首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 28 毫秒
1.
A flow injection on-line sorption preconcentration system has been synchronously coupled to an electrothermal atomic absorption spectrometry (ETAAS) system for the selective determination of trace amounts of Sb(III) in water, soil and plant. The determination was achieved by selective complexation and sorption of Sb(III) with [1,5-bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydarzide (PSTH) immobilized on an anion-exchange resin (Dowex 1× 8-200)] at a wide range of pH, quantitative elution with 50 μl of 2 M HNO3 and subsequent ETAAS detection. ETAAS determination of the analyte was performed in parallel with the preconcentration of the next sample. Using a preconcentration time of 60 s and a sample loading flow rate of 2.8 ml min−1, an enhancement factor of 12 was obtained in comparison with direct injection of 50 μl aqueous solution, resulting in a sampling frequency of 31 samples h−1. The detection limit (3 s) was 2 μg l−1 and the precision was 3.1% (R.S.D.) for 11 replicate determinations at 10 μg l−1. The accuracy of the proposed method was demonstrated by analyzing one certified sample and different spiked samples.  相似文献   

2.
A new, simple and sensitive spectrofluorimetric method for the determination of salicylic acid (λex = 315 nm, λem = 408 nm) using As(III) as a sensitizing reagent has been investigated by measuring the increase of fluorescence intensity of salicylic acid due to the complexation of As(III)-salicylic acid in presence of sodium dodecyl sulfate (SDS) 10−3 M. Under optimum conditions, a significant relationship was obtained between the fluorescence intensity and salicylic acid concentration. A linear calibration curve was obtained in the range 13.8-13812 μg l−1 with product-moment correlation coefficient (R) 0.99985 and detection limit 4.2 μg l−1. The R.S.D. is 2.35% (n = 5).The method was applied successfully to the determination of salicylic acid in human serum.  相似文献   

3.
Marta Knap 《Talanta》2007,71(1):406-410
An on-line preconcentration procedure for the determination of manganese using flow-injection approach with flame atomic absorption spectrometry as a detection method is described. The proposed method is based on the complexation between Mn(II) and 5,10,15,20-tetrakis(4-carboxyphenyl)porphyrin (TCPP). Two approaches were investigated for enrichment of manganese; the formation of Mn-TCPP complex in a solution followed by its retention on a sorbent and the sorption of manganese ions onto the TCPP-modified resin. The best results was obtained for the first approach when 10−5 M reagent was on-line mixed with an aqueous sample solution and passed through the microcolumn packed with anion-exchange resin Amberlite IRA-904 for 5 min. The sorbed complexes were then eluted with 0.5 ml of 2 M HNO3. A good precision (2.2-3.1% R.S.D. for 50 μg l−1 manganese) and the enrichment factor of 30 were obtained with the detection limit of 12 μg l−1 for 5 min loading time. The interference of anions and cations has been studied to optimize the conditions and the method was applied for determination of manganese in natural water samples. The results obtained by FI-FAAS and ETAAS (as a reference method) were not statistically different for a significance level of 0.05.  相似文献   

4.
This paper describes a highly sensitive, selective catalytic-kinetic-spectrophotometric method for the determination of copper(II) concentration as low as 6 ng ml−1. The method is based on the catalytic effect of copper(II) on the oxidation of citric acid by alkaline hexacyanoferrate(III). The reaction was followed by measuring the decrease in absorbance of hexacyanoferrate(III) at 420 nm (λmax of [Fe(CN)6]3−,  = 1020 dm3 mol−1 cm−1). The dependence of rate of the indicator reaction on the reaction variables has been studied and discussed to propose a suitable mechanism to get a relation between the reaction rate and [Cu2+]. A fixed time procedure has been used to obtain a linear calibration curve between the initial rate and lower [Cu2+] or log[Cu2+] in the range 1 × 10−7 to 4 × 10−4 mol l−1 (6.35-25,400 ng ml−1). The detection limit has been calculated to be 4 ng ml−1. The maximum average error is 3.5%. The effect of the presence of various cations, commonly associated with copper(II) and some anions has also been investigated and discussed. The proposed method is sensitive, accurate, rapid and inexpensive compared to other techniques available for determination of copper(II) in such a large range of concentration. The new method has been successfully applied for the determination of copper(II) in various samples.  相似文献   

