首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
This paper presented the applications of liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) and ultra-high-pressure liquid chromatography electrospray ionization quadrupole time-of-flight mass spectrometry (UHPLC QqTOF MS) for the determination of 148 pesticides in fruits and vegetables. Pesticides were extracted from fruits and vegetables using a buffered QuEChERS method. Quantification was achieved using matrix-matched standard calibration curves with isotopically labeled standards or a chemical analog as internal standards in an analytical range from 5 to 500 μg/kg. The method performance parameters including overall recovery, intermediate precision, and measurement uncertainty were evaluated according to a statistically designed experiment, i.e., a nested design. For LC/ESI-MS/MS, 95% of the pesticides had recoveries between 81% and 110%; 97% had an intermediate precision ≤20%; and 95% (in fruits) or 93% (in vegetables) showed measurement uncertainty ≤40%. Compared to LC/ESI-MS/MS, UHPLC QqTOF MS showed a relatively poor repeatability and large measurement uncertainty. About 93% (in fruits) or 94% (in vegetables) of the pesticides had recoveries between 81% and 110%; 86% (in fruits) or 90% (in vegetables) had an intermediate precision ≤20%; and 79% (in fruits) or 88% (in vegetables) showed measurement uncertainty ≤40%. LC/ESI-MS/MS proved to be the first choice for quantification or pre-target analysis due to its superior sensitivity and good repeatability. UHPLC QqTOF MS provided accurate mass measurement and isotopic patterns, and was an ideal tool for post-target screening and confirmation.  相似文献   

2.
A liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated to determine 90 pesticides in apple samples. MS/MS data acquisition was achieved by applying multiple-reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Matrix-matched standard calibration curves with the use of isotopically labeled standards (or a chemical analog) as internal standards were used to achieve the best accuracy for the method. Both a conventional method validation procedure and a designed experiment were applied to study the accuracy and precision of the method. A compiled computer program that provided a semiautomated procedure for handling a large number of calculations was used to calculate the overall recovery, intermediate precision, and measurement uncertainty (MU). In general, the overall recoveries from samples spiked at levels of 10, 50, and 80 microg/kg, ranged from 60.8 to 121.1%, intermediate precision was <10%, and MUs were <30%. Poor accuracy and/or repeatability was observed for pyridate and etofenprox. The method limits of detection based on a signal-to-noise ratio of >3 were usually <1 microg/kg (ppb), except those for aldicarb sulfoxide and pyridaphenthion, which were about 5 microg/kg.  相似文献   

3.
In this work, 53 selected pesticides of different chemical groups were extracted from Chinese herbal medicines and determined by ultra-high-performance liquid chromatography (UHPLC)–tandem mass spectrometry (MS/MS) using both electrospray ionization (ESI) and atmospheric-pressure chemical ionization (APCI). Extracts were obtained using the acetonitrile-based quick, easy, cheap, effective, rugged, and safe (QuEChERS) sample preparation technique. Cleanup was performed by dispersive solid-phase extraction using primary secondary amine, graphitized carbon black, and octadecylsilane. Two atmospheric-pressure interfaces, ESI and APCI, were checked and compared. The validation study, including detection limits, linearity, and matrix effects, was conducted on fritillaria, radix ginseng, folium isatidis, semen persicae, and flos lonicerae in multiple reaction monitoring mode. These matrices represent a variety of plants used in traditional Chinese medicine. Fritillaria and radix ginseng were chosen as representatives for roots, folium isatidis was chosen as a representative for leaves, semen persicae was chosen as a representative for seeds, and flos lonicerae was chosen as a representative for flowers. The limits of detection for pesticides were lower in the UHPLC–ESI-MS/MS method than in the UHPLC–APCI-MS/MS method. Matrix effects on the two ionizations were evaluated for the five matrices. Soft signal enhancement in UHPLC–APCI-MS/MS and signal suppression in UHPLC–ESI-MS/MS were observed.
Figure
Overview of UPLC–MS/MS assay for comparing the APCI and ESI interfaces  相似文献   

