首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method has been developed to analyse for malachite green (MG), leucomalachite green (LMG), crystal violet (CV) and leucocrystal violet (LCV) residues in salmon. Salmon samples were extracted with acetonitrile:McIIIvain pH 3 buffer (90:10 v/v), sample extracts were purified on a Bakerbond strong cation exchange solid phase extraction cartridge. Aliquots of the extracts were analysed by LC-MS/MS. The method was validated in salmon, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 0.17, 0.15, 0.35 and 0.17 microg kg(-1), respectively, for MG, LMG, CV and LCV and for the detection capability (CCbeta) values of 0.30, 0.35, 0.80 and 0.32 microg kg(-1), respectively, were obtained. Fortifying salmon samples (n=6) in three separate assays, show the accuracy to be between 77 and 113% for MG, LMG, LCV and CV. The precision of the method, expressed as RSD values for the within-laboratory reproducibility, for MG, LMG and LCV at the three levels of fortification (1, 1.5 and 2.0 microg kg(-1)), was less than 13%. For CV a more variable precision was obtained, with RSD values ranging between 20 and 25%.  相似文献   

2.
An ultraviolet spectrophotometric method was validated for total flavonoid quantitation, as rutin equivalents, present in the Trichilia catigua Adr. Juss (Meliaceae) and Ptychopetalum olacoides Bentham (Olacaceae) commercial extract. Parameters as linearity, interval (range), specificity, estimated limit of detection (LOD, microg/mL), estimated limit of quantitation (LOQ, microg/mL), recovery (R, %), precision or relative standard deviation (RSD, %), and accuracy (E, %) were established. The analytical method was validated according to the experimental results: correlation coefficient (r = 0.9997); interval (RSD = 0.15-0.47%; E = 98.98-101.24%); specificity to total flavonoids quantitation, as rutin equivalents, at wavelength 361.0 nm; LOD = 0.09 microg/mL and LOQ = 0.27 microg/mL; R = 99.36-102.14%; adequate intra- and interrun precision (0.30-0.49% and 0.31-0.81%), and intra- and interrun accuracy (100.60-102.38% and 98.58-100.38%).  相似文献   

3.
A method for quantification of the fine particle dose of lactose is described, using a hydrophilic interaction chromatography (HILIC) method and evaporative light scattering detection. The HILIC method used an aminopropyl column and a mobile phase consisting of acetonitril/water (80/20, v/v) for isocratic elution. Sensitive chromatography was obtained using a low concentration of water in the extraction solvent. The detection limit (RSD<10%) at an injection volume of 10 microL is 10 microg/mL. Linearity was obtained in the range of 10-80 microg/mL (R(2)>0.99). A relative standard deviation (RSD) of 0.5% (N=6) demonstrated good precision of the optimized method.  相似文献   

4.
AQC柱前衍生化RP-HPLC法测定蒜氨酸及其有关物质的含量   总被引:1,自引:0,他引:1  
袁耀佐  杭太俊  纪宇  张正行 《色谱》2008,26(2):242-245
采用6-氨基喹啉-N-(羟基琥珀酰亚胺基)氨基甲酸酯(6-aminoquinolyl -N- Hydroxysuccinimide Carbamate ,AQC)为柱前衍生化试剂,建立了AQC柱前衍生化RP-HPLC法测定蒜氨酸及其有关物质的含量。该衍生化方法反应瞬间完成,衍生化产物稳定。色谱条件为:Kromasil C18柱(250mm×4.6mm,5mm),流动相A为0.1%乙酸铵(含0.03%乙酸),流动相B为水-乙腈(40∶60),线性梯度洗脱,流速1.0ml/min,检测波长248nm。蒜氨酸在1.1719~1500μg /ml浓度范围内线性关系良好(r=0.9998), 日内、日间精密度良好(RSD <1.8%,n=5), 加样回收率为99.1%(RSD1.9%,n=5),检测限为3ng,该方法准确、方便、快速。  相似文献   

5.
Qin W  Li SF 《Electrophoresis》2002,23(24):4110-4116
Ionic liquid (IL) was covalently bonded onto the silica capillary surface and the electroosmotic flow was reversed over a pH range of 3.5 to 7. Sildenafil (SL) and its metabolite UK-103,320 (UK) in human serum were detected by solid-phase extraction followed by capillary zone electrophoresis-mass spectrometry analysis. The running buffer contained 10 mM acetic acid adjusted to pH 4.5 with 1 M ammonia, and the separating voltage was set to -25 kV. The adsorption of the analytes onto the bare capillary wall was eliminated by the IL coating and the drugs were baseline-separated within 14 min with detection limits (S/N = 3) of 14 and 17 ng/mL for SL and UK, respectively. The method developed showed good intraday precision in terms of relative standard deviation (RSD) with respect to migration time (RSD 相似文献   

