首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Thermospray high performance liquid chromatography/mass spectrometry (TSP HPLC/MS) was used to analyze five Fusarium mycotoxins in porcine plasma and urine. Four cytotoxic trichothecene mycotoxins, T-2 toxin, HT-2 toxin, diacetoxyscirpenol (DAS), deoxynivalenol (DON), T2 tetraol, and the fungal estrogen zearalenone (F-2 toxin) were analyzed. The thermospray mass spectrum contained molecular weight information with few, if any, fragment signals. Detection limits ranging from 1 to 10 ng of mycotoxin injected onto the HPLC column were obtained using selected ion monitoring (SIM) HPLC/MS. Neither the plasma nor the urine matrix interfered with TSP HPLC/MS analysis of these mycotoxins and no sample derivatization was necessary for the analysis. The TSP HPLC/MS technique appears to be ideal for very sensitive analysis of mycotoxins in biological samples.  相似文献   

2.
Three bicyclic thioketones were examined by combined gas chromatography-mass spectrometry. Deuterium labelling was employed in the interpretation of the fragmentation processes in thiocamphor. Compared with the oxygen analogues, the thiones yielded on electron-impact a higher proportion of characteristic fragment ions containing the hetero-atom.  相似文献   

3.
The photochemical degradation of the fungicide cymoxanil {2-cyano-N-[(ethylamino)carbonyl]-2-(methoxyimino) acetamide} was studied in aqueous buffer solution (pH 5.9+/- 0.1) under UV light and in laboratory conditions. The degradation followed a pseudo- first-order kinetic with significant correlation coefficient. The main photoproducts were separated and tentatively identified by HPLC/UV and HPLC/MS data, as 3-ethyl-4-(methoxyamino)-2,5-dioxo-4-imidazolidinecarbonitrile, 1-ethyl-5-(methoxyimino)-2,4-imidazolidin-2,4-dione, ethylimidazolidinetrione and {[(ethylamino)carbonyl]-amino}oxoacetic acid. A photolysis pathway of cymoxanil is proposed.  相似文献   

4.
5.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

6.
A hydrophilic interaction liquid chromatographic method with tandem mass spectrometry for the determination of atenolol, a beta-blocking agent, in human plasma has been developed and validated over the curve range of 10--2000 ng/mL. The assay was based on protein precipitation followed by evaporation of the extraction solvent, reconstitution with acetonitrile, and chromatography on an Hypersil silica column (50 x 4.6 mm) using a low aqueous--high organic mobile phase. The mobile phase consists of 85% acetonitrile, 15% water, 0.5% acetic acid and 0.04% trifluoroacetic acid and runs isocratically at a flow rate of 2.0 mL/min. The column ef fluent was split so that 50% of it was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 2.0 min per injection. Atenolol and the internal standard, atenolol-d(7), showed a retention time of 1.0 min. The inter-day and intra-day precision and accuracy of the quality control samples were <5.3% relative standard deviation and <8.0% relative error, respectively. To explore the application of the current method for the analysis of other beta-blocking agents, propranolol and metoprolol were tested under the same chromatographic conditions with retention times of 0.68 and 0.75 min, respectively. The present method could be used for therapeutic drug monitoring, pharmacokinetic and drug--drug interaction studies of beta-blocking agents.  相似文献   

7.
A highly sensitive, rapid, and specific high pressure liquid chromatographic assay for the analysis of the antiarrhythmic agent mexiletine is reported. The method involves extraction of mexiletine with organic solvent followed by analysis using fluorescence detection. The minimum measurable limit is 1 ng and inter- and intra-day coefficients of variation are less than 5.8%. The method is useful for pharmacokinetic studies and routine serum monitoring of mexiletine.  相似文献   

8.
An automated liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method is presented for the screening and confirmation of 16 beta-blocking drugs in clinical and autopsy urine samples. The described method involved C(18) solid phase extraction, LC separation and MS analysis on a triple-stage quadrupole mass analyser. Samples were initially pre-screened for the presence of any beta-blocking drugs using LC/MS with selected ion monitoring. Any compounds tentatively identified as beta-blocking drugs on the basis of their LC retention time and protonated molecular ion were then automatedly subjected to a second analysis in which the relevant MS/MS product ion mass spectra were acquired. These product ion mass spectra were then automatically searched against a 400-substance mass spectral library containing previously acquired beta-blocking drugs. The results demonstrated that library search of beta-blocking drugs in urine with MS/MS product ion mass spectra was more reliable and produced fewer false negatives than library searching with mass spectra derived from single-stage quadrupole MS. The limits of identification in the MS/MS product ion scan ranged from 0.02 mg l(-1) for carvedilol to 1.2 mg l(-1) for pindolol, the majority of the values being below 0.2 mg l(-1).  相似文献   

