首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A.S. Alves Ferreira 《Talanta》2007,72(3):1223-1229
This paper deals on the determination of Strychnine, a potent and dangerous pesticide and the analytical procedure is based on the photo-induced chemiluminescence of the pesticide by means of the Multicommutation continuous-flow methodology. Small segments of the pesticide solution were sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. The required time of UV irradiation was obtained by stopped-flow during 150 s; then, the resulting solution formed alternated segments with the oxidizing solution containing 5 × 10−3 mol l−1 Ce(IV) in 0.6 mol l−1 nitric acid. The calibration range, from 2 μg l−1 to 50 mg l−1, resulted in a linear behaviour over the range 25 μg l−1 to 20 mg l−1 and fitting the equation: I = 4706x + 624 with a correlation coefficient of 0.9955. The limit of detection was 2 μg l−1 and the sample throughput 15 h−1. After testing the influence of a large series of potential interferents, the method was applied to different kinds of samples.  相似文献   

2.
A new method is proposed for the chemiluminescent determination of the pesticide 3-indolyl acetic acid by means of an flow injection analysis system. The chemiluminescence emission is obtained by oxidation of the analyte with Ce (IV) in nitric acid and presence of β-cyclodextrine.The continuous-flow method allows the determination of 159 samples h−1 of 3-indolyl acetic acid in an interval of concentrations over the range 0.5-15.0 mg l−1. The limit of detection was 0.1 μg l−1 and the R.S.D. (n, 17) at 2.0 mg l−1 of the pesticide level was 2.7%. The method was applied to water samples.  相似文献   

3.
The present paper is dealing with an analytical strategy based on coupling photodegradation, chemiluminescence and multicommutation continuous-flow methodology for the determination of the pesticide Propanil, a common herbicide. The pesticide solution is inserted as small segments sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. Both flow-rates (sample and medium) are adjusted to required time for photodegradation, 2.0 min; and then, the resulting solution is also sequentially inserted as segments alternated with segments of the oxidizing solutions system, 1.00 × 10−4 mol l−1 potassium permanganate in 2.00 mol l−1 sulphuric acid medium. The calibration range, from 10 μg l−1 to 25 mg l−1, resulted in a linear behaviour over the range 10 μg l−1-5 mg l−1 and fitting the linear equation: I = 780.30C + 95.28; correlation coefficient 0.9999. The limit of detection was 8 μg l−1 and the sample throughput 20 h−1. After testing the influence of a large series of potential interferents the method is applied to water samples obtained from different places and to one formulation. The method is valid for the determination of other pesticides from the same chemical family, namely: alachlor, flumetsulam, furalaxyl and ofurace. Calibration graphs, limits of detection, repeatability and determination in water samples are obtained for each reported pesticide.  相似文献   

4.
The cyclic voltammetric behavior of five common pesticides such as dicofol (DCF), cypermethrin (CYP), monocrotophos (MCP), chlorpyrifos (CPF) and phosalone (PAS) was investigated at a poly 3,4-ethylenedioxythiophene modified glassy carbon electrode (PEDOT/GCE). A method was developed for the detection and determination of these pesticides in trace level flowing stream, based on their redox behavior. The square wave stripping voltammetric principle was used to analyze the selected pesticides on PEDOT/GCE. Varying the accumulation potential and accumulation time, the best accumulation conditions were found out. Effects of initial scan potential, square wave pulse amplitude, step potential and frequency were examined for the optimization of stripping conditions. The peak current responses of analyte under optimum conditions were correlated over flow rate by using wall-jet PEDOT/GCE assembly. The calibration plots were linear over the pesticide's concentration range 0.10-72.60 μg l−1 for DCF, 0.41-198.24 μg l−1 for CYP, 0.22-220.95 μg l−1 for MCP, 0.35-259.69 μg l−1 for CPF and 1.07-141.46 μg l−1 for PAS. The limit of detection was obtained between <0.09 and <1.0 μg l−1 for five pesticides. It is low enough for trace pesticide determination in real samples. This method is applied for the determination of the five pesticides in soil samples. The recovery values obtained in spiked soil samples are 95.4 ± 5.4% for DCF, 93.7 ± 4.2% for CYP, 85.3 ± 8.4% for MCP, 94.6 ± 6.6% for CPF and 93.5 ± 4.9% for PAS.  相似文献   

