首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
Summary Chenodeoxycholic acid in commerical drugs was analyzed by high-performance, thin-layer chromatography (HPTLC) using a cyanoalkyl chemically-bonded stationary phase, prepared by treating pre-coated silica with 3-cyanopropyltrichlorosilane (3CPTS). The 3CPTS-treated plates were used to evaluate commerical chenodeoxycholic acid in drug capsules. After development with methanol on the 3CPTS-treated plate, the chenodeoxycholic acid spot in the chromatogram was measured with a TLC densitometer equipped with a dual-wave length TLC scanner at λ=370nm. By this method, the fluorescence intensity of chenodeoxycholic acid was measured within 2.6% error over the range 30–240ng and the limit of detection was 30ng.  相似文献   

2.
3.
4.
Summary The retention and selectivity behaviour of bufadienolides (cinobufagin, resibufogenin, bufalin) inBufonis venenum have been studied by high-performance thin-layer chromatography on phenyl-modified silica plates, prepared from solutions of phenyldimethylethoxysilane, diphenylmethylethoxysilane or triphenylethoxysilane in toluene. Using various acetonitrile-distilled or methanol-distilled water mixtures as eluents, the bufadienolides have been separated on all the plates studied, but with different degrees of resolution. The selectivity for the separation of cinobufagin, resibufogenin, and bufalin between solutes and stationary phases is discussed. It is shown that monophenyl and diphenyltreated plates are more suitable for the selective separation of cinobufagin, resibufogenin, and bufalin inBufonis venenum than triphenyl-treated plates.  相似文献   

5.
Lipoxygenase derived monohydroxy polyunsaturated fatty acid methyl esters were separated by chiral high-performance liquid chromatography (HPLC) with a Chiralcel OD-H column in the normal-phase mode. Major lipoxygenase derivatives of linoleic, -linolenic and arachidonic acids are well resolved by this column, provided they have been individually purified. Our method allows an easy and rapid determination of lipoxygenases enantioselectivity. In all cases tested the R enantiomer is eluted first.  相似文献   

6.
An injection splitter in front of a glass capillary column was used for the hydrogenation of fatty acid methyl esters (FAME) mixtures. Hydrogenation followed by gas chromatographic analysis on capillary columns permitted detection and identification in complicated natural mixtures of branched fatty acids, showing minor structural differences, in quantities down to 10?8g. The technique described, apart from its suitability for FAME analysis, shows promise for structure determination studies of other classes of compounds.  相似文献   

7.
8.
High performance liquid chromatography of saturated, monounsaturated, diunsaturated, triunsaturated, cyclopropenoic (malvalic and sterculic) and cyclopropanoic (cis-8,9-methylenehexadecanoic and dihydrosterculic) fatty acids was performed with their methyl esters. All separations were carried out with two types of reversed phase columns, the eluent consisting of an acetonitrile/water mixture. The effect of water was studied in the range 0–15%. The best separation was obtained with acetonitrile/water (85:15 v/v). Quantitative results indicated that the detection limits depended upon ultraviolet wavelength and in the present study were 4 ng of methyl sterculate and 125 ng of methyl dihydrosterculate at 195 nm.  相似文献   

9.
10.
The study on retention behavior in supercritical fluid chromatography (SFC) is necessary to understand the mechanism of the various interactions in SFC. The retention of SFC in carboxylic acid methyl ester/polymethylsiloxane/CO2 system was studied systematically and the retention behavior of this kind of compounds under various typical operation conditions was described using the method of an alternative unified theory of chromatographic retention. The results illustrated that expression: Ink.= a + b/T + cp + dp/T + ep2/T can be used to describe quantitatively the retention behavior of carboxylic acid methyl ester/polymethylsiloxane/CO2 system in the ranges of reduced density from 0.549 to 1.411. It was also found that the entropy of solute in stationary phase is dependent on the density of supercritical fluid (SF) under typical operating conditions of SFC.  相似文献   

