首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Feng HT  Wei HP  Li SF 《Electrophoresis》2004,25(6):909-913
A portable chip-CE system with potential gradient detection (PGD) was developed and applied to the determinations of alkali metals and alkaloids. The separation efficiency appeared to be satisfactory and nonaqueous capillary electrophoresis (NACE) proved to be applicable to PGD or conductivity detection. The power supplies, separation and detection were built on a device of 3 kg in weight. A branch channel near the end of the separation channel was designed to perform PGD and make the application of relatively high field strength possible. The study is the first report on the application of PGD on the microchip platform. The design of the chip-CE system shows several advantages, such as simplicity, miniaturization and wide applicability.  相似文献   

2.
3.
The combined flow injection (FI)-capillary electrophoresis (CE) system was further exploited by coupling to an electrogenerated chemiluminescence (ECL) detection system. A low-cost miniaturized CE system was developed on a chip platform to provide easy interface both with FI sample introduction and with ECL detection. A falling-drop interface was employed to perform FI split-flow sample introduction while achieving electrical isolation from the CE high voltage. A plexiglas reservoir at the capillary outlet served as both the reaction and detection cell for the ECL reaction, with Ru(bpy)32+ reagent continuously flowing through the cell. An optical fiber was positioned within the reservoir close to the capillary outlet for transferring the ECL emission to the PMT. The relative positions of the capillary outlet, working electrode and optical fiber as well as reagent renewal flow-rate were optimized to achieve both good sensitivity and separation efficiency under non-interrupted sampling conditions, involving large numbers of samples. An on-column joint often used in other works for isolating the ECL detection system from the CE separation voltage was not found necessary. The performance of the system was illustrated by the baseline separation of proline, valine and phenylalanine with a high throughput of 50 h−1 and plate height of 14 μm for proline under 147 V cm−1 field strength. Detection limits (3σ) were 1.2, 50 and 25 μM and peak height precisions were 1.4, 5.4 and 4.3% R.S.D. (n=9) for proline, valine and phenylalanine, respectively.  相似文献   

4.
A sequential injection micro-sample introduction system was coupled to a microfluidic-chip based capillary electrophoresis system through a split–flow sampling interface integrated on the micro-chip. The microfluidic system measured 20×70×3 mm in dimension, and was produced using a non-lithographic approach with components readily available in the analytical laboratory. In the H-configuration channel design the horizontal separation channel was a 75 μm I.D.×60 mm quartz capillary, with two vertical side arms produced from plastic tubing. The conduits were embedded in silicon elastomer with a planar glass base. Sequential introduction of a series of samples with about 2.5% carryover was achieved at 48 h−1 throughput with samples containing a mixture of fluorescein isothiocyanate (FITC)-labeled amino acids using SI sample volumes of 3.3 μl and carrier flow-rate of 2.0 ml min−1. Baseline separation was achieved for FITC-labeled arginine, phenylalanine, glycine and FITC (laser induced fluorescence detection) in sodium tetraborate buffer (pH 9.2) within 8–80 s, at separation lengths of 25–35 mm and electrical field strengths of 250–1500 V cm−1, with plate heights in the 0.7–3 μm range.  相似文献   

5.
Wu XZ  Zhang LH  Onoda K 《Electrophoresis》2005,26(3):563-570
Carrier ampholyte-free isoelectric focusing (IEF) sample injection (concentration) for capillary electrophoresis (CE) is realized in a single capillary. A short section of porous capillary wall was made near the injection end of a capillary by HF etching. In the etching process, an electric voltage was applied across the etching capillary wall and electric current was monitored. When an electric current through the etching capillary was observed, the capillary wall became porous. The etched part was fixed in a vial, where NaOH solution with a certain concentration was added during the sample injection. The whole capillary was filled with pH 3.0 running buffer. The inlet end vial was filled with protein sample dissolved in the running buffer. An electric voltage was applied across the inlet end vial and etched porous wall. A neutralization reaction occurs at the boundary (interface) of the fronts of H+ and OH-. A pH step or sharp pH gradient exists across the boundary. When positive protein ions electromigrate to the boundary from the sample vial, they are isoelectricelly focused at points corresponding to their pH. After a certain period of concentration, a high voltage is applied across the whole capillary and a conventional CE is followed. An over 100-fold concentration factor has been easily obtained for three model proteins (bovine serum albumin, lysozyme, ribonuclease A). Furthermore, the IEF sample concentration and its dynamics have been visually observed with the whole-column imaging technique. Its merits and remaining problem have been discussed, too.  相似文献   