5.
《Analytica chimica acta》2002,471(2):173-186
An automated and versatile sequential injection spectrofluorimetric procedure for the simultaneous determination of multicomponent mixtures in micellar medium without prior separation processes is reported. The methodology is based upon the segmentation of a sample slug between two different buffer zones in order to attain both an improvement of sensitivity and residual minimization for the whole species. Resolution of overlapping fluorescence profiles is achieved using a variable angle scanning technique coupled to multivariate least-squares regression (MLR) algorithms at both sample edges.The potentialities of the described methodology are illustrated with the spectrofluorimetric determination of four widespread pesticides with different acid-base properties; viz. carbaryl (CBL) (1-naphthyl-N-methylcarbamate), fuberidazole (FBZ) (2-(2′-furyl)benzimidazole), thiabendazole (TBZ) (2-(4′-thiazolyl)benzimidazole) and warfarin (W) (3-α-acetonylbenzyl)-4-hydroxycoumarin). Detection limits at the 3σ level were 3.9, 0.02, 0.03 and 10 μg l−1 for CBL, FBZ, TBZ and W, respectively at the maximum sensitivity pH. Dynamic ranges of 13-720 μg l−1 CBL, 0.10-14 μg l−1 FBZ, 0.19-60 μg l−1 TBZ and 0.05-5 mg l−1 W were achieved. Relative standard deviations (n=10) were 0.2% for 100 μg l−1 CBL and 2.4 μg l−1 FBZ, 0.7% for 8 μg l−1 TBZ and 1.0% for 1 mg l−1 W. The proposed automated methodology, which handles 17 samples/h, was validated and applied to spiked real water samples with very satisfactory results.  相似文献   

6.
The pyrethroid lambda-cyhalothrin is a common insecticide which is widespread in the environment. A study of the electrochemical reduction of the pesticide on a hanging mercury drop electrode (HMDE) was performed as basis for the development of a sensitive analytical method for determination of lambda-cyhalothrin in natural samples. Two electrochemical techniques—cyclic voltammetry (CV) and differential pulse voltammetry (DPV)—were applied. The study was performed in the pH range 2-13 using Britton-Robinson (B-R) buffer to control the pH of the measuring solutions and tetrabutylammonium chloride (TBAC) salt as supporting electrolyte. In DPV, a single reduction peak was observed at both pH<4.0 and pH>10.5 while two cathodic peaks were produced in the pH range 4.0-10.5. The results showed that the reduction of lambda-cyhalothrin in the measuring solution is irreversible. The limiting current was found to be diffusion-controlled and free of adsorption of the electroactive species to HMDE over the whole pH range tested. For the analytical DPV method running at pH 2 the relationship between peak current and lambda-cyhalothrin concentration was linear up to 500 μg l−1 (1.1×10−6 mol l−1) with a detection limit of 2.5 μg l−1. The repeatability in terms of relative standard deviation (n=10) was in the order of 3.5% at concentration levels of 5 and 10 μg l−1. A DPV method for determining lambda-cyhalothrin in the agrochemical formulation Karate, spiked soil and well water was developed. The recovery was about 94% in well water and 92% in soil samples at concentration range of 0.05-0.5 μg l−1 and 0.05-0.5 μg g−1, respectively.  相似文献   