6.
A simple method was developed and validated for the trace determination of 2-isopropylthioxanthone (ITX) in packaged drinks. Samples were extracted from the food matrix using acetonitrile:water (60:40, v/v), and further subjected to clean-up and preconcentration using solid-phase extraction prior to analysis by liquid chromatography-tandem mass spectrometry using multiple reaction monitoring (MRM) mode. The use of 2-isopropyl-[(2)H7]thioxanthen-9-one was incorporated into the method as an internal standard. Excellent 3-day interday precision data (RSD 0.72%, n=10), and intraday precision data (RSD 0.52%, n=10) were obtained on a 0.10 microg/L standard solution. Spiked samples (n=8) were used to gauge the accuracy of the method at the concentration levels of 2.5, 100, and 500 microg/kg in food; recoveries ranged from 97.0 to 103.0%. These excellent validation data suggest the exciting possibility of using this method for the determination of low levels of ITX migrating from printed food packaging materials into beverages with a method quantitation limit of 0.50 microg/kg. For the first time, analysis on a range of milk, juice, tea and yoghurt drinks, as well as their respective food packaging materials were performed for comparative studies on their ITX content.  相似文献   

7.
Fast and sensitive packed capillary column switching liquid chromatography methodology has been developed for the determination of the pesticide rotenone in river water. Sample volumes of up to 1 ml are loaded onto a 23 x 0.25 mm, 5 microm Kromasil C18 packed capillary precolumn using a noneluting solvent composition of water-acetonitrile (99:1, v/v) at flow-rates up to 100 microl/min prior to solute backflushing onto a 200 x 0.32 mm, 3.5 microm Kromasil C18 packed capillary analytical column using a mobile phase of water-acetonitrile (30:70, v/v) at a flow-rate of 5 microl/min. The method was evaluated using river water samples spiked with rotenone in the concentration range 0.5-50 ng/ml using UV detection. The within-assay precision was between 5.0 and 7.7% relative standard deviation (RSD, n = 6) and the between assay precision was between 7.5 and 8.9% RSD (n = 6). The method was linear within the investigated mass range displaying a calibration curve correlation factor of 0.997. The mass limit of detection was 10 pg corresponding to a concentration limit of detection of 10 pg/ml, using time-of-flight mass spectrometry.  相似文献   

8.
郑萍  谢笑天  刘频 《色谱》1997,15(6):539-541
 用高效液相色谱法测定了三元混配除草剂“农家益”中甲黄隆、苄嘧黄隆、乙草胺的含量。甲黄隆、苄嘧黄隆及乙草胺的平均回收率分别为98.81%,99.10%,99.72%,线性关系良好。所建立的方法用于“农家益”的质量控制具有准确、快速、重现性好等优点。  相似文献   

9.
A simple and sensitized spectrophotometric method for the determination of trace amounts of beryllium has been described. The method is based on the formation of a ternary complex by the reaction of beryllium with haematoxylin in the presence of micellar medium (cationic surfactant, cetyltrimethylammonium bromide). The ternary complex of beryllium has a maximum absorbance at 592 nm and showed an excellent sensitivity (molar absorption coefficient of 7.07 x 10(4)L mol(-1)cm(-1) and the Sandell's sensitivity being 1.27 x 10(-4) microg cm(-2)) and reproducibility (within-day precision: R.S.D.相似文献   

10.
A method has been developed for the determination of zinc pyrithione (ZnPT) in environmental water samples using monolithic reversed-phase silica columns for rapid on-line large volume solid phase extraction in tandem with on-line matrix removal using sacrificial strong anion exchange (SAX) columns. This is coupled with reversed-phase liquid chromatography with atmospheric pressure chemical ionisation mass spectrometric detection. Limits of detection in spiked river water samples, using a 200 mL preconcentration volume, were determined as 18 ng L(-1), with a limit of quantitation of 62 ng L(-1). The percentage recovery from spiked river water was found to be 72+/-9 (n=3 extractions), whilst overall method precision, following 10 repeat complete analyses was found to be 27% RSD at 1 microg L(-1). Linearity was determined over the concentration range of 0.25-10 microg L(-1) and the calculated regression coefficient was R(2)=0.9802. The method was used to investigate the environmental fate of zinc pyrithione in waters and its partition coefficient between sediment and water phases.  相似文献   

