共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
为了改进管道中高阶模式声波的有源控制效果,研究了壁面分布次级声源的空间分布优化问题。首先提出管道中次级声源独立控制高阶模式声波的理论模型。然后推导次级声源在管道中各方向上空间分布对控制高阶模式声波的贡献,得到了次级声源空间分布的优化准则。通过将空间分布离散化,采用最小化管道中声能流的控制策略得到次级声源的最优驱动强度。最后通过数值仿真对比最优驱动强度时各种次级声源空间分布对控制性能的影响,验证了通过优化次级声源空间分布能显著提高控制效果。仿真结果表明,当次级声源分布于管道所有壁面且沿管道轴向分布范围较大时,高阶模式的控制效率最高。 相似文献
4.
5.
This paper deals with the global reduction of axial flow fan noise in ducts in a building using a hybrid passive-active noise control method. The effectiveness of using an infra-red device as a reference signal source is also investigated. It is shown that using such a hybrid noise control system over an axial-flow fan reduces the overall sound pressure level by 5 dB(A) in the surrounding environment and global control of the blade passing frequency can also be achieved. This paper also shows that using an infra-red device as a reference signal source produces marginally better control as compared with using a microphone reference sensor. Moreover, long term stability is guaranteed and the possibility of acoustic feedback is eliminated. 相似文献
6.
The purpose of this work is to study computationally the possibility of the application of a hybrid active noise control technique for magnetic resonance imaging (MRI) acoustic noise reduction. A hybrid control system combined with both feedforward and feedback loops embedded is proposed for potential application on active MRI noise reduction. A set of computational simulation studies were performed. Sets of MRI acoustic noise emissions measured at the patient's left ear location were recorded and used in the simulation study. By comparing three different control systems, namely, the feedback, the feedforward and the hybrid control, our results revealed that the hybrid control system is the most effective. The hybrid control system achieved approximately a 20-dB reduction at the principal frequency component. We concluded that the proposed hybrid active control scheme could have a potential application for MRI scanner noise reduction. 相似文献
7.
8.
9.
Active noise control (ANC) systems employing adaptive filters suffer from stability issues in the presence of impulsive noise. New impulsive noise control algorithms based on filtered-x recursive least square (FxRLS) algorithm are presented. The FxRLS algorithm gives better convergence than the filtered-x least mean square (FxLMS) algorithm and its variants but lacks robustness in the presence of high impulsive noise. In order to improve the robustness of FxRLS algorithm for ANC of impulsive noise, two modifications are suggested. First proposed modification clips the reference and error signals while, the second modification incorporates energy of the error signal in the gain of FxRLS (MGFxRLS) algorithm. The results demonstrate improved stability and robustness of proposed modifications in the FxRLS algorithm. However, another limitation associated with the FxRLS algorithm is its computationally complex nature. In order to reduce the computational load, a hybrid algorithm based on proposed MGFxRLS and normalized step size FxLMS (NSS-FXLMS) is also developed in this paper. The proposed hybrid algorithm combines the stability of NSS-FxLMS algorithm with the fast convergence speed of the proposed MGFxRLS algorithm. The results of the proposed hybrid algorithm prove that its convergence speed is faster than that of NSS-FxLMS algorithm with computational complexity lesser than that of FxRLS algorithm. 相似文献
10.
In the adaptive feedback active noise control system based on the internal model control (IMC) structure, the reference signal is regenerated by synthesizing the error signal and the secondary signal filtered with the estimation of the secondary path, hence more computation load and extra programming are required. Motivated by the engineering truth that the primary noise cannot be completely cancelled in most practical active noise control applications and the error signal still contains some portions of the primary noise, a simplified adaptive feedback active noise control system is proposed in this paper, which adopts the error signal directly as the reference signal in an adaptive feedforward control system and utilizes the leaky filtered-x LMS algorithm to update the controller. The convergence properties of the proposed system are investigated and its advantages are discussed by comparing with other feedback control systems as well as the weakness. Finally, simulations and experiments are carried out to demonstrate the effectiveness of the proposed system. 相似文献
11.
MAA Dah-You 《声学学报:英文版》1994,(2)
I.IntroductionThereverberantnoisesmaybereducedwithanactivenoisecontrol(ANC)systcmformedbyacornermicrophonc-amplifier-1oudspcakersystemina.oom.lllThismeth-odbascdonthenormalmodccancelingprincip1chasalreadybeenclarifiedbothinthco-ryandexperimcnts,andthclimitationandpotcntialityofitsapp1icationalsodiscussedinapreviouspaper.Thediscussionsinthepastlimitedmost1ytothesteadyconditionofnoiscfield,andthisisextendedtothetransientcondihoninthcprcsentwork,viz.thein-llucnceofthecornerANCsystemwhenthenois… 相似文献
12.