9.
An improved liquid chromatographic tandem mass spectrometric method for the determination of glimepiride in human plasma has been developed and fully validated. The article describes in detail the bioanalytical procedure and summarizes the validation results obtained. The samples were extracted using liquid--liquid extraction with a mixture of 1-chlorobutane-isopropanol-ethyl acetate (88:2:10, v/v/v). The chromatographic separation was performed on a reversed-phase Hypersil ODScolumn (250 x 4.6 mm i.d.; 5 microm particle size) using a mobile phase consisting of formic acid 0.05 M-acetonitrile (28:72, v/v), pumped at a flow rate of 0.3 ml min(-1) heated to 25 degrees C. The analytes were detected using an API 3000 triple quadrupole mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. Tandem mass spectrometric detection enabled the quantitation of glimepiride down to 0.50 ng mL(-1). Calibration graphs were linear (r better than 0.998, n=1), in concentration range 0.50--1000 ng mL(-1), and the intra- and inter- day RSD values were less than 10.37 and 11.55% for glimepiride. The method was successfully applied to a kinetic study in order to assess the main pharmacokinetic parameters of glimepiride.  相似文献   

10.
11.
Air and waste samples coming from poultry breeding farms have been analysed by means of thermal desorption coupled to the gas chromatographic/mass spectrometric technique. The solid samples not only showed the presence of organic compounds such as acids, sulphides, benzopyrroles and phenols originated by anaerobic biotransfor-mation of the natural products, but also the occurrence of anti-oxidant substances: 2,6-di-tert-butylcresol, 2,6-di-tert-butylphenol and two of their oxidation derivatives. In the air, four artificial benzoquinones were detected, two of which had already been identified in the solid waste. In this work, the mechanism by which oxidized compounds are formed, is suggested.  相似文献   

12.
13.
Mercury-pyrrolidinedithiocarbamate complexes are first time used for speciation of aquatic mercury with high-performance liquid chromatographic/ion trap-mass spectrometric method utilizing atmospheric pressure chemical ionization (APCI). The separation of the four mercury species was achieved in less than 5 min with a linear gradient profile of aqueous methanol from 70 up to 100% (v/v) in 4th min, isocratic elution at 100% up to 5th min and followed by a negative gradient to 70% in 6th min. The best separation was achieved on a reverse phase Zorbax Eclipse XDB C18 column (50 mm × 2.1 mm i.d., 1.8 μm particle size). The on-column limits of detection (injection volume 1 μL) were 370 pg for methylmercury (MeHg+), 280 pg for ethylmercury (EtHg+), 250 pg for phenylmercury (PhHg+) and 90 pg for inorganic mercury (Hg2+) when the data were collected in selective ion monitoring (SIM) mode. A method of isolation and preconcentration of the mercury species using a “home-made” C18 solid phase extraction (SPE) microcolumns was developed to enhance sensitivity of the method. The preconcentration factor as much as 2500 was achieved with on-column complex formation of mercury-pyrrolidinedithiocarbamate. Methanol (100%) was chosen for elution of preconcentrated mercury species. The method was applied for the determination of mercury species in river water samples.  相似文献   

14.
Fullerene-rich soot generated by resistive heating of graphite has been gently extracted with toluene, in order to remove some C60 and C70 compounds, followed by extraction with boiling 1,2,4-trichlorobenzene at 214°C. After filtration and removal of the solvent, the residue was re-dissolved in dichloromethane and characterized by non-aqueous reversed phase liquid chromatography coupled on-line with atmospheric pressure chemical ionization mass spectrometry. Several novel fullerenes were detected, including C72, C80, C86, and C88 as well as other fullerenes up to C108 and higher. The results indicate that chromatographic separation of large fullerene molecules can be achieved with low boiling point solvents and conventional liquid chromatographic techniques.  相似文献   

15.
Ultra-fast chromatographic separations has enabled fast chromatographic method development and rapid analysis for sample quantification. Decreasing over-all analytical time has become a factor of major importance for all aspects of drug discovery. However, merely decreasing chromatographic analysis time by decreasing k' can lead to inconsistent quantitative or qualitative results due to ineffective separations in complex matrices. We have found that by changing column length and gradient slope we can maintain chromatographic integrity of chemically diverse analytes and achieve the analytical speed required for bioanalytical drug discovery quantitative analysis. We have optimized method development strategy by performing separations on 2x20 mm HPLC columns at flow-rates of 1.5 ml/min to 2 ml/min with full linear gradients achieved in 1 min for the quantification of pharmaceuticals and their metabolites from biological matrices. This method development strategy can be readily adapted to other matrices. This paper will discuss the effects of column length and gradient time in ultra-fast chromatographic resolution.  相似文献   

