首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
The accreditation of testing and calibration laboratories to ISO/IEC 17025 is increasingly calling for the accreditation of reference material (RM) producers. Two international guides, ISO Guide 34 (2000) " General requirements for the competence of reference material producers" issued by the ISO Committee on Reference Materials and ILAC-G 12 " Guidelines for the requirements for the competence of reference material producers" issued by the International Laboratory Accreditation Cooperation (ILAC), are already in use for this purpose. Recently however initiatives have been launched to accredit RM producers to ISO 17025 as calibration laboratories and it has been suggested that a combination of ISO/IEC 17025 " General requirements for the competence of testing and calibration laboratories" and ISO Guide 34 may be the best option. This publication is an expression of the position of the ISO Committee on Reference Materials (ISO/REMCO) on the standards and guides currently in use in the accreditation of RM producers. The paper discusses the advantages and disadvantages of these standards and guides from the perspective of benefit to RM producers and RM users. In conclusion, the use of ISO Guide 34 alone or in combination with ILAC-G 12 is the preferred system for the accreditation of RM producers. Therefore ISO/REMCO strongly encourages all accreditation bodies to adopt ISO Guide 34.  相似文献   

2.
This study simulated the transport and storage conditions of ethanol in water certified reference material (CRM) produced by the Chemical Metrology Division of Inmetro—DQUIM with the purpose of estimating the measurement uncertainty related to stability. The short-term stability study was performed on five different mass fractions (w) in terms of mg ethanol/g solution of the ethanol in water CRM. The nominal values are w = 0.5, 0.9, 1.1, 3.8 and 4.6 mg/g, at temperatures of 4 and 60 °C. On the other hand, the long-term stability study was developed on four different mass fractions (nominal values): w = 0.5, 0.9, 1.1 and 4.6 mg/g, at a temperature of 20 °C. This paper will show the data from the long-term stability study that took place over 52 weeks. The method used complies with ISO Guide 35, the BCR Guideline for Feasibility Studies and ISO Guide 34. According to the statistical parameters used in both studies, the stability of ethanol in water CRM was confirmed for all of the mass fractions studied.  相似文献   

3.
4.
 Research and development activities are carried out by various types of laboratories that are not the typical testing and calibration laboratories for which the ISO/IEC 17025 is the quality assurance implementation reference. In this paper, such laboratories engaged in R&D activities are classified and different approaches they can adopt with a view to implementing a quality system that are suited to their characteristics and the type of work they conduct are proposed. These approaches take account of existing standards for the certification/accreditation of laboratories and of guides on quality assurance for non-routine analytical laboratories. Received: 11 July 2002 Accepted: 29 November 2002 Presented at Analytica Conference, 23–26 April 2002, Munich, Germany Correspondence to M. Valcárcel  相似文献   

5.
 An analytical result is not considered to be complete without a statement of the measurement uncertainty associated with it. Evaluation of measurement uncertainty is therefore an essential part of every determination. In the present study the measurement uncertainty of the result of determination of selenium in the reference material Seronorm Trace Elements Serum was studied. The combination of a digestion procedure using sulfuric acid, V2O5 in H2SO4 and hydrogen peroxide and the continuous flow approach of hydride generation atomic fluorescence spectrometry (HG-AFS) detection was used for selenium determination. The total uncertainty budget was calculated with the help of the GUM Workbench program, in which computations follow the rules of the ’ISO guide to the expression of uncertainty in measurement’. The major sources of uncertainty were found to be due to the recovery of the procedure, measurement of peak heights and the purity of Na2SeO3. A selenium mass fraction of 77.1±4.8 ng/g (with a coverage factor of 2.1, 95% probability) was determined, which is comparable with the recommended value of 80 ng/g. Received: 13 September 2002 Accepted: 23 December 2002 Acknowledgements We would like to thank Tinkara Buˇcar, B.Sc. for useful discussions and the IAEA Vienna, for financial support of the project 11553/RO. Presented at CERMM-3, Central European Reference Materials and Measurements Conference: The function of reference materials in the measurement process, May 30–June 1, 2002, Rogaška Slatina, Slovenia Correspondence to V. Stibilj  相似文献   

6.
This topic is being presented from two perspectives, namely the views of an accreditation body and those of an accredited provider of external quality assessment schemes. The first perspective, from an accreditation body, is based on the experience of Australia's national laboratory accreditation body (NATA), which has accredited fourteen proficiency testing (PT) providers and is currently processing an application from another. The second perspective is based on the experience of EQUALIS, the national quality assurance organisation for laboratory medicine in Sweden, which was granted accreditation in 2002.Presented at 5th Eurachem Workshop on Proficiency testing in analytical chemistry, microbiology and laboratory medicine, Portorož (Slovenia) 25–27 Sept 2005  相似文献   