11.
Part of a comprehensive study on the comparison of different extraction methods, GC-MS(/MS) and LC-MS/MS detection methods and modes, for the analysis of soya samples is described in this paper. The validation of an acetone-based extraction method for analysis of 169 pesticides in soya, using LC-MS/MS positive and negative electrospray ionisation (ESI) mode, is reported. Samples (5 g) were soaked with 10 g water and subsequently extracted with 100 mL of a mixture of acetone, dichloromethane and light petroleum (1:1:1), in the presence of 15 g anhydrous sodium sulphate. After centrifugation, aliquots of the extract were evaporated and reconstituted in 1.0 mL of methanol, before direct injection of the final extract (corresponding with 0.05 g soya mL(-1)) into the LC-MS/MS system. Linearity, r(2) of calibration curves, instrument limit of detection/quantitation (LOD/LOQ) and matrix effect were evaluated, based on seven concentrations measured in 6-fold. Good linearity (at least r(2)> or =0.99) of the calibration curves was obtained over the range from 0.1 or 0.25 to 10.0 ng mL(-1), corresponding with pesticide concentrations in soya bean extract of 2 or 5-200 microg kg(-1). Instrument LOD values generally were 0.1 or 0.25 ng mL(-1). Matrix effects were negligible for approximately 90% of the pesticides. The accuracy, precision and method LOQ were determined via recovery experiments, spiking soya at 10, 50, 100 microg kg(-1), six replicates per level. In both ESI modes, method LOQ values were mostly 10 or 50 microg kg(-1) and more than 70% of pesticides analysed by each mode met the acceptability criteria of recovery (70-120%) and RSD (< or =20%), at one or more of the three levels studied. A fast, easy and efficient method with acceptable performance was achieved for a difficult matrix as soya, without cleanup.  相似文献   

12.
高效阴离子交换色谱在易极化阴离子痕量分析中的应用   总被引:3,自引:0,他引:3  
以45 mmol/L的 NaOH溶液作淋洗液,采用强亲水性的IonPac AS16阴离子交换分析柱和脉冲安培检测器,在15 min内分离检测了Br-,S2O2-3,I-和SCN-4种易极化阴离子,检测限(以3倍信噪比计)分别为0.5,0.2,0.05和2 μg/L (进样25 μL)。痕量离子的标准溶液平行9次进样测定的相对标准偏差为0.8%~3.7%。而在相同的色谱条件下,抑制型电导检测器对上述4种阴离子的检测限分别为1,1,2和10 μg/L,平行9次进样测定的相对标准偏差为0.9%~4.7%。通过实验比较可知,脉冲安培检测器的灵敏度是抑制型电导检测器的2~40倍。在测定上述易极化阴离子时,脉冲安培检测器具有选择性强、精密度好和灵敏度高等优点。  相似文献   

13.
A liquid chromatographic (LC) method was validated for the determination of total vitamin B6 in infant formula. Total vitamin B6 was quantified by converting the phosphorylated and free vitamers into pyridoxine. Pyridoxine was determined by ion pair reversed-phase LC with fluorescence detection. The method was subjected to an AOAC collaborative study involving a factory-manufactured, milk- and soy-based infant formula. Each was spiked at 3 concentrations in the range of 0-1 microg/g and sent as blind duplicate to participant laboratories. Nine laboratories returned valid data which were statistically analyzed for outliers and precision parameters. The repeatability relative standard deviation (RSD(r)) ranges were 2.0-4.0 and 3.5-5.9% for fortified milk- and soy-based formulas, respectively. The reproducibility relative standard deviation (RSD(R)) ranges were 8.2-8.4 and 6.7-11.2% for fortified milk- and soy-based formulas, respectively. HORRAT values ranged from 0.42 to 0.53, indicating that the precision of the method is acceptable. The mean RSD(r):RSD(R) values were 0.60 and 0.55 for milk- and soy-based formulas, respectively. As expected, RSDs for the unfortified samples were higher, but their HORRAT values (0.81 and 2.06) helped define a realistic limit of quantitation as 0.05 microg/g. Recovery data were quantitative and varied between 81.4 and 98.0% (mean = 89.8%) for each of 6 spiked materials.  相似文献   

