首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
The method presented here allows the monitoring of persistent organochlorine compounds in breast milk using the solid phase microextraction technique (SPME) and gas chromatography with electron capture detection (GC-ECD). It describes the determination of hexachlorobenzene (HCB), alpha-, beta-, and gamma-hexachlorocyclohexane (HCH), dichlorodiphenyltrichloroethane (DDT) and its derivatives, and some important congeners of the polychlorinated biphenyls (PCB). Also included are more polar substances such as tri-, tetra- and penta-chlorophenols, which can be analyzed simultaneously with the afore-mentioned less polar compounds without the need of a derivatization for the determination of the phenolic compounds. The reproducibility of the results is very good down to the lower microg/L-region. The method is very fast and of low cost compared to the classic extraction and determination procedures.  相似文献   

2.
Biomonitoring of persistent organochlorine compounds in blood using the solid phase microextraction technique (SPME) and gas chromatography with electron capture detection (GC-ECD) is described. Polar substances as tri-, tetra- and penta-chlorophenols are analyzed simultaneously with less polar compounds such as hexachlorobenzene (HCB), α-, β-, and γ-hexachlorocyclohexane (HCH), dichlorodiphenyltrichloroethane (DDT) and its derivatives and with some important congeners of the polychlorinated biphenyls (PCB). No derivatization is needed for the determination of the phenolic compounds. The results show a good reproducibility down to the lower μg/L-region. The method is very fast and of low cost compared to the classic extraction and determination procedures.  相似文献   

3.
Biomonitoring of persistent organochlorine compounds in blood using the solid phase microextraction technique (SPME) and gas chromatography with electron capture detection (GC-ECD) is described. Polar substances as tri-, tetra- and penta-chlorophenols are analyzed simultaneously with less polar compounds such as hexachlorobenzene (HCB), α-, β-, and γ-hexachlorocyclohexane (HCH), dichlorodiphenyltrichloroethane (DDT) and its derivatives and with some important congeners of the polychlorinated biphenyls (PCB). No derivatization is needed for the determination of the phenolic compounds. The results show a good reproducibility down to the lower μg/L-region. The method is very fast and of low cost compared to the classic extraction and determination procedures. Received: 7 July 1997 / Revised: 6 October 1997 / Accepted: 21 October 1997  相似文献   

4.
The determination of polar and nonpolar organophosphorus compounds, triazines and their metabolites, molinate and chlorothalonil in 1 l water samples was investigated using off-line solid-phase extraction followed by gas chromatography with nitrogen-phosphorus and flame photometric detection. The ethylvinylbenzene-divinylbenzene copolymer (LiChrolut EN) and the commercial graphitized carbon black (GCB) of Envi-Carb were tested as solid-phase sorbents. The matrix effect was studied by extracting the compounds spiked in water samples of different types (Milli-Q, tap, salted tap water, river and sea water). The polymeric sorbent LiChrolut EN allowed the determination at low ng/l of all 40 compounds tested, except the very polar atrazine-desethyl-deisopropyl (DDA). Recoveries of compounds from the Envi-Carb sorbent are comparable to those obtained for LiChrolut EN with the exception of chlorothalonil and the more hydrophobic organophosphorus compounds (coumaphos, leptophos), which were strongly sorbed in the Envi-Carb cartridges. Envi-Carb, however, enabled the determination of DDA with a limit of detection of 14 ng/l.  相似文献   

5.
It was demonstrated that four out of six of the very polar organophosphorus pesticides (OPs), i.e. acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion, could not be extracted from water using commonly available SPE cartridges. In addition, GC analysis on all six compounds was found to be troublesome due to their polar and thermolabile character. This initiated the development of an alternative highly sensitive and selective method for the determination of the above mentioned very polar OPs in water, based on LC-MS. Large volume (1 ml) water samples were directly injected onto an RP18 HPLC column with a polar endcapping. The latter was essential for obtaining retention and maintaining column performance under 100% aqueous conditions during the sampling. The compounds were ionized using atmospheric pressure chemical ionization and detected on a tandem mass spectrometer operated in multiple reaction-monitoring mode. The detection limits were in the range of 0.01-0.03 microg/l. Compared to conventional GC methods, the developed LC-MS procedure is very straightforward, fast and more reliable. This application demonstrates the applicability of LC-MS for analysis of polar OPs in surface, ground and drinking water, as a more favourable alternative to GC.  相似文献   

