首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
C. Hopkins  P. Turner 《Applied Acoustics》2005,66(12):1339-1382
Procedures for the field measurement of airborne sound insulation between rooms with diffuse fields are described in International Standard ISO 140-4. However, many dwellings contain rooms with volumes less than 50 m3, where low frequency measurements are less reliable; hence there is a need for a measurement procedure to improve the reliability of field measurements in rooms with non-diffuse fields. Procedures are proposed for sound pressure level and reverberation time measurements for the 50, 63 and 80 Hz third octave bands. The sound pressure level measurement combines corner microphone positions with positions in the central region of each room. This provides a good estimate of the room average sound pressure level with significantly improved repeatability.  相似文献   

2.
Octave band reverberation times, background noise levels and speech transmission indices measurements were carried out in eighteen government subsidized primary and secondary schools in Hong Kong. Various normal classroom operation conditions were considered. Results illustrate that strong correlation exists between the reverberation times and the speech transmission indices regardless of the background noise levels and their NC values in the present study. The arithmetic average of the reverberation times in the 250 Hz to 4 Hz octave bands and the 1 kHz octave band reverberation time are found to be more important in the correlation in general. These findings provide a convenient mean for speech transmission design in classrooms.  相似文献   

3.
Maximum sound pressure levels are commonly used for environmental noise and building acoustics measurements. This paper investigates the signal processing errors due to Fast or Slow time-weighting detectors when combined with octave band filters, one-third octave band filters or an A-weighting filter. For 6th order Butterworth CPB filters the inherent time delay caused by the phase response of filters is quantified using three different approaches to establish the following rules-of-thumb: (1) time-to-gradient/amplitude matching occurs when Bt  1, (2) time-to-peak matching occurs when Bt  2 and (3) time-to-settle matching occurs when Bt  4 for octave band filters, and when Bt  3 for one-third octave band filters. Four different commercially-available sound level meters are used to quantify the variation in measured maximum levels using tone bursts, half-sine pulses, ramped noise and recorded transients. Tone bursts indicate that Slow time-weighting is inappropriate for maximum level measurements due to the large bias error. The results also show that there is more variation between sound level meters when considering Fast time-weighted maximum levels in octave bands or one-third octave bands than with A-weighted levels. To reduce the variation between measurements with different sound level meters, it is proposed that limits could be prescribed on the phase response for CPB filters and A-weighting filters.  相似文献   

4.
It has long been recognized that single-number quantities Rw, DnT,w or Dn,w result in different conclusions in objective rating of airborne sound insulation between dwellings. The difference between the values of these single-number quantities (SNQ), however, does not prove which of them describes the sound transmission between rooms most correctly. The main object of this article was to study which SNQ correspond best with transmitted living sound levels in buildings when reverberation time, volume of receiving room and sound insulation are taken into account. Data of 100 field measurements of airborne sound insulation were collected as well as 207 reverberation times of furnished rooms. The transmitted sound levels of living sounds were evaluated on the basis of known living sound spectra and measured level differences D. The results show that the SNQs standardized to reference reverberation time of 0.5 s lead in all cases to best correlation between the SNQs and the sound levels of transmitted living sounds. It was also checked whether the rating by DnT,w would lead to higher transmitted sound levels of living sounds in larger rooms, but this was not detected. The use of DnT,w makes rooms of different volumes equal in regard to required sound insulation between them. It is thus justified to replace Rw with DnT,w as the SNQ for rating the airborne sound insulation. Widening the frequency range down to 50 Hz or up to 5000 Hz did not give noteworthy improvement in the correlation.  相似文献   

5.
Contours of equal loudness and threshold of hearing under binaural free-field conditions for the frequency range 20–15 000 Hz were standardized internationally in 1961. This paper describes an extension of the data in the low-frequency range down to 3·15 Hz, at l levels from threshold to 70 phon. The latter corresponds to nearly 140 dB sound pressure level at the lowest frequency. Direct loudness comparisons were made between tones at intervals of an octave, and the resulting contours were checked by numerical loudness estimation.  相似文献   

