首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 859 毫秒
1.
A novel approach in glycosaminoglycomics, based on sheathless on-line capillary electrophoresis/nanoelectrospray ionization-quadrupole time of flight-mass spectrometry (CE/nanoESI-QTOF-MS) and tandem MS of extended chondroitin sulfate/dermatan (CS/DS) oligosaccharide chains is described. The methodology required the construction of a new sheathless CE/nanoESI-QTOF-MS configuration, its implementation and optimization for the high sensitivity analysis of CS/DS oligosaccharide mixtures from conditioned culture medium of decorin transfected human embryonic kidney (HEK) 293 cells. Under newly established sheathless on-line CE/(-)nanoESI conditions for glycosaminoglycan (GAG) ionization and MS detection, single CS/DS oligosaccharide components of extended chain length and increased sulfation degree were identified. Molecular ions corresponding to species carrying 5 and 6 negative charges could be generated for large GAG oligosaccharide species in the negative ion nanoESI-MS. The optimized on-line conditions enabled the detection of molecular ions assigned to oversulfated tetradeca-, octadeca-, and eicosasaccharide CS/DS molecules, which represent the category of largest sulfated GAG-derived oligosaccharides evidenced by CE/ESI-MS. By on-line CE/ESI tandem MS in data-dependent acquisition mode the oversulfated eicosasaccharide species could be sequenced and the localization of the additional sulfate group along the chain could be determined.  相似文献   

2.
Li FA  Wang CH  Her GR 《Electrophoresis》2007,28(8):1265-1273
Using a wire-assisted epoxy-fixing method, a sheathless CE/MS interface on a poly-(methyl methacrylate) (PMMA) CE chip has been developed. The sheathless chip-CE/MS interface utilized a tapered fused-silica tip and the electrical connection was achieved through a layered coating of conductive rubber. The wire-assisted method provided facile alignment of channels between the PMMA CE chip and an external capillary sprayer without the need for micromachining. Because the wire was in the channel during fixing, the risk of channel blockage by the epoxy was avoided. This chip CE device has minimal dead volume because the interstitial spaces were filled by a fast-fixing epoxy resin. The performance of the chip-CE-ESI-MS device was demonstrated with the analysis of peptide mixtures.  相似文献   

3.
An in-capillary electrode sheathless interface was applied to the capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) analysis of mixtures of small peptides, proteins, and tryptic digests of proteins. The effects of different experimental parameters on the performance of this CE/ESI-MS interface were studied. The distance of the in-capillary electrode from the CE outlet and the length of the electrode inside the capillary had no significant effects on the CE separation and ESI behavior under the experimental conditions used. However, significant enhancement of the sensitivity resulted from the use of narrower CE capillaries. Using a quadrupole mass spectrometer, an aminopropylsilane-coated capillary, and a wide scan mass-to-charge ratio range of 500–1400, detection limits of approximately 4, 1, and 0.6 fmol for cytochrome c and myoglobin were achieved for 75-, 50-, and 30-µm inner diameter capillaries, respectively. Approximately one order of magnitude lower detection limits were achieved under the multiple-ion monitoring mode. The application of the in-capillary electrode sheathless interface to real-world samples was demonstrated by CE/ESI-MS analysis of a human blood sample.  相似文献   

4.
A simple sheathless capillary electrophoresis (CE)/mass spectrometry (MS) interface was constructed by combining widely used nanospray needles with fused-silica capillaries and it was successfully applied for the separation of peptides. The end of the CE capillary was pulled to a taper, etched and then fitted into the metal-coated nanospray borosilicate capillary. The nanospray needle can be used for several CE runs, but it can be easily and rapidly changed in the case of accidental breakage or evaporation of the coating. A fast capillary electrochromatographic method was also developed for MS analysis of peptides containing numerous basic amino acids.  相似文献   