6.
Zougagh M  Ríos A 《Electrophoresis》2008,29(15):3213-3219
An automatic method for the separation and determination of riboflavin (RF) vitamins (RF, flavin mononucleotide and flavin adenine dinucleotide) in food samples (chicken liver, tablet and powder milk) is proposed. The method is based on the on-line coupling of a supercritical fluid extractor (SFE) with a continuous flow-CE system with guided optical fiber fluorimetric detection (CF-CE-FD). The whole SFE-CF-CE-FD arrangement allowed the automatic treatment of food samples (clean-up of the sample followed by the extraction of the analytes), and the direct introduction of a small volume of the extracted plug to the CE-FD system for the determination of RF vitamins. Fluorescence detection introduced an appropriated sensitivity and contributed to avoid interferences of nonfluorescent polar compounds coming from the matrix samples in the extracted plug. Electrophoretic responses were linear within the 0.05-1 microg/g range, whereas the detection limits of RF vitamins were in the 0.036-0.042 microg/g range. The proposed arrangement opens up interesting prospects for the direct determination of polar analytes in complex samples with a good throughput and high level of automation.  相似文献   

7.
《Analytical letters》2012,45(8):1329-1349
Abstract

A simple and sensitive method for the spectrophotometric determination of bio-active compounds (drugs and non-nutritive sweeteners) containing reactive functional groups, viz., aromatic primary amine (drugs: Dapsone, Sulphamethoxazole), aromatic secondary amine (drug: Pindolol), aliphatic secondary amine (non-nutritive sweetener: Cyclamate), acid hydrazide (drug: Isoniazid) and thiol (drug: Captopril), is proposed. The method involves the addition of excess of sodium nitrite to the compound in the presence of 0.25 M hydrochloric acid solution and the unreacted nitrous acid is determined by the measurement of corresponding decrease in the absorbance of cresyl fast violet acetate (Δmax : 555 nm), the most suitable one out of several dyes tested. This method was applied for the determination of bio-active compounds in commercial samples. (drugs: pharmaceutical formulations; non-nutritive sweetener (cyclamate): foodstuffs). The newly proposed method enabled the determination of the bio-active compounds in microgram quantities (0.1 - 0.5 μg/ml). Standard deviation values evaluated through replicate determinations were found to be < 0.5 mg per dose (RSD : 0.5 - 1.2%). The common excipients do not effect the determination of the drugs in pharmaceutical formulations. Many of the usually occurring additives in food stuffs are tolerated to a very high level in the determination of cyclamate in beverages, syrup, ice candy and ice cream. The validity of the method was tested against the reference method. Recoveries to the tune of 99.2 - 101.1% were observed by adopting this method.  相似文献   

8.
王星  池玉梅  康安 《色谱》2014,32(12):1326-1332
为建立中药材中氨基类极性非紫外活性成分的定性与定量分析方法,以中药材天南星为研究对象,采用柱前衍生化技术,以异硫氰酸苯酯(PITC)为衍生化试剂,经C18色谱柱(100 mm×2.1 mm, 3.5 μm)分离和超高效液相色谱-串联质谱(UHPLC-MS/MS)分析,共解析了天南星中20个成分,包括18个氨基酸和2个胺类化合物。经优化衍生化条件,应用高效液相色谱法(HPLC),以Diamonsil C18色谱柱(250 mm×4.6 mm, 5 μm)分离,以乙腈和0.05 mol/L醋酸铵-醋酸缓冲液(pH 6.5)为流动相,梯度洗脱,在254 nm下检测,建立了同时测定15种氨基酸含量的方法,经方法学考察符合含量测定要求。谷氨酸、色氨酸在2~100 mg/L范围内、精氨酸在6~300 mg/L范围内、其余各氨基酸在0.8~40 mg/L范围内均呈良好的线性关系,相关系数均不小于0.9995;平均回收率在95%~105%之间,RSD均小于3%;并成功应用于12批中药材的测定。本方法简便、灵敏、准确,具有可操作性,可用于快速鉴定中药中的氨基类成分以及进行含量测定。  相似文献   