14.
A simple and sensitive spectrophotometric method was developed for the determination of trace amounts of sulfur dioxide. The method is based on the reaction of SO2 with a known excess of ICI as the oxidant. The unreacted ICI iodinates thymol blue under acidic conditions. The lambdamax of thymol blue is at 545 nm under acidic conditions, and on lodination lambdamax shifts to 430 nm. This shift results in a decrease in the absorbance at 545 nm. The amount of uniodinated thymol blue present depends on the concentration of unreacted ICI, which in turn depends on the SO2 concentration. The system obeys Beer's law in the range 0-30 microg SO2 in a final volume of 25 mL, having a molar absorptivity of 3.2 x 10(4) L/mol cm with a relative standard deviation (RSD) of 2% at 24 microg SO2 (n = 10). The uniodinated dye can be extracted into 5 mL isoamyl alcohol under acidic conditions for measurement of absorbance. The extraction method obeys Beer's law in the range 0-5 microg SO2, having a molar absorpitivity of 4.16 x 10(4) L/mol x cm with an RSD of 1.9% at 4 microg SO2 (n = 10). The method has been successfully applied to the determination of atmospheric SO2.  相似文献   

15.
A rapid and simple high-performance liquid chromatographic method for the analysis of 1,3-dihydroxy-2-methylxanthone (DHMXAN) in biodegradable poly(D,L-lactide-co-glycolide) (PLGA) nanosphere and nanocapsule formulations is developed and validated. The method does not require any complex sample extraction procedure. Chromatographic separation is made with a reversed-phase C18 column, using methanol-water (90:10, v/v) containing 1% (v/v) acetic acid as a mobile phase at a flow rate of 1 mL/min. Identification is made by UV detection at 237 nm. The isocratic system operates at ambient temperature and requires 7.5 min of chromatographic time. The developed method is statistically validated according to ICH guidelines and USP 29 for its specificity, linearity, accuracy, and precision. The assay method proposed in this study is specific for DHMXAN in the presence of nanosphere and nanocapsule excipients. Diode-array analyses confirm the purity of DHMXAN peak in stress conditions (> 99.0%). The method is shown to be linear (r > or = 0.999) over the concentration range of 0.25-3.0 microg/mL. Recovery ranges from 99.0% to 102.7% (RSD: 1.49%) and from 98.3% to 101.6% (RSD: 1.07%) for nanospheres and nanocapsules, respectively. Repeatability (intra-assay precision) and intermediate precision is acceptable with RSD values ranging from 0.6% to 1.9% and from 0.3% to 2.0%, respectively. The method is shown to be suitable for the evaluation of DHMXAN content entrapped in PLGA nanoparticles.  相似文献   

16.
Within the framework of a European Union (EU) research project entitled "Food Safety Screening: Synthetic Glucocorticoids (QLK1-1999-00122)," an international interlaboratory ring test was organized to compare and evaluate different liquid chromatography/mass spectrometry (LC/MS) confirmatory methods that are applied in European monitoring programs for detecting the use of synthetic glucocorticoids. Liver and urine samples of bovines treated with synthetic glucocorticoids were collected and sent to the participants of the study for analysis. Participants received 3 liver and 3 urine samples and were free to use either their own LC/MS method or an LC/MS-based method developed during the EU research project. The residue concentrations in the samples were calculated as the mean of the concentrations reported by each laboratory. The mean dexamethasone concentration of liver sample L1 was calculated as 2.27 microg/kg [relative standard deviation (RSD) 43%, n = 9], which exceeds the maximum residue level (MRL) of 2 microg/kg. Three of the 9 laboratories (33%) reported concentration levels less than 2 microg/kg, resulting in obviously false compliant results. The overall mean concentration of flumethasone in liver sample L2 was calculated as 3.27 microg/kg (RSD 33%, n = 8). Applying a comparable limit for flumethasone of 2 microg/kg, 8 of the 9 laboratories would have obtained a correct noncompliant result. As for the blank liver sample, 1 participant found a false noncompliant result. The urine sample U1 contained prednisolone residues at a mean concentration of 1.58 microg/kg (RSD 43%, n = 9). Four out of 9 results were less than a theoretical minimum required performance level (MRPL) of 2 microg/kg. The calculated concentration of dexamethasone in urine sample U3 was 5.21 microg/kg (RSD 62%, n = 9). One of the 9 results was lower than 2 microg/kg. Urine sample U2 was correctly reported as blank by all participants.  相似文献   

