首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到16条相似文献,搜索用时 15 毫秒
1.
This study examined standard solutions to assess the influence of the gas flow rate and organic solvent type on losses caused by gas blowdown of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/DFs) and coplanar polychlorinated biphenyls (Co-PCBs). Results obtained here will contribute to maintaining analytical method performance and system quality for PCDD/DFs and Co-PCBs analyses. An organic solvent (with 0.5 ml each of acetone, dichloromethane, n-hexane, and toluene), PCDD/DFs or Co-PCBs, and their 13C12-labeled compounds were put separately into 10 ml pear-shaped flasks. The samples were blown to dryness at room temperature until the last trace of solvent disappeared. They were subsequently reconstituted in those flasks. Analyte recoveries were calculated by comparing blown samples to those that had not been blown. Recoveries of Co-PCBs were more affected than those of PCDD/DFs when the gas flow rates were set at 203, 261, 332, and 456 ml/min. Losses of Co-PCBs were least at 203-332 ml/min. Regarding losses of PCDD/DFs and Co-PCBs, the toluene solution showed the least variation in recovery. An actual soil sample extract was also examined using optimized conditions for the gas flow rate and solvent types obtained by experiments in standard solutions. Thereby, the blowdown conditions gave quantitative recoveries of 13C12-labeled compounds in the sample extract.  相似文献   

2.
A solid-phase extraction (SPE) method was optimized for accurate determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and coplanar polychlorinated biphenyls (CoPCBs) in humic acid containing surface water. Recovery experiments using humic materials revealed that humic acids permit dioxins to pass through an octadecylsilica (C18) extraction disk by associating with them under weakly alkaline conditions. Acidification of the sample before percolation improved this otherwise insufficient recovery. The analysis of surface water acidified to pH 2 gave better recovery with surrogate standards and lower quantitative values for higher-chlorinated homologues than the sample at pH 9. In all samples, the native octachlorodibenzo-p-dioxin (OCDD) peak abundance showed no difference between at pH 2 and at pH 9, indicating overestimation of the quantitative value of the homologue at pH 9. Acidification of a humic acid containing water sample can avoid overestimation of higher-chlorinated congeners caused by insufficient recovery of their corresponding surrogates.  相似文献   

3.
This paper reports on the optimisation, characterisation, validation and applicability of gas chromatography coupled to triple quadrupole mass spectrometry in its tandem operation mode (GC-QqQ(MS/MS) for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs, dioxins) and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food matrices. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for the analysis of this type of compounds and samples. Good repeatability for areas (RSD = 1–10%, for PCDD/Fs and DL-PCBs) and for ion transition ratios (RSD = 0.3–10%, for PCDD/Fs, and 0.2–15%, for DL-PCBs) and low instrumental limits of detection, 0.07–0.75 pg μL−1 (for dioxins) and 0.05–0.63 pg μL−1 (for DL-PCBs), were obtained. A comparative study of the congener specific determination using both GC-QqQ(MS/MS) and gas chromatography-high resolution mass spectrometry (GC-HRMS) was also performed by analysing several fortified samples and certified reference materials (CRMs) with low (feed and foodstuffs), median (sewage sludge) and high (fly ash) toxic equivalency (TEQ) concentration levels, i.e. 0.60, 1.83, 72.9 and 3609 pg WHO-TEQ(PCDD/Fs) g−1. The agreement between the results obtained for the total TEQs (dioxins) on GC-QqQ(MS/MS) and GC-HRMS in all the investigated samples were within the range of ±4%, and that of DL-PCBs at concentration levels of 0.84 pg WHO-TEQs (DL-PCBs) g−1, in the case of feedstuffs, was 0.11%. Both instrumental methods have similar and comparable linearity, precision and accuracy. The GC-QqQ(MS/MS) sensitivity, lower than that of GC-HRMS, is good enough (iLODs in the down to low pg levels) to detect the normal concentrations of these compounds in food and environmental samples. These results make GC-QqQ(MS/MS) suitable for the quantitative analysis of dioxins and DL-PCBs and a real alternative tool to the reference sector HRMS instruments.  相似文献   

4.
《Analytica chimica acta》2002,470(2):205-214
A new analytical method based on the cloud-point extraction (CPE) methodology combined with high-performance liquid chromatography is used in this study for the extraction and quantification of polychlorinated dibenzo-p-dioxins. These compounds are extracted by using the non-ionic surfactant polyoxyethylene 10 lauryl ether (POLE) from different aqueous systems: fresh, brackish and sea waters. After the cloud-point extraction, which also allowed a preconcentration of the PCDDs being studied, the samples were analysed using a HPLC-UV system under the optimum chromatographic conditions. The proposed method showed very satisfactory recovery percentages for the PCDDs under study and standard deviation values lower than 2%.The results obtained were finally compared with those found using the traditional liquid-liquid extraction method.  相似文献   