9.
A miniaturized liquid-phase extraction procedure based on directly suspended droplet microextraction is proposed for determining different classes of polyphenols. A derivatization reaction by means of in injection-port reaction with bis(trimethylsilyl)trifluoroacetamide is carried out to convert the polar non-volatile polyphenols into volatile derivatives. The separation and detection is carried out by coupling gas chromatography with mass spectrometry in the selected ion monitoring mode. The procedure uses undecanone, a low density organic solvent, and several factors influencing the extraction, collection efficiency and derivatization reaction are optimized. Excellent linearity was obtained for the range studied (0.05-500ngmL(-1)). The limits of detection are between 0.011 and 0.13ngmL(-1), depending on the compound, and the limits of quantification between 0.037 and 0.43ngmL(-1). The sensitivity and detection limits for polyphenols using the DSDME sample pretreatment method were very low. Enrichment factors are between 413 and 578. The recoveries obtained for spiked samples are satisfactory for all the compounds. The coupled miniaturized method is applied to the sensitive determination of both cis- and trans-resveratrol isomers, piceatannol, catechin, epicatechin, quercetin and fisetin in herbal infusions, fruits, juices and functional foods.  相似文献   

10.
Lan L  Hu B  Yu C 《Journal of chromatography. A》2010,1217(45):7003-7009
An organic-inorganic hybrid titania-hydroxy-terminated silicone oil (titania-OH-TSO) stir bar coating was prepared by sol-gel method. The extraction performance of titania-OH-TSO coated stir bar was evaluated and compared with poly(dimethysiloxane) (PDMS), poly(dimethysiloxane)-divinylbenzene (PDMS-DVB), poly(dimethysiloxane)-β-cyclodextrin (PDMS-β-CD) and C(18) coated stir bar with five polar drugs of abuse including amphetamine (PA), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and ketamine (Ke) as the model analytes. The experimental results revealed that the titania-OH-TSO coated stir bar exhibited highly pH-resistant ability, good preparation reproducibility, superior selectivity and high extraction efficiency for the target compounds. Based on this fact, a new method of titania-OH-TSO coated stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet visible (UV) detection was developed for the analysis of five drugs of abuse in urine samples. The factors affecting the extraction efficiency of SBSE such as sample pH, desorption solvent, sample volume, extraction time, desorption time, stirring rate and ionic strength were investigated and the optimal extraction conditions were established. Under the optimized conditions, the limits of detection (LODs) for titania-OH-TSO coated SBSE-HPLC-UV determination of five polar drugs of abuse were in the range of 2.3-9.1 μg/L with relative standard deviations (RSDs) ranging from 7.3 to 8.9% (c=300 μg/L, n=6), and all of the target compounds exhibited good linearity over a concentration range of 30-3000 μg/L. The developed method was applied to the determination of amphetamines and Ke in urine samples of drug abusers with satisfactory results.  相似文献   

11.
12.
An indirect colorimetric method is presented for detection of trace amounts of hydroquinone (1), catechol (2) and pyrogallol (3). The reduction of AuCl4(-) to Gold nanoparticles (Au-NPs) by these phenolic compounds in the presence of cetyltrimethylammonium chloride (CTAC) produced very intense surface plasmon resonance peak of Au-NPs. The plasmon absorbance of Au-NPs allows the quantitative colorimetric detection of the phenolic compounds. The calibration curves derived from the changes in absorbance at lambda = 568 nm were linear with concentration of hydroquinone, catechol and pyrogallol in the range of 7.0 x 10(-7) to 1.0 x 10(-4)M, 6.0 x 10(-6) to 2.0 x 10(-4)M and 6.0 x 10(-7) to 1.0 x 10(-4)M, respectively. The detection limits were 5.3 x 10(-7), 2.5 x 10(-6) and 3.2 x 10(-7)M for the hydroquinone, catechol and pyrogallol, respectively. The method was applied satisfactorily to the determination of phenolic compounds in water samples and pharmaceutical formulations.  相似文献   