5.
Tapered stainless steel spray tips for sheathless microelectrospray ionization (microESI) have been developed. The fabrication procedure for the tapered stainless steel tips was optimized using an electropolishing technique followed by removal of the burr. Using the tip as the microESI emitter, a stable ESI spray was obtained at a flow rate of 20 nL/min. The sensitivity of the microESI system was almost two orders greater than that of the conventional ion spray system. The tip was highly stable, and was successfully used for over 1000 h. Moreover, these stainless steel tips were suitable for use with sheathless capillary electrophoresis/mass spectrometry (CE/MS) and capillary liquid chromatography/mass spectrometry (LC/MS) for routine analysis in proteomic and pharmaceutical applications.  相似文献   

6.
Here, we present a miniaturized version of the flowing atmospheric-pressure afterglow (miniFAPA) ion source and use it for sheathless coupling of CE with MS. The simple design of the CE-miniFAPA-MS interface makes it easy to separate the electric potentials used for CE and for ionization. A pneumatically assisted nebulization of the CE effluent transfers the analytes from the liquid phase into the gas phase before they are ionized by interacting with reactive species produced by the FAPA. An important advantage of this interface is its high stability during operation: optimization of five different parameters indicated that the interface is not sensitive to minor deviations from the optimum values. Other advantages include ease of construction and maintenance, as well as relatively low cost. Samples with complex matrices, such as yeast extract, soil extract and urine, spiked with the test compounds, were successfully analyzed using the CE-miniFAPA-MS setup.  相似文献   

7.
A simple and rugged sheathless interface for capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) was designed using common laboratory tools and chemicals. The interface uses a small platinum (Pt) wire that is inserted into the CE capillary through a small hole near the terminus. The position of the wire inside the CE capillary and within the buffer solution is analogous to standard CE separation operations where the terminus of the CE capillary is placed inside a buffer reservoir along with a grounded platinum electrode. By combining the use of the in-capillary electrode interface with sharpening of the fused silica tip of the CE capillary outlet, a stable electrospray current was maintained for an extended period of time. The design was successfully applied to CE/ESI-MS separations and analysis of mixtures of peptides and proteins. A detection limit of approximately 4 femtomole (S/N = 3) was achieved for detection of myoglobin utilizing a 75-µm-i.d. aminopropylsilane treated CE column and using a wide scan range of 550–1300 Da. The advantages of this new design include (1) a stable CE and ESI current, (2) durability, (3) a reduced risk of sparking between the capillary tip and the inlet of the mass spectrometer, (4) lack of any dead volume, and (5) facile fabrication with common tools and chemicals.  相似文献   

8.
With the combination of high separation ability of capillary electrophoresis (CE) and strong identification ability of mass spectrometry (MS), CE/MS is becoming a powerful tool for polar and ionic analytes analysis. Different interfaces have been developed to enhance the sensitivity and reliability since the first introduction of CE/MS in 1987. A sheathless porous interface based on a new ions transferring electric connection technique was reported to be with high sensitivity and reliability. In this work, a series of optical and electrochemical experiments were designed to study the electric connection process. The results indicated that closing CE electrical circuit and applying MS spray voltage were achieved by the small ions transferring through the interface porous wall. The new electric connection method significantly enhanced the sensitivity, resolution and stability of the CE/MS analysis. The interface was applied in CE/MS detection of morphine and 6‐monoacetylmorphine in urine sample and showed an equal sensitivity to LC/MS. With the significant improvement of sensitivity and stability, the CE/MS with the new interface showed strong potential for the determination of low abundance analytes. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
The fabrication of a novel sheathless interface for capillary electrophoresis–electrospray–mass spectrometry (CE–ESI–MS) is described. A programmable CO2 laser was used to ablate small channels in the walls of a polyimide capillary near the terminus. Subsequent exposure of the channel region to a cellulose acetate solution followed by drying resulted in the formation of an electrically conductive semi-permeable membrane. Application of an appropriate voltage to the reservoir resulted in the simultaneous establishment of an electrical connection for CE and ESI. Interface viability was demonstrated by conducting a CE separation of a peptide mixture, with detection accomplished via positive ion mode ESI–MS. For the peptide Val-Tyr-Val, a limit of detection of 0.1 femtomole (S/N 3) was achieved using single reaction monitoring. Attributes of the interface include structural robustness, ease of fabrication, minimal interface dead volume, and the ability to alter post-separation analyte ionization status by use of appropriate buffers in the interface reservoir.  相似文献   