4.
The potential of liquid chromatography combined with tandem mass spectrometry (LC/MS/MS) for the determination of pesticide metabolites in human urine at the sub-ppb level is explored. Metabolites from two organophosphorous pesticides, 4-nitrophenol (from parathion and parathion-methyl) and 3-methyl-4-nitrophenol (from fenitrothion), are taken as model analytes to conduct this study. After direct injection of the urine sample (10 microL), different approaches were evaluated in order to achieve correct quantitation of analytes using an electrospray ionisation (ESI) interface. Thus, the feasibility of using external calibration was checked versus the use of different isotope-labeled internal standards. The advantages of applying coupled-column liquid chromatography (LC/LC) as an efficient clean-up without any type of sample manipulation are also discussed. The combination of LC/LC with ESI-MS/MS allows the direct analysis of free metabolites in urine, as the automated clean-up performed by the coupled-column technique is sufficient for the removal of interferences that suppress the ionisation of analytes in the ESI source. Using this procedure with external calibration, good precision and recoveries, and detection limits below 1 ng/mL are reached with analysis run times of around 8 min. The hyphenated technique LC/LC/ESI-MS/MS is proved to be a powerful analytical tool, allowing the rapid, sensitive and selective determination of 4-nitrophenol and 3-methyl-4-nitrophenol in human urine without any sample treatment.  相似文献   

5.
A sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the quantitative determination of ochratoxin A (OTA) in kidney samples was developed. Ochratoxin B (OTB) was used as internal standard. Extraction of homogenized kidney samples was done by adding a chloroform/phosphoric acid mixture. Due to restriction of the sample size, less chloroform could be used than in previously described methods. Two different columns for clean-up were compared: strong anion exchange (Bond Elut SAX) and Extrelut NT columns. The high-performance liquid chromatography (HPLC) was used with gradient elution consisting of variable mixtures of formic acid (0.3%) in acetonitrile and formic acid (0.3%) in water. The mass spectrometer was operated in the positive ESI mode using multiple reaction monitoring. For OTA the precursor ion was m/z 404 while the product ions were at m/z 239 and m/z 341. For OTB the precursor ion was m/z 370 while the product ions were at m/z 205 and at m/z 324. A calibration curve of fortified kidney samples was used to quantify OTA. Method validation was performed according to Commission Decision 2002/657/EC. Decision limit (CCalpha), detection capability (CCbeta), precision, bias, trueness, specificity and measurement uncertainty were determined. In general, the best results were obtained using SAX clean-up. CCalpha and CCbeta were 0.11 and 0.25 microg kg(-1), respectively. Within-laboratory reproducibility (% CV) was 9, 9, and 5% for OTA-fortified kidney samples of 0.5, 1, and 2.5 microg kg(-1), respectively. Trueness (%) was 75, 69, and 57% for OTA-fortified kidney samples at 0.25, 0.5, and 1 microg kg(-1), respectively. Measurement uncertainty and expanded uncertainty were 14.85 and 29.70%, respectively. All criteria as laid down in Commission Decision 2002/657/EC were fulfilled. Therefore, this LC/ESI-MS/MS method can be used to monitor kidneys for OTA in the framework of Council Directive No. 96/23/EC.  相似文献   

6.
A method was developed for screening crops for a range of pesticide residues by liquid chromatography/tandem mass spectrometry (LC/MS/MS). A complete set of LC, electrospray ionization (ESI), and tandem MS acquisition parameters was established for the determination of 108 analytes; these parameters were used for the simultaneous acquisition of 98 analytes in the positive ESI mode and 10 analytes in an additional MS/MS method in the negative ESI mode. The entire procedure involves extraction of residues with methanol-water and partition into dichloromethane. The utility of the method is demonstrated by the analysis of crops of 5 matrix types (water-containing, acidic, dry, sugar-containing, and fatty). Of 108 pesticides/metabolites tested, 104 showed sufficient stability in most matrixes for determination by LC/MS/MS. These analytes belong to 20 chemical classes, which demonstrate the general applicability of the method for multiclass analysis. By using matrix-matched standards, 67 compounds could be determined in most matrixes with recoveries of 70-120% and a relative standard deviation of < or = 25% at the 0.01 mg/kg level.  相似文献   

