首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The present work describes the optimisation and characterization of poly(sodium 4-styrenesulfonate)-coated thin mercury film electrodes (PSS-TMFE) for the direct analysis of trace metals in estuarine waters by square-wave anodic stripping voltammetry (SW-ASV). The morphology, thickness and ion exchange ability of the poly(sodium 4-styrenesulfonate) coatings onto glassy carbon were evaluated and these features particularly favoured the incorporation of cationic species, such as dopamine or lead cation. For the case of the heavy metal cations, a simple, sensitive and very reproducible methodology for their SW-ASV analysis could be developed. In fact, with the PSS-TMFE, a significant increase in the sensitivity of the ASV determination of lead was obtained compared both to the uncoated TMFE (ca. 82%) as well as to Nafion-coated electrodes of similar thickness (ca. 43-49%). Furthermore, the permselectivity of the poly(sodium 4-styrenesulfonate) coatings, based both on electrostatic interaction and molecular size, leads to an improved anti-fouling ability against surfactant species. The analytical usefulness of the poly(sodium 4-styrenesulfonate)-coated thin mercury film electrodes is demonstrated by application to the direct ASV determination of trace heavy metals at the low nanomolar level, in estuarine waters with moderate contents of dissolved organic matter, where the uncoated TMFE failed due to fouling.  相似文献   

2.
This work aimed to produce improved polymer coatings for the modification of thin mercury film electrodes (TMFEs). The goal is to obtain sensitive, reproducible, mechanically stable and antifouling devices suitable for the determination of trace metal cations in complex media. Therefore, novel mixed coatings of two sulfonated cation-exchange polymers of dissimilar characteristics-Nafion (NA) and poly(sodium 4-styrenesulfonate) (PSS)-were produced by solvent evaporation onto glassy carbon electrodes. The effect of the mass ratio (NA:PSS) on the film morphology was studied by scanning electron microscopy, revealing the formation of biphasic polymer systems, where PSS bead-shaped clusters appeared randomly dispersed into a uniform and compact NA environment. The permselectivity/ion-exchange features of the mixed films onto glassy carbon were evaluated using cathecol, urate, and dopamine. To allow trace metal analysis, thin mercury films were plated through the NA/PSS coatings, being the reproducibility and ion-exchange features of the mixed coatings-TMFE evaluated using lead ions. The best NA/PSS coating was found for the mass ratio of 5.3. Analytical performance of the NA/PSS-TMFE yielded a detection limit of 5.5 nM (3sigma), and the application of this modified electrode to an untreated polluted estuarine water sample produced significant improvements in the quality of the signal compared with that for a bare TMFE.  相似文献   

3.
Brett CM  Fungaro DA 《Talanta》2000,50(6):1223-1231
Mercury-thin film electrodes coated with a thin film of poly(ester sulphonic acid) (PESA) have been investigated for application in the analysis of trace heavy metals by square wave anodic stripping voltammetry using the batch injection analysis (BIA) technique. Different polymer dispersion concentrations in water/acetone mixed solvent are investigated and are characterised by electrochemical impedance measurements on glassy carbon and on mercury film electrodes. The influence of electrolyte anion, acetate or nitrate, on polymer film properties is demonstrated, acetate buffer being shown to be preferable for stripping voltammetry applications. Although stripping currents are between 30 and 70% less at the coated than at bare mercury thin film electrodes, the influence of model surfactants on stripping response is shown to be very small. The effect of the composition of the modifier film dispersion on calibration plots is shown; however, detection limits of around 5 nM are found for all modified electrodes tested. This coated electrode is an alternative to Nafion-coated mercury thin film electrodes for the analysis of trace metals in complex matrices, particularly useful when there is a high concentration of non-ionic detergents.  相似文献   

4.
Batch-injection analysis exhibits the advantages of rapid and simple electroanalysis of microlitre samples. Nafion-coated mercury thin film electrodes have been evaluated for use in batch-injection analysis with anodic stripping voltammetry (BIA-ASV). The advantages of Nafion-coated electrodes in reducing electrode contamination by components of complex matrices are combined with the analysis of small microlitre sample volumes. The measurement of traces of lead and cadmium is used to illustrate the approach. An optimised procedure for formation of Nafion-coated mercury thin film electrodes is evolved. The relative sensitivity for BIA-ASV at electrodes with and without Nafion coatings is 0.9 and 0.8 for cadmium and lead respectively; detection limits are 2 x 10(-9) M and 4 x 10(-9) M. Studies were done concerning the influence of surfactants and their effect was found to be much less with the Nafion film coating. Applications to real environmental samples are demonstrated.  相似文献   