13.
14.
15.
Based on the analysis of active noise control system with multi-channel monopole secondary sources, a kind of compound secondary source is proposed in this paper. The proposed compound secondary source consists of two closely located monopole sources with their distance much smaller than a wavelength. The characteristics of the compound source are analyzed, and the performances of the active noise control system with the compound secondary sources on the monopole primary sound field and sound radiated by a plate are investigated both numerically and experimentally. It has been found that the proposed compound secondary sources control system can provide higher noise reduction for free field noise radiation control with the same number of control channels. It is shown that the better performance in noise reduction of the compound secondary sources control system is mainly due to the directivity of the secondary sources where the energy radiation pattern of the compound sources is similar to that of the primary sources. 相似文献
16.
17.
Jing Yuan 《Applied Acoustics》2007,68(1):86-96
Feedforward controllers are used in many active noise control (ANC) systems to generate destructive interference in noise fields. An ideal feedforward ANC controller should have an infinite impulse response (IIR) transfer function, but most available feedforward ANC controllers have finite impulse responses (FIR) instead. The main reason is related to the adaptation algorithms of ANC systems. In general, adaptive FIR filters converge faster with guaranteed stability. In this study, the adaptive Laguerre filter is proposed and tested in an ANC application with positive experimental effects. The new ANC controller is an IIR filter, but its adaptation is similar to that of a FIR filter with fast convergence and guaranteed stability. Detailed explanations and analysis are presented in the main text. 相似文献
18.
A systematic analysis is proposed to predict the performance of a typical feedforward single channel ANC headset in terms of the delay, especially the non-causal delay caused by different noise coming directions. First, the performance of a non-causal feedforward system for a band-limited noise is analyzed by using a simplified pure delay model, where it is found that the noise reduction bandwidth is narrowed and the maximum noise reduction is decreased with the increase of the non-causal delay. Second, a systematic method is developed, which can be used to predict the system performance with measured primary and secondary path transfer functions in most practical sound fields and to study the effects of the control filter length and the path delay on the performance. Then, the causality of a typical feedforward active noise control headset with the primary source at 0° and 90° positions in an anechoic chamber is analyzed, and the performance for the two locations predicted by the systematic analysis is shown in good agreements with the experiment results. Finally, an experiment of a typical feedforward active noise control headset in a reverberation chamber is carried out, which shows the validity of the proposed systematic analysis for other more practical sound fields. 相似文献
19.
This paper presents passive and active vibro-acoustic noise control methods for attenuating the interior noise level in box structures which can be an analogy of cabins of vehicle and aircraft. The structural intensity (SI) approach is adopted to identify the predominant vibration panels and interior noise sources for box structures. In the study, the finite element method is used to determine the structural vibration and structural intensity in the box surfaces. According to structural intensity vectors plot and structural intensity stream lines presentation, the possible effective control positions where the dampers may be attached and the active control forces may act to reduce vibration and interior noise, are identified. From the study, it can be demonstrated that the structural intensity approach and stream line presentation are possible methods for identifying the vibro-acoustic interior noise source and predominant panels which may be modified to reduce the interior noise level. The structural intensity methodology, passive and active noise control results can be extended to the further study of the vibration and interior noise control of actual cabins of vehicles and aircraft. 相似文献
20.
Characteristics of radiation impedance and its inducing variation of electrical impedance for a controllable source have been investigated. An impedance-based error criterion has been proposed and its application to active noise control is demonstrated through a coil driven loudspeaker. A general formula of radiation impedance is derived for two control strategies, according to the criterion of total acoustic power output. The radiation impedances of some commonly used sound sources are calculated. We discuss in detail the relation between variation of the input electrical impedance and radiation impedance for the two control strategies. An AC-bridge circuit is designed to measure the weak variation of electrical impedance resulted from radiation impedance. The input electrical impedance of a loudspeaker was measured and the experimental result is consistent with that of theoretical analysis. An impedance-based error criterion is proposed since the AC-bridge relative output is unique for a certain control strategy. The implementation of this criterion applied to an active control system is analyzed by simulations. An analogue control system is set up and experiments are carried out in a semi-anechoic chamber to verify the new control approach. 相似文献