首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The implementation of columns packed with sub-2 μm particles in supercritical fluid chromatography (SFC) is described using neat carbon dioxide as the mobile phase. A conventional supercritical fluid chromatograph was slightly modified to reduce extra column band broadening. Performances of a column packed with 1.8 μm C18-bonded silica particles in SFC using neat carbon dioxide as the mobile phase were compared with results obtained in ultra high performance liquid chromatography (UHPLC) using a dedicated chromatograph. As expected and usual in SFC, higher linear velocities than in UHPLC must be applied in order to reach optimal efficiency owing to higher diffusion coefficient of solutes in the mobile phase; similar numbers of theoretical plates were obtained with both techniques. Very fast separations of hydrocarbons are presented using two different alkyl-bonded silica columns.  相似文献   

2.
N. Wu  Q. Tang  Y. Shen  M. L. Lee 《Chromatographia》1999,49(7-8):431-435
Summary In this paper, practical considerations of column efficiency, separation speed, thermal stability, and column polarity of capillary columns packed with polybutadiene-coated zirconia were investigated under solvating gas chromatography (SGC) conditions using carbon dioxide as mobile phase. When compared with results obtained from conventional porous octadecyl obtained from conventional porous octadecyl bonded silica (ODS) particles, PBD-zirconia particles produced greater change in mobile phase linear velocity with pressure than conventional ODS particles under the same conditions. The maximum plate number per second (Nt) obtained with a 30 cm PBD-zirconia column was approximately 1.5 times higher than that obtained with an ODS column at 100 °C. Therefore, the PBD-zirconia phase is more suitable for fast separations than conventional ODS particles in SGC. Maximum plate numbers per meter of 76,900 and 63,300 were obtained using a 57 cm×250 μm i.d. fused silica capillary column packed with 3 μm PBD-zirconia at 50 °C and 100 °C, respectively. The PBD-zirconia phase was stable at temperatures up to 320 °C under SGC conditions using carbon dioxide as mobile phase. Polarizable aromatic compounds and low molecular weight ketones and aldehydes were eluted with symmetrical peaks from a 10 cm column packed with 3 μm PBD-zirconia. Zirconia phases with greater inertness are required for the analysis of more polar compounds by SGC.  相似文献   

3.
Summary The dependence of the capacity factor of polycyclic aromatic hydrocarbons on column temperature and on the density of the mobile phase in supercritical-fluid chromatography was investigated using carbon dioxide as the mobile phase. Logarithmic capacity factors of polycyclic aromatic hydrocarbons were obtained as a linear function of the reciprocal column temperature at a constant molar volume of carbon dioxide.The application of the Retention Prediction System to supercritical-fluid chromatography is demonstrated: one can predict the retention of polycyclic aromatic hydrocarbons using equations including column temperature, density and the physico-chemical properties of the solutes as the parameters.  相似文献   

4.
A direct sample injection technique was developed for supercritical fluid chromatography in a packed capillary column, with carbon dioxide as mobile phase and a flame ionization detector. The method allowed solutions, neat liquids, and even solids to be introduced as samples. Also, extraction with supercritical carbon dioxide was combined with this method to separate polymer additives.  相似文献   

5.
The influence of pressure drop on retention, selectivity, plate height and resolution was investigated systematically in packed supercritical fluid chromatography (SFC) using pure carbon dioxide as the mobile phase. Numerical methods developed previously which enabled the prediction of pressure gradients, diffusivities, capacity factors, plate heights and resolutions along the length of the column were used for the model calculations. The effects of inlet pressure and supercritical fluid flow rate on selectivity and resolution are studied. In packed column SFC with pure carbon dioxide as the mobile phase, the pressure drop can have a significant effect on resolution. The flow rate is shown to have a larger effect than generally realized. The calculated data are shown to be in good agreement with the experimental results. Finally, the variation of the chromatographic parameters along a 5.5 meter long model SFC column is illustrated. The possibilities and limitations of using long packed columns in SFC are discussed. It is demonstrated that long columns with large plate numbers do not necessarily yield better separations.  相似文献   