10.
The construction of a sheathless interface for capillary electrophoresis-electrospray ionization mass spectrometry (CE-ESI-MS), for operation with a Z-Spray source on a Micromass Quattro-LC triple quadrupole mass spectrometer is described. Designing the interface involved machining a probe compatible with the setup already in place on the mass spectrometer, i.e., MegaFlow-Z ESI. The probe was made of Lexan with the same dimensions as the ESI probe supplied with the instrument. The electrical connection at the electrospray end of the CE capillary was made possible by gold-coating (sheathless CE-ESI-MS). The probe design as well as the electrical and power supply requirements are described in detail. Experiments were performed using this interface, and CE separations of mixtures containing pmole and sub-pmole amounts of peptides were monitored by on-line MS. For a standard peptide mixture (10(-4) M), separation efficiency was typically characterized by N > 10(4) theoretical plates with S/N > 400. Using the same experimental setup, it was also possible to conduct on-line CE-ESI-tandem MS (MS/MS) experiments on the same peptide mixture, and to determine the sequence of the peptides. MS/MS scan functions for different precursor ions were used either alternately or sequentially and the results from both methods were compared. The possibility of peptide mass mapping was explored, and CE-ESI-MS results were obtained for the digestion products of equine myoglobin. Separation efficiencies and S/N values were similar to those obtained for standard peptides. A complete map of the digestion products was obtained.  相似文献   

11.
An earlier developed capillary electrophoresis (CE) system with an on-capillary adsorptive phase is investigated for its suitability to quantitate low concentrations of angiotensin II and gonadorelin in plasma. An off-line solid-phase extraction is used for sample preparation. The on-line preconcentration CE system allows multiple capillary volumes of sample solution to be injected, increasing the concentration sensitivity of CE with 3-4 orders of magnitude. Furthermore, possible influence of matrix salts can be ruled out by employing a rinsing step after sample application. Using short-wavelength UV detection, reproducibility and linearity in the low nanomolar range were satisfactory. The capillary could be efficiently regenerated using a programmed between-run rinsing procedure, allowing 20-30 large injections of sample extracts. Coating of the capillary improved the robustness of the method. Mass spectrometric detection via a previously reported sheathless interface increased the selectivity and sensitivity substantially. Recommendations are provided for the sample preparation process, the most critical part of the system. Further purification of the sample is required to allow the loading of larger sample volumes and to optimize the system's robustness.  相似文献   

12.
A novel method for electrophoretic mobility-assisted identifications of proteins, using capillary electrophoresis/mass spectrometry (CE/MS) under methanolic conditions, was developed. The number of functional groups of the enzymatic digest peptides was estimated from a single run CE/MS analysis and utilized as an additional tag for database searching in addition to the mass map of the peptides. The additional amino acid information thus obtained can improve the confidence level of the protein identification. The database searching software algorithm ProFound was modified to accept the tag, based on this new concept. In this study, optimization of the CE/MS conditions for the estimation of basic functional groups was performed as an example. An accurate value of the number of such functional groups was obtained from CE characteristics when methanolic buffer (methanol/formic acid/water = 60:20:20) was used, via an excellent correlation (r = 0.997) between the number of functional groups of the peptides and [MW((2/3))]. The mass spectrometry sensitivity was also improved when using the methanolic buffer in comparison with that obtained using aqueous 1% formic acid buffer. The identification of a protein of Saccharomyces cerevisiae, which was separated by two-dimensional electrophoresis, was performed using the methanolic buffer in combination with sheathless nanoelectrospray CE/MS. A protein spot that had not been identified by MALDI-TOFMS and LC/MS/MS was successfully identified using this new method.  相似文献   

13.
Chao BF  Chen CJ  Li FA  Her GR 《Electrophoresis》2006,27(11):2083-2090
A sheathless interface has been developed for coupling CE with electrospray IT mass spectrometer. This interface utilized a pulsed ESI source. The use of a pulsed electrospray source allows the use of a sprayer with larger orifice, and thus alleviates the problem of column clogging during conductive coating and CE analysis. A pulsed ESI source operated at 20 Hz and 20% duty cycle was found to produce the optimal signals. For better signals, the maximum ion injection time in the IT mass spectrometer has to be set to a value close to the actual spraying time (10 ms). Using a sprayer with 50 microm od, more stable and enhanced signals were obtained in comparison with continuous CE-ESI-MS under the same flow rate (150 nL/min). The utility of this design is demonstrated with the analysis of synthetic drugs by CE-MS.  相似文献   

