共查询到20条相似文献,搜索用时 15 毫秒
1.
A liquid chromatography/mass spectrometry (LC/MS) method for the determination of carbonyl compounds based on derivatization with N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH) has been developed. Atmospheric pressure chemical ionization (APCI) in the positive mode proved the most versatile ionization technique for MNBD-hydrazones. APCI/MS spectra were recorded and the detection limits were determined for [M+H]+, 13C2 acetaldehyde MNBD-hydrazone has been synthesized and characterized. It is applied as internal standard for the quantification of acetaldehyde. Tobacco smoke has been investigated concerning its carbonyl content. Acetaldehyde was identified as main product and quantified by LC/MS using internal standardization. The result is in good agreement to quantification data obtained with UV/vis detection. 相似文献
2.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL). 相似文献
3.
An analytical procedure was developed for the determination of some natural pesticides (piperonyl butoxide, nicotine, rotenone, spinosad, and abamectin B1a) in fruit matrixes. The quick, easy, cheap, effective, rugged, and safe (QuEChERS) method was used for extraction. Analysis of the extract was performed by LC-electrospray ionization (ESI)-MS/MS. The ions prominent in the ESI spectra were [M+Na]+ for abamectin B1a, [M+NH4]+ for piperonyl butoxide, and [M+H]+ for the rest of the compounds. A Zorbax SB-C18 column was used with a programmed gradient mobile phase consisting of (A) water containing 0.1% formic acid and 5 mM ammonium formate, and (B) acetonitrile containing 2 mM sodium acetate. The method was linear within the investigated concentration range, displaying a calibration curve correlation factor of 0.99. The CVs obtained were below 20%, and recoveries were in the 70-110% range. 相似文献
4.
Yee-Chung Ma Hee-Yong Kim 《Journal of the American Society for Mass Spectrometry》1997,8(9):1010-1020
On-line atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) liquid chromatography/mass spectrometry (LC/MS) were evaluated for the analysis of a variety of steroids. Steroids were classified into three major groups based on the spectra and the sensitivities observed: (I) those containing a 3-one, 4-ene functional group, (II) those containing at least one ketone group without conjugation, and (III) those containing hydroxy group(s) only. In the APCI mode, the best sensitivity and the lowest detection limit for all three groups were obtained by using a mobile phase consisting of methanol and 1%–2% acetic acid in water. The APCI spectra were characterized by MH+, MH+-H2O, MH+-2H2O, etc., with the degree of H2O loss being compound dependent: group I steroids produced stable MH+ and group III steroids showed extensive water loss. In the electrospray mode the best sensitivity and the lowest detection limit for the first two groups were obtained when pure methanol and water were used as the mobile phase. This condition produced abundant stable MNa+ due to ubiquitous sodium. Detection limits in the 5–15 pg range can be easily achieved using ESI LC/MS. Addition of ammonium acetate or use of acetonitrile in the mobile phase, common in the LC/MS analysis of steroids, decreased the sensitivity for the group I and II steroids and thus should be avoided. For group III steroids, the detection limit can be improved by the addition of acetic acid to the mobile phase. 相似文献
5.
Determination of formaldehyde and acetaldehyde in mainstream cigarette smoke by high-performance liquid chromatography 总被引:6,自引:0,他引:6
A method is described for the determination of formaldehyde and acetaldehyde in mainstream cigarette smoke. This involved the collection and reaction of the aldehydes with 2,4-dinitrophenylhydrazine in aqueous acetonitrile. The high-performance liquid chromatographic separation and measurement of the various components directly in this reaction solution eliminated the need for a clean-up stage. Cigarette yields of greater than 5 micrograms of formaldehyde and 50 micrograms of acetaldehyde could be determined to estimated relative standard deviations of 0.07 and 0.05, respectively. 相似文献
6.