6.
A study was carried out in which 50 microm I.D. fused-silica capillaries were packed with 3 microm octadecylsilane bonded silica, from the same batch, by four methods; liquid slurry and carbon dioxide supercritical carrier, each with and without the use of an ultrasonic probe. A neutral test mixture was analysed by capillary column in reversed-phase mode, and the reproducibility of the electroosmotic flow and of migration time, column efficiency and retention factors, was determined. Initially results suggested that there was no significant difference between properties of columns packed by different methods, and a more thorough statistical evaluation confirmed this; differences observed in the column performance were attributed to random variations between replicate columns, and not between packing methods. However, the variation was least when applying the ultrasonication during liquid slurry.  相似文献   

7.
N. Wu  R. Yee  M. L. Lee 《Chromatographia》2000,53(3-4):197-200
Summary Fast separations of perfluorinated polyethers and polymethylsiloxanes that are composed of 50–80 oligomers were demonstrated in packed capillary column supercritical fluid chromatography (SFC) using a carbon dioxide mobile phase. Separations were accomplished within 10 min using a 13 cm×250 μm i.d. column packed with 2 μm porous octadecyl bonded silica (ODS) particles. Effects of particle diameter of the packing material and pressure programming on separation were investigated, and packed column SFC was compared with open tubular column SFC. Results show that as the particle diameter was decreased from 5 to 3 to 2 μm and the column length was reduced from 85 to 43 to 13 cm, the separation time could be reduced from 70 to 20 to 10 min while still maintaining similar separation (resolution). Short columns packed with small porous particles are very suitable for fast SFC separations of polymers.  相似文献   

8.
At near-critical temperatures and pressures, experimental results for elution of methane with neat carbon dioxide on a 150 mm x 2.0 mm I.D. column packed with 5 microm porous silica with a bonded octylsilica stationary phase show much greater efficiency losses than predicted by theory if isothermal conditions are assumed. Experiments with insulated, air- and water-thermostatted columns demonstrate that significant axial and radial temperature gradients are produced by Joule-Thomson cooling of the mobile phase, and that radial temperature gradients can be a major cause of band spreading at low temperatures and pressures. The use of thermal insulation on the column can greatly improve efficiency under these conditions.  相似文献   

9.
Summary The separation of polar thermally labile solutes is one of the potentially most rewarding fields of SFC application. A presupposition for such applications is, however, mobile phases having relatively high solvent strengths. A promising approach to achieve this is the use of mobile phases consisting of carbon dioxide with a polar additive. In this work, the chromatographic effects of different concentrations of an additive, isopropanol, in carbon dioxide have been studied on capillary and packed columns. A series of antibiotics was used as test substances. Best results were obtained with carbon dioxide/8% isopropanol as mobile phase on a capillary column coated with a cyanopropyl-substituted polysiloxane stationary phase.  相似文献   

10.
Summary Evaporative light scattering detectors can be used to detect organic substances without chromophoric groups in packed column supercritical fluid chromatography (SFC). A detector of this type has been used to detect squalane and glucose after SFC with various packed columns and binary mobile phases. In this study, the amount of organic modifier in carbon dioxide/modifier mixtures was varied. The results give further insight into the mechanisms that influence retention behaviour in packed column separations with super- and subcritical mobile phases. Squalane is an ideal non-polar test solute which shows long retention times on non-polar columns while its elution can be accelerated by non-polar modifiers in carbon dioxide. Glucose is an extremely polar solute containing hydroxyl groups. Elution of this sugar can be improved with polar modifiers. Column packings with polar end groups lead to high capacity ratios and long retention times for glucose. Most columns used in this study contained silica-based packing materials. For purposes of comparison, a polymeric packing (HEMA RP-18) was also employed.  相似文献   

