首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
5.
UV solar spectra have been measured, using a double-grating spectroradiometer, during population studies carried out across Europe for the EC Framework 7 funded ICEPURE project on the impact of climatic and environmental factors on personal UV radiation exposure and human health. Spectral field measurements have been conducted at ambient temperatures which varied between 11.5 and 33.5 °C. This temperature variation might affect instrument performance. The effect of ambient temperature was quantified and verified, and a model for temperature correction of spectral data is presented.  相似文献   

6.
In this article, the Young's modulus and the loss tangent of polydimethylsiloxane (PDMS) is obtained in the frequency range between 10 and 1500 Hz using an optical technique. The first three mechanical modes of vibrating PDMS beams are detected by measuring the tip rotational displacement using an optical lever. The experiments are carried out for 10:1 and 20:1 volume mixing ratios between the polymer base and the curing agent. The experimental results show that the Young's modulus varies between 1 and 2.6 MPa for 10:1 while its values are between 0.6 and 1.1 MPa for 20:1. The loss tangent is between 0.2 and 0.4 for 10:1 and 0.2 and 0.5 for 20:1. However, the measured values of the loss tangent are greater than the values reported in ref. 13. We also found that if the PDMS is not cured properly, its mechanical properties are time dependent. © 2015 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2016 , 54, 747–751  相似文献   

7.
8.
The empirical coefficient method represents the absorption and enhancement effect of each element on each other by parameters independent of mass concentrations. This method is used together with the internal standard method for the determination of cadmium, bromine and selenium by 14 MeV neutron activation followed by X-ray spectrometry. The results of analysis show a relative error not more than ±5%.  相似文献   

9.
The safety monitoring of lithium-ion batteries(LIBs) is of great significance for realizing all-climate and full-lifespan battery management. In-situ measurement of anode potential with implanted reference electrodes(REs) has proven to be effective to monitor and avoid the occurrence of severe side reactions like Li plating to ensure the safe and fast charging. However, the intrinsic measurement errors caused by local blocking effects, which also can be referred to as potential artefacts, are se...  相似文献   

10.
A method has been developed for the correction of counting losses in NAA for the case of a mixture of short-lived radionuclides. It is applicable to systems with Ge detectors and Wilkinson or successive approximation ADC's and will correct losses from pulse pileup and ADC dead time up to 90%. The losses are modeled as a constant plus time-dependent terms expressed as a fourth order polynomial function of the count rates of the short-lived radionuclides. The correction factors are calculated iteratively using the peak areas of the short-lived radionuclides in the spectrum and the average losses as given by the difference between the live time and true time clocks of the MCA. To calibrate the system a measurement is performed for each short-lived nuclide. In a test where the dead time varied from 70% at the start of the measurement to 13% at the end, the measured activities were corrected with an accuracy of 1%.  相似文献   

11.
The dependence of fluorescence decay times upon the refractive index of the solvent has been measured in two types of system: (a) in a single solvent at different temperatures, (b) in different solvents. The results are consistent with an n2 dependence of the radiative rate constant, as has been predicted theoretically.  相似文献   

12.
Paramagnetic metal ions can induce molecular alignment with respect to the magnetic field. This alignment generates residual anisotropic chemical shifts (RACS) due to nonisotropic averaging over the molecular orientations. Using a 30 kDa protein-protein complex, the RACS effects are shown to be significant for heteronuclear spins with large chemical shift anisotropies, lanthanide ions with large anisotropic magnetic susceptibility tensors, and measurements at high magnetic field. Therefore, RACS must be taken into account when pseudocontact shifts are measured by comparison of chemical shifts observed between complexes with paramagnetic and diamagnetic lanthanide ions. The results are of particular importance when different pseudocontact shifts measured for the 1HN, 15N, and 13C' spins of a peptide group are used to restrain its orientation with respect to the electronic magnetic susceptibility tensor in structure calculations.  相似文献   