7.
Dos Santos LB  Abate G  Masini JC 《Talanta》2004,62(4):667-674
This paper presents the optimization of instrumental and solution parameters for determination of atrazine in river waters and formulation by square wave voltammetry (SWV) using a hanging mercury drop electrode. The best sensitivity (35.2±0.4 μA ml μg−1) was achieved using a frequency of 400 Hz and a medium composed of 40 mmol l−1 Britton-Robinson (BR) buffer at pH 1.9. The detection limit was 2 μg l−1 with a linear dynamic range between 10 and 250 μg l−1. Application of the method to real samples of river waters fortified with 10 μg l−1 of atrazine resulted recoveries between 92 and 116%. Additionally, good agreement was observed between results obtained by the proposed method and by HPLC for river water samples spiked with 25 μg l−1 of atrazine. The determination was not affected by the presence of humic acid at concentration of 5 mg l−1, indicating that interactions of the herbicide with this class of compounds are fully labile. The stability of the voltammetric signal for samples spiked with 250 μg l−1 atrazine was evaluated over a period of 14 days in four samples. For two samples, no systematic variation was observed, while for the other two, a decrease of peak current between 3 and 15% occurred, suggesting that the stability is dependent on the sample nature. HPLC analyses suggest formation of deethylatrazine during the second week of storage in the samples for which the SWV peak current had the more intense decrease.  相似文献   

8.
9.
A flow-batch system was developed for the determination of Fe(III) in estuarine waters with high variability in salinity. The method is based on the catalytic effect of iron(III) on the oxidation rate of N,N-dimethyl-p-phenylenediammonium dichloride (DmPD) by hydrogen peroxide and the formed product is spectrophotometrically monitored at 554 nm. A controlled addition of sodium chloride to every assayed sample is accomplished for in-line individual salinity matching.The proposed system processes about 30 samples h−1 and yields reproducible results. Relative standard deviations were estimated as <1.5% after 10 injections of typical samples (10.0-50.0 μg l−1 Fe; ca. 0.5 mol l−1 Cl). Synthetic samples (15.0 μg l−1 Fe; 0.25-1.0 mol l−1 NaCl) were efficiently processed, and no significant differences in results were found at a probability level of 99.7%. The method works for the full range of salinities. Only 120 μg DmPD are consumed per determination. The analytical curve is linear up to about 60 μg l−1 Fe (r>0.999; n=5) and the detection limit is 5 μg l−1 Fe. Results are in agreement with graphite furnace atomic absorption spectrometry.  相似文献   

10.
In this study, a simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME) combined gas chromatography-electron capture detection (GC-ECD), for the determination of chlorobenzenes (CBs) in water samples, has been described. This method involves the use of an appropriate mixture of extraction solvent (9.5 μl chlorobenzene) and disperser solvent (0.50 ml acetone) for the formation of cloudy solution in 5.00 ml aqueous sample containing analytes. After extraction, phase separation was performed by centrifugation and the enriched analytes in sedimented phase were determined by gas chromatography-electron capture detection (GC-ECD). Our simple conditions were conducted at room temperature with no stiring and no salt addition in order to minimize sample preparation steps. Parameters such as the kind and volume of extraction solvent, the kind and volume of disperser solvent, extraction time and salt effect, were studied and optimized. The method exhibited enrichment factors and recoveries ranging from 711 to 813 and 71.1 to 81.3%, respectively, within very short extraction time. The linearity of the method ranged from 0.05 to 100 μg l−1 for dichlorobenzene isomers (DCB), 0.002-20 μg l−1 for trichlorobenzene (TCB) and tetrachlorobenzene (TeCB) isomers and from 0.001 to 4 μg l−1 for pentachlorobenzene (PeCB) and hexachlorobenzene (HCB). The limit of detection was in the low μg l−1 level, ranging between 0.0005 and 0.05 μg l−1. The relative standard deviations (R.S.D.s) for the concentration of DCB isomers, 5.00 μg l−1, TCB and TeCB isomers, 0.500 μg l−1, PeCB and HCB 0.100 μg l−1 in water by using the internal standard were in the range of 0.52-2.8% (n = 5) and without the internal standard were in the range of 4.6-6.0% (n = 5). The relative recoveries of spiked CBs at different levels of chlorobenzene isomers in tap, well and river water samples were 109-121%, 105-113% and 87-120%, respectively. It is concluded that this method can be successfully applied for the determination of CBs in tap, river and well water samples.  相似文献   