5.
The effect of various organic compounds on the Nafion/chelating agent mercury film electrodes (NCAMFEs) in square-wave anodic-stripping voltammetry (SWASV) is explored. Two chelating agents used to prepare the NCAMFEs are dimethylglyoxime and 2,2'-bipyridyl. Triton X-100, sodium dodecyl sulfate, albumin, gelatin, starch, camphor, and humic acid are used as model organic compounds, while cadmium, lead, and copper are used as test metal ions. The NCAMFEs are considerably more resistant to organic interferences than the Nafion-coated mercury film electrode. The implications of these interferences for the reliability and feasibility of stripping measurements using the NCAMFEs in real samples are discussed. Results presented for untreated urine and natural water samples demonstrate the analytical utility of the NCAMFEs in SWASV.  相似文献   

6.
Bismuth film electrodes are shown to be very attractive alternatives to common mercury electrodes used for adsorptive stripping voltammetric measurements of trace nickel in the presence of the dimethylglyoxime complexing agent. Variables affecting the response have been assessed and optimized. Such optimization resulted in a favorable and highly stable stripping response, with good linearity (up to 80 μg L−1) and precision (RSD=1.8%), and a low detection limit (0.8 μg L−1 with 180 s adsorption). The adsorptive stripping performance makes the bismuth film electrode very attractive for measurements of trace metals that cannot be plated electrolytically, and should address possible restrictions on the use of mercury electrodes.  相似文献   

7.
The combined effects of pH, thiocyanate ion and deposition potential in the characteristics of thin mercury film electrodes plated on glassy carbon surfaces are evaluated. Charges of deposited mercury are used as an experimental parameter for the estimation of the effectiveness of the mercury deposition procedure. The sensitivity of the anodic stripping voltammetry (ASV) method for the determination of lead at in situ and at ex situ formed thin mercury films are also examined. It was concluded that, in acidic solutions (pH 2.5-5.7) and fairly negative deposition potentials, e.g. −1.3 to −1.5 V, thiocyanate ion promotes the formation of the mercury film, in respect both to the amount of deposited mercury and to the mercury deposition rate. Also, the mercury coatings produced in thiocyanate solutions are more homogeneous, as depicted by microscopic examinations. In the presence of thiocyanate there is no obvious advantage of using high concentrations of mercury and/or high deposition times for the in situ and ex situ preparation of the mercury film electrodes. The optimised thin mercury film electrode ex situ prepared in a 5.0 mM thiocyanate solution of pH 3.4 was successfully applied to the ASV determination of lead and copper in acidified seawater (pH 2). The limit of detection (3σ) was 6×10−11 M for lead and 2×10−10 M for copper for a deposition time of 5 min. Relative standard deviations (R.S.D.s) of <1.2% were obtained for determinations at the nanomolar of concentration level.  相似文献   

8.
To improve reproducibility, stability and sensitivity, a bismuth (Bi) thin film was coated on glassy carbon (GC) substrates which surfaces were modified with a porous thin layer of polyaniline (PANI) via multipulse potentiostatic electropolymerization to form Bi/PANI/GC electrodes (Bi/PANI/GCEs). The Bi/PANI/GCEs were used successfully for simultaneous detection and determination of Cd2+ and Pb2+ ions, and various parameters were studied with reference to square wave anodic stripping voltammetric (SWASV) signals. The experimental results depicted that the environment‐friendly Bi/PANI/GCEs had the ability to rapidly monitor trace heavy metals even in the presence of surface‐active compounds.  相似文献   

9.
Glassy carbon electrodes modified with coatings of poly-[1-methyl-3-(pyrrol-1-ylmethyl)pyridinium], poly-MPP, were employed for preconcentrating and detecting the anionic complex HgCl4(2-), which is the prevailing inorganic Hg(II) species in salt waters such as the pore-waters of sediments here examined. The application of ion-exchange voltammetry at poly-MPP coated electrodes in combination with an in situ pore-water sampler allowed the measurement of concentration vs. depth profiles for mercury dissolved in the pore-waters of a salt-marsh and of a mud-flat located in a polluted area of the Venice Lagoon. The trends of the mercury profiles are discussed in comparison with the trends measured from the same location for other trace metals (Zn, Cd, Cu and Pb) and reduced species such as S(-II) and Fe(II).  相似文献   

10.
This work describes a novel type of bismuth electrode for stripping voltammetry based on coating a silicon substrate with a thin bismuth film by means of sputtering. The bismuth-based sensors were characterized by optical methods (scanning electron microscopy (SEM), atomic force microscopy (AFM) and X-ray diffraction (XRD)) and as well as by linear sweep voltammetry. Subsequently, the electrodes were tested for the detection of low concentrations of trace metals (Cd(II), Pb(II) and Ni(II)) by stripping voltammetry. Well-formed stripping peaks were observed for trace concentrations of the target analytes demonstrating “proof-of-principle” for these sensors. This type of electrochemical device, utilizing thin-film technology for the formation of the bismuth film, holds promise for future applications in trace metal analysis.  相似文献   