11.
The solvation parameter model is used to characterize the separation properties of the polar stationary phases EC-Wax and PAG with a poly(ethylene oxide) backbone (substituted with propylene oxide in the case of PAG) and the cyanopropyl-substituted polysilphenylene-siloxane stationary phase BPX90 at five equally spaced temperatures between 60 and 140 degrees C. The separation characteristics of these stationary phases are compared to four PEG and two poly(cyanopropylsiloxane) stationary phases (HP-20M, HP-Innowax, SolGel-Wax, DB-WAXetr, HP-88, and SP-2340) characterized in the same way. The database of system constants for these polar stationary phases is used to provide insight into the separation mechanism for fatty acid methyl esters and to determine selectivity differences that can be expected for generically similar stationary phase types. The discussion is not structured to indicate which stationary phase should be used for a particular separation but to provide a general framework to demonstrate the relationship between the retention mechanism and stationary phase chemistry.  相似文献   

12.
The separation of mixed mono-, di-, and triglycerides by capillary supercritical fluid chromatography is described. The separations were performed at low operating temperatures, using a carbon dioxide mobile phase, a conventional flame ionization detector, and two different stationary phases, DB-5 (95% dimethyl-(5%)-diphenylpolysiloxane) and DB-225 (50% cyanopropyl-methyl-(50%)-methylphenylpolysiloxane). Because the separations were performed at low operating temperatures, no thermal degradation of the glycerides was observed. Even under these mild operating conditions, trinervonin, a triglyceride having a molecular weight over 1100 amu, was readily eluted. When rapid pressure programming of the carbon dioxide mobile phase was employed, trinervonin was eluted in less than two minutes. On DB-5, the mono-, di-, and triglycerides eluted in order of increasing molecular weight. A graph of t′r (on DB-5) versus molecular weight is linear. When DB-225 was used as the stationary phase, triglycerides eluted in the order of increasing unsaturation. Thus, the order of elution on DB-225 was tristearin, triolein, trilinolein, and trilinolenin.  相似文献   

13.
Vegetable oil methyl esters are increasingly being used as substitutes for petroleum-based diesel fuels. Because the presence of triglycerides and partial glycerides in the fuel as a result of incomplete transesterification of vegetable oils can lead to serious engine problems, continuous quality control of the product is essential. A rapid gas chromatographic method has been developed for the quantitative determination of mono-, di-, and triglycerides in vegetable oil methyl esters. Prior to analysis, mono-, and diglycerides were silylated with N,O-bis(trimethylsilyl)trifluoroacetamide; tridecanoin was used as internal standard. Calibration was performed by analysis of standard solutions containing mono-, di-, and triolein: the calibration plots for mono- and diglycerides showed good linearity, whereas for triglycerides no linearity was observed for triolein concentrations below 0.05 mg/ml. When a non-linear multi level calibration was employed for the quantitation of triglycerides, the method gave excellent quantitative results for mono-, di-, and triglycerides in vegetable oil methyl esters.  相似文献   

14.
Measurement of contamination of marine and naval diesel fuels (arising from product mixing or adulteration) with biodiesel or fatty acid methyl esters can be problematic, especially at very low levels. A suitable solution for this task for trace amounts of individual fatty acid methyl esters with resolution and quantification can be achieved by using a multidimensional gas chromatographic approach with electron and chemical ionization mass spectrometric detection. A unique column set comprising a 100 m methyl‐siloxane nonpolar first dimension column and high‐temperature ionic liquid column in the second dimension enabled identification of individual fatty acid methyl esters at below the lowest concentrations required to be reported in a diesel fuel matrix. Detection limits for individual fatty acid methyl esters compounds ranged from 0.5 to 5.0 mg/L, with excellent linearity up to 5000 mg/L and repeatability of the method from 1.3 to 3.2%. The method was applied to the analysis of diesel fuel samples with suspected biodiesel contamination. Contamination at 568 mg/L was calculated for an unknown sample and interpretation of the results permitted the determination of a likely source of the contamination.  相似文献   