17.
Polyethylene glycol (PEG) 20000 in low-density polyethylene has been determined using column switching and inverse temperature programming in reversed-phase packed capillary liquid chromatography with evaporative light scattering detection. PEG 20000 was extracted into water from the polyethylene dissolved in toluene and PEG 35000 was added as an internal standard (I.S.). The samples in aliquots of 100 microl were reconcentrated on the enrichment column using a loading mobile phase of acetonitrile-water (3:97, v/v) at a flow-rate of 75 microl/min for 3 min, then back-flushed and separated on the analytical column with acetonitrile-THF-water (40:5:55, v/v) as mobile phase. The column temperature was reduced from 68 to 55 degrees C with a ramp of -1.5 degrees C/min, held constant for 3 min and then reduced further to 45 degrees C with a -1.5 degrees C/min ramp and kept constant for 1 min. The analysis runtime was 20 min. The recovery of PEG 20 000 was determined to 65.1% with 2.8% RSD and the mass limit of detection of PEG 20 000 was 1.25 microg. The within-assay and between day precision of the retention times of both PEG 20000 and PEG 35000 displayed RSD of less than 1.1% (n = 9), while the overall area ratio RSD of 100 microg/ml PEG 20000 over PEG 35000 was 1.3% (n = 9). The method was linear within the investigated concentration range 25-125 microg/ml (R2 = 0.9983). In addition, a mixture of PEG 4000, 8000, 10000, 20000 and 35000 was analysed on the system to demonstrate the possibility of analysing several PEGs in a sample with the use of temperature gradient elution.  相似文献   

18.
This paper presents development of a simple, rapid, and precise analytical method for determination of sulfur dioxide in ambient air by a gas to solid-phase conversion method. Sulfur dioxide is determined in the form of sulfite (SO3(2-)) because the absorbing reagent, potassium tetrachloromercurate (TCM), used in this method absorbs sulfur dioxide from the atmosphere in the form of sulfite. Determination of submicrogram levels of sulfur dioxide was based on the selection of a quantitative analytical peak at 495 cm(-1) among the 3 observed vibrational peaks for the dichlorosulfitomercurate complex formed after reaction of sulfur dioxide with TCM and measurement of absorbance using diffuse reflectance Fourier transform infrared spectroscopy. The limits of detection and quantification of the method were found to be 0.09 and 0.4 microg/g SO3(2-), respectively. The precision in terms of standard deviation and relative standard deviation (RSD) at a level of 2 microg SO3(2-)/10.1 g KBr for n = 10 was found to be 0.036 microg SO3(2-) and 1.8%, respectively. The RSD (n = 10) for determination of sulfur dioxide in ambient air was observed to be in the range of 2.7-4.2%. The method proposed is time saving and eliminates the slow and cumbersome steps of pH maintenance of the reaction mixture and color formation of the U.S. Environmental Protection Agency recommended West and Gaeke spectrophotometric method and other methods for quantitative determination of sulfur dioxide.  相似文献   

19.
A simple and solvent-minimised sample preparation technique based on hollow fibre-protected liquid-phase microextraction was investigated for the gas chromatography/mass spectrometric analysis of chemical warfare agents in water and slurry samples. The chemical warfare agents included four nerve agents and a blister agent. Parameters such as extraction solvent, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The technique provided a linear range of two orders of magnitude, good repeatability (RSDs < 10%, n = 6), good linearity (r2 >or= 0.995) and limits of detection (LODs) in the range of 0.02-0.09 microg l(-1) (S/N = 3) under full scan mode. The optimised technique was also applied to more complex slurry samples and similar precision (RSD < 15%, n = 3) and limits of detection (0.02-0.2 microgl(-1), S/N = 3) were obtained.  相似文献   

20.
Two simple, rapid, and efficient methods for the analysis of seven antifungal compounds have been developed by capillary zone electrophoresis. Resolutions higher than 1.5 were obtained using 0.025 M phosphate buffer (pH 2.30) (analysis time close to 9 min) or 0.2 M formic acid (pH 2.15) (analysis time close to 6 min), with an applied voltage of 20 kV and a temperature of 30 degrees C. The highest sensitivity and selectivity can be obtained using phosphate buffer but the shortest analysis times are achieved in the formic system. The analytical characteristics of the optimized methods were investigated. The reproducibility obtained for migration times (RSD(n = 10) < or = 1.0%) and peak areas (RSD(n = 10) < or = 4.3%) was acceptable, but better reproducibilities were obtained when verapamil was used as internal standard (RSD(n = 10) < 0.4% for relative migration times and RSD(n = 10) < or = 2.2% for peak area ratios). The lowest limit of detection was obtained for clotrimazole (0.12 microg/ml) and the highest for fluconazole and voriconazole (0.90 microg/ml). The lowest and the highest limits of quantitation were, respectively, 0.40 microg/ml for clotrimazole and 3.00 microg/ml for fluconazole and voriconazole.  相似文献   