研究建立了血清中尿素测定的新方法,以尿素同位素标记物(Urea-13C,15N2)为内标,样品用乙腈沉淀蛋白。以ZORBAXRX-SIL色谱分离柱,V(乙腈):V(水)=95:5为流动相,使用电喷雾三重四极杆串联质谱的多重反应监测模式(Multiple Reaction Monitoring,MRM)测定,以及同位素稀释的括号法进行定量。所建立的液相色谱同位素稀释串联质谱法(ID-LCMS/MS)对于分析血清尿素的批内、批间RSD分别为0.21%~0.85%、0.05%~0.38%,回收率为97.9%~102.3%,采用美国国家标准和技术研究院(NIST)的血清标准物质SRM909b进行了方法确证,测定结果与标准值的相对偏差小于0.5%且在其定值范围内。 相似文献
7.
Determination of azaspiracids in shellfish using liquid chromatography/tandem electrospray mass spectrometry. 总被引:3,自引:0,他引:3
Ambrose Furey Ana Bra?a-Magdalena Mary Lehane Cian Moroney Kevin J James Masayuki Satake Takeshi Yasumoto 《Rapid communications in mass spectrometry : RCM》2002,16(3):238-242
Azaspiracid (AZA1), a recently discovered marine toxin, is responsible for the new human toxic syndrome, azaspiracid poisoning (AZP), which is caused by the consumption of contaminated shellfish. A new, sensitive liquid chromatography/mass spectrometry (LC/MS) method has been developed for the determination of AZA1 and its analogues, 8-methylazaspiracid (AZA2) and 22-demethylazaspiracid (AZA3). Separation of these toxins was achieved using reversed-phase LC and coupled, via an electrospray ionisation (ESI) source, to an ion-trap mass spectrometer. Spectra showed the protonated molecules, [M + H]+, and their major product ions, due to the sequential loss of two water molecules, [M + H - H2O]+, [M + H - 2H2O]+, in addition to fragment ions that are characteristic of these cyclic polyethers. A highly specific and sensitive LC/MS(3) analytical method was developed and, using shellfish extracts containing AZA1, the detection limit (S/N = 3) was 4 pg on-column, corresponding to 0.8 ng/mL. Using the protocol presented here, this is equivalent to 0.37 ng/g shellfish tissue and good linear calibrations were obtained for AZA1 in shellfish extracts (average r2 = 0.9988). Good reproducibility was achieved with % RSD values (N = 5) ranging from 1.5% (0.75 microg/mL) to 4.2% (0.05 microg/mL). An efficient procedure for the extraction of toxins from shellfish aided the development of a rapid protocol for the determination of the three predominant azaspiracids. 相似文献
8.
Interlaboratory validation studies have been performed on 2 methods for the determination of chlormequat (CLQ) and mepiquat (MPQ). Both methods used identical extraction procedures and stable isotope internal standardization but differed in the use of liquid chromatography/mass spectrometry (LC/MS) or LC/tandem mass spectrometry (LC/MS/MS) for the determination, the amount of internal standard used, and the expected limit of detection. After addition of deuterated internal standards, CLQ and MPQ were extracted with methanol-water and determined by LC//MS or LC/MS/MS with positive electrospray ionization. Eight European laboratories participated in the LC/MS method study, analyzing mushroom, pear, wheat flour, and fruit puree with residues of CLQ in the range 0.040-1.19 mg/kg and of MPQ in the range 0.041-0.39 mg/kg. For CLQ, the Horwitz ratio (HoRat) values for individual test materials/levels were in the range 0.85-1.13 with a mean of 1.00, showing good method performance. For MPQ, the Ho values for mushroom, pear (both levels), and wheat flour were in the range 0.83-0.94, again indicating good method performance. For the determination of MPQ in infant food (fruit puree) at 0.041 mg/kg, the Ho was 1.7 when a value of 0 reported by one participant was excluded. In the LC/MS/MS study, in which 11 laboratories participated, a separate sample set was analyzed with residues of CLQ in the range 0.007-1.03 mg/kg and of MPQ in the range 0.008-0.72 mg/kg. Ho values for CLQ were in the range 0.27-1.36 and for MPQ in the range 0.51-2.10, all corresponding to acceptable method performance. 相似文献
9.