6.
Chen G  Zhang L  Wang J 《Talanta》2004,64(4):1018-1023
Multi-walled carbon nanotube (CNT) was mixed with epoxy to fabricate microdisc electrode used as a detector for a specially designed miniaturized capillary electrophoresis (CE)-amperometric detection system for the separation and detection of several bioactive thiols. The end-channel CNT amperometric detector offers favourable signal-to-noise characteristics at a relatively low potential (0.8 V) for detecting thiol compounds. Factors influencing the separation and detection processes were examined and optimized. Four thiols (homocysteine, cysteine, glutathione, and N-acetylcysteine) have been separated within 130 s at a separation voltage of 2000 V using a 20 mM phosphate running buffer (pH 7.8). Highly linear response is obtained for homocysteine, cysteine, glutathione, and N-acetylcysteine over the range of 5-50 μM with detection limits of 0.75, 0.8, 2.9, and 3.3 μM, respectively. Good stability and reproducibility (R.S.D. < 5%) are obtained reflecting the minimal adsorption of thiols at the CNT electrode surface. The new microchip protocol should find a wide range of bioanalytical applications involving assays of thiol compounds.  相似文献   

7.
In the present study, field-amplified sample stacking injection using the electroosmotic flow pump (FAEP) was developed for the capillary electrophoretic separation of the four nerve agent degradation products methylphosphonic acid (MPA), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA) and cyclohexyl methylphosphonic acid (CMPA). Coupled to contactless conductivity detection, direct quantification of these non-UV active compounds could be achieved. Sensitivity enhancement of up to 500 to 750-fold could be obtained. The newly established approach was applied to the determination of the analytes in river water and aqueous extracts of soil. Detection limits of 0.5, 0.7, 1.4 and 2.7 ng/mL were obtained for MPA, EMPA, IMPA and CMPA, respectively, in river water and 0.09, 0.14, 0.44 and 0.22 μg/g, respectively, in soil.  相似文献   

8.
Hsiung SK  Lin CH  Lee GB 《Electrophoresis》2005,26(6):1122-1129
We present a new microfluidic device utilizing multiwavelength detection for high-throughput capillary electrophoresis (CE). In general, different fluorescent dyes are only excited by light sources with appropriate wavelengths. When excited by an appropriate light source, a fluorescent dye emits specific fluorescence signals of a longer wavelength. This study designs and fabricates plastic micro-CE chips capable of performing multiple-wavelength fluorescence detection by means of multimode optic fiber pairs embedded downstream of the separation channel. For detection purposes, the fluorescence signals are enhanced by positioning microfocusing lens structures at the outlets of the excitation fibers and the inlets of the detection fibers, respectively. The proposed device is capable of detecting multiple samples labeled with different kinds of fluorescent dyes in the same channel in a single run. The experimental results demonstrate that various proteins, including bovine serum albumin and beta-casein, can be successfully injected and detected by coupling two light sources of different wavelengths to the two excitation optic fibers. Furthermore, the proposed device also provides the ability to measure the speed of the samples traveling in the microchannel. The developed multiwavelength micro-CE chip could have significant potential for the analysis of DNA and protein samples.  相似文献   