5.
Synergistic liquid-liquid extractive spectrophotometric determination of gold(III) using 1-(2′,4′-dinitro aminophenyl)-4,4,6-trimethyl-1,4-dihydro pyrimidine-2-thiol [2′,4′-dinitro APTPT] has been described. Equal volumes (5 cm3) of the 2′,4′-dinitro APTPT (0.02 mol L−1) in the presence of pyridine (0.5 mol L−1) form an orange-red coloured ternary complex with gold(III) of molar ratio 1:1:1 at pH 1.8-2.4 with 5 min of shaking. The absorbance of coloured organic layer in 1,2-dichloroethane is measured spectrophotometrically at 445 nm against reagent blank. A pronounced synergism has been observed by the binary mixture of 2′,4′-dinitro APTPT and pyridine, which shows that the enhancement in the absorbance is observed in the presence of pyridine by the adduct formation in the organic phase. Beer's law was obeyed in the concentration range 2.5-20.0 μg mL−1, with molar absorptivity and Sandell's sensitivity values of 8.7 × 103 dm3 mol−1 cm−1 and 0.023 μg cm−2 respectively. A repetition of the method was checked by finding relative standard deviation (R.S.D.) (n = 10) which was 0.17%. The composition of the gold(III)-2′,4′-dinitro APTPT-pyridine adduct was established by slope analysis, molar ratio and Job's method. The ternary complex was stable for more than 48 h. The influence of various factors such as pH, 2′,4′-dinitro APTPT concentration, solvent and pyridine on the degree of complexation has been established. A number of foreign ions tested for their interferences and use of suitable masking agents wherever necessary are tabulated, which show that selectivity of the method has been enhanced. The method is successfully employed for the determination of gold(III) in binary, synthetic mixtures and ayurvedic samples. The reliability of the method is assured by inter-comparison of experimental values, using an atomic absorption spectrometer.  相似文献   

6.
A simple, fast chemiluminescence (CL) flow-injection (FI) method based on the reaction of luminol with KMnO4 in alkaline medium has been described for the direct determination of carbofuran. The method is based on the enhancing effect in the emission light from the oxidation of luminol produced in presence of carbofuran. The optimisation of instrumental and chemical variables influencing the CL response of the method has been carried out by applying experimental design, using the proposed flow-injection manifold. Under the optimal conditions, the CL intensity was linear for a carbofuran concentration over the range of 0.06-0.5 μg ml−1, with a detection limit of 0.02 μg ml−1. The method has been successfully applied to the determination of carbofuran residues in spiked water and lettuce samples.  相似文献   

7.
Itoh J  Liu J  Komata M 《Talanta》2006,69(1):61-67
A novel indirect substitution spectrophotometric methodology using porphyrin is developed for the determination of some metals that do not react with porphyrin directly. The methodology is concerned with a multistep reaction system, which consists of 3 complexation reactions that occur in a sequence of EDTA with metal, EDTA with Cu(II) and porphyrin with Cu(II). The complexation reaction of Cu(II) with a cationic porphyrin, meso-tetrakis (4-N-trimethylaminophenyl)-porphine (ttmapp), which has a high molar absorptivity about 5 × 105 l mol−1 cm−1, serves for spectrophotometric detection. This methodology was verified through individual determinations of 14 species of lanthanides following a batchwise procedure, which was further developed to an automatic procedure on a HPLC post-column flow injection system for simultaneous analysis of the lanthanides. Compared with the conventional post-column derivatization method using 4-(2-pyridylazo) resorcinol (PAR), the analytical sensitivity was greatly improved in this method and the results also showed good linearity.  相似文献   

