首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Scanning electrochemical microscopy (SECM) was used to investigate the effect of ion bombardment on thin films of the conducting polymers poly[3-ethoxy-thiophene] (PEOT) and poly[ethylenedioxy-thiophene] (PEDT). Bombardment with Ar+-ions converts the topmost 30 nm thick layer to an essentially insulating material. SECM approach curves as well as two dimensional scans prove the existence of regions of different conductivity within the irradiated regions that did not show a significant dependence on ion dosage. PEDT layers patterned by ion bombardment through microscopic masks are investigated as prototypes of miniaturized printed circuit boards that can be formed by galvanic copper deposition onto conducting PEDT. Defects in conducting polymer patterns were analyzed by SECM imaging before any deposition of copper. Appropriate representations of SECM images for the evaluation of this technologically important question are discussed.  相似文献   

2.
李建平  方成  顾海宁 《化学学报》2006,17(17):1812-1816
采用扫描电化学显微技术在玻碳电极表面沉积出K2Cu[Fe(CN)6]和K2Fe[Fe(CN)6]微阵, 并对所得的微阵结构进行了可视化表征. 铜微电极和镀铁铂微电极阳极化产生金属离子, 然后与玻碳电极(基底电极)上还原产生的[Fe(CN)6]4-在微区生成六氰合铁酸盐沉淀, 操纵探针以跳跃沉积方式可以得到沉淀的点阵结构. 通过改变K3[Fe(CN)6]的浓度和沉积时间可以调整沉淀斑的直径和厚度. 扫描电化学显微镜成像表明微阵结构对多巴胺的氧化和过氧化氢的还原有明显的电催化作用.  相似文献   

3.
Secondary ion mass spectra obtained by [Xe]+ bombardment are compared with those obtained by [Ar]+ bombardment. Although [Ar]+ ions are commonly used as primary ions in secondary ion mass spectrometry for organic compounds, [Xe]+ ions seem better as primary ions because they give a larger sputtering yield for a metal substrate than [Ar]+ ions. Cationized molecular intensities of sucrose, raffinose and stachyose, and quasimolecular ion intensities of tuftsin and eledoisin related peptide are investigated using [Xe]+ and [Ar]+ bombardments. The observed molecular species are 2–4 times more intense for [Xe]+ bombardment than for [Ar]+ bombardment, although the secondary ion mass spectra are almost the same in both cases.  相似文献   

4.
We report about a new kind of directly heated gold electrode. All electrodes including a directly heated gold loop electrode, a Ag pseudo reference, and a carbon counter electrode have been screen-printed on a ceramic alumina substrate. Thermal behaviour was studied by potentiometry using either an external or the integrated reference electrode. Stripping voltammetric copper signals were greatly improved at elevated deposition temperature. Secondary ion mass spectrometric studies (ToF-SIMS) revealed that different negative ionic species of copper complexes can be found on the gold electrode surface as a result of ion bombardment during SIMS analysis like Cu?, CuCl? and CuCl2 ?. SIMS surface imaging using a fine focussed ion beam over the surface allowed us to obtain ion images (chemical maps) of the analyzed sample. SIMS depth profile analysis of the gold loop electrode was performed after copper deposition at room temperature (23 °C) and at 60 °C. CuCl2 ? ion was used for the depth profile studies as it has shown the highest intensity among other observed species. Surface spectroscopic analysis, surface imaging and depth profile analysis have shown that the amount of deposited copper species on the gold loop electrode was increased upon increasing electrode temperature during the deposition step. Therefore, the presence of chloride in the solution will hinder underpotential deposition of Cu(0) and lead to badly defined and resolved stripping peaks.  相似文献   

5.
Scanning electrochemical microscopy (SECM) has been applied to investigate counter ion transport through four different proton conducting membranes with poly(styrene sulfonic acid) side chains. These membranes, intended for the polymer electrolyte fuel cell, are based on PVDF and PVDF-co-HFP matrix materials and have been prepared by an irradiation grafting method. SECM is found to be suitable for mapping variations in proton diffusion coefficient and concentration in these inhomogeneous membranes. It was found that the variations in these parameters are most considerable in a membrane with a high degree of grafting. Ionic conductivities measured with impedance spectroscopy were in agreement with calculated values obtained on the basis of the SECM measurements.  相似文献   