9.
Chen G  Bao H  Yang P 《Electrophoresis》2005,26(24):4632-4640
A microchip CE-amperometric detection (AD) system has been fabricated by integrating a two-dimensionally adjustable CE microchip and an AD cell containing a one-dimensionally adjustable disk detection electrode in a Plexiglas holder. It facilitates the precise 3-D alignment between the channel outlet and the detection electrode without a complicated 3-D manipulator. The performance of this unique system was demonstrated by separating five aromatic amines (1,4-phenyldiamine, aniline, 2-methylaniline, 4-chloroaniline, and 1-naphthylamine) of environmental concern. Factors influencing their separation and detection processes were examined and optimized. The five analytes have been well separated within 140 s in a 74 cm long separation channel at a separation voltage of +2500 V using a 10 mM phosphate buffer (pH 3.5). Highly linear response is obtained for the five analytes over the range 20-200 microM with the detection limits ranging from 0.46 to 1.44 microM, respectively. The present system demonstrated long-term stability and reproducibility with RSDs of less than 5% for the peak current (n = 9). The new approach for the microchannel-electrode alignment should find a wide range of applications in CE, flowing injection analysis, and other microfluidic analysis systems.  相似文献   

10.
The performance of an integrated capillary electrophoresis system with a novel split-flow sample injection mechanism and special high sensitivity UV absorbance detector is described. Sample introduction into the capillary is accomplished with a standard HPLC-type microliter syringe. The injected sample is divided proportionally between the separation capillary and an adjustable splitvent. The volume of sample introduced into the capillary can be manipulated by varying the length or the i.d. of the splitvent tubing; or the volume of sample injected. Data are presented showing reproducibility of retention time, peak height, and peak area; minimum detectability; and operation at short UV wavelengths.  相似文献   

11.
刘军  方群  杜文斌 《分析化学》2005,33(12):1799-1802
将基于缺口型试样管阵列的微流控试样引入系统与紫外检测-毛细管电泳系统联用,建立可实现自动化、高通量、连续试样引入的微型化毛细管电泳系统。试样引入系统由底部加工有缺口的试样管阵列构成,阵列固定于一维平移台上。实验时,通过平移试样管阵列,使毛细管和电极依次经缺口进入装有试样或缓冲液的试样管内,完成电动进样和电泳分离操作。该系统被用来快速分离复方新诺明片中的磺胺甲嗯唑(SMZ)和甲氧苄氨嘧啶(TMP),以考察系统分析性能。分析通量达到72样/h,试样间携出量为1.4%,对SMZ的分离塔板高度11μm。采用紫外检测对SMZ和TMP检出限(3σ)分别为9.8mg/L和12.2mg/L。  相似文献   

12.
The fast separation capability of a novel miniaturized capillary electrophoresis with amperometric detection (CE-AD) system was demonstrated by determining sugar contents in Coke and diet Coke with an estimated separation efficiency of 60,000 TP/m. Factors influencing the separation and detection processes were examined and optimized. The end-capillary 300 microm Cu wire amperometric detector offers favorable signal-to-noise characteristics at a relatively low potential (+0.50 V vs. Ag/AgCl) for detecting sugars. Three sugars (sucrose, glucose, and fructose) have been separated within 330 s in a 8.5 cm length capillary at a separation voltage of 1000 V using a 50 mM NaOH running buffer (pH 12.7). Highly linear response is obtained for the above compounds over the range of 5.0 to 2.0 x 10(2) microg/mL with low detection limit, down to 0.8 microg/mL for glucose (S/N = 3). The injection-to-injection repeatability for analytes in peak current (RSD < 3.6%) and for migration times (RSD < 1.4%) was excellent. The new miniaturized CE-AD system should find a wide range of analytical applications involving assays of carbohydrates as an alternative to conventional CE and micro-CE.  相似文献   

13.
An automatic, rapid and continuous on-line derivatization system coupled to microfluidic capillary electrophoresis (CE) for the determination of amino acids using o-phthaldialdehyde/N-acetyl-l-cysteine (OPA/NAC) as the derivative agents has been developed. By on-line derivatization, amino acids were automatically and reproducibly converted to the UV-absorbing derivatives, which were separated by capillary zone electrophoresis (CZE). Optimization of derivatization and separation condition was carried out to achieve both good sensitivity and separation efficiency. The separation could be achieved within 4 min and sample throughput rate can reach up to 16 h−1. The repeatability (defined as relative standard deviation, R.S.D.) was 2.56, 2.85, 3.24 and 3.60% with peak area evaluation and 2.93, 3.12, 4.20 and 4.91% with peak height evaluation for arginine (Arg), phenylalanine (Phe), serine (Ser) and glycine (Gly), respectively. The limits of detection (S/N=3) were 10.46, 13.14, 34.39 and 44.79 μmol/l for Arg, Phe, Ser and Gly, respectively. Major advantages of the proposed method include improved precision and efficient automation of the derivatization by the FI system and the enhanced sampling frequencies by the combined FI-CE system.  相似文献   