13.
14.
It is difficult to do internal mass fractionation corrections for isotope dilution analysis by thermal ionization mass spectrometry (TIMS) or multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS), especially for MC-ICP-MS. In this study, calculation methods for direct internal fractionation correction of spiked isotope analysis by TIMS or MC-ICP-MS cycle by cycle for elements having at least two internal reference isotopic ratios are presented. For TIMS, direct internal mass fractionation correction calculation methods, based on both power and exponential laws, are derived; whereas for MC-ICP-MS, due to larger mass fractionation effects, only exponential law is considered. These calculation strategies can be applied for both static and multi-dynamic measurements. For multi-dynamic measurements, the isotope fractionation effect, gain and cup efficiency effects of different collectors, as well as ion beam fluctuation effects are all simultaneously eliminated. The calculation methods were verified by Sr isotopic analyses of spiked NBS987 standard solutions by TIMS and Hf isotopic analyses of spiked geological reference materials by MC-ICP-MS. In addition, precise and accurate calibrations of isotopic ratios of the spikes, based on the calculation methods, are discussed.  相似文献   

15.
A comparison of flame temperatures measured by the well-known spectroscopic “slope” method for Fe thermometric species residing in an isothermal, optically-thin environment shows that a range of 150°K is obtained when several different sets of recommended transition probabilities are used for the determinations. A similar lack of self-consistency is also shown by the temperatures obtained from two groups of Fe lines when the same set of transition probabilities is employed. These uncertainties have not been generally recognized.  相似文献   

16.
Electromagnetic response of individual boron nitride nanotubes (BNNTs) has been studied by spatially resolved electron energy loss spectroscopy (EELS). We demonstrate how dedicated EELS methods using subnanometer electron probes permit the analysis of local dielectric properties of a material on a nanometer scale. The continuum dielectric model has been used to analyze the low-loss EEL spectra recorded from these tubes. Using this model, we demonstrate the weak influence of the out-of-plane contribution to the dielectric response of BNNTs. The optical gap, which can be deduced from the measurements, is found to be equal to 5.8 +/- 0.2 eV, which is close to that of the hexagonal boron nitride. This value is found to be independent of the nanotubes configuration (diameter, helicity, number of walls, and interaction between the different walls).  相似文献   

17.
As a representative of traditionally fermented Chinese medicine, Massa Medicata Fermentata (MMF) shows the functions of invigorating the spleen and stomach and promoting digestion, which plays an important role in the treatment of gastrointestinal diseases. The fermentation mechanism and the key factors that affect the quality of MMF have not been revealed yet, which has become an urgent issue that limits its clinical application. This article aims to systematically and comprehensively reveal the transformation of physical properties and the dynamic trend of chemical components including substrate components, volatile components, and lactic acid as anaerobic fermentation product during MMF fermentation. Along with obvious hyphae growth observed for MMF, the weight of MMF decreased, and the moisture and temperature increased. Through the quantified 14 components from substrate, ferulic acid increased from 45.53 ± 6.94 to 141.89 ± 78.40 μg/g, while glycosides and phenolic acids declined except caffeic acid. Also, within the 66 volatile components analyzed, alcohols and acids increased, while aldehydes and ketones decreased. Lactic acid was not detected in the fermentation substrate, but an apparent increase in lactic acid content was observed along with the increased fermentation days, resulting in 2.54 ± 0.15 mg/g on day 8. Based on the tested components, the fermentation process of MMF was discriminated into three distinct stages by principal component analysis, and an optimal fermentation time of four days was proposed. The results of this study will be of great significance to clarify the characteristics of fermentation and conduce to improving quality standards of MMF.  相似文献   

18.
19.
The field of ion mobility mass spectrometry (IM‐MS) has developed rapidly in recent decades, with new fundamental advances underpinning innovative applications. This has been particularly noticeable in the field of biomacromolecular structure determination and structural biology, with pioneering studies revealing new structural insight for complex protein assemblies which control biological function. This perspective offers a review of recent developments in IM‐MS which have enabled expanding applications in protein structural biology, principally focusing on the quantitative measurement of collision cross sections and their interpretation to describe higher order protein structures.  相似文献   

20.
Precise gas viscosity measurements of Kestin and coworkers and a simple capillary viscometer have been used to test the classical slip correction at 25°C and one atmosphere pressure. The results indicate that for capillaries with diameters between 0.015 and 0.025 cm. this correction is two to three times smaller than normally used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号