11.
Differential pulse anodic stripping voltammetry (DPASV) using a Nafion-coated thin mercury film electrode (NCTMFE) was implemented to determine the dissolved copper speciation in saline estuarine waters containing high concentrations of dissolved organic matter (DOM). The study used model ligands and estuarine water from San Francisco Bay, California, USA to demonstrate that the NCTMFE is more effective at distinguishing between electrochemically inert and labile copper species when compared to the conventional thin mercury film electrode (TMFE). Copper titration results verify that the NCTMFE better deals with high concentrations of DOM by creating a size-exclusion barrier that prevents DOM from interacting with the mercury electrode when performing copper speciation measurements. Pseudovoltammograms were used to illustrate that copper complexes found in natural waters were more apt to be electrochemically inert at the NCTMFE relative to the TMFE when subjected to high negative overpotentials. Copper speciation results using the NCTMFE from samples collected in San Francisco Bay estimated that >99.9% of all copper was bound to strong copper-binding ligands. These L1-class ligands exceeded the concentration of total dissolved copper in all samples tested and control the equilibrium of ambient [Cu2+] in the San Francisco Bay estuary.  相似文献   

12.
This work reports on the fabrication, characterization and applications of Nafion-coated bismuth-film electrodes (NCBFE's) for the determination of trace metals by anodic stripping voltammetry (ASV). A NCBFE was typically prepared by first applying a 5 microl drop of a 1% Nafion solution onto the surface of a glassy-carbon rotating-disk electrode. After evaporation of the solvent, the Bi film was plated on the electrode in situ(i.e. by spiking the sample with 1000 microg l(-1) of Bi(iii) and simultaneous electrolytic deposition of the metal ions and bismuth film on the electrode surface at -1.4 V) or ex-situ(i.e. by electrolytic deposition of the bismuth film in a separate solution containing 1000 microg l(-1) of Bi(iii), followed by the ASV measurement step in the sample solution). Various fabrication and operational parameters were thoroughly investigated and discussed in terms of their effect on the ASV signals. It was found that this voltammetric sensor was suitable for the determination of metals at trace levels by square-wave ASV (SWASV) due to its multi-element detection potential, improved analytical sensitivity, high resistance to surfactants, low cost, ease of fabrication, robustness, speed of analysis and low toxicity (as compared to traditional mercury electrodes). In the presence of 4 mg l(-1) of Triton X-100, the NCBFE afforded a 10-fold peak height enhancement for the Pb peak and a 14-fold enhancement for the Cd peak over a bare BFE while the determination of Zn was feasible only on the NCBFE. The limits of detection (at a signal-to-noise ratio of 3) were 0.1 microg l(-1) for Cd and Pb and 0.4 microg l(-1) for Zn for a deposition time of 10 min. Finally, the electrode was applied to different real samples (tap-water, urine and wine) for the analysis of trace metals with satisfactory results.  相似文献   

13.
A mercury–carbon electrode formed in situ on a carbon fiber support (at a mercury film thickness of 0.33 nm and a polarization potential sweep rate of 100–1000 V/s) exhibited properties typical of an indifferent solid electrode. They specifically affect the detected analytical signals of metals soluble in mercury (Zn, Cd, and Pb). The value of this signal depends on both the analyte concentration in solution and the concentrations of other metals that can be electrolytically accumulated in a thin mercury film. Based on this property, one can determine nanomolar concentrations of the above metals with electrolytic accumulation for 20–200 s.  相似文献   

14.
The potential application of commercial screen-printed gold electrodes (SPGEs) for the trace determination of lead, copper, and mercury in fuel bioethanol is demonstrated. Samples were simply diluted in 0.067 mol L−1 HCl solution prior to square-wave anodic stripping voltammetry (SWASV) measurements recorded with a portable potentiostat. The proposed method presented a low detection limit (<2 μg L−1) for a 240 s deposition time, linear range between 5 and 300 μg L−1, and adequate recovery values (96–104%) for spiked samples. This analytical method shows great promise for on-site trace metal determination in fuel bioethanol once there is no requirement for sample treatment or electrode modification.  相似文献   

15.
A new sensor has been developed for the simultaneous detection of cadmium, lead, copper and mercury, using differential pulse and square wave anodic stripping voltammetry (DPASV and SWASV) at a graphite–polyurethane composite electrode with SBA‐15 silica organofunctionalized with 2‐benzothiazolethiol as bulk modifier. The heavy metal ions were preconcentrated on the surface of the modified electrode at ?1.1 V vs. SCE where they complex with 2‐benzothiazolethiol and are reduced to the metals, and are then reoxidized. Optimum SWASV conditions lead to nanomolar detection limits and simultaneous determination of Cd2+, Pb2+, Cu2+ and Hg2+ in natural waters was achieved.  相似文献   