6.
A stable film of poly(3‐octylthiophene)–dihydroxyanthraquinone sulfonate has been synthesized electrochemically in non‐aqueous solution. The incorporation of dihydroxyanthraquinone sulfonate as an anionic complexing ligand into poly(3‐octylthiophene) film during electropolymerization was achieved and copper ions were accumulated by reduction on the electrode surface. The presence of dihydroxyanthraquinone sulfonate during the electrochemical polymerization of 3‐octylthiophene is shown to impact the sensitivity and the stability of the organic conducting film electrode response. The electroanalysis of copper(II) ions using conducting polymer electrode was achieved by differential pulse anodic stripping voltammetry with remarkable selectivity. The analytical performance was evaluated and linear calibration graphs were obtained in the concentration range of 50–400 ng mL?1 copper(II) ion for 240 seconds accumulation time and the limit of detection was found to be 7.8 ng mL?1. To check the selectivity of the proposed stripping voltammetric method for copper(II) ion, various metal ions as potential interferents were tested. The developed method was applied to copper(II) determination in certified reference material, NWRI‐TMDA‐61, trace elements in fortified water.  相似文献   

7.
The properties of poly(3,4-ethylenedioxythiophene) (PEDT) film have been studied in iodide solutions by cyclic voltammetry and stripping voltammetry methods. It has been shown that formation of charge-transfer complexes between iodine species and polymeric rings promotes storage of iodine on an electrode covered by PEDT film. Due to this behaviour the PEDT layer can be employed for electroanalysis of dilute (10−4–10−3 M) solutions of iodide salts by stripping voltammetry methods. The possibility of PEDT film application for zinc-iodide rechargeable batteries was also examined.  相似文献   

8.
Geometrically isomeric dicarboxylic acids, such as maleic and fumaric acid and their methyl homologues, and the isomeric phthalic acids, have been investigated using fast atom bombardment, field ionization and field desorption mass spectrometry. The most intense peak in the positive ion fast atom bombardment spectra corresponds with the [M + H]+ ion. This ion, when derived from the E -acids, tragments either by successive loss of water and carbon monoxide or by elimination of carbon dioxide. In the case of the Z -acids only elimination of water from the [M + H]+ ions is observed to occur to a significant extent. The same is true for the [M + H]+ ions of the isomeric phthalic acids, that is the [M + H] ions derived from iso- and terephthalic acid exhibit more fragmentation than those of phthalic acid. All these acids undergo much less fragmentation upon field ionization, where not only abundant [M + H]+ ions, but also abundant [M] ions, are observed. Upon field desorption only the [M + H]+ and [M + Na]+ ions are observed under the measuring conditions. Negative ion fast atom bombardment spectra of the acids mentioned have also been recorded. In addition to the most abundant [M? H]? ions relatively intense peaks are observed, which correspond with the [M]?˙ ions. The fragmentations observed for these ions appear to be quite different from those reported in an earlier electron impact study and in a recent atmospheric pressure ionization investigation.  相似文献   

9.
Védrine C  Fabiano S  Tran-Minh C 《Talanta》2003,59(3):535-544
An amperometric enzyme sensor using tyrosinase, also called polyphenol oxidase (PPO), was constructed for determination of phenolic compounds and herbicides. The enzyme was entrapped in a conducting polymer, poly 3,4-ethylenedioxythiophene (PEDT), electrochemically generated on a glassy carbon electrode. Several experimental parameters in the electropolymerisation process and working conditions were determined to optimise biosensor performances. Mono-phenol and di-phenol were tested in oxygenated solutions, by amperometric measurements at −200 mV (vs. SCE) in a batch system. The limit of detection of these molecules ranges from 5 to 500 nM. Detection of herbicides was obtained from the inhibition of tyrosinase electrode responses. The limit of detection for atrazine and diuron was 1 and 0.5 mg l−1 respectively. These data suggest that PEDT film is a promising PPO immobilisation method.  相似文献   

10.
The enhancement of the static secondary ion mass spectrometry (SIMS) signals resulting from the injection, closely to the sample surface, of H2O vapor at relatively high-pressure, was investigated for a set of organic materials. While the ion signals are generally improved with increasing H2O pressure upon 12 keV Ga+ bombardment, a specific enhancement of the protonated ion intensity is clearly demonstrated in each case. For instance, the presence of H2O vapor induces an enhancement by one order of magnitude of the [M+ H]+ static SIMS intensity for the antioxidant Irgafos 168 and a ∼1.5-fold increase for polymers such as poly(vinyl pyrrolidone).  相似文献   