16.
This paper describes the first application of NMR spectroscopy and LC-NMR/MS to the direct analysis of the aromatic composition of beer, grape juice and a wine phenolic extract. NMR spectroscopy provides non-invasive information on the overall aromatic profile and enables the identification of some compounds. However, a more comprehensive assignment is hindered by the low peak intensity and strong signal overlap in the low-field spectral region, as well as by the inherent lack of scalar coupling information for many aromatic compounds present. LC-NMR/MS can overcome these problems and is shown to aid significantly in the identification of aromatic compounds composing all samples analyzed. Some examples are the identification of several cinnamic acids (e.g. p-coumaric, trans-coutaric and trans-caftaric) in grape juice, the identification of 2-phenylethanol, tyrosol and tryptophol in beer and the detection of phenolics such as catechin, epicatechin, trans-resveratrol, tyrosol and caffeic acid in the wine extract.  相似文献   

17.
A sensitive and specific method for the determination of morphine glucuronides in human plasma is presented. Morphine glucuronides, namely morphine-6-glucuronide (M6G) and morphine-3-glucuronide (M3G), were extracted from plasma by solid-phase extraction on C(18) cartridges at pH 9.3 and derivatized to their pentafluorobenzyl ester trimethylsilyl ether derivatives. The compounds were measured by gas chromatography/negative ion chemical ionization mass spectrometry without any further purification. Using this detection mode, a diagnostic useful fragment ion at m/z 748 was obtained at high relative abundance for both target compounds. [(2)H(3)]-labeled morphine glucuronides were used as internal standards. Calibration graphs were calculated by polynomial fit within a range of 10-1280 and 15-1920 nmol l(-1) for the 6- and 3-glucuronide, respectively. At the limit of quantitation (LOQ), the inter-assay precision was 2.21% (M3G) and 2.23% (M6G) and the GC/MS assay variability was 1.8% (M3G) and 0.9% (M6G). The accuracy at the LOQ showed deviations of +4.92% (M3G) and +1.5% (M6G). The sample recovery after solid-phase extraction was 84.7% for both M3G and M6G. The method is rugged, rapid and robust and has been applied to the batch analysis of morphine glucuronides during pharmacokinetic profiling of the drugs.  相似文献   

18.
19.
The regioisomers (sn-ABA/sn-AAB) of four triacylglycerols (TAGs), 18:2/18:2/18:1 (LLO), 18:2/18:1/18:1 (LOO), 16:0/18:1/18:1 (POO), and 16:0/16:0/18:1 (PPO), were quantified in lard, rapeseed oil, and sunflower seed oil by three different mass spectrometric methods using liquid chromatography (LC) and two different mass spectrometers. The ionization methods used were positive ion atmospheric pressure chemical ionization (APCI), positive ion electrospray ionization (ESI), and negative ion chemical ionization (NICI) with ammonia as the reagent gas. The LC/APCI-MS results with two different instrumentation types, LC/ESI-MS/MS and direct inlet ammonia NICI-MS/MS, were compared. The LC/APCI-MS method is based on the preferential formation of diacylglycerol (DAG) fragment ions during ionization by loss of sn-1/3 fatty acids from [M+H]+ ions. Similar formation of the DAG ions from [M+NH4]+ ions by collision-induced dissociation (CID) in the LC/ESI-MS/MS method and the [M-H--RCOOH-100]- ions from [M-H]- ions by CID in the direct inlet ammonia NICI-MS/MS method is observed. These methods were found to be useful and reliable in determining the regioisomeric structure of TAGs. No statistically significant differences were found between the results obtained with these methods. For LLO, LOO, and POO the proportions of sn-ABA isomer calculated from the results from all four methods were in rapeseed oil 7.7 +/- 6.5, 57.9 +/- 3.3, and 4.5 +/- 6.1%, respectively, and in sunflower seed oil 12.2 +/- 6.9, 34.0 +/- 5.2, and 1.4 +/- 2.8%, respectively. The proportions of ABA of POO and PPO in lard were 95.3 +/- 3.2 and 4.9 +/- 5.6%, respectively. This study also proved that the LC/APCI-MS/MS method examined is not applicable in the quantification of TAG regioisomers because the formation of DAG ions is not clearly dependent on the positional distribution of the fatty acids.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号