13.
In this contribution, bar adsorptive micro-extraction using polystyrene-divinylbenzene sorbent phase and in situ derivatization with pentafluorophenyl hydrazine, followed by liquid desorption and high-performance liquid chromatography-diode array detection (BAμE(PS-DVB)(PFPH in situ)-LD/HPLC-DAD), was developed for the determination of six short-chain carbonyl compounds (formaldehyde, acetaldehyde, propanal, acetone, butanone, and 2-hexenal) in drinking water matrices. PFPH presented very good specificity as an in situ derivatization agent for short-chain ketones and aldehydes in aqueous media, allowing the formation of adducts with remarkable sensitivity, selectivity and the absence of photodegradation. Assays performed on 30-mL water samples spiked at the 25.0 μg L(-1) levels, under optimized experimental conditions, yielded recoveries ranging from 47.4 ± 3.8% to 85.2 ± 3.8%, in which the PS-DVB proved to be a convenient sorbent phase. The analytical performance showed good accuracy, suitable precision (RSD < 13.0%), detection limits in between 47 and 132 ng L(-1) and remarkable linear dynamic ranges (r(2) > 0.9907) from 1.0 to 80.0 μg L(-1). By using the standard addition methodology, the application of the present method to drinking water samples treated with different disinfectants, namely, chloride, ozone and both, allowed very good performances to monitor these priority compounds at the trace level. The proposed methodology proved to be a feasible alternative for polar compound analysis, showing to be easy to implement, reliable, sensitive and requiring a low sample volume to monitor short-chain aldehydes and ketones in drinking water matrices.  相似文献   

14.
A procedure using alkaline extraction, solid-phase extraction (SPE) and HPLC is developed to analyze the polar herbicides 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-chloro-2-methylphenoxyacetic acid (MCPA) together with their main metabolites in soils. An ion-pairing HPLC method is used for the determination as it permits the baseline separation of these highly polar herbicides and their main metabolites. The use of a highly cross-linked polystyrene-divinylbenzene sorbent (PS-DVB) gives the best results for the analysis of these compounds. This sorbent allows the direct preconcentration of the analytes at the high pH values obtained after quantitative alkaline extraction of the herbicides from soil samples. Different parameters are evaluated for the SPE preconcentration step. The high polarity of the main analytes of interest (2,4-D and MCPA) makes it necessary to work at low flow rates (< or =0.5 mL min(-1)) in order for these compounds to be retained by the PS-DVB sorbent. A two stage desorption from the SPE sorbent is required to obtain the analytes in solvents that are appropriate for HPLC determination. A first desorption with a 50:50 methanol:water mixture elutes the most polar analytes (2,4-D, MCPA and 2CP). The second elution step with methanol permits the analysis of the other phenol derivatives. The humic and fulvic substances present in the soil are not efficiently retained by PS-DVB sorbents at alkaline pH's and so do not interfere in the analysis. This method has been successfully applied in the analysis of soil samples from a golf course treated with a commercial product containing esters of 2,4-D and MCPA as the active components.  相似文献   

15.
A new sensitive method has been successfully developed and validated for the simultaneous determination and quantification of nine estrogenic UV filters (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-4, 4,4-dihydroxybenzophenone, ethyl-4-aminobenzoate, 2-ethyl-hexyl-4-trimethoxycinnamate, 3-(4-methylbenzylidene)-camphor, 3-benzylidene-camphor) in different environmental matrices. After optimisation of extraction conditions for the best recovery of polar to lipophilic compounds from fish tissue and a subsequent lipid clean-up in HPLC, fish extraction recoveries exceeded 72% for all nine UV filters. Identification and quantification of compounds was performed for lipophilic UV filters with gas chromatography-electroionisation-mass spectrometry and for polar and mid-polar compounds with liquid chromatography coupled to electrospray ionisation mass spectrometry. Instrumental detection limits (IDL) varied between 5 and 260 pg injected and method detection limits (MDL) were in the low ng/g lipids range for all test compounds. The described analytical methods are shown to be useful to screen for estrogenic UV filters in environmental samples such as fish and polar organic chemical integrative samplers.  相似文献   

16.
The remarkable effect of the solvent on the catalytic performance of H3PW12O40, the strongest heteropoly acid in the Keggin series, allows direction of the transformations of alpha-pinene oxide (1) to either campholenic aldehyde (2), trans-carveol (3), trans-sobrerol (4 a), or pinol (5). Each of these expensive fragrance compounds was obtained in good to excellent yields by using an appropriate solvent. Solvent polarity and basicity strongly affect the reaction pathways: nonpolar nonbasic solvents favor the formation of aldehyde 2; polar basic solvents favor the formation of alcohol 3; whereas in polar weakly basic solvents, the major products are compounds 4 a and 5. On the other hand, in 1,4-dioxane, which is a nonpolar basic solvent, both aldehyde 2 and alcohol 3 are formed in comparable amounts. The use of very low catalyst loading (0.005-1 mol %) and the possibility of catalyst recovery and recycling without neutralization are significant advantages of this simple, environmentally benign, and low-cost method. This method represents the first example of the synthesis of isomers from alpha-pinene oxide, other than campholenic aldehyde, with a selectivity that is sufficient for practical usage.  相似文献   