11.
The use of copper ions for chemical ionization (CI) coupled with gas chromatography/mass spectrometry (GC/MS) of hydrocarbons is reported. Cu+?CI was performed in a high-pressure, fast atom bombardment ion source coupled with both a gas chromatograph and a mass spectrometer. The suitability of the Cu+?CI method is illustrated by the analysis of pure alkylbenzenes, alkylthiophenes, octenes, and by the analysis of a light mixture of aromatic hydrocarbons. The Cu+?CI/GC mass spectra display an abundant [M+63Cu]+ ion, together with fragmentations, that are of structural interest. The detection limit for isobutylbenzene, taken as model compound, is 100 times lower than that for electron ionization.  相似文献   

12.
A detailed study has been carried out of the fast atom bombardment tandem mass spectrometry (MS/MS) behavior of lithium-attachment ions from three glycol polymers: linear poly(ethylene glycol), linear poly(propylene glycol), and an ethoxylated fatty alcohol. Collisional activation was carried out in the “collision octapole” of a BEoQ hybrid mass spectrometer at a translational energy of 50 eV, with collision gas air. It was found that [M + Li]+ ions provide a number of advantages as precursors for practical MS/MS analysis as compared to the use of [M + H]+ or [M + Na]+ ions. First, [M + Li]+ ions are much more intense than the corresponding [M + H]+ ions. Second, [M + Li]+ ions dissociate to lithiated organic fragments with reasonable efficiency, which is not the case with [M + Na]+ precursors. Third, product ions are generally formed over the entire mass range for low molecular weight polyglycols. The most intense product ions are lithiated, linear polyglycol oligomers. These ions are formed via internal hydrogen transfer reactions which are facilitated by lithium (charge-induced). Two series of less intense product ions are formed via charge-remote fragmentations involving l,4-hydrogen elimination. A fourth product ion series consists of lithiated radical cations; these form via homolytic bond cleavages near chain ends. Overall, MS/MS analysis of [M + Li]+ polyglycol ions proved to be quite useful for chemical structure elucidation.  相似文献   

13.
During a comparison study of the fast atom bombardment (FAB) and electron impact mass spectra of 1-organyl-2,9,10-trioxa-6-aza-1-silatricyclo[4.3.3.01,6]dodecanes, an unusual ion peak at m/z 164 was noticed in the FAB spectra. Accurate mass measurement indicated that m/z 164 corresponds to protonated 1-[N,N-bis(2-hydroxyethyl)amino]-1-propanol (BHAP), which is produced by a ring-rupture reaction. Further experiment showed that the intensity of the [BHAP + H]+ ion peak increased markedly as the 7keV Ar0 bombardment proceeded, suggesting a FAB-induced reaction. The possible mechanism is also discussed.  相似文献   

14.
X‐ray photoelectron spectroscopy (XPS) has been used to characterize poly(3,4‐ethylene dioxythiophene)–poly(styrene sulfonate) (PEDT/PSS), one of the most common electrically conducting organic polymers. A correlation has been established between the composition, morphology, and polymerization mechanism, on the one hand, and the electric conductivity of PEDT/PSS, on the other hand. XPS has been used to identify interfacial reactions occurring at the polymer‐on‐ITO and polymer‐on‐glass interfaces, as well as chemical changes within the polymer blend induced by electrical stress and exposure to ultraviolet light. © 2003 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 41: 2561–2583, 2003  相似文献   

15.
Potentiometric ion sensors have been prepared by galvanostatic electrosynthesis of the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) doped with p-sulfonated calix[4]arene (C[4]S) and p-methylsulfonated calix[4]resorcarenes (Rn[4]S) with alkyl substituents of different chain length (R1=CH3; R2=C2H5; R3=C6H13). The bowl-shape of these doping ions makes them suitable as ionic recognition sites, and their bulky character is expected to prevent them from leaching out of the conducting polymer membrane. For comparison, sensors based on PEDOT doped with poly(styrene sulfonate) (PSS) and poly(vinyl sulfonate) (PVS) were also constructed. The resulting GC/PEDOT electrodes were conditioned in 0.01 mol L–1 AgNO3 and their performance as Ag+ ion-selective electrodes (ISEs) studied. Results reveal that selectivity and lifetime of the electrodes is affected by the doping anion structure, although all electrodes show selectivity towards Ag+ ions. Interaction of Ag+ with sulfur atoms present in the conducting polymer backbone is considered to be the main reason for this behavior. A second set of electrodes was constructed and conditioned in 0.1 mol L–1 KCl. These electrodes were tested in chloride solutions of quaternary ammonium cations, showing that C[4]S and R2[4]S exhibit significant sensitivity towards pyridinium.Dedicated to Professor György Horányi on the occasion of his 70th birthday in recognition of his outstanding contributions to electrochemistry  相似文献   