6.
The relation between human brain responses to an individual's annoyance of bandpass noise was investigated using magnetoencephalography (MEG) measurements and analysis by autocorrelation function (ACF) and cross-correlation function (CCF). Pure tone and bandpass noises with a centre frequency of 1000 Hz were used as source signals. The sound pressure level was constant at 74 dBA and the duration of the stimulus was 2.0 s. The scale values of annoyance for each subject were obtained by paired-comparison tests. In MEG measurements, the combination of a reference stimulus (pure tone) and test stimuli (bandpass noise) was alternately presented 30 times at a constant 2 s interstimulus interval. The results show that the effective duration of the ACF, τe, of MEG in the 8-13 Hz range, which represent repetitive features within the signal itself, became shorter during the presentation of an annoying stimulus. Also, the maximum value of the CCF, |φ(τ)|max, became smaller. The shorter τe and smaller |φ(τ)|max indicate that a wider area of the brain is unstable for longer with annoying auditory stimuli.  相似文献   

7.
Acoustic analysis of a liquefied petroleum gas-fired pulse combustor   总被引:1,自引:0,他引:1  
Experimental investigation of acoustic characteristics of a Helmholtz type liquefied petroleum gas-fired pulse combustor is presented. In the experiments, the length of the tail pipe was changed from 1.9 m to 1.3 m by 10 cm intervals. Sound level measurements were taken from the exhaust side (outlet) and air flapper side (inlet) at a distance of 1 m from both sides. With decreasing lengths of the tail pipe, the sound pressure level increased. At the measurements related to the exhaust side, the maximum value of equivalent continuous sound pressure level, LEQ was 96.6 dB when the length of the tailpipe and fundamental frequency were 1.3 m and 63 Hz, respectively. Same kinds of measurements were performed at the air flapper side, but the LEQ value was stronger at the exhaust side than the one at the air flapper side. It was also observed that the effect of the type of gaseous fuel on the acoustic efficiency of the pulse combustor can be neglected when the results of the acoustic efficiencies were compared to those in the literature. In order to compare the accuracy of frequencies measured by the sound level meter, a suitable dynamic pressure transducer and a spectrum analyzer were used to perform amplitude and frequency measurements. The average deviation between the measurements performed by the sound level meter and dynamic pressure transducer was 2.4 Hz (3.8% errors) while the average deviation was 3.8 Hz (6% errors) between the sound level meter and spectrum analyzer.  相似文献   

8.
The Fourier transform gas-phase IR spectrum of 1,2,5-thiadiazole, C2H2N2S, has been recorded with a resolution of ca. 0.003 cm−1 in the wavenumber region 750-1250 cm−1. Five fundamental bands in this region, ν4 (A1), ν5 (A1), ν11 (B1), ν13 (B1), and ν14 (B2), have been analysed by the Watson Hamiltonian model to yield ground-state rotational and quartic centrifugal distortion constants as well as upper-state spectroscopic constants. A global perturbation of the ν4 level is explained by Fermi resonance with the 2ν15 level which has been located from its resonance effect. Rotational constants, harmonic and anharmonic frequencies have been calculated using a cc-pVTZ basis, at the MP2 and B3LYP methodology levels, and compared with the experimental data.  相似文献   

9.
A diode-end-pumped passively Q-switched 912 nm Nd:GdVO4/Cr4+:YAG laser and its efficient intracavity frequency-doubling to 456 nm deep-blue laser were demonstrated in this paper. Using a simple V-type laser cavity, pulsed 912 nm laser characteristics were investigated with two kinds of Cr4+:YAG crystal as the saturable absorbers, which have the different initial transmissivity (TU) of 95% and 90% at 912 nm. When the TU = 95% Cr4+:YAG was used, as much as an average output power of 2.8 W 912 nm laser was achieved at an absorbed pump power of 34.0 W, and the pulse width and the repetition rate were ∼ 40.5 ns and ∼ 76.6 kHz, respectively. To the best of our knowledge, this is the highest average output power of diode-pumped passively Q-switched Nd3+-doped quasi-three-level laser. Employing a BiBO as the frequency-doubling crystal, 456 nm pulsed deep-blue laser was obtained with a maximum average output power of 1.2 W at a repetition rate ∼ 42.7 kHz.  相似文献   