10.
Phenylketonuria is a common metabolic disorder disease. Those affected appear normal at birth, but without treatment they develop severe psychomotor retardation. Throughout life, they must control their blood levels of phenylalanine (Phe) and consume a diet containing adequate amounts of Phe and tyrosine (Tyr). We have developed a liquid chromatographic/mass spectrometric (LC/MS) method for the quantitative evaluation of Phe and Tyr in food samples. This method takes advantage of the good separation of LC and the selective and reliable quantification provided by MS in the electrospray ionization mode. The LC/MS method is very suitable for the determination of selected amino acids in various matrixes. It is sensitive to levels as low as about 0.30 ppm for Tyr and 0.70 ppm for Phe and robust. Nearly 100 nondietary food samples were analyzed by the developed method. 相似文献
11.
Kim Y Lee Y Kim M Yim YH Lee W 《Rapid communications in mass spectrometry : RCM》2000,14(18):1717-1726
Gestrinone was studied by high performance liquid chromatography (HPLC) for screening and by gas chromatography/mass spectrometry (GC/MS) for confirmation. When the chromatograms of blank, spiked urine and dosed urine were compared by HPLC, two unknown metabolites were found and these were excreted as the conjugated forms. Metabolites 1 and 2 were tested by LC/MS and LC/MS/MS and both had parent ions at m/z 325. The fragment ion of metabolite 1 was at m/z 263 and ions for metabolite 2 were m/z 307 [MH - H(2)O](+), 289, 279 and 241. LC/MS/MS of m/z 263 as the parent ion of metabolite 1 gave fragment ions at m/z 245 and 217, which were assumed to be [263 - H(2)O](+) and [235 - H(2)O](+), respectively. The trimethylsilyl (TMS)-enol-TMS ether derivative of gestrinone displayed three peaks in its GC/MS chromatogram, formed by tautomerism. 相似文献
12.
Harrold JA Sykes MD Goodrum M Fussell RJ 《Rapid communications in mass spectrometry : RCM》2004,18(7):775-779
A method for determination of triforine using high-performance liquid chromatography with electrospray tandem mass spectrometry was developed. A simple ethyl acetate extraction with solvent exchange into water/methanol was used for sample preparation. The method was validated at 0.01 and 0.05 mg kg(-1) levels in apple, tomato and tinned blackcurrants. Recoveries were in the range 56.6-99.8% and no matrix suppression or enhancement effects were observed. 相似文献
13.
The histamine level in tomato fruits and pastes was determined by 2 orthogonal techniques as a means of comparing accuracy. Close statistical agreement was found between assays for free histamine by capillary electrophoresis (with UV absorbance detection), and for the dansyl derivative by reversed-phase liquid chromatography (LC). Both techniques have adequate sensitivity for the analysis of endogenous histamine in tomatoes, but LC/electrospray tandem mass spectrometry was more sensitive by at least an order of magnitude, down to a level of 0.05 mg/kg. 相似文献
14.
A new method of flaxseed-derived lignan determination was developed using HPLC with high-resolution time-of-flight MS (TOF-MS), optimized, and compared to two existing methods (HPLC/MS/MS and GC/MS). The limits of detection (LODs) for HPLC/TOF-MS (0.002–0.043 pg) were comparable with those of the optimized and improved HPLC/MS/MS (0.001–0.015 pg), whereas the LODs for the optimized GC/MS were higher (0.02–3.0 pg, yet lower than reported before). Using the newly developed detection and separation methods, several key flaxseed sample preparation parameters (including extraction, hydrolysis, and sample purification) were evaluated resulting in the development of efficient protocol for lignan quantification from flaxseed hulls and embryos. The results confirmed the importance of quantification of both aglycones and unhydrolyzed glucosides in order to obtain the total lignan estimates. 相似文献
15.