8.
A cloud point extraction (CPE) method has been developed for the preconcentration of trace aluminum prior to its determination by flame atomic absorption spectrometry (FAAS). The CPE method is based on the complex of Al(III) with Xylidyl Blue (XB) and then entrapped in non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of XB and Triton X-114, equilibration temperature and time, were investigated in detail. An enrichment factor of 50 was obtained for the preconcentration of Al(III) with 50 mL solution. Under the optimal conditions, the detection limit of this method for Al(III) is 1.43 μg L− 1, and the relative standard deviation is 2.7% at determination of 100 μg L− 1 Al(III). The proposed method has been applied for determination of trace amount of aluminum in mineral water samples with satisfactory results. Also, the proposed method was applied to the certified reference materials. The results obtained were in good agreement with certified values.  相似文献   

9.
A novel method for preconcentration of methylmercury and inorganic mercury from water samples was developed involving the determination of ng l−1 levels of analytes retained on the silica C18 solid sorbent, previous complexation with ammonium pyrrolidine dithiocarbamate (APDC), by slurry sampling cold vapor atomic absorption spectrometry (SS-CVAAS) in a flow injection (FI) system. Several variables were optimized affecting either the retention of both mercury species, such as APDC concentration, silica C18 amount, agitation times, or their determination, including hydrochloric acid concentration in the suspension medium, peristaltic pump speed and argon flow-rate. A Plackett-Burman saturated factorial design permitted to differentiate the influential parameters on the preconcentration efficiency, which were after optimized by the sequential simplex method. The contact time between mercury containing solution and APDC, required to reach an efficient sorption, was decreased from 26 to 3 min by the use of sonication stirring instead of magnetic stirring. The use of 1 mol dm−3 hydrochloric acid suspension medium and 0.75% (m/v) sodium borohydride reducing agent permitted the selective determination of methylmercury. The combination of 5 mol dm−3 hydrochloric acid and 10−4% (m/v) sodium borohydride was used for the selective determination of inorganic mercury. The detection limits achieved for methylmercury and inorganic mercury determination under optimum conditions were 0.96 and 0.25 ng l−1, respectively. The reliability of the proposed method for the determination of both mercury species in waters was checked by the analysis of samples spiked with known concentrations of methylmercury and inorganic mercury; quantitative recoveries were obtained.  相似文献   

10.
Ribeiro PR  Neto JA  Pezza L  Pezza HR 《Talanta》2005,67(1):240-244
A flow-injection spectrophotometric procedure is proposed for methyldopa determination in pharmaceutical preparations. The determination is based on formation of a yellow product (measured at 410 nm) after complexation of methyldopa with molybdate. Under optimal conditions, Beer's law is obeyed in a concentration range of 50-200 mg l−1 methyldopa. Typical correlation between absorbance and analyte concentration was 0.9999. Usual excipients used as additives in pharmaceuticals do not interfere with the proposed method. The analytical frequency was 210 h−1 and the relative standard deviation (R.S.D.) was ≤2% for sample solution containing 150 mg l−1 methyldopa (n = 11). The analytical results obtained in commercial formulations by applying the proposed FIA method were in good agreement with labeled values and those obtained by the Brazilian Pharmacopoeia procedure at 95% confidence level.  相似文献   

11.
The reactions of 4-chloro-7-nitrobenzofurazan (NBD-Cl) with glyphosate (GLY) and with its main metabolite, aminomethylphosphonic acid (AMPA), have been studied. The resolution of binary mixtures of glyphosate and aminomethylphosphonic acid has been accomplished by partial least squares (PLS) multivariate calibration. The method of determination is based on the fluorescence emission of the derivatives formed in presence of NBD-Cl at 90 °C, in methanol and in basic medium. The dynamic ranges of the methods were comprised between 10 and 150 μg l−1 for GLY and between 10 and 200 μg l−1 for AMPA, being the detection limits 2 and 5.4 μg l−1 for GLY and AMPA, respectively. The total luminiscence information of the derivatives has been used to optimize the spectral data set to perform the calibration, by analysis of the three-dimensional excitation-emission matrices. A comparison between the predictive ability of the multivariate calibration method, partial least squares type 1 (PLS-1), on two spectral data sets, emission and synchronous spectra, has been performed. The PLS-1 method, applied to the emission spectra, has been selected as optimum. The proposed method has been applied to the simultaneous determination of GLY and AMPA in river water. For concentrations ranging from 100 to 600 μg l−1 of each compound in the samples, analytical recoveries range from 83 to 94% for GLY and from 104 to 120% for AMPA.  相似文献   