14.
A sturdy home-built sheathless CE/ESI-QTOF-MS system was developed and optimized for carbohydrate analysis. The interface and employed methodology provided a simple analytical solution to laborious CE/MS interfacing methods and to problems in characterization of complex carbohydrate mixtures that require high-resolution separation of the components. The CE/ESI interface, feasible in any MS laboratory, consists of a one-piece CE column having the CE terminus in-laboratory shaped as a microsprayer and coated with copper. The CE microsprayer was inserted into an in-house made stainless steel clenching device and the whole assembly was mounted onto a quadrupole TOF mass spectrometer. The analytical potential of the interface in terms of suitability, microsprayer performance, copper coat durability, ionization efficiency, spray stability, and sensitivity was tested first on a simple mixture of standard saccharides, which were separated, resolved, and detected with high separation efficiency. The approach was next assessed for the screening of a biological sample, a complex mixture of O-glycosylated sialylated amino acids from urine of a patient suffering from Schindler disease. Preliminary data allow this method to be considered as one of general applicability in structural glycobiology and glycomics and easy to be implemented for proteomic surveys as well.  相似文献   

15.
In this work we explored the feasibility of different CE-ESI-MS set-ups for the analysis of conformational states of an intact protein. By using the same background electrolyte at quasi physiological conditions (50 mM ammonium bicarbonate, pH 7.4) a sequential optimization was carried out, initially by evaluating a sheath-liquid interface with both a single quadrupole (SQ) and a time-of-flight (TOF) mass spectrometer; then a sheathless interface coupled with high-resolution QTOF MS was considered. Beta2-microglobulin has been taken as a model, as it is an amyloidogenic protein and its conformational changes are strictly connected to the onset of a disease. The separation of two conformers at dynamic equilibrium is achieved all the way down to the MS detection. Notably, the equilibrium ratio of the protein conformers is maintained in the electrospray source after CE separation. Strengths and weaknesses of each optimized set-up are emphasized and their feasibility in unfolding studies is evaluated. In particular, ESI-TOF MS can assign protein forms that differ by 1 Da only and sheathless interfacing is best suited to preserve protein structure integrity. This demonstrates the CE-ESI-MS performance in terms of separation, detection and characterization of conformational species that co-populate a protein solution.  相似文献   

16.
A simple laboratory-made sheathless electrospray interface for coupling of capillary electrophoresis to ion-trap mass spectrometry (CE/MS) was developed. The interface was machined in-house and it was designed to be freely interchangeable with the commercially available ionization sources for the mass spectrometer. Sharpened fused-silica capillaries were coated with nickel by a simple electrodeless plating procedure and were used as all-in-one columns/emitters. The electrodeless plating produced a 2-5- micro m thick smooth nickel layer that lasted for more than 8 h of continuous electrospraying. The performance of the CE/MS interface was examined by using four cationic imipramine derivatives as test substances. Relative detection limits were calculated on the basis of the extracted ion electrophorograms and were in the range 6-130 nmol/L, corresponding to absolute detection limits in the range of 20-400 amol. The system was applied for analysis of impurities in an impure imipramine N-oxide preparation, and two of the impurities could be identified on the basis of online-MS(MS) spectra recorded in scan-dependent mode.  相似文献   