Lakhani NJ Lepper ER Sparreboom A Dahut WL Venitz J Figg WD 《Rapid communications in mass spectrometry : RCM》2005,19(9):1176-1182
A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of 2-methoxyestradiol (2ME2) in human plasma. Sample pretreatment involved liquid-liquid extraction with ethyl acetate of 0.3-mL aliquots of plasma spiked with the internal standard, deuterated 2ME2 (2ME2-d5). Separation was achieved on a Zorbax Eclipse C18 column (2.1 x 50 mm, i.d., 5 microm) at room temperature using a gradient elution with methanol and water at a flow rate of 0.25 mL/min. Detection was performed using atmospheric pressure chemical ionization MS/MS by monitoring the ion transitions from m/z 303.1 --> 136.8 (2ME2) and m/z 308.1 --> 138.8 (2ME2-d5). Calibration curves were linear in the concentration range of 1-100 ng/mL. The accuracy and precision values, obtained from three different sets of quality control samples analyzed in quintuplicate on four separate occasions, ranged from 105-108% and from 3.62-5.68%, respectively. This assay was subsequently used for the determination of 2ME2 concentration in plasma of a patient with cancer after a single oral administration of 2ME2 at a dose of 2200 mg. 相似文献
16.
Thevis M Bredehöft M Geyer H Kamber M Delahaut P Schänzer W 《Rapid communications in mass spectrometry : RCM》2006,20(23):3551-3556
Synacthen is a synthetic analogue to human adrenocorticotropin, which plays an important physiological role by stimulating production of cortisol. In sports, corticosteroids as well as releasing factors (corticotropins) are prohibited according to the regulations of the World Anti-Doping Agency, and the misuse of Synacthen has been reported several times. Hence, an assay enabling the detection of Synacthen in doping control samples has been developed using immunoaffinity chromatographic isolation of Synacthen from human plasma combined with a concentration of collected fractions using solid-phase extraction. Unambiguous determination of the target analyte was accomplished using microbore liquid chromatography/electrospray ionization tandem mass spectrometry. Diagnostic product ions such as m/z 223 were characterized using high-resolution/high-accuracy Orbitrap mass spectrometry and employed for triple quadrupole MS/MS analysis. The established assay requiring 2 mL of plasma allowed a lower limit of detection (LLOD) at 100 fmol/mL, a recovery of 97% and a precision at the LLOD < 20%. Authentic plasma samples obtained from a patient undergoing a standard short Synacthen test were used to prove the applicability of the developed procedure. 相似文献
17.
Determination of pharmaceuticals in biosolids using accelerated solvent extraction and liquid chromatography/tandem mass spectrometry 总被引:1,自引:0,他引:1
An analytical method was developed to quantitatively determine pharmaceuticals in biosolid (treated sewage sludge) from wastewater treatment plants (WWTPs). The collected biosolid samples were initially freeze dried, and grounded to obtain relatively homogenized powders. Pharmaceuticals were extracted using accelerated solvent extraction (ASE) under the optimized conditions. The optimal operation parameters, including extraction solvent, temperature, pressure, extraction time and cycles, were identified to be acetonitrile/water mixture (v/v 7:3) as extraction solvent with 3 extraction cycles (15 min for each cycle) at 100 °C and 100 bars. The extracts were cleaned up using solid-phase extraction followed by determination by liquid chromatography coupled with tandem mass spectrometry. For the 15 target pharmaceuticals commonly found in the environment, the overall method recoveries ranged from 49% to 68% for tetracyclines, 64% to 95% for sulfonamides, and 77% to 88% for other pharmaceuticals (i.e. acetaminophen, caffeine, carbamazepine, erythromycin, lincomycin and tylosin). The developed method was successfully validated and applied to the biosolid samples collected from WWTPs located in six cities in Michigan. Among the 15 target pharmaceuticals, 14 pharmaceuticals were detected in the collected biosolid samples. The average concentrations ranged from 2.6 μg/kg for lincomycin to 743.6 μg/kg for oxytetracycline. These results indicated that pharmaceuticals could survive wastewater treatment processes, and accumulate in sewage sludge and biosolids. Subsequent land application of the contaminated biosolids could lead to the dissemination of pharmaceuticals in soil and water environment, which poses potential threats to at-risk populations in the receiving ecosystems. 相似文献
18.
Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting of the explosive products. Other areas are strictly related to forensic analysis of samples coming either from explosion areas where the matrix is various (metal, glass, wood, scraps), or from explosives transportation related to international terrorism. Generally speaking, for these applications the bulk of the matrix seriously interferes in the detection of the explosive analyte, which is usually present at trace levels. Unfortunately, despite some improvements, analytical techniques developed up today in this domain are still faced to two main constraints: the introduction of new products with unanticipated chemico-physical properties and the requirement of a routine and fast analytical method which can handle any matrix with a minimal clean-up and performing a sensitivity compatible either with the ever-decreasing demanded detection limit and with the ever-decreasing available specimen amount. These requirements can be fulfilled now by the new LC-MS and LC-MSMS techniques: mass spectrometry (MS) is likely an universal detector but even specific, especially when implemented in tandem MS (MSMS); LC is by far the most suitable technique to handle such a kind of compounds. Moreover, of a particular concern are some explosives which are reported to be thermally stable but difficult to dissolve. Some of the experiments on characterization of explosives [Octagen (HMX), Ethyleneglycol dinitrate (EGDN), Exogen (RDX), Propanetriol trinitrate (NG), Trinitrotoluene (TNT), N-Methyl-N-tetranitrobenzenamine (TETRYL), Dintrotoluene (DNT), Bis-(nitrooxy-methyl) propanediol dinitrate (PETN), Hexanitrostilbene (HNS), Triazido-trinitrobenzene (TNTAB), Tetranitro-acridone (TENAC), Hexa-nitrodiphenylamine (HEXYL), Nitroguanidine (NQ)] by LC-MS and LC-MSMS with the API-IonSpray source and using the Parent-Scan technique are presented. 相似文献
19.
Favetta P Dufresne C Désage M Païssé O Perdrix JP Boulieu R Guitton J 《Rapid communications in mass spectrometry : RCM》2000,14(20):1932-1936
Using hyphenated analytical techniques, gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), a study on minor propofol metabolites in human urine was conducted. These techniques allowed identification of two new phase I metabolites (2-(omega-propanol)-6-isopropylphenol and 2-(omega-propanol)-6-isopropyl-1,4-quinol). In addition, their four corresponding conjugates (three glucuronides and one sulphate) were detected. Thus in human urine at least eight conjugate metabolites are produced, derived from four different aglycones (propofol; 2, 6-diisopropyl-1,4-quinol; 2-(omega-propanol)-6-isopropylphenol and 2-(omega-propanol)-6-isopropyl-1,4-quinol). 相似文献
20.
Oxidative stress plays an important role in pathogenesis of many diseases. Measurement of 3-nitrotyrosine (NO(2)Tyr), as a potential biomarker for nitric oxide-mediated damage, has recently been the focus of particular attention. We have developed an HPLC method with NBD-F pre-column derivatization followed by C(18) cartridge cleaning. Using this method we achieved limits of detection of 0.5 and 1.1 nm for NO(2)Tyr and tyrosine (Tyr), respectively, close to that achieved by LS-MS/MS. NO(2)Tyr and tyrosine concentrations were linear over the calibration ranges 0.5-100 nm and 1-320 microm, respectively, with correlation coefficients greater than 0.95. To evaluate the utility of this assay in plasma we analysed samples obtained from smokers and non-smoking subjects. Consistent with the presence of elevated oxidative stress, the plasma NO(2)Tyr concentration and NO(2)Tyr:Tyr ratio of smokers were 17.42 +/- 11.6 nm and 0.263 +/- 0.192 nm/microm with 3.8 and 3.9 times higher (both p < 0.05), respectively, than that of non-smoker controls (4.54 +/- 2.75 nm and 0.067 +/- 0.050 nm/microm, respectively). In conclusion, we have developed a novel HPLC assay for NO(2)Tyr without MS detection that is applicable to clinical studies addressing the pathophysiology and importance of oxidative stress. 相似文献