11.
A simple end-column electrochemical detector was designed and attached to an available commercial capillary electrophoresis instrument with UV detection to detect different kind of herbicides and to determinate methyl-4-aminophenyl-sulfonylcarbamate (asulam) in water samples. The designed cell is very easy to assemble and disassemble in a short period of time; the working electrode positioning is also quickly achieved without micropositioners. The alignment between working electrode and capillary outlet was very reproducible for the all checked electrodes; the R.S.D. obtained was lower than 6.0% for 100 μm gap distance. In this mode, the non-electroactive and electroactive compounds could be detected by UV and electrochemical detection, respectively at the same time. The electrochemical determination of asulam using micellar electrokinetic capillary chromatography (MEKC) is the first time that is reported. In both detection systems, a linear range was obtained for asulam concentrations lower than 25.0 mg l−1, in boric acid 0.020 mol l−1 at pH 8.20 and containing 0.025 mol l−1 of sodium dodecyl sulfate, to obtain selectivity additional separation by the micellar distribution process. Under these conditions, an experimental detection limit of 0.4 mg l−1 was achieved. A new experimental scheme is also described for asulam determination in tap waters with a previous preconcentration step. Using both, UV and electrochemical detection, with a previous extraction procedure, the detection limits of asulam in tap water samples were of 1.0 and 0.8 μg l−1, respectively.  相似文献   

12.
Ochratoxin A (OTA) is a mycotoxin (potentially carcinogenic secondary metabolite derived from fungal contamination), produced by some Aspergillus and Penicillium strains. Although present and legislated in different food sources in the human diet, the regulation for wine intake is still under discussion. The Office International de la Vigne et du Vin (OIV) recommended maximum levels in wine of 2 μg l−1. Some reports refer to OTA contamination in wines up to 15 μg l−1 and a special incidence in red wines from the southern regions of Europe and the north of Africa, but the majority of the data available are below 1 μg l−1. When working at such low concentrations, the problem of the uncertainty of the results becomes decisive towards the implementation of legal limits. In order to assess the global uncertainty associated with OTA determination in wines and widen the data set and knowledge of the situation in Portugal, 340 wines were analysed (189 Port Wine, 85 Vinho Verde and 66 wines from other regions in the country) by a high performance liquid chromatography (HPLC)-fluorescence detection (FD) method using immunoaffinity columns for clean up. OTA was detected in 69 wines by the method used, but in concentrations below 0.5 μg l−1, except for two which showed levels up to a maximum of 2.1 μg l−1. However, the global uncertainty for OTA is close to 37% for concentrations above 0.5 μg l−1, and therefore, such value can be below or exceed the OIV limit. In the vicinity of the limit of detection, 0.084 μg l−1, the global uncertainty rises exponentially to a maximum of about 70%. This can be an obstacle when discussing safety intake limits. Ethanol and glucose content did not interfere in the clean up of OTA by immunoaffinity columns.  相似文献   

13.
In this paper, the conversion of azoxystrobin in a strongly fluorescent degradation product by UV irradiation with quantitative purposes and its fluorimetric determination are reported for the first time. A multicommuted flow injection-solid phase spectroscopy (FI-SPS) system combined with photochemically-induced fluorescence (PIF) is developed for the determination of azoxystrobin in grapes, must and wine. Grape samples were homogenized and extracted with methanol and further cleaned-up by solid-phase extraction on C18 silica gel. Wine samples were solid-phase extracted on C18 sorbent using dichloromethane as eluent. Recoveries of azoxystrobin from spiked grapes (0.5-2.0 mg Kg−1), must (0.5-2.0 μg mL−1) and wine (0.5-2.0 μg mL−1) were 84.0-87.6%, 95.5-105.9% and 88.5-111.2%, respectively. The quantification limit for grapes was 0.021 mg Kg−1, being within European Union regulations, and 18 μg L−1 and 8 μg L−1 for must and wine, respectively.  相似文献   