7.
  ISO 9000 series strictly requires traceability to national or international measurement standards. It is becoming more necessary to make clear the concept of traceability of measurement standards with respect to chemical composition and to accredit the reference material producers. In Japan, the accreditation system for reference material producers is considered to satisfy the requirement of ISO Guide 34, ISO 9000 series and ISO/IEC Guide 25, while the producer fulfills the concept of traceability of measurement standards. This paper describes the production of iron and steel reference materials in Japan relating to the international standardization of methods (written standards) and accreditation of reference material producers. Received: 11 October 1996 Accepted: 5 December 1996  相似文献   

8.
The Chemical Section of the National Office of Measures, Hungary (OMH) [1] embarked on the preparation of a wheat sample series as a Certified Reference Material [2] (CRM) in 1992. The practical implementation of the wheat sample series has shown that test- ing laboratories are in great need of easy-to-use flour reference samples to objectively and independently qualify wheat. To fill this need, we have developed a three-term flour reference sample series. The certification process was car-ried out according to ISO recommendations. Investigations of the long-term stability [3] and the application of wheat and flour CRMs are continuing. Wheat is one of the most widely grown crops in Hun- gary and it is one of the major determinative factors in the economy. Its uniform and objective qualification is of outstanding importance. There are well-equipped laborato-ries with sufficient experience to assess wheat flour quality, howev- er, proficiency testing has shown that certified samples need to be used to achieve exact and uniform measuring results. Received: 12 November 1999 Accepted: 16 August 2000  相似文献   

9.
The 2-year international joint project HYCREF (Contract-No. G6RD-CT-2002-00854), funded by the European Commission in the 5th Framework programme, aimed to develop methods to prepare homogenous and stable water-, soil- and waste reference materials contaminated with mineral oil hydrocarbons and to test certify the mineral oil content by gas chromatographic methods. As mineral oil products are important sources for environmental contaminations, appropriate reference materials certified by using the new gas chromatographic methods (soil: ISO/FDIS 16703, waste: prEN 14039 and KW/04, water: ISO 9377-2) are highly needed. Additional to the HYCREF-results presented in part I–mineral contaminated soils–this second paper gives an overview of the feasibility study for the preparation and test certification of three waste reference materials (offshore marine sediment, building material and industrial waste). The following specifications, which had been defined in the project work plan, were reached successfully: uncertainty of the mineral oil content resulting from the certification exercise ≤5% and a between-bottle inhomogeneity of ≤3%. All three materials have been evaluated for long- and short term stability. They contain different levels and types of mineral oil and cover the full application range of ISO/FDIS 16703 and prEN 14039 (100–10,000 mg/kg). The expanded uncertainties U cert of the three materials are about 6%. In this way, they are comparable to ERM®-CC015a (U cert=7.1%, mineral oil in a river sediment) and are suited to close the present gap of commercially available CRM for mineral oil determination in waste.  相似文献   

10.
In the view of the Deutscher Kalibrierdienst (DKD) , a certifying body for reference materials can be considered to be a calibration laboratory. Therefore, accreditation of calibration laboratories in accordance with ISO/IEC 17025 is the most appropriate way to establish confidence in certificates for reference materials. If necessary, the criteria of ISO/IEC 17025 can be tailored to specific cases. There is no need to provide any new kind of reference-material specific accreditation. However, in view of the variety of reference materials and the practice existing in other countries, accreditation of testing laboratories and product certification bodies may optionally be acceptable as long as the same stringent principles with respect to traceability and measurement uncertainty are applied. Such accreditations but not accreditations of reference material producers (ISO Guide 34) are also covered by existing international mutual recognition arrangements (MRA).  相似文献   

11.
This paper presents the preparation of a candidate certified reference material (CRM) of cypermethrin in green tea, GLHK-11-01a according to the requirements of ISO Guide 34 and 35. Certification of the material was performed using a newly developed isotope dilution mass spectrometry (IDMS) approach, with gas chromatography high resolution mass spectrometry (GC–HRMS) and gas chromatography–tandem mass spectrometry (GC–MS/MS). Statistical analysis (one-way ANOVA) showed excellent agreement of the analytical data sets generated from the two mass spectrometric detections. The characterization methods have also been satisfactorily applied in an Asia-Pacific Metrology Program (APMP) interlaboratory comparison study. Both the GC–HRIDMS and GC–IDMS/MS methods proved to be sufficiently reliable and accurate for certification purpose. The certified value of cypermethrin in dry mass fraction was 148 μg kg−1 and the associated expanded uncertainty was 14 μg kg−1. The uncertainty budget was evaluated from sample in homogeneity, long-term and short-term stability and variability in the characterization procedure. GLHK-11-01a is primarily developed to support the local and wider testing community on need basis in quality assurance work and in seeking accreditation.  相似文献   

