous citrate medium of pH 7, to form a blue complex with maximum absorption at 716 nm. The calibration is linear up to 0.12 μg ml−1 calcium with a repeatability (R.S.D.) of 1.0% at a concentration of 0.04 μg ml−1 (n=5). The molar absorptivity of the complex and Sandell’s sensitivity are 3.5×105 l mol−1 cm−1 and 0.11 ng cm−2, its 10σ limit of quantification and the 3σ limit of detection were found to be 0.3 ng ml−1 and 0.09 ng ml−1 respectively. The influence of reaction variables and the effect of interfering ions are studied; no interference was observed in clinical samples. The proposed method has been applied directly to the determination of calcium in clinical samples without the need for pre-concentration, masking metal ions and digesting samples.  相似文献   

16.
Ohno S  Teshima N  Sakai T  Grudpan K  Polasek M 《Talanta》2006,68(3):527-534
A sequential injection (SI) method in a lab-on-valve (LOV) format for simultaneous spectrophotometric determination of copper and iron has been devised. The detection chemistry is based on the complex formation of 2-(5-bromo-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino]aniline (5-Br-PSAA) with copper(II) and/or iron(II) at pH 4.6. Copper(II) reacts with 5-Br-PSAA to form the complex which has an absorption maximum at 580 nm but iron(III) does not react. In the presence of a reducing agent only iron(II)-5-Br-PSAA complex is formed and detected at 558 nm. Under the optimum experimental conditions, the determinable ranges are 0.1-2 mg l−1 for copper and 0.1-5 mg l−1 for iron, respectively, with a sampling rate of 18 h−1. The limits of detection are 50 μg l−1 for copper and 25 μg l−1 for iron. The relative standard deviations (n = 15) are 2% for 0.5 mg l−1 copper and 1.8% for 0.5 mg l−1 iron when determined in standard solutions. The recoveries range between 96 and 105% when determining 0.25-2 mg l−1 of copper and 0.2-5 mg l−1 of iron in artificial mixtures at copper/iron ratios of 1:10 to 5:1. The proposed SI-LOV method is successfully applied to the simultaneous determination of copper and iron in multi-element standard solution and in industrial wastewater samples.  相似文献   

17.
A first order derivative spectrophotometric method has been developed for the simultaneous determination of bismuth and zinc by dithizone without time-consuming extraction step. The reactions of bismuth and zinc with dithizone in a three component solution prepared in water, acetone and n-propanol mixture have been investigated. These cations react with dithizone in this mixture at pH 5.0, forming coloured complex that is stable for at least 2 h. The linear range in D evaluation was between 3.0 × 10−6 and 1.8 × 10−5 mol l−1 for Zn and 2.4 × 10−6 and 1.2 × 10−5 mol l−1 for Bi. The limits of detection for the analytical procedure were found 0.05 mg l−1 for both cations. The relative standard deviations for the determination of 0.5 mg l−1 bismuth and 0.5 mg l−1 zinc were 1.2 and 1.1%, respectively, for five determinations. The procedure is simple, rapid and reliable. This method was applied to the determination of bismuth and zinc in the pharmaceutical materials successfully. Good agreement was achieved between the results obtained by the proposed and comparative methods.  相似文献   

18.
A highly sensitive flow analysis system has been developed for the trace determination of reactive phosphate in natural waters, which uses a polymer inclusion membrane (PIM) with Aliquat 336 as the carrier for on-line analyte separation and preconcentration. The system operates under flow injection (FI) and continuous flow (CF) conditions. Under optimal FI conditions the system is characterised by a linear concentration range between 0.5 and 1000 μg L−1 P, a sampling rate of 10 h−1, a limit of detection of 0.5 μg L−1 P and RSDs of 3.2% (n = 10, 100 μg L−1) and 7.7% (n = 10, 10 μg L−1). Under CF conditions with 10 min stop-flow time and sample solution flow rate of 1.32 mL min−1 the flow system offers a limit of detection of 0.04 μg L−1 P, a sampling rate of 5 h−1 and an RSD of 3.4% (n = 5, 2.0 μg L−1). Interference studies revealed that anions commonly found in natural waters did not interfere when in excess of at least one order of magnitude. The flow system, operating under CF conditions, was successfully applied to the analysis of natural water samples containing concentrations of phosphate in the low μg L−1 P range, using the multipoint standard addition method.  相似文献   

19.
Wang Y  Tang J  Luo X  Hu X  Yang C  Xu Q 《Talanta》2011,85(5):2522-2527
In this work, a kojic acid electrochemical sensor, based on a non-covalent molecularly imprinted polymer (MIP) modified electrode, had been fabricated in the lab-on-valve system. The sensitive layer was synthesized by cyclic voltammetry using o-phenylenediamine as the functional monomer and kojic acid as the template. The template molecules were then removed from the modified electrode surface by washing with NaOH solution. Differential pulse voltammetry method using ferricyanide as probe was applied as the analytical technique, after extraction of kojic acid on the electrode. Chemical and flow parameters associated with the extraction process were investigated. The response recorded with the imprinted sensor exhibited a response in a range of 0.01-0.2 μmol L−1 with a detection limit of 3 nmol L−1. The interference studies showed that the MIP modified electrode had excellent selectivity. Furthermore, the proposed MIP electrode exhibited good sensitivity and low sample/reagent consumption, and the sensor could be applied to the determination kojic acid in cosmetics samples.  相似文献   

20.
The paper presents a new HPLC method, with UV and MSn detection, for the determination of seven pesticides, including the sulfonylurea herbicides amidosulfuron, azimsulfuron, nicosulfuron, rimsulfuron, thifensulfuron methyl, tribenuron methyl, and the fungicide azoxystrobin characterised by a methoxyacrilate structure. The methodology consists of a preconcentration/SPE (solid phase extraction) step and HPLC-UV (240 nm detection wavelength)-MSn analysis. Under the optimised conditions and after a 1000/1 preconcentration factor, the limits of detection were lower than 14.5 ng L−1 for UV detection and lower than 8.1 ng L−1 for MS detection. The limits of quantification were lower than 48.3 ng L−1 in UV detection and than 26.9 ng L−1 in MSn detection. The analysis of two samples, spiked with a mixture of the pesticides at threshold level concentrations, gave more than 60% recovery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号