7.
胡贝贞  蔡海江  宋伟华 《色谱》2012,30(9):889-895
建立了茶叶中氟虫腈、吡虫啉、啶虫脒、噻嗪酮、三唑酮、三唑醇、丙溴磷、哒螨酮共8种农药残留的液相色谱-串联质谱(HPLC-MS/MS)测定方法。样品用丙酮-二氯甲烷(1:1, v/v)混合溶剂加速溶剂提取,经石墨化炭黑/氨基(Carb/NH2)固相萃取小柱净化,采用Hypersil Gold C18色谱柱(150 mm×2.1 mm, 5 μm)分离,以乙腈-0.1%甲酸水溶液为流动相梯度洗脱,以电喷雾电离(ESI)、多反应监测(MRM)模式检测,采用基质标准曲线同位素内标法(吡虫啉、啶虫脒)或外标法(其余6种农药)定量。氟虫腈在1~100 μg/L、其余7种农药在5~200 μg/L范围内线性关系良好,方法的定量限(信噪比大于10)为氟虫腈2 μg/kg、其余7种农药10 μg/kg。氟虫腈在2、5、50 μg/kg、其余7种农药在10、50、100 μg/kg加标水平下的回收率为75.5%~115.0%,相对标准偏差为2.7%~7.7%。另外,按照JJF 1059-1999《测定不确定度评定与表示》中的有关规定,从标准溶液、样品称量、标准曲线、样品定容、仪器测定重复性、样品前处理等方面对测定结果的不确定度来源进行了评定。评定结果显示,测定结果的不确定度主要源于样品前处理、标准曲线及仪器测定的重复性。该方法的提取效果好、净化较彻底,灵敏度满足国外限量标准的要求,适合出口茶叶中农药残留的测定。  相似文献   

8.
This paper describes a method for the sensitive and selective determination of two macrocyclic lactones (abamectin and spinosad) and azadirachtin in apple purée, concentrated lemon juice, tomato purée and canned peas. The general sample extraction-partitioning method for our gas chromatography and liquid chromatography multiresidue methods has been used. The analytical procedure involves an extraction with acetone and liquid-liquid partitioning with ethyl acetate/cyclohexane combined in one step. The extracts are analyzed by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) without any further clean-up step. The pesticides are separated on a reversed-phase C12 column using a gradient elution. Thirteen simultaneous MS/MS transitions of precursor ions were monitored. Studies at fortification levels of 2.5-10 microg/kg and 25-100 microg/kg gave mean recoveries ranging from 70-100% for all compounds with satisfactory precision (relative standard deviation (RSD) from 3-20%). The excellent selectivity and sensitivity allows quantification and identification of low levels of pesticides in canned peas, tomato and apple purées (limits of quantitation (LOQs) 1-5 microg/kg) and in concentrated lemon juice (LOQs 2-10 microg/kg). The quantification of analytes was carried out using the most sensitive transition for every compound and by 'matrix-matched' standards calibration.  相似文献   

9.
A simple liquid chromatography/mass spectrometry (LC/MS) approach for the determination of widely used representatives of polar/thermolabile pesticides in fruits was developed and validated. The group of pesticides comprised benzimidazoles and azoles (carbendazim, thiabendazole, imazalil, propiconazole, prochloraz, epoxiconazole, flusilazole, tebuconazole, bitertanol); N-methylcarbamates (carbaryl, carbofuran, methiocarb); and phenylureas and benzoylphenylureas (linuron, diflubenzuron, triflumuron, teflubenzuron, flufenoxuron). Matrixes (apple, apricot) were extracted with acetonitrile and crude extracts were cleaned up by solid-phase extraction (SPE) using either mixed cation exchange or hydrophilic lipophilic balance cartridges. LC separation of pesticides was performed on a reversed-phase column, Discovery C18. Electrospray ionization and ion trap MS/MS detection were applied. For most pesticides, overall recoveries ranged from 75 to 122%, and repeatability (as relative standard deviation) from 5 repetitive determinations of recovery ranged from 3 to 21%. Carbofuran was the only compound for which recovery was not satisfactory due to its loss in the SPE cleanup step. Limits of detection were 0.1-3 microg/kg for benzimidazole and azole fungicides and carbamate insecticides. For urea insecticides, detection limits were slightly higher (3-10 microg/kg).  相似文献   

10.
A simple confirmatory method for the determination of spiramycin and its metabolite neospiramycin in raw milk using LC ESI MS/MS is presented. Macrolide residues in raw milk were extracted by ACN, and sample extracts were further cleaned up and concentrated using SPE cartridges. Both spiramycin and neospiramycin were protonated in electrospray positive ion mode to form singly and/or doubly charged pseudomolecular ions. Data acquisition was achieved using multiple reaction monitoring, i.e., two transitions, for quantification and confirmation. Matrix‐matched standard calibration curves were utilized to achieve the best accuracy for the method. The method performance was evaluated according to both a conventional validation procedure and a designed experimental result. The measurement uncertainty arising from accuracy and precision was estimated. The method accuracy, expressed as a percentage of an overall recovery, was from 82.1 to 108.8%, and its intermediate precision was less than 20%. LC/ESI‐MS/MS method LODs (S/N ? 3:1) of spiramycin and neospiramycin were less than 1.0 μg/kg.  相似文献   