12.
Ayata S  Bozkurt SS  Ocakoglu K 《Talanta》2011,84(1):212-215
A new method based on microcolumn packed with ionic liquid-modified silica combined with flame atomic absorption spectrometry has been developed for the determination of lead in environmental samples. Several factors influencing the preconcentration efficiency of lead and its subsequent determination, such as pH of the sample, flow rate, mass of ionic liquid, and interfering effect, have been investigated. Lead could be quantitatively retained by ionic liquid-modified silica in the pH range of 5-7, and then eluted completely with 3.0 mL 1.0 mol L−1 HCl. The detection limit of this method for lead was 0.7 μg L−1 with preconcentration factor of 185, and the relative standard deviation (RSD) was 4.2% at 0.1 μg mL−1 Pb(II). This method has been applied for the determination of trace amount of lead in NIST standard reference material 2709 (San Joaquin Soil) and river water samples with satisfactory results.  相似文献   

13.
The H-point standard addition method (HPSAM) was applied to kinetic data for simultaneous determination of Sb(V) and Sb(III) and also selectively determines Sb(V) in the presence of Sb(III). The method is based on the differences between rate of complexation of pyrogallol red with Sb(V) and Sb(III) at pH=2. Sb(V) can be determined in the range of 0.3-2.0 μg ml−1 with satisfactory accuracy and precision in the presence of excess Sb(III). Good selectivity was obtained over the variety of metal ions. The proposed method was used for determination of Sb(V) and Sb(III) in river and spring water samples.  相似文献   

14.
Zhong H  Li N  Zhao F  Li KA 《Talanta》2004,62(1):37-42
A new protein determination method by enhanced Rayleigh light scattering (RLS) technique has been developed. In acid condition (pH=3.60), RLS of 1,2-dihydroxyanthraquinone-3-sulfonate (Alizarin Red S) can be greatly enhanced by addition of proteins, resulting in two characteristic peaks, 360 and 505 nm, respectively. The new protein assay is based on the RLS enhancement and spectrum change. The optimum condition for the reaction was investigated. The linear range is 0.20-24.9 μg ml−1 for BSA and 0.20-15.5 μg ml−1 for HSA. The detection limits (S/N=3) are 9.59 ng ml−1 for BSA and 9.51 ng ml−1 for HSA. The results of determination for human serum samples were comparable to those obtained by Bradford method. The binding stoichiometry was determined.  相似文献   

15.
A new method has been developed for the determination of gold based on separation and preconcentration with a microcolumn packed with nanometer TiO2 immobilized on silica gel (immobilized nanometer TiO2) prior to its determination by flame atomic absorption spectrometry. The optimum experimental parameters for preconcentration of gold, such as pH of the sample, sample flow rate and volume, eluent and interfering ions, have been investigated. Gold could be quantitatively retained by immobilized nanometer TiO2 in the pH range of 8-10, then eluted completely with 0.1 mol L−1 HNO3. The detection limit of this method for Au was 0.21 ng mL−1 with an enrichment factor of 50, and the relative standard deviation (R.S.D.) was 1.8% at the 100 ng mL−1 Au level. The method has been applied for the determination of trace amounts of Au in geological and water samples with satisfactory results.  相似文献   

16.
A novel, inexpensive and fast method based on the electrooxidation of glycerol on platinum electrodes by the potential cycling technique has been designed for the determination of free glycerol in biodiesel. A wide range of linearity was achieved between 15 and 150 mg L−1 (0.16 and 1.6 mmol L−1), which corresponds to concentrations ranging between 56 and 560 mg kg−1 (glycerol:biodiesel) for an extraction using 2 g biodiesel. A method for the fast extraction of glycerol from biodiesel with water followed by elimination of organic interferents has also been developed, so that the novel determination method can be applied to various biodiesel samples. The excellent repeatability allows determination of glycerol in numerous samples, with no need for recalibration.  相似文献   