10.
Single clouds of cavitation bubbles, driven by 254 kHz focused ultrasound at pressure amplitudes in the range of 0.48–1.22 MPa, have been observed via high-speed shadowgraphic imaging at 1 × 106 frames per second. Clouds underwent repetitive growth, oscillation and collapse (GOC) cycles, with shock-waves emitted periodically at the instant of collapse during each cycle. The frequency of cloud collapse, and coincident shock-emission, was primarily dependent on the intensity of the focused ultrasound driving the activity. The lowest peak-to-peak pressure amplitude of 0.48 MPa generated shock-waves with an average period of 7.9 ± 0.5 μs, corresponding to a frequency of f0/2, half-harmonic to the fundamental driving. Increasing the intensity gave rise to GOC cycles and shock-emission periods of 11.8 ± 0.3, 15.8 ± 0.3, 19.8 ± 0.2 μs, at pressure amplitudes of 0.64, 0.92 and 1.22 MPa, corresponding to the higher-order subharmonics of f0/3, f0/4 and f0/5, respectively. Parallel passive acoustic detection, filtered for the fundamental driving, revealed features that correlated temporally to the shock-emissions observed via high-speed imaging, p(two-tailed) < 0.01 (r = 0.996, taken over all data). Subtracting the isolated acoustic shock profiles from the raw signal collected from the detector, demonstrated the removal of subharmonic spectral peaks, in the frequency domain. The larger cavitation clouds (>200 μm diameter, at maximum inflation), that developed under insonations of peak-to-peak pressure amplitudes >1.0 MPa, emitted shock-waves with two or more fronts suggesting non-uniform collapse of the cloud. The observations indicate that periodic shock-emissions from acoustically driven cavitation clouds provide a source for the cavitation subharmonic signal, and that shock structure may be used to study intra-cloud dynamics at sub-microsecond timescales.  相似文献   

11.
The interaural level difference (ILD) is an important cue for the localization of sound sources. Just noticeable differences (JND) in ILD were measured in 12 normal hearing subjects for uncorrelated noise bands with a bandwidth of 13 octave and a different center frequency in both ears. In one ear the center frequency was either 250, 500, 1000, or 4000 Hz. In the other ear, a frequency shift of 0, 16, 13, or 1 octave was introduced. JNDs in ILD for unshifted, uncorrelated noise bands of 13 octave width were 2.6, 2.6, 2.5, and 1.4 dB for 250, 500, 1000, and 4000 Hz, respectively. Averaged over all shifts, JNDs decreased significantly with increasing frequency. For the shifted conditions, JNDs increased significantly with increasing shift. Performance on average worsened by 0.5, 0.9, and 1.5 dB for shifts of 16, 13, and 1 octave. Though performance decreases, the just noticeable ILDs for the shifted conditions were still in a range usable for lateralization. This has implications for signal processing algorithms for bilateral bimodal hearing instruments and the fitting of bilateral cochlear implants.  相似文献   

12.
Sound pressure level measurements in cars travelling at motorway speeds have shown that, in many cases, the overall level is very high in relation to the dB(A) and octave band levels, suggesting that much of the sound energy is in the low frequency and infrasonic regions. A technique has been developed to extend accurate octave band measurements down to the octave centred on 2 Hz. The system uses a calibrated sound level meter feeding a frequency modulation tape-recorder to record noise below 64 Hz, and an octave band analysis system to analyse the resultant tape recordings. Typical results are presented for a number of vehicles and it is found that sound pressure levels as high as 120 dB can be found in the octave bands between 2 and 16 Hz.  相似文献   