14.
Hadamard transform capillary electrophoresis (HTCE) based on electrokinetic injection allows laser-induced fluorescence detection using a small laser, namely the laser-diode-pumped YAG laser, as an excitation source. A small hole is fabricated at the center of a capillary by laser ablation; this hole functions as an inlet port for a sample solution. Therefore, the sample solution can be introduced electrophoretically into the capillary through the small hole. Multiple sample injection is accomplished by introducing a buffer solution from the end of the capillary and the sample solution through the hole. Both solutions are injected using two sets of high-voltage power supplies and migrate toward the opposite end of the capillary. A fluorescent analyte, rhodamine B, is successfully detected in the case of both single and multiple injection according to the Hadamard sequence code. By transforming the data encoded by the Hadamard matrix, the decoded data showed an increase in the signal-to-noise (S/N) ratio by a factor of 9.8. In the case of the sample containing two amino acids labeled with rhodamine B isothiocyanate (RBITC), although the concentration of every component including free RBITC is lower than the concentration limit of detection obtained by single injection, a substantial improvement in the sensitivity is achieved and all components are identified by the Hadamard transform technique.  相似文献   

15.
In this work, a combined methodology using off-line solid-phase extraction (SPE), on-line field-enhanced sample injection (FESI) and coelectroosmotic capillary electrophoresis with UV detection (CE-UV) is developed for the trace analysis of five triazolopyrimidine sulfonanilide pesticides (i.e., flumetsulam, florasulam, cloransulam-methyl, diclosulam and metosulam). An adequate background electrolyte (BGE) was obtained for the separation of these pesticides using hexadimethrine bromide (HDB) as electroosmotic flow (EOF) modifier. This BGE consisted of 0.00042% HDB, 11 mM formic acid, 16 mM ammonium carbonate and 2.5 mM alpha-CD solution at pH 7.6. The use of this running buffer together with the FESI preconcentration method provided limits of detection (LODs) in the low microg/L range (i.e., between 13.0 and 31.5 microg/L). The optimized FESI-CE-UV method was combined with off-line SPE using C(18) cartridges and applied to the determination of the selected group of pesticides in soil samples. Recovery percentages ranged between 50 and 84% in these samples with LODs between 18 and 34 microg/kg. This work shows the great possibilities of the combined use of SPE-FESI-CE-UV to improve CE sensitivity allowing the achievement of LODs similar to other analytical techniques as GC or HPLC.  相似文献   

16.
A capillary electrophoretic method with UV detection for separation and quantitation of perfluorocarboxylic acids (PFCAs) from C6-PFCA to C12-PFCA has been developed. The optimization of measurement conditions included the choice of the most appropriate type and concentration of buffer in the background electrolyte (BGE), as well as the type and the content of an organic modifier. The optimal separation of investigated PFCAs was achieved with 50 mM phosphate buffer and 40% isopropanol in the BGE using direct UV detection. The optimum wavelength for direct UV detection was optimized at 190 nm. For indirect detection, several chromophores were studied. Five mM 3,5-Dinitrobenzoic acid (3,5-DNBA) in 20 mM phosphate buffer BGE and indirect UV detection at 280 nm gave the optimal detection and separation performance for the investigated PFCAs. The possibility of on-line preconcentration of solutes by stacking has been examined for indirect detection. The detection limits (LODs) determined for direct UV detection ranged from 2 microg/mL for C6-PFCA to 33 microg/mL for C12-PFCA. The LODs obtained for indirect UV detection were comparable to those obtained for direct UV detection.  相似文献   