15.
The chromatographic efficiency that could be achieved in temperature‐programmed gas chromatography was compared for four capillary columns that are typically applied for analysis of fatty acid methyl esters (FAME). Three different carrier gases, hydrogen, helium and nitrogen, were applied. For each experiment, the carrier gas velocities and the temperature rates were varied with a full 9 × 3 design, with nine levels on the carrier gas velocity and temperature rates of 1, 2 or 3°C/min. Response surface methodology was used to create models of chromatographic efficiency as a function of temperature rate and carrier gas velocity. The chromatographic efficiency was defined as the inverse of peak widths measured in retention index units. The final results were standardized so that the efficiencies that could be achieved within a certain time frame, defined by the retention time of the last compound in the chromatogram, could be compared. The results show that there were clear differences in the efficiencies that could be achieved with the different columns and that the efficiency decreased with increasing polarity of the stationary phase. The differences can be explained by higher resistance to mass transfer in the stationary phase in the most polar columns.  相似文献   

16.
史雪岩  刘飞鹏  边庆花 《色谱》2016,34(1):85-88
手性2-芳基羧酸酯是制备手性非甾体抗炎药物2-芳基羧酸的重要的中间体,为了建立可用于2-苯基羧酸酯对映体分离的手性毛细管气相色谱法(CGC),分别使用2,6-二-O-戊基-3-O-丁酰基-β-环糊精及2,6-二-O-苄基-3-O-庚酰基-β-环糊精作毛细管气相色谱手性固定相,研究了其对2-苯基丁酸甲酯、2-苯基丁酸乙酯、2-苯基丁酸异丙酯、2-苯基丙酸甲酯及2-苯基丙酸环戊酯等5种2-苯基羧酸酯对映体的分离能力。结果表明,用2,6-二-O-戊基-3-O-丁酰基-β-环糊精及2,6-二-O-苄基-3-O-庚酰基-β-环糊精作手性固定相的毛细管气相色谱法可以分离2-苯基丁酸甲酯、2-苯基丙酸甲酯和2-苯基丙酸环戊酯对映体。2,6-二-O-戊基-3-O-丁酰基-β-环糊精对3种2-苯基羧酸酯对映体的分离能力超过了2,6-二-O-苄基-3-O-庚酰基-β-环糊精。  相似文献   

17.
18.
19.
Fatty acid methyl esters from various fats and oils were separated by comprehensive two-dimensional supercritical fluid chromatography with conventional packed columns and FID detection. The first dimension was a silica gel column and the second dimension was an ODS column. This combination was largely orthogonal for the separation of fatty acid methyl esters. The first dimension separations were primarily based on the number of double bonds while the second dimension separations were based on the chain length. The highly-ordered chromatograms and improved resolution allowed the easy detection and identification of minor components. Although the first dimension separations were performed under isobaric conditions where the peak width increased in proportion to the retention, the programming of the sampling duration allowed us to maintain the optimum re-injection frequency (3–4 times) per peak into the second dimension and so to minimize the total analysis time without deteriorating the resolution.  相似文献   

20.
α‐Methyl glutamic acid (L ‐L )‐, (L ‐D )‐, (D ‐L )‐, and (D ‐D )‐γ‐dimers were synthesized from L ‐ and D ‐glutamic acids, and the obtained dimers were subjected to polycondensation with 1‐(3‐dimethylaminopropyl)‐3‐ethylcarbodiimide hydrochloride and 1‐hydroxybenzotriazole hydrate as condensation reagents. Poly‐γ‐glutamic acid (γ‐PGA) methyl ester with the number‐average molecular weights of 5000∼20,000 were obtained by polycondensation in N,N‐dimethylformamide in 44∼91% yields. The polycondensation of (L ‐L )‐ and (D ‐D )‐dimers afforded the polymers with much larger |[α]D | compared with the corresponding dimers. The polymer could be transformed into γ‐PGA by alkaline hydrolysis or transesterification into α‐benzyl ester followed by hydrogenation. © 2001 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 39: 732–741, 2001  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号