13.
The Fourier transform gas-phase infrared spectrum of pyrrole, C4H5N, has been recorded with a resolution of ca. 0.003 cm−1 in the 900-1500 cm−1 spectral region. Four fundamental bands, ν8(A1; 1016.9 cm−1), ν23(B2; 1049.1 cm−1), ν7(A1; 1074.6 cm−1), ν20(B2; 1424.4 cm−1) and the overtone band 2ν16(A1; 962.7 cm−1) have been analysed using the Watson model. The ν8 and 2ν16 bands are unperturbed; the ν7 and ν23 bands are locally perturbed, while the ν20 band is globally perturbed by weak c-Coriolis resonance. Upper state vibrational term values, and rotational and centrifugal distortion constants, have been obtained from fits using S-reduction and Ir-representation as well as A-reduction and IIIr-representation. A set of ground state rotational and centrifugal distortion constants using A-reduction was obtained from a simultaneous fit of ground state combination differences from all five bands and previous microwave and millimetre-wave data.  相似文献   

14.
This work presents sound insulation and sound reflection measurements conducted over sonic crystal noise barriers according to the European standards EN 1793-2, EN 1793-5 and EN 1793-6. In most of the reference literature, sound insulation and reflection properties of sonic crystals are measured or a diffuse sound field or in a direct sound field including the top and side edge diffraction effects together with the transmitted (or reflected) components. The aim of this work is to perform free-field measurements over a real-sized sample in order to window out all diffraction components and to verify the points of strength and weakness of the application of standardised measurements to sonic crystals. Diffuse field measurements in laboratory are also done for comparison purposes. Since the target frequency range for traffic noise spectrum is centred at around 1000 Hz, a finite element based parametric investigation is performed to design unit cells capable of generating band gaps in the one-third octave bands ranging from 800 Hz to 1250 Hz. Then, 3 × 3 m sonic crystal noise barriers are installed in the Laboratory of the University of Bologna and sound insulation and sound reflection measurements are performed according to the mentioned active standards for normal incidence. Sound insulation is measured for diffuse incidence too. The two methods give different results. The method more directly comparable to calculations is the free-field one. However, if on the one hand the application of a time window allows to compute the transmitted or reflected component only, on the other hand the time window itself limits the maximum width of the sample for which all reflections of the n-th order having a significant spectral content are included, and thus results critical in the analysis of this kind of noise barriers. Nevertheless, the standardised measurements allow a direct comparison between the performance of sonic crystals and common noise barriers.  相似文献   

15.
The microwave spectra of the gauche conformer of perfluoro-n-butane, n-C4F10, of perfluoro-iso-butane, (CF3)3CF, and of tris(trifluoromethyl)methane, (CF3)3CH, have been observed and assigned. The rotational and centrifugal distortion constants for gauche n-C4F10 are: A = 1058.11750(7) MHz, B = 617.6832(1) MHz, C = 552.18794(1) MHz, ΔJ = 0.0257(5) kHz, δJ = 0.0052(3) kHz. A C-C-C-C dihedral angle, ω, of ∼55° has been determined. These values agree well with those obtained from a coupled cluster (CCSD/cc-PVTZ) calculation. The rotational and centrifugal distortion constants for iso-C4F10 and iso-C4HF9 are: Bo = 816.4519(4) MHz, DJ = 0.023(2) kHz, and Bo = 903.6985(25) MHz, DJ = 0.043(4) kHz, respectively. The dipole moment of iso-C4F10 and iso-C4HF9 have been measured and found to be 0.0338(8) and 1.69(9) D, respectively.  相似文献   

16.
This study examines the loudness of bandpass noises with center frequencies of 250, 500 and 1000Hz while changing the autocorrelation function (ACF). The bandwidth of the source signal was altered with a 2068 dB/octave sharp filter to control the ACF of the source signal. The scale values of loudness were obtained using a paired-comparison method. It is shown that the loudness of the bandpass noises inside the critical band is not constant. The loudness of the pure tone is greater than that of sharply filtered noises. The loudness of the bandpass noises increases with increasing effective duration of the ACF (τe) of the source signal.  相似文献   