5.
Freezing-lipid filtration as a new method has been developed for the rapid determination of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/Fs) in biological samples. This method can effectively reduce the time of sample pretreatment, labor and amount of solvents compared with conventional methods. By freezing-lipid filtration procedure, about 90% of lipids in extract could be removed without any significant loss of PCDD/Fs. For further cleanup of extracts after freezing-lipid filtration, automatic parallel LC columns including silica gel, alumina and carbon columns were applied. During automatic parallel LC columns cleanup, most of co-extracted interferences such as residue lipids and fatty acids could be eliminated and dioxins could be separated from many other dioxin-like congeners such as polychlorinated biphenyls by this procedure. The extracts after cleanup were analyzed by high-resolution gas chromatography (HRGC)/high-resolution mass spectrometry (HRMS) using an isotope dilution method. The average recoveries and relative standard deviation (R.S.D.) of 17 native congeners in the spiked fish samples at 8-80 pg/g (n = 3) were ranged between 85.3 and 117.2% and 5.7-20.3%, respectively.  相似文献   

6.
A fast clean-up procedure for the low level analysis of polychlorinated dibenzo-p-dioxins. polychlorinated dibenzofurans and coplanar polychlorinated biphenyls in highly fatty biological matrices using high capacity disposable multi-layer silica columns is presented. Results were compared with gel permeation chromatography for removal of lipids. Analytical criteria such as recovery rates, repeatability, reproducibility and robustness are evaluated through a broad range of biological matrices and reference materials analysis. The final proposed procedure for the complete analysis, including pressurized liquid extraction, Power-Prep system clean-up and GC-high-resolution MS analysis requires only 48 h, and allows the simultaneous preparation of up to 10 samples.  相似文献   

7.
Analytical techniques for the determination of polychorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF) and dioxin-like PCBs (DLPCB) are reviewed. The focus of the review is on recent advances in methodology and analytical procedures. The paper also reviews toxicology, the development of toxic equivalent factors (TEF) and the determination of toxic equivalent quantity (TEQ) values. Sources, occurrence and temporal trends of PCDD/PCDF are summarized to provide examples of levels and concentration ranges for the methods and techniques reviewed.  相似文献   

8.
Method validation was performed on the collection and extraction procedures for an analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DLPCBs) in flue gas. The adoption of the rapid pressurized liquid extraction (PLE) technique was evaluated for extraction from polyurethane foam plugs (PUFPs) and fly ash. With respect to extraction from PUFPs, dichloromethane PLE showed an extraction efficiency equivalent to that of conventional acetone Soxhlet, while toluene PLE was found to have a lower extraction efficiency from fly ash than toluene Soxhlet. The collection ability of three sampling methods, employed in the Japanese standard analytical method JIS K0311 (revised in 2005) was evaluated by evaluating the distribution of gaseous PCDD/Fs and DLPCBs in each collection compartment in sampling trains. A DiOANA® fibrous alumina filter and a PUFP, newly employed trapping devices in the revised JIS method, were found to trap gaseous analytes effectively. The validation of the two newly employed sampling methods (DiOANA and PUFP) was tested by parallel measurements of the methods with a conventional five-impinger method, and good agreements on the PCDD/Fs and DLPCBs quantities were demonstrated.  相似文献   

9.
Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry (GC/MPI/TOF-MS) was applied to the trace analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). To determine the optimum wavelength for analysis of PCDD/Fs, the wavelength of the femtosecond laser utilized for multiphoton ionization was converted to near-ultraviolet status using stimulated Raman scattering. A femtosecond laser emitting at 300 nm completely eliminated the background signal arising from the bleeding compounds generated from a stationary phase of the capillary column in GC.  相似文献   

10.
Comprehensive Gas Chromatography-Time-of-Flight Mass Spectrometry (GC×GC-TOFMS) methodology has been refined for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in samples with different matrices. This is specifically for application in developing countries where access to gas chromatography-high resolution mass spectrometry (GC-HRMS) and highly skilled personnel is limited. The method, using an Rxi-5 Sil MS column in the first dimension ((1)D) coupled with an Rtx-200 column in the second dimension ((2)D), was used to quantify PCDDs and PCDFs in different environmental sample matrices. The results were compared with those obtained using GC-HRMS and good agreement was observed. The limit of detection (LOD) for the method (300fg on column for spiked soil samples) was determined using an Rxi-XLB ((1)D) column coupled with an Rtx-200 column ((2)D). Preliminary South African sample results are also discussed. Isomer specificity for different tetrachloro dibenzo-p-dioxins (TCDDs) and tetrachloro dibenzofurans (TCDFs) was investigated using a commercial standard. Adequate resolution was achieved. The method as described has great attraction for developing countries being both financially and operationally favourable.  相似文献   

11.
This paper describes fast and simple extraction methods for the determination of polychlorinated biphenyls and polybrominated diphenyl ethers in biological matrices. Four extraction protocols were tested. The first protocol used microwave-assisted extraction combined with two purification steps. The second one was similar, except that microwave-assisted extraction was replaced by accelerated solvent extraction. The third one combined extraction/purification by accelerated solvent extraction with final purification on a silica gel column. The last one combined microwave-assisted extraction with purification on an acidic silica gel column. The protocols were tested on various matrices: a spiked matrix, two certified matrices (SRM 2977, WMF 01), and natural matrices (mysids and fish). All of the protocols produced good performance in terms of recovery and reproducibility. The two last protocols showed promising results in terms of applicability to natural matrices, as they required a minimum of sample handling and minimal amounts of solvent and time. These methods allowed at least 24 samples to be handled per day, and could easily be used for routine analysis. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