17.
Many environmental samples contain complex mixtures of organic compounds with different sources, polarities and reactivities. This study reports a method for the analysis of both polar/water-soluble and apolar organic compounds in several kinds of environmental samples. The analytical method consists of extraction with a mixture of dichloromethane:methanol (2:1, v/v), silylation using BSTFA (N,O-bis-(trimethylsilyl)trifluoroacetamide) and analysis by gas chromatography-mass spectrometry (GC-MS), a common device in chemical and environmental laboratories. Fifty individual sugar standards, including monosaccharides, sugar alcohols, anhydrosugars, disaccharides and trisaccharides, were analyzed for the determination of their fragmentation patterns and retention times. Recoveries (at three concentrations) and limits of detection (LOD) were determined for a standard mixture containing glucose (monosaccharide), sorbitol (sugar alcohol), levoglucosan (anhydrosugar) and sucrose (disaccharide), and they varied from 68 to 119% and 130 to 360 ng mL(-1), respectively. The method was used for the analysis of aerosol particle, soil and sediment samples, and demonstrated its feasibility in detecting not only several important environmental sugars (e.g., glucose, fructose, inositol, mannitol, sorbitol, levoglucosan, sucrose, mycose), but also a large range of organic compound classes from other polar components (e.g., dicarboxylic acids) to apolar compounds such as n-alkanes. Therefore, the analytical method presented here demonstrated its usefulness for a better understanding of sources and transport of various organic compounds in different environmental compartments.  相似文献   

18.
In this paper we will show the results of our research on the direct simultaneous determination of multi-class pesticides and transformation products with different polarities and acid-base properties by applying an on-line trace enrichment coupled to the chromatographic system supplied with electrospray interface (SPE-LC-MS/MS method). The specific chromatographic separation allows the correct determination of almost fifty compounds (37 pesticides and 10 transformation products) using very low sample volume and very little sample handling. Recoveries between 70-120% were obtained for all compounds in drinking and groundwater, meanwhile in surface water 44 compounds were correctly quantified. Relative standard deviations lower than 15% were obtained for all compounds. Even at the lowest concentration level tested (25 ng L(-1)) 40 compounds presented satisfactory recoveries and repeatability. The use of methanol as organic modifier and the increase of injection volume are also studied. The applicability of the developed method to a monitoring programme is demonstrated by applying it to the analysis of hundreds of samples.  相似文献   

19.
电喷雾电离质谱在化学中应用新进展   总被引:11,自引:0,他引:11  
魏先文  徐正 《有机化学》1999,19(1):97-103
电喷雾电离质谱(ESI-MS)是本世纪发展的非常重要的质谱,具有无碎片的特点,可分析检测非挥发性的、极性的、热不稳定的化合物。评述了ESI-MS在富勒烯化学、无机配合物、簇合物、有机化学反应,金属有机化合物及超分子化学中的应用进展。  相似文献   

20.
A capillary electrophoresis/electrospray ionisation mass spectrometry (CE/ESI-MS) method was developed for the determination of 38 organic acids in atmospheric particles and cloud water. The target analytes include many functionalised carboxylic acids, such as carboxylic acids with additional oxo-, hydroxy- or nitro-groups. These compounds are of large interest as their determination might give new insights into the atmospheric multiphase chemistry. OASIS HLB sorbent material (Waters) was used to extract and enrich polar carboxylic acids from aqueous solutions with recoveries greater than 80% for most analytes. Relative standard deviations in the range of 4-20% for peak areas (n=5), including the SPE step, and 0.2-0.5% (n=8) for migration times were found. The limits of detection (S/N=3) ranged from 0.005 to 0.6 micromol l(-1) for an ion-trap mass spectrometer and from 0.0004 to 0.08 micromol l(-1) for a time-of-flight mass spectrometer. These detection limits translate into atmospheric concentrations in the low pg m(-3) range based on the experimental conditions in this study. Severe matrix effects were observed for real samples, arising from complex co-extracted organic material. However, using the method of standard addition, most of the analytes could successfully be quantified in samples of ambient particles and cloud water with concentrations in the low ng m(-3) to high pg m(-3) range. These results demonstrate the suitability of the proposed method for the determination of a wide range of polar carboxylic acids at low concentrations in complex samples of different atmospheric phases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号