17.
《Electrophoresis》2018,39(11):1382-1389
A sheath‐flow interface is the most common ionization technique in CE‐ESI‐MS. However, this interface dilutes the analytes with the sheath liquid and decreases the sensitivity. In this study, we developed a sheathless CE‐MS interface to improve sensitivity. The interface was fabricated by making a small crack approximately 2 cm from the end of a capillary column fixed on a plastic plate, and then covering the crack with a dialysis membrane to prevent metabolite loss during separation. A voltage for CE separation was applied between the capillary inlet and the buffer reservoir. Under optimum conditions, 52 cationic metabolite standards were separated and selectively detected using MS. With a pressure injection of 5 kPa for 15 s (ca. 1.4 nL), the detection limits for the tested compounds were between 0.06 and 1.7 μmol/L (S/N = 3). The method was applied to analysis of cationic metabolites extracted from a small number (12 000) of cancer cells, and the number of peaks detected was about 2.5 times higher than when using conventional sheath‐flow CE‐MS. Because the interface is easy to construct, it is cost‐effective and can be adapted to any commercially available capillaries. This method is a powerful new tool for highly sensitive CE‐MS‐based metabolomic analysis.  相似文献   

18.
When optimizing a capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) system, consideration has to be given not only to the separation but also to the electrospray stability. Methods developed for CE/UV analysis of drugs and peptides were considered and modified to be suitable for a CE/MS system with a robust sheathless interface. Different concentrations of the organic modifiers acetonitrile, methanol and 2-propanol were used in the separation buffer. The type and concentrations of these modifiers were also compared with reference to electrospray stability, sensitivity and time of analysis. In addition, different ionic strengths in the buffers were evaluated with reference to electrospray stability. The repeatability was used for the estimation of electrospray stability. The degree to which these parameters influenced the separation and the ESI stability was studied using a nine-peptide standard mixture and the antibiotic drugs bacampicillin and ampicillin as test substances. The analysis time and resolution were used as measures of the efficiency of the separation. A time-of-flight MS analyzer was used since it has the potential advantages of becoming a better fit for integration of CE with MS owing to the speed and sensitivity of this mass analyzer. The detection limit, i.e. 1 microM, for bacampicillin was comparable to what could be achieved with CE/MS on a quadrupole instrument using selected ion monitoring and sheath flow ESI.  相似文献   

19.
A sheathless and electrodeless nanospray interface has been used to interface a polycarbonate capillary electrophoresis (CE) chip to a mass spectrometer (MS). The chip was made of two flat polycarbonate plates which were bolted together. Channels were imprinted in one of the plates with metal wires, using a hydraulic press. A short tapered capillary connected to the chip was used as the nanospray emitter. The advantage of this electrodeless interface is that it was not necessary to apply a electrospray voltage to the chip or the nanospray emitter. Instead, the CE voltage already applied to the buffer compartment on the chip, to drive the electrophoresis, was used to generate the spray also. A low conductivity buffer of 1.25 mmol/L ammonium acetate in 80% methanol was used to obtain a large electric field across the buffer channel. The performance of the device was evaluated by analyzing a mixture of three beta-agonists Relative standard deviation (RSD) values obtained were between 4.8 and 5.0%. A sample concentration of 40 nmol/L resulted in a signal-to-noise ratio of 2 to 5 for the different components. Compared to a conventional CE analysis in a fused silica capillary with UV detection, only a minor loss of resolution was observed, which can be attributed to the design of the chip.  相似文献   

20.
Parathyroid hormone (PTH) is a common clinical marker whose quantification relies on immunoassays, giving variable results as batch, brand, or target epitope changes. Sheathless CE‐ESI‐MS, combining CE resolution power and low‐flow ESI sensitivity, was applied to the analysis of PTH in its native conformation in the presence of related forms. Fused silica and neutral‐coated capillaries were investigated, as well as preconcentration methods such as transient isotachophoresis, field‐amplified sample injection (FASI), and electrokinetic supercharging (EKS). The method for the separation of PTH and its variants was first developed using fused‐silica capillary with UV detection. An acidic BGE was used to separate 1–84 PTH (full length), 7–84 PTH, and 1–34 PTH. Acetonitrile was added to the BGE to reduce peptide adsorption onto the capillary wall and transient isotachophoresis was used as analyte preconcentration method. The method was then transferred to a sheathless CE‐ESI‐MS instrument. When using a fused silica capillary, CE‐MS was limited to μg/mL levels. The use of a neutral coating combined with FASI or EKS allowed a significant increase in sensitivity. Under these conditions, 1–84 PTH, 7–84 PTH, and 1–34 PTH were detected at concentrations in the low ng/mL (FASI) or pg/mL (EKS) range.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号