17.
The study reports on the relevancy and accuracy of using mobile phones in participatory noise pollution monitoring studies in an urban context. During one year, 60 participants used the same smartphone model to measure environmental noise at 28 different locations in Paris. All measurements were performed with the same calibrated application. The sound pressure level was recorded from the microphone every second during a 10-min period. The participants frequently measured the evolution of the sound level near two standard monitoring sound stations (in a square and near a boulevard), which enables the assessment of the accuracy and relevancy of collected acoustic measurements. The instantaneous A-weighting sound level, energy indicators such as LA,eq, LA10, LA50 or LA90 and event indicators such as the number of noise events exceeding a certain threshold Lα (NNEL ? Lα) were measured and compared with reference measurements. The results show that instantaneous sound levels measured with mobile phones correlate very well (r > 0.9, p < 0.05) with sound levels measured with a class 1 reference sound level meter with a root mean square error smaller than 3 dB(A). About 10% of the measurements for the boulevard location (respectively 20% for the square) were inaccurate (r < 0.3, p < 0.05). Nevertheless, mobile phone measurements are in agreement for the LA50 and the LA90 acoustic indicators with the fixed station (4-m high) measurements, with a median deviation smaller than 1.5 dB(A) for the boulevard (respectively 3 dB(A) for the square).  相似文献   

18.
Fluorescence spectra of LiYF4:Pr3+ have been measured between 12,000 and 22,000 cm−1 under pressures up to 10 GPa. In total, 25 crystal field energy levels were obtained and used for the determination of free-ion and crystal field parameters under pressure. According to the nephelauxetic effect, the free-ion parameters decrease with increasing pressure. The relative decrease is larger for the Slater than for the spin-orbit coupling parameter. This behavior is consistent with former studies on Pr3+ in different crystals and can be explained by a special covalency model. According to an effective D2d symmetry, five crystal field parameters B02(f,f), B04(f,f), B44(f,f), B06(f,f), and B46(f,f) are non-zero. The pressure-induced changes of these parameters have been determined up to the maximum pressure of 10 GPa. In order to improve the calculation of the crystal field levels, the configuration interactions with the 4f16p1 configuration have been taken into account. The effect of these interactions are also analyzed under pressure and distinct improvements of the energy level calculations have been obtained.  相似文献   

19.
The present paper reports the effect of Pb impurity (low ∼2 at% and high ∼10 at%) on the ac conductivity (σac) of a-Ge20Se80 glass. Frequency-dependent ac conductance and capacitance of the samples over a frequency range ∼100 Hz to 50 kHz have been taken in the temperature range ∼268 to 358 K. At frequency 2 kHz and temperature 298 K, the value of σac increases at low as well as at higher concentration of Pb. σac is proportional to ωs for undoped and doped samples. The value of frequency exponent (s) decreases as the temperature increases. The static permittivity (εs) increases at both Pb concentrations. These results have been explained on the basis of some structural changes at low and higher concentration of Pb impurity.  相似文献   

20.
High-resolution infrared spectra of boron trifluoride, enriched to 99.5 at. % 11B, have been measured from 400 to 1650 cm−1. In that region we have identified and analyzed 16 absorption bands attributed to the three fundamental bands, two combination bands, 10 hot bands, and one difference band. All possible states were accessed in this region through direct transitions either from the ground state or as hot bands from thermally populated levels. The spectral resolution of the measurements varied from 0.0015 to 0.0020 cm−1. An improved set of ground state rotational constants and rovibrational constants for the infrared-active fundamental vibrations have been determined from over 32 000 assigned transitions. This study resulted in the first direct characterization of the infrared-inactive ν1 state of 11BF3 leading to values for ν1, , and of 885.843205(24), 0.000678548(53), and 0.000337564(66) cm−1, respectively. The Fermi resonance perturbation between the E′ states ν3 and 3ν4 (l = ±1) was further elucidated by observation of hot band transitions to both the 3ν4 (l = ±1) and 3ν4 (l = ±3) states. Several other resonances were also found including the weak rotational interaction, between the state 2ν2 and the E′ state of ν1 + ν4.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号