11.
In this report, electrospray ionization tandem mass spectrometry (ESI-MS/MS) for a pharmacokinetic study of IDN 5390, a novel C-seco taxane derivative, which is under preclinical evaluation, has been investigated. Our results showed that IDN 5390 and other taxanes including paclitaxel and IDN 5109 could ionize well in not only positive-, but also in negative-ion mode. Under collision-induced dissociation (CID) conditions, these compounds could fragment into similar M- (molecular), T- (taxane ring) and S- (side chain) series ions. In positive-ion ESI, the formation of both T- and S-series ions involved the breaking of the C-13 ester bond. In negative-ion ESI, however, while the formation mechanism of S-series ions remained the same, the breaking of the C-1' carboxylic ester bond resulted in T-series ions. At optimum collision energy (CE) values, M-, T- and S-series ions of IDN 5390 in both positive- and negative-ion ESI-MS/MS spectra had good intensity. This phenomenon makes both positive- and negative-ion ESI-MS/MS good methods for IDN 5390 metabolite structural characterization, i.e. to reveal the location of modification groups in IDN 5390 metabolites versus IDN 5390 either on the side chain or the taxane ring. A liquid chromatography (LC)/ESI-MS/MS method using the multiple-reaction monitoring (MRM) technique was thereafter developed to quantify IDN 5390 in dog plasma using paclitaxel as internal standard. The method was validated using a concentration range between 5 and 1000 ng/mL and had a limit of detection of 1 ng/mL. The inter-day %CV (%coefficient of variation) of the calibration standards ranged between 4.36 and 9.64%, the intra-day %CV of the calibration standards between 0.61 and 13.44%, and the mean % accuracy of the quality control samples at the low, middle and high end of the concentration curves were 12.5, 6.8 and 9.6%, respectively.  相似文献   

12.
A rapid method is presented for the determination of 4 nitroimidazoles in poultry and swine muscle and eggs by liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS). Samples were extracted with acetonitrile, then evaporated the organic phase. After filtration, the extract was directly injected into the LC/ESI-MS/MS system. The LC separation was made on a C8 column by applying a gradient composed of water and acetonitrile. Overall average recoveries ranged from 50-86% for egg, 66-115% for poultry muscle, and 79-111% for swine muscle. The decision limits ranged from 0.05-0.25 microg/kg for egg, 0.07-0.27 microg/kg for poultry muscle, and 0.07-0.26 microg/kg for swine muscle; and detection capabilities ranged from 0.51-0.68 microg/kg for egg, 0.41-0.75 microg/kg for poultry muscle, and 0.53-0.78 microg/kg for swine muscle.  相似文献   

13.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

14.
A sensitive method using liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was developed and validated to quantify and confirm 13 pesticides, including aldicarb sulfoxide, aldicarb sulfone, oxamyl, methomyl, formetanate, 3-hydroxycarbofuran, carbendazim, thiabendazole, aldicarb, propoxur, carbofuran, carbaryl, and methiocarb, in soy-based infant formula. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Different approaches to constructing calibration curves were compared and discussed to address issues of the extraction efficiency or recovery, and matrix effects. Matrix-matched standard calibration curves with the use of isoprocarb as an internal standard were finally used to achieve the best accuracy of the method. Under most circumstances, recoveries of 13 pesticides, spiked at 5.0, 25.0, and 45.0 microg/kg, were close to 100%. The method detection limits (signal-to-noise ratio > or =3:1; microg/kg) of 13 pesticides were 0.2 for thiabendazole and methiocarb, 0.6 for aldicarb, and 0.1 for the others.  相似文献   

15.
An analytical method based on ultrasound assisted extraction (UAE) and liquid chromatography coupled to electrospray tandem mass spectrometry (LC–ESI/MS/MS) was validated and applied for determining L-dopa in four ecotypes of Fagioli di Sarconi beans (Phaseolus vulgaris L.), marked with the European label PGI (Protected Geographical Indication). The selectivity of the proposed method was ensured by the specific fragmentation of the analyte. Simple isocratic chromatographic conditions and mass spectrometric detection in multiple reaction monitoring (MRM) acquisition mode were used for sensitive quantification. The LC–ESI/MS/MS method was validated within a linear range of 0.001–5.000 μg/mL. Values of 0.4 and 1.1 ng/mL were obtained for the limits of detection and quantification, respectively. The repeatability, inter-day precision, and recovery values ranges were 0.6%–4.5%, 5.4%–9.9%, and 83%–93%, respectively. Fresh and dried beans, as well as pods, cultivated exclusively with organic methods avoiding any synthetic fertilizers and pesticides were analyzed showing an L-dopa content ranging from 0.020 ± 0.005 to 2.34 ± 0.05 μg/g dry weight.  相似文献   