17.
A novel method for the determination of trace amounts of Al(III) based on resonance Rayleigh scattering (RRS) has been developed. In the presence of some surfactants, Al(III) can react with morin and form an Al(III)-morin-surfactant complex, which results in the enhancement of RRS intensity and the appearance of the corresponding RRS spectral characteristics. Their maximum scatter peaks are at 476 nm for the cetyltrimethylammonium bromide (CTAB) system, 489 nm for the cetylpyridinium chloride (CPC) system, 474 nm for the Triton X-100 system, and 473 nm for the Tween-20 system. The enhanced RRS intensity is directly proportional to the concentration of Al(III). The detection limits are in the range of (0.50-1.2)×10−7 mol l−1 depending on the surfactant. The characteristics of RRS spectra of the complexes, the optimum conditions of these reactions and the influencing factors have been investigated. The method has high selectivity, and was successfully applied to the determination of Al(III) in natural and biological samples. Furthermore, according to different complexation capacity of Al(III)-morin-CTAB system under two pH conditions, speciation analysis of Al(III) in natural waters was explored. The labile monomeric Al fraction (mainly inorganic Al, Ali) is determined at acidic pH and the total monomeric Al fraction (Ala) is determined at alkaline pH. The results are in agreement with those obtained by Driscoll’s 8-hydroxyquinoline extraction-ion exchange method.  相似文献   

18.
This is the first report of the determination of aniline with tetra-substituted amino aluminium phthalocyanine (TAAlPc) by a fluorimetric method. In KBr-HCl solution, nitrite ion diazotizes TAAlPc, thus, the fluorescence of TAAlPc is dramatically quenched. However, there is less quenching in the presence of aniline and the recovery in fluorescence intensity is linear with the concentration of aniline. Based on this, a novel method has been developed for the determination of aniline in aqueous solutions. Under the optimal conditions, the calibration graph for aniline is from 5 to 300 ng ml−1 with a 3σ limit of detection of 1.8 ng ml−1. The relative standard deviation for nine replicate measurements of 100 ng ml−1 aniline is 1.7%. The method was applied to the analysis of water samples with satisfactory results.  相似文献   

19.
A first order derivative spectrophotometric method has been developed for the simultaneous determination of bismuth and zinc by dithizone without time-consuming extraction step. The reactions of bismuth and zinc with dithizone in a three component solution prepared in water, acetone and n-propanol mixture have been investigated. These cations react with dithizone in this mixture at pH 5.0, forming coloured complex that is stable for at least 2 h. The linear range in D evaluation was between 3.0 × 10−6 and 1.8 × 10−5 mol l−1 for Zn and 2.4 × 10−6 and 1.2 × 10−5 mol l−1 for Bi. The limits of detection for the analytical procedure were found 0.05 mg l−1 for both cations. The relative standard deviations for the determination of 0.5 mg l−1 bismuth and 0.5 mg l−1 zinc were 1.2 and 1.1%, respectively, for five determinations. The procedure is simple, rapid and reliable. This method was applied to the determination of bismuth and zinc in the pharmaceutical materials successfully. Good agreement was achieved between the results obtained by the proposed and comparative methods.  相似文献   

20.
Yang XF  Li H 《Talanta》2004,64(2):478-483
A novel flow-injection chemiluminescence (CL) method for the determination of dihydralazine sulfate (DHZS) is described. The method is based on the reaction between DHZS and hexacyanoferrate(III) in alkaline solution to give weak CL signal, which is dramatically enhanced by eosin Y. The CL emission allows quantitation of DHZS concentration in the range 0.02-2.8 μg ml−1 with a detection limit (3σ) of 0.012 μg ml−1. The experimental conditions for the CL reaction are optimized and the possible reaction mechanism is discussed. The method has been applied to the determination of DHZS in pharmaceutical preparations and compared well with the high performance liquid chromatography (HPLC) method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号