16.
The dinuclear copper complex (α-cyano-4-hydroxycinnamic acid (CHCA) copper salt (CHCA)4Cu2), synthesized by reacting CHCA with copper oxide (CuO), yields increased abundances of [M + xCu − (x−1)H]+ (x = 1–6) ions when used as a matrix for matrix-assisted laser desorption ionization (355 nm Nd:YAG laser). The yield of [M + xCu − (x−1)H]+ (x = 1∼6) ion is much greater than that obtained by mixing peptides with copper salts or directly depositing peptides onto oxidized copper surfaces. The increased ion yields for [M + xCu − (x−1)H]+ facilitate studies of biologically important copper binding peptides. For example, using this matrix we have investigated site-specific copper binding of several peptides using fragmentation chemistry of [M + Cu]+ and [M + 2Cu − H]+ ions. The fragmentation studies reveal interesting insight on Cu binding preferences for basic amino acids. Most notable is the fact that the binding of a single Cu+ ion and two Cu+ ions are quite different, and these differences are explained in terms of intramolecular interactions of the peptide-Cu ionic complex.  相似文献   

17.
Fast atom bombardment (FAB), FAB mass-analysed ion kinetic energy (FAB MIKE) and collision-activated dissociation (FAB CAD-MIKE) mass spectra were obtained for two series of unsaturated anomeric aryl C-glycosides. These tandem mass spectrometric techniques allowed the differentiation of the anomers by analysing either the [M + H]+ ion or the [M + met]+ ion (met=Li, Na).  相似文献   

18.
Positive and negative ion fast atom bombardment (FAB) mass spectra of some monosubstituted nitroaromatic isomers are reported. Generally ions carresponding to [M + H]+ and M+ are observed in the positive ion FAB spectra; ions such as [M ? H] ? and M?˙ are observed in the negative ion FAB spectra. The use of FAB mass spectra to distinguish the isomers is discussed. Comparisons of FAB, chemical ionization and electron impact mass spectra of the same isomers (wherever possible) are reported. The structural information obtained in the negative ion FAB spectra complement those obtained in the positive ion FAB spectra.  相似文献   

19.
In the present study, ion beam induced deposition (IBID) of platinum carbon (PtC) composite electrodes is evaluated for combined atomic force microscopy–scanning electrochemical microscopy (AFM–SECM) probes. After deposition, the PtC composite materials are post-treated using focused ion beam (FIB) milling to decrease the carbon content of the material. It is shown that this treatment leads to an improvement of electrode characteristics for selected analytes, including the oxidation of potassium hexacyanoferrate(II) trihydrate (Fe(CN)64?) and hydrogen peroxide (H2O2). Moreover, the proposed approach is compatible with microfabricated AFM–SECM probes for increasing the AFM tip-integrated electroactive area while maintaining the geometric dimensions, which is important for imaging biosensor development.  相似文献   

20.
Polyatomic primary ions offer low penetration depth and high damage removal rates in some polymers, facilitating their use in the molecular depth profiling of these polymers by secondary ion mass spectrometry (SIMS). This study is the second in a series of systematic characterizations of the effect of polymer chemistry on degradation under polyatomic primary ion bombardment. In this study, time‐of‐flight SIMS (ToF‐SIMS) was used to measure the damage of ~90 nm thick spin‐cast poly(methyl methacrylate), poly(n‐butyl methacrylate), poly(n‐octyl methacrylate) and poly(n‐dodecyl methacrylate) films under extended (~2 × 1014 ions cm?2) 5 keV SF5+ bombardment. The degradation of the poly(n‐alkyl methacrylates) were compared to determine the effect of the length of the alkyl pendant group on their degradation under SF5+ bombardment. The sputter rate and stability of the characteristic secondary ion intensities of these polymers decreased linearly with alkyl pendant group length, suggesting that lengthening the n‐alkyl pendant group resulted in increased loss of the alkyl pendant groups and intra‐ or intermolecular cross‐linking under SF5+ bombardment. These results are partially at variance with the literature on the thermal degradation of these polymers, which suggested that these polymers degrade primarily via depolymerization with minimal intra‐ or intermolecular cross‐linking. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号