12.
Dongli Wang  Zongwei Cai 《Talanta》2007,72(2):668-674
A column chromatography procedure was developed for the clean-up of solvent-extracted sediment samples for the fractionation of polybrominated diphenyl ethers (PBDEs) and polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs). The procedure included multiple column chromatography steps for clean-up for the separation of PBDEs from PBDD/Fs. The separation of the two chemical groups overcame the mutual interfering problem during the GC-ion trap MS analysis. The method was validated with the analysis of quality control samples. The method accuracy represented with relative error was less than 16% for all targeted PBDEs and PBDD/Fs congeners. Recoveries of the 13C-labeled standards ranged from 64% to 117% with relative standard deviation from 7.3% to 15%. Results from the analysis of environmental sediment samples collected in the vicinity of a recycling site for electronic wastes showed high levels of PBDEs (1.5-12 ng/g, dry weight), trace levels of PBDFs (0.025-0.92 ng/g, dry weight) and non-detectable PBDDs.  相似文献   

13.
The usual methods for determining polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF) and polychlorinated biphenyls (PCB) are generally expensive and time consuming. This fact has favored the development of faster and cheaper techniques, based on immunoassays and bioassays. This paper reviews these bioanalytical methods and their analytical importance at the present moment.  相似文献   

14.
A method was developed for analysis of PCDD/Fs in fly ash and soil samples by using the combination of pressurized liquid extraction (PLE) and off-line HPLC fractionation with a porous graphite carbon (PGC) column, followed by analysis using HRGC/HRMS. The samples were automatically extracted by PLE. A multi-layer silica column was used for the preliminary cleanup. Then off-line fractionation was applied for the separation of PCDD/Fs and the collected PCDD/Fs fraction was analyzed by HRGC/HRMS. The use of solvent back-flushing at 70°C successfully solved the carry-over problem of PGC column. The procedure of single extraction and cleanup provided advantages of high automation and significant reduction of solvent and time compared to conventional methods. The method was validated by certified materials of fly ash and industrial sandy soil, and applied for the analysis of fly ash samples collected from three two-ton medical waste incinerators in Beijing and one farm soil sample collected in the vicinity of the incinerators.  相似文献   

15.
Two polychlorinated biphenyls (PCB) enzyme linked immunosorbent assays (ELISAs) were developed using goat PCB purified immunoglobulin (IgG) antibodies (Abs). The IgGs exhibited the highest affinity toward PCB-77 (24 ng mL−1) with sensitivities in the range of 6-11 ng mL−1. The Abs cross-reacted with PCB-126 and the heptachlorodibenzofuran 1,2,3,4,6,7,8-HpCDF but not with PCB-169, PCB-118, Aroclor 1232, 1248, 1260 or the hexachlorodibenzofuran 2,3,4,6,7,8-HxCDF. The IgGs were also used to develop a sol-gel-based immunoaffinity purification (IAP) method for cleanup of PCB-126. Recovery efficiencies depended on the sol-gel formats; a 1:12 format resulted in the highest binding capacity. Net binding capacity ranged from 112 to 257 ng, and 90% of the analyte could be eluted with only 2 mL of ethanol. The method was also very efficient in purifying PCB-126 from spiked soil and sediment samples from contaminated sites; and eliminating matrix interferences to a degree that enabled analysis of the purified samples by ELISA. The approaches developed in the course of the study form a basis for the development of additional IAP methods for other PCBs, and their implementation in high-throughput screening programs for PCB in food, soil, and other environmental and biological samples.  相似文献   

16.
A new cleanup method was developed and validated for the determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in sediment. The sample extract was first treated with sulfuric acid and then cleaned up by a large volume injection gas chromatography online coupled with liquid chromatography (LVI-GC-LC) system. PCDD/Fs in the extract were separated by a GC column (DB-5), selected cut, cool trapped and transferred to a LC column (alumina). The fraction of PCDD/Fs eluted from the alumina column was collected and concentrated for the instrumental analysis. Under the optimized conditions, LVI-GC-LC method achieved the recoveries of 57–102% for 2,3,7,8-substituted PCDD/Fs, which met the requirements of US Environmental Protection Agency (EPA) Method 1613 and were better than those obtained using the conventional multistep column cleanup method. Meanwhile, compared with the conventional method, the limit of detection (LOD) values of 2,3,7,8-substituted PCDD/Fs cleaned up by LVI-GC-LC method were decreased due to the high-efficiency removal of interferents. These results suggested that the LVI-GC-LC cleanup method was a promising alternative to the multistep cleanup procedure for the determination of dioxins in environmental samples.  相似文献   