12.
The first experiences of implementing of ISO/IEC 17025 have been obtained by the accreditation bodies and laboratories following the standard, and a workshop to discuss the experiences was arranged. This presentation gives the conclusions and recommendations from the workshop based on the lectures and discussions. In general, the adoption of ISO/IEC 17025 has been a smooth process. Received: 28 February 2002 Accepted: 2 March 2002  相似文献   

13.
 The principles of the ISO "Guide to the expression of uncertainty in measurement" are applied to the analysis of solid materials by graphite furnace atomic absorption spectrometry. Assessment of trueness is achieved by the analysis of a certified reference material (CRM) under fixed instrumental conditions. For the evaluation of the method's uncertainty (as part of the validation) a model equation is derived, considering all significant contributions, including the uncertainty in the CRM value and the uncertainty in the CRM analysis. A concrete example is presented and discussed (soya flour as an unknown sample and CRM BCR rye grass). For routine analysis a pooled estimate from the validation experiment can be used, leading to an acceptable small uncertainty range even in the case of "duplicate determination". The test for trueness (acceptance) of the result of the CRM analysis is applied and the correction for detected bias is discussed. Received: 28 June 1998 · Accepted: 13 July 1998  相似文献   

14.
This paper summarises the experience we gained while going through an accreditation process in accordance with the requirements of ISO/IEC 17025 Standard. We propose in this paper an initial path finding study stage to evaluate the laboratory's predisposition for, and the benefits of, accreditation. We also present a conceptual framework as part of the path finding study stage to identify and classify different groups of activities in a laboratory into separate business domains. The objective of the study is to assess, for each business domain, the approach, the benefits, costs and implications of working with a systematic QA and then design a priori appropriate working systems tailored to the real needs of each business. Such a study should naturally lead to an appropriate definition of accreditation scope.
Elke AnklamEmail: Phone: +32 14 571 316Fax: +32 14 571 783
  相似文献   

15.
In the mid 1990s, the National Physical Laboratory (NPL) took the decision to seek external accreditation to the then UK national accreditation standard (M10, M10 supplement and M11) through the NPL’s National Measurement Accreditation Service (NAMAS). This paper details the reasoning behind that initial decision and, in particular, how this impinged on the day-to-day activities of the NPL’s Radioactivity Metrology Group (RMG). In the intervening decade, the accreditation standard has changed considerably; accreditation is now to the international standards ISO 9001:2000 (Quality Management Systems: Requirements) and ISO 17025:2005 (General Requirements for the Competence of Testing and Calibration Laboratories); accreditation is now carried out by a wholly separate successor organization to NAMAS, the United Kingdom Accreditation Service (UKAS). To meet the new accreditation requirements the RMG: realigned it’s scope of work; streamlined and consolidated written procedures, references and appendices; centralized the collection of written procedures, and clarified the document identification system. Future developments will include efforts for RMG accreditation for conducting proficiency tests and providing reference materials.  相似文献   

16.
 This paper describes a real accreditation case from VTT Chemical Technology in Finland. The laboratory has acquired accreditation according to ISO/IEC Guide 25 and EN 45001 for a variety of organic and inorganic environmental tests. The present paper summarizes the reasons for applying for accreditation and selecting the test methods, gives the costs involved, and describes some future developments and views. Also, some details of laboratory intercomparisons and quality system structures are briefly reported.  相似文献   