14.
Headspace solid phase microextraction (HS-SPME) was investigated as a solvent-free alternative method for the extraction and determination of 4-ethylphenol (EP) and 4-ethylguaiacol (EG) in red wine by capillary gas chromatography with flame ionization detection (FID) and compared to liquid-liquid extraction.For HS-SPME, better results were obtained with saturated sodium chloride samples, at 55 °C, using a 85 μm polyacrylate fiber. An absorption time of 40 min was needed to reach the absorption equilibrium for EG. This 40-min duration corresponds to the beginning of EP equilibrium and was selected for the experiments. In these conditions, the calibration graphs were linear in the range 5-5000 μg l−1 and the sensitivity was nearly the same for the two compounds. The detection limits were in the low μg l−1 range. In model wine solutions, result obtained with the liquid-liquid extraction method exhibit a linear calibration between 25 and 10,000 μg l−1 with a detection limit of 1 μg l−1, but, the relative standard deviations of the EP and EG result in the low concentration range (<50 μg l−1) are higher than those obtained by HS-SPME (15% compared to 2% for EP and 12% compared to 5% for EG). Taking into account the numerous volatile compounds in wine, HS-SPME is a rapid and valid alternative technique for use in the determination of ethylphenols at trace levels.  相似文献   

15.
Comitre AL  Reis BF 《Talanta》2005,65(4):846-852
A not expensive automatic flow system based on multicommutation and exploiting the liquid-liquid extraction methodology for the determination of lead in plant material is described. The spectrophotometric procedure for lead determination was based on the reaction with dithizone followed by extraction using an organic solvent. The facilities afforded by the multicommutation approach allowed the use of an air stream as carrier, thus contributing to reduce the overall waste generation. The results obtained analysing plant materials compare very well with those obtained employing inductive coupled plasma optical emission spectrometry (ICP OES) at 90% confidence level. Others profitable features such as a linear response range between 50 and 200 μg l−1 Pb (r = 0.999); a sampling rate of 15 determination per hour; a relative standard deviation of 1.8% (n = 12) for a typical sample containing 163 μg l−1 Pb; a detection limit of 12 μg l−1; a reagent consumption of 4.5 mg dithizone; and a waste generation of 225 μl organic solvent per determination were also achieved.  相似文献   

16.
A novel simple, sensitive and rapid kinetic-spectrophotometric method is proposed for the determination of trace amounts of bromide. The method is based on its catalytic effect on the oxidation of methylene blue (MB) by hydrogen peroxide in strongly acidic solution. The oxidation reaction is activated by large amounts of chloride and can be monitored spectrophotometrically by measuring the decrease in the absorbance of MB at 746 nm. The determination of bromide is performed by a fixed-time method at the first 100 s from the initiation of the reaction. Unlike other kinetic-spectrophotometric methods for the determination of bromide, the proposed method does not require heating the solution. Bromide can be determined in the range from 80 to 960 μg l−1 with the detection limit of 35 μg l−1. The relative standard deviation of ten replicate determination of 480 μg l−1 bromide was 1.4%. The influence of potential interfering ions was studied. The proposed method was satisfactorily applied to the determination of bromide in seawater without interfering effect from chloride ion.  相似文献   

17.
Manju Gupta 《Talanta》2007,71(3):1039-1046
The aim of present work was to optimize the experimental parameters in single drop microextraction under solution immersion (SDME) and headspace (HS-SDME) extraction modes for the determination of periodate using guaifenesine [3-(2′-methoxyphenoxy)-1,2-propane diol] and norephedrine (phenylpropanolamine) as new and alternative reagents for the Malaprade reaction. The reactions were complete within 5 min resulting in the formation of 2-(2′-methoxyphenoxy)-acetaldehyde and benzaldehyde, respectively. SDME/HS-SDME of oxidation products with 2 μl of anisole or 1 μl of toluene, respectively, has permitted the determination of periodate at μg l−1 concentration levels. The results indicated that HS-SDME (range 0.01-10 mg l−1, r2 = 0.9990; limit of detection 1.55 μg l−1) was more sensitive than SDME (range 0.05-50 mg l−1, r2 = 0.9984; limit of detection 3.42 μg l−1), and was inexpensive, rapid and convenient. Tolerance of excess of iodate has permitted the application of this method in the determination of ethylene glycol in motor oil; the average recovery on spiked sample was 98.6% with R.S.D. of 4.2%.  相似文献   