16.
A sensitive liquid chromatography/electrospray ionisation tandem mass spectrometric (LC/ESI-MS/MS) method was developed for the analysis of acetylcholine and choline in microdialysis samples. A Ringer's solution that contains high (150 mM) concentrations of inorganic salts was used to extract acetylcholine and choline from a rat or mouse brain. The separation of acetylcholine, choline, an internal standard acetyl-beta-methylcholine, endogenous compounds and inorganic cations was achieved with hydrophilic interaction chromatography using a diol column. The eluent consisted of 20 mM ammonium formate (pH 3.3) and acetonitrile (20:80) which is favourable for the ESI process. Limits of detection (signal-to-noise (S/N) ratio = 3) of 0.02 nM (0.2 fmol) for acetylcholine and 1 nM (10 fmol) for choline were observed using standards diluted in Ringer's solution. A good linearity was obtained from the limit of quantitation: 0.1 nM (S/N ratio = 10) to 50 nM (r = 0.999) for acetylcholine and within the concentration range of 100-3500 nM (r = 0.998) for choline. The between-day repeatability of the method was good; RSD was 3.1% at 1 nM level of acetylcholine and 3.5% at 1000 nM level of choline. The recoveries for addition of 1 or 2.5 nM acetylcholine and 0.2 or 1 microM choline in microdialysis balancing samples were between 93 and 101% indicating that no suppressing endogenous compounds were co-eluting with acetylcholine or choline. The developed method was applied to the analysis of microdialysis balancing samples collected from rat and mouse brains.  相似文献   

17.
An efficient and sensitive method has been established for simultaneous determination of 653 pesticides in teas by GC/MS and HPLC/MS/MS. The method involved extraction with acetonitrile followed by cleanup using Cleanert-TPT SPE and subsequent identification and quantitation of 490 pesticides by GC/MS and 448 pesticides by HPLC/MS/ MS. The LODs for pesticides determined by GC/MS were between 1.0 and 500 microg/kg, and those determined by HPLC/MS/MS were between 0.03 and 4820 microg/kg. At the low fortification levels of 0.01-100 microg/kg, the average recoveries of 94% of the pesticides determined by GC/MS were between 60 and 120%, 77% of which had an RSD below 20%. For 91% of pesticides determined by HPLC/MS/MS, the average recoveries were between 60 and 120%, 76% of which had an RSD below 20%. The paper also reports a novel SPE column, Cleanert TPT, which comprised graphitized carbon black (PestiCarb), polyamine silica, and amide polystyrene for purifying the tea samples. The results indicated good repeatiblity and reproducibility.  相似文献   

18.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   

19.
The feasibility of using liquid chromatography/ electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) for determining 2 fungicides (fludioxonil and famoxadone) in tomato pulp, pear purée, and concentrated lemon juice has been evaluated. A miniaturized extraction-partition procedure requiring small amounts of nonchlorinated solvents was used. The extracts (5 microL) were analyzed by LC/ESI-MS/MS without previous cleanup. Chromatographic determination was performed using a C18 column with isocratic elution. Four MS/MS transitions of precursor ions were monitored simultaneously (2 for each pesticide) by means of negative ESI. Mean recoveries from samples at fortification levels of 0.002-0.020 mg/kg (fludioxonil) and 0.010-0.100 mg/kg (famoxadone) ranged from 77.1 to 96.5%, with associated relative standard deviations between 4.2 and 11.5%.  相似文献   

20.
Measurement uncertainty although introduced to medical laboratories some years ago, this concept is not familiar to all medical researchers, especially for the measurement of biological samples. Therefore, it is important to highlight the evaluation and expression of measurement uncertainty using a practical example. In accordance with published procedures for evaluating and expressing uncertainty, we analyzed the sources of uncertainty in the determination of repaglinide in human plasma using liquid chromatography–tandem mass spectrometry (LC–MS/MS). We investigated each component of uncertainty and calculated the combined and expanded uncertainties. We evaluated the uncertainty associated with repeatability, weighing, purity, solution and sample preparation, recovery, calibration fitting, and temperature. The expanded uncertainty for low, medium, and high concentrations of repaglinide was 0.090, 0.25, and 3.16 ng/mL, respectively (p = 95 %, k = 2). This example provides an important reference for the evaluation of uncertainty in biological sample determinations using LC–MS/MS and human plasma and will be helpful in explaining the reliability of test results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号