17.
A microchip-based capillary electrophoresis device supported by a microfluidic network made of poly(dimethylsiloxane), used for measuring target analytes from a continuous sample flow, is presented. The microsystem was fabricated by means of replica molding in combination with standard microfabrication technologies, resulting in microfluidic components and an electrochemical detector. A new hydrodynamic sample injection procedure is introduced, and the maximum number of consecutive measurements that can be made with a poly(dimethylsiloxane) capillary electrophoresis chip with amperometric detection is investigated with respect to reproducibility. The device features a high degree of functional integration, so the benefits associated with miniaturized analysis systems apply to it.  相似文献   

18.
《Electrophoresis》2018,39(14):1754-1762
A novel and fully automated sequential injection analysis manifold coupled to a capillary electrophoresis apparatus with amperometric detection, is described. The sequential injection manifold was isolated from the high voltage by inserting an air plug into the circuit. Small buffer reservoirs were used to avoid the need to pump fresh buffer to the interface during the electrophoretic separation. No decoupling device was used to mitigate the interference from the high voltage electric field, instead the potential shift induced by the separation voltage, was accounted for. The new hydrodynamic injection method presented is based on the overpressure created in the circuit when a pinch valve is closed for a predetermined time. The injection method yields RSD values of peak height and area below 2.55 and 1.82%, respectively, at different durations of valve closure (n = 5). The capillary and working electrode alignment was achieved by adapting a commercial available capillary union. When the electrode was replaced, the alignment method proved to be very reliable, yielding RSD values of peak height and area lower than 2.64 and 2.08%, respectively (n = 8). Using this system with a gold microelectrode, dopamine, and epinephrine could be quantified within the concentration range of 1–500 μM and detected at a concentration of 0.3 μM. The methods here presented could be applied for the development of new capillary electrophoresis systems with amperometric detection and/or to the design of fully automated systems for online process monitoring purposes.  相似文献   

19.
Solvent-bar microextraction (SBME) based on two-phase (water-to-organic) extraction was for the first time used as the sample pretreatment method for the non-aqueous capillary electrophoresis (NACE) of herbicides of environmental concern. Due to the compatibility of the extractant organic solvent and the NACE separation system, the extract could be introduced directly to the CE system after SBME. Through investigations of the effect of sample pH, extraction time, agitation speed and salt addition on extraction efficiency, the most suitable extraction conditions were determined: sample solution at a pH of 1, without added salt, and stirring at 700 revolutions per minute for 30 min. SBME as applied here was also compared with single-drop microextraction and hollow fiber-protected liquid-phase microextraction. SBME showed the highest extraction efficiency. In addition, field-amplified sample injection with pre-introduced organic solvent plug removal using the electroosmotic flow as a pump (FAEP) was used to enhance the sensitivity further in NACE. Based on studies of the effect of different organic solvents, different lengths of the organic plugs and different volumes of sample injection on stacking efficiency under the most suitable separation conditions, methanol was found to be the most efficient solvent for on-line preconcentration. Combined with SBME, FAEP-NACE achieved limits of detection of between 0.08 ng/mL and 0.14 ng/mL for the studied analytes. This preconcentration approach for NACE was demonstrated to be amenable to aqueous environmental samples by applying it to spiked river water.  相似文献   

20.
Fan L  Cheng Y  Li Y  Chen H  Chen X  Hu Z 《Electrophoresis》2005,26(22):4345-4354
A simple, effective, and continuous online concentration method for the sensitive detection of alkaloids applying CE-flow injection analysis with head-column field-amplified sample stacking was developed. A series of samples was continuously introduced into the capillary by electrokinetic means without interrupting the high voltage. A short water plug was introduced by the EOF at the capillary inlet end prior to sample introduction. Under optimum conditions, 15-fold improvement in concentration sensitivity was achieved, giving an LOD of about 0.67 and 0.73 microg/mL for ephedrine (E) and pseudoephedrine (PE), respectively. The separation could be achieved within 4 min and sample throughput rate could reach up to 7/h. The repeatability (defined as RSD) was 3.62, 1.51% with peak area evaluation and 1.30, 2.58% with peak height evaluation for E and PE, respectively. This method has been successfully applied to the analysis of commercial pharmaceutical preparations containing E and PE, and the recoveries were 92.3-102.4%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号