18.
Erdem A  Eroğlu AE 《Talanta》2005,68(1):86-92
A selective matrix removal/separation/enrichment method, utilizing a microcolumn of a chelating resin with SH functional groups (Duolite GT-73), was proposed for the determination of Sb(III) in waters by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). The resin was selective to Sb(III) at almost all pH and acidity values employed, whereas Sb(V) was not retained at all and could be determined after a pre-reduction step with l-cysteine. Spike recoveries were tested at various concentration levels in different water types and were found to vary between 85 and 118%. Accuracy of the proposed methodology was checked by analyzing a standard reference material and a good correlation was found between the determined (13.3 ± 1.1 μg l−1) and the certified value (13.79 ± 0.42 μg l−1). The method was applied to several bottled drinking water samples for antimony determination with and without preconcentration and none of the samples were found to contain antimony above the permissible level (5 μg l−1). The characteristic concentration (the concentration of the analyte corresponding to an absorbance of 0.0044) was 0.55 μg l−1 and the 3 s limit of detection (LOD) based on five times preconcentration was 0.06 μg l−1. The applicability of the microcolumn separation/preconcentration/matrix removal method for flow injection systems was also demonstrated.  相似文献   

19.
Two methods of the determination of cobalt and chromium in human urine of non-occupationally exposed populations—highly sensitive catalytic adsorptive stripping voltammetry (CAdSV) and electrothermal atomic absorption spectrometry (ET-AAS)—are evaluated and compared. The CAdSV methods are based on adsorptive accumulation of a cobalt-nioxime (1,2-cyclohexanedione dioxime) or a chromium-DTPA (diethylenetriammine-N,N,N′,N″,N″-pentaacetic acid) complexes on a hanging mercury drop electrode, followed by a stripping voltammetric measurement of the catalytic reduction current of the adsorbed complex in the presence of sodium nitrite in case of cobalt or in the presence of sodium nitrate in case of chromium determination. In the CAdSV procedure UV-photolysis was used for the sample pre-treatment; the ET-AAS determination did not require any separate preliminary decomposition of the analyte urine samples. The accuracy of the procedures was checked by the analysis of commercially available quality control urine samples. The detection limits (3σ) were 0.13 μg l−1 for Co and 0.18 μg l−1 for Cr in ET-AAS determination and 0.007 μg l−1 for Co and 0.002 μg l−1 for Cr in CAdSV measurements. Precision (R.S.D.) was less than 5% for both methods. The study has shown that the CAdSV is a more reliable and sensitive technique for the determination of very low cobalt and chromium contents in urine, the detection of which is not possible when using the AAS technique.  相似文献   

20.
A liquid-liquid extraction flow analysis procedure for the spectrophotometric determination of molybdenum in plants at μg l−1 level is described. The flow network comprised a set of solenoid valves assembled to implement the multicommutation approach under microcomputer control. Radiation source (LED, 475 nm), detector (photodiode) and separation chamber were nested together with the flow cell comprising a compact unit. The consumption of reagents (potassium thiocyanate and stannous chloride) and also extracting solvent (isoamyl alcohol) were optimized to 32 mg and 200 μl per determination, respectively. Accuracy was assessed by comparing results with those obtained with ICP-OES and no significant difference at 95% confidence level was observed. Other favorable characteristics such as a linear response ranging from 25 to 150 μg l−1 molybdenum (r=0.999); detection limit of 4.6 μg l−1 sample throughput of 25 determinations per hour and relative standard deviation of 2.5% (n=10) were also achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号