11.
Trends in chromatographic shape selectivity with mobile phases consisting of mixtures of carbon dioxide and acetonitrile are investigated. Selectivity is evaluated as a function of mobile phase composition, temperature, and column bonding chemistry. SRM (standard reference material) 869a is used as a probe of shape selectivity, while the selectivity between triphenylene and o-terphenyl is used to investigate planarity selectivity. Four molecular mass 228 polyaromatic hydrocarbon isomers are used to investigate shape selectivity based on differences in length-to-breadth ratio. Shape selectivity trends as a function of temperature and column type are found to be similar to what is seen in reversed-phase liquid chromatography, while the trend seen as the amount of acetonitrile in the mobile phase increases is found to be different than in reversed-phase liquid chromatography. In addition, the effect of mobile phase density, i.e., solvent strength, on shape selectivity is investigated by examining shape selectivity as a function of density with neat carbon dioxide as the mobile phase.  相似文献   

12.
Chromatographic separation of styrene-methyl methacrylate (MMA) copolymers depending on the chemical composition was studied using liquefied carbon dioxide as an adsorption promoting solvent, and tetrahydrofuran, chloroform containing ethanol as a desorption promoting solvent in the mobile phase and the column packed non-bonded silica gel by a solvent gradient method. With the increase of MMA content, the elution was retarded indicating that the typical normal-phase type of adsorption occurred. The effects of type of desorption solvents, molecular mass of sample, and column temperature on the elution were investigated.  相似文献   

13.
The high-speed ion-exclusion chromatographic determination of dissolved carbon dioxide, i.e., carbonic acid, hydrogencarbonate or carbonate, with conductivity detection was obtained using a small column packed with a weakly acidic cation-exchange resin in the H+-form (40 mm long x 4.6 mm i.d., 3 microm-particle and 0.1 meq./ml-capacity). Two different ion-exchange resin columns, which were a strongly acidic cation-exchange resin in the K+-form and a strongly basic anion-exchange resin in the OH- -form, were connected after the separation column. The sequence of columns could convert dissolved carbon dioxide to KOH having high conductivity response. The enhancement effect for dissolved carbon dioxide could retain even on the vast chromatographic runs, by using the enhancement columns with high ion-exchange capacity above 1.0 meq./ml. The retention time was in 60 s at flow-rate of 1.2 ml/min. The calibration graph of dissolved carbon dioxide estimated as H2CO3- was linear in the range of 0.005-10 mM. The detection limit at signal to noise of 3 was 0.15 microM as H2CO3-. This method was applicable to several rainwater and tap water samples.  相似文献   

14.
The effect of pressure drop on the performance of supercritical fluid chromatography systems using a modified mobile phase (carbon dioxide + ethanol) was studied. Experiments were performed on a Lichrospher-RP-18 column with phenanthrene as a solute. A wide range of back pressures (130 to 210 bar) and modifier concentrations (2 to 7% w/w) have been explored. Experiments yielding both small and large pressure drops were performed. From these experiments, parameters to describe pressure drop, retention, and column efficiency were extracted, and were used to simulate the dynamics of the chromatographic column. A good match between the experimentally measured and calculated values of pressure drop, retention times, and column efficiency was observed. At low back pressure and modifier composition, significant loss of column efficiency was observed.  相似文献   

15.
刘晓微  杨海鹰  陆婉珍 《色谱》1997,15(1):22-24
 从速率方程和柱压降两个方面对加芯毛细管填充柱的柱效和渗透性进行了探讨,并详细讨论了柱直径、芯直径、芯根数和柱压降的关系。综合考虑柱压降、板高和拉制柱子时颗粒在柱内的镶嵌状况可知最佳柱型是3芯的毛细管填充柱。  相似文献   