16.
Conditions for the formation of a stable and reproducible thin-film mercury microdrop cover on electrodes from carbon glass ceramics, carbon glass, and graphite are proposed. The influence of various factors on the parameters of signals from cadmium (II), lead (II), and copper (II) is studied by stripping voltammetry with linear, differential-pulse, sinusoidal, and square-wave potential sweep. The parameters of the stripping voltammetric experiment are optimized. The value of RSD in determining the specified modeling trace components did not exceed 15%. Approaches to the multicomponent stripping voltammetric analysis of waters are proposed.  相似文献   

17.
In the perspective of in-field stripping analysis of heavy metals, the use and disposal of toxic mercury solutions (necessary to plate a mercury film on a carbon electrode surface) presents a problem. The aim of this work was the development of mercury coated screen-printed electrodes previously prepared in the lab and ready to use in-field. Thus some commercially available polymers like Nafion®, Eastman Kodak AQ29®, and Methocel® were investigated as mercury entrapping systems for electrochemical stripping analysis of heavy metals. Screen-printed disposable cells with a silver pseudo-reference electrode, a graphite counter electrode, and a graphite working electrode were used. To modify the sensor, the polymer solution was cast onto the carbon working electrode surface. Detection limits of 0.8 and 1 μg/L were obtained for lead and cadmium respectively. Since Methocel® based electrodes showed the best performance, they were used for the analysis of real samples. The results were compared with those obtained using a classical thin mercury film electrode and ICP spectroscopy.

All the experiments reported here were performed in un-deareated solutions as required for in-field analysis.  相似文献   

18.
The deposition of polyelectrolyte multilayer films (PEMs) appears more and more as a versatile tool to functionalize a broad range of materials with coatings having controlled thicknesses and properties. To increase the control over the properties of such coatings, a good knowledge of their deposition mechanism is required. Since Cohen Stuart et al. (Langmuir 18 (2002) 5607-5612) showed that the adsorption of one polyelectrolyte could induce desorption of polyelectrolyte complexes instead of regular deposition, more and more findings highlight peculiarities in the deposition of such films. Herein we demonstrate that the association of sodium polyphosphate (PSP) as the polyanion and either poly(-L-lysine hydrobromide) (PLL) or poly(allylamine chloride) (PAH) as the polycations may lead to non-monotonous film deposition as a function of time. Complementary, films containing PSP and PLL can be obtained from a (PLL-HA)(n) template films after the exchange of HA (hyaluronic acid) from the sacrificial template by PSP from the solution. This exchange is accompanied by pronounced film erosion. However, when starting from a (PAH-HA)(n) template, the film erosion and exchange due to the contact with PSP is by far less pronounced, nevertheless the film morphology changes. These findings show that the nature of the polycation used to deposit the PEM film may have a profound influence of the film's response to a competing polyanion.  相似文献   

19.
Hoyer B  Jensen N 《Talanta》1994,41(3):449-453
The signal stability of the Nafion-coated thin mercury film electrode (NCTMFE) was studied by using cadmium and lead as test analytes and differential pulse anodic stripping voltammetry as detection method. In particular, the effect of the casting solvent and the curing procedure employed in the preparation of the polymer film was examined. Best results were obtained with N,N-dimethylacetamide as casting solvent and a two-step curing procedure in which the polymer was evaporated to dryness at 55 degrees and cured at 105 degrees with a hot-air gun. Mercury plating was performed ex situ. An NCTMFE prepared in this manner has a better signal stability than ex situ-plated as well as in situ-plated conventional mercury film electrodes.  相似文献   

20.
The presence of trace metals in car fuels plays an important role in the engine maintenance. In addition, these metals contribute for the environmental contamination in big cities and their control is necessary. Square Wave Stripping Voltammetry (SWSV) is a very sensitive technique for elemental trace determination and was applied for ethanol fuel analysis. The first studies were done searching for the best conditions for copper determination in alcoholic medium, utilizing gold electrodes. During these studies, the possibility of the simultaneous determination of copper and lead in the same experiment was observed. Two procedures for the analysis of these metals were adopted: The direct quantification of metals in alcohol–water mixtures and a second way that involves the evaporation of the organic solvent and re-suspension of the ions with water+electrolyte. Good recovery values were obtained for synthetic samples spiked with known amounts of metals. The results obtained for the two methods were in good agreement. The detection limits for copper and lead in 75% ethanol–water ratio solution were calculated as 120 and 235 ng l−1, respectively, for 15-min deposition time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号