17.
Hospital laboratories have error rates that are too high and in some cases may be responsible for adverse patient treatment. This paper introduces reliability growth management (RGM), which is based on learning curve theory, as a method to improve laboratory error rates. RGM is widely used in the defense and automotive industry to solve problems when resources are limited and knowledge about the product and/or process is incomplete. An example of RGM, which was used to improve the reliability of instrument assay systems in the medical diagnostics industry is presented. RGM is a closed-loop process that entails creating a goal and event model, classifying events with failure review and corrective action system (FRACAS), tracking progress and predicting completion with Duane analysis. Results achieved by RGM were far better than those obtained by previously used methods. RGM techniques can be transferred to hospital laboratories to reduce laboratory error rates. The advantages of RGM compared to other quality initiatives such as ISO 9000 and Six Sigma are discussed. Received: 3 February 2002 Accepted: 17 July 2002 Acknowledgements The majority of the work of transferring reliability growth management from the defense industry to the medical device industry was performed by Keith K. McLain, while he was at Ciba Corning Diagnostics. Keith is now at Ortho-Clinical Diagnostics (email: KMcLain@ocdus.jnj.com). Presented at the European Conference on Quality in the Spotlight in Medical Laboratories, 7–9 October 2001, Antwerp, Belgium Abbreviations  RGM Reliability growth management · FRACAS failure review and corrective action system · CAP College of American Pathologists · LIS laboratory information system · HIS hospital information system Correspondence to Jan Krouwer  相似文献   

18.
 The establishment of a reference examination system necessary for metrological traceability of the many types of sophisticated examination result in laboratory medicine is a daunting task, which has been made mandatory by the EU Directive on in vitro diagnostic medical devices and the requirements for accreditation. Following a definition of examinand and allowed examination uncertainty, a dedicated calibration hierarchy is established from stated reference through alternating reference examination procedures and calibrators providing a traceability chain from examination result to the reference, often a definition of a measurement unit. The various types of possible calibration hierarchy are outlined in EN ISO Standards. Recent efforts by national and international stakeholders to establish a global reference examination system have led to the creation of a Joint Committee on Traceability in Laboratory Medicine with the International Committee for Weights and Measures, International Bureau of Weights and Measures, International Federation of Clinical Chemistry and Laboratory Medicine, International Laboratory Accreditation Cooperation, and World Health Organization as the principal promoters. This structure will identify reference procedures, reference materials, and reference laboratories, and seek support for further prioritised and coordinated development of the system. Received: 1 August 2002 Accepted: 22 November 2002 Based on a lecture at an IUPAC Seminar, EC JRC Institute for Reference Materials and Measurements, Geel, BE, 2001–12–18 Correspondence to R. Dybkaer  相似文献   

19.
 A preliminary batch of the reference material was prepared by freeze-drying pooled urine samples obtained from healthy persons occupationally exposed to styrene. Tests for homogeneity and stability were performed by determining urine concentrations of mandelic (MA) and phenylglyoxylic acids (PGA). The urinary MA and PGA concentrations were followed over an 8-month period using high performance liquid chromatography (HPLC). No changes of the concentration values were found. Pure PA and PGA from Merck and Fluka, respectively, were used for traceability purposes, because certified or standard reference materials for MA and PGA do not exist. Control material ClinChek-Urine Control (Recipe) was analysed simultaneously. The mean values of MA and PGA compared well with the means of control samples and fell within the control range. The certified values and their uncertainties were evaluated from the results of interlaboratory comparisons, homogeneity (277.0 ± 7.4 mg L−1 for MA and 148.0 ± 4.7 mg L−1 for FGA) and stability tests. The values are unweighted arithmetical averages of accepted results and their uncertainties are combined uncertainties enlarged by coefficient k=1, evaluated from the standard uncertainties of the interlaboratory comparison, homogeneity and stability tests. Received: 17 September 2002 Accepted: 1 November 2002 Acknowledgement This work was supported by the Internal Grant Agency of Ministry of Health of the Czech Republic (Grant NJ/6784–3). Presented at CERMM-3, Central European Reference Materials and Measurements Conference: The function of reference materials in the measurement process, May 30–June 1, 2002, Rogaška Slatina, Slovenia Correspondence to I. Šperlingová  相似文献   

20.
The reliability of analytical data is very important to forensic and clinical toxicologists for the correct interpretation of toxicological findings. This makes (bio)analytical method validation an integral part of quality management and accreditation in analytical toxicology. Therefore, consensus should be reached in this field on the kind and extent of validation experiments as well as on acceptance criteria for validation parameters. In this review, the most important papers published on this topic since 1991 have been reviewed. Terminology, theoretical and practical aspects as well as implications for forensic and clinical toxicology of the following validation parameters are discussed: selectivity (specificity), calibration model (linearity), accuracy, precision, limits, stability, recovery and ruggedness (robustness). Received: 16 June 2002 Accepted: 12 July 2002 Part of this review was published in the communications of the International Association of Forensic Toxicologists (TIAFT; TIAFT Bulletin 32 (2002): 16–23) and of the Society for Forensic and Toxicologic Chemistry (GTFCH; Toxichem and Krimitech 68 (2001): 116-126). Correspondence to F. T. Peters  相似文献   