16.
An analytical method for computing the residence time distribution of the liquid distribution system in chromatography columns is described. The impact of the distributor design on the separation efficiency is predicted as a function of media properties and packed bed dimensions. The efficiency loss due to the distributor when increasing column diameter during scale-up is quantified. It is shown that this loss can be compensated by modulating the local bed height via a moderate inclination of the bed support. It is concluded that the selection of an appropriate distributor design concept with optimised dimensions enables a scale-up of chromatographic separations without any significant loss of chromatographic efficiency due to the distribution system.  相似文献   

17.
In SFC, the key chromatographic parameters, the retention factors and the column efficiency, strongly depend on the density of the mobile phase. This indicates that the isodensity or isopycnic plots, drawn on the pressure-temperature plane, can provide an effective tool to help analyzing how the chromatograms obtained in SFC evolve, when the experimental conditions, the inlet and outlet pressures and the column temperature, are changed. In a companion paper, we analyzed the role of density in controlling the physical properties of the mobile phase, which in turn controls solute retentions and column efficiencies. In this report, we analyze the operating conditions in SFC with reference to the isopycnic plots of carbon dioxide. This analysis clarifies the differences and similarities between the operating conditions selected in the subcritical zone and those located in the supercritical zone. It also sets out an operational map illustrating how retention factors vary with respect to the operating temperatures and pressures. This study is focused on the use of pure carbon dioxide as the mobile phase, but the same method of investigation is also applicable when the mobile phase contains a modifier.  相似文献   

18.
R. Snel 《Chromatographia》1986,21(5):265-268
Summary A simple gas chromatographic system has been developed for the rapid on-line analysis of light Fischer-Tropsch products. This involves a single chromatography fitted with two columns, a porous-layer open-tubular column coated with KCl deactivated alumina and a packed Porapak-Q column. The capillary column separates the 16 most common C1−C4 hydrocarbons and permits a reasonable analysis of the hydrocarbons in the C5−C7 range. The packed column is used for the separation of methane, carbon monoxide, carbon dioxide, water and methanol. Retention characteristics for the analysis on the capillary column are presented. The total analysis cycle is 30 minutes.  相似文献   

19.
Paproski RE  Cooley J  Lucy CA 《The Analyst》2006,131(3):422-428
Two approaches for decreasing diesel hydrocarbon group-type separation times by normal phase supercritical fluid chromatography (SFC) are compared. Short (10-15 cm) columns with small 3 microm diameter packing are compared with monolithic Chromolith bare silica columns under high carbon dioxide flow rates approaching 5 ml min(-1). Elution times are reduced up to 13-fold on a 10 cm Chromolith column and 7-fold on the short packed columns compared with conventional length columns run at typical flow rates. Short packed columns, with their higher surface area and retention characteristics, offer higher resolutions compared with Chromolith columns. Diesel samples are separated into saturates, mono-, di-, tri-, and polyaromatics in as little as 2 min on a 10 cm packed silica column. Diesel group-type results on a 15 cm titania-silica coupled column compare favorably with results from longer columns.  相似文献   

20.
The operating characteristics of a solventless injector for packed column supercritical fluid chromatography are described. Successful operation depends on the difference between the volatilities of the analytes and the solvent or matrix being sufficient for their separation by gas purging in a thermostatted precolumn, and also on the existence of an effective re-focusing mechanism at the head of the analytical column for the sample dissolved in liquid or supercritical fluid carbon dioxide. The latter is easily achieved in density programmed operation by stationary phase trapping at low fluid densities or phase ratio trapping by changing the temperature at low to moderate fluid densities. The solventless injector can easily accommodate sample volumes from 1–100 μl and is easily adapted for in-line derivatization using reagents which can, after reaction, be eliminated by gas purging. For general purposes the solventless injector can be used to overcome most of the problems encountered when rotary valve loop injectors are used with small bore packed columns, and will probably replace this type of injector as the injector of choice for supercritical fluid chromatography with mobile phases of low polarity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号