首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The fragmentation reactions of the protonated dipeptides Gly-Arg and Arg-Gly have been studied using collision-induced dissociation (CID) in a quadrupole ion trap, by in-source CID in a single-quadrupole mass spectrometer and by CID in the quadrupole cell of a QqTOF mass spectrometer. In agreement with earlier quadrupole ion trap studies (Farrugia, J. M.; O'Hair, R. A. J., Int. J. Mass Spectrom., 2003, 222, 229), the CID mass spectra obtained with the ion trap for the MH(+) ions and major fragment ions are very similar for the two isomers indicating rearrangement to a common structure before fragmentation. In contrast, in-source CID of the MH(+) ions and QqTOF CID of the MH(+), [MH - NH(3)](+) and [MH <23 HN = C(NH(2))(2)](+) ions provide distinctly different spectra for the isomeric dipeptides, indicating that rearrangement to a common structure has not occurred to a significant extent under these conditions even near the threshold for fragmentation in the QqTOF instrument. Clearly, under normal operating conditions significantly different fragmentation behavior is observed in the ion trap and beam-type experiments. This different behavior probably can be attributed to the shorter observation times and concomitant higher excitation energies in the in-source and QqTOF experiments compared to the long observation times and lower excitation energies relevant to the ion trap experiments. Based largely on elemental compositions derived from accurate mass measurements in QqTOF studies fragmentation schemes are proposed for the MH(+), [MH - NH(3)](+), and [MH - (HN = C(NH(2))(2))](+) ions.  相似文献   

2.
Hang W  Lewis C  Majidi V 《The Analyst》2003,128(3):273-280
Construction details and performance evaluation of a radio frequency (rf)-only quadrupole ion guide for use with an electrospray ionization time-of-flight mass spectrometer is presented in this paper. Angiotensin III and cytochrome c were used in these experiments to investigate the ion transmission properties of the rf-only quadrupole for different m/z species. In addition, influence of ion kinetic energies along with the characteristic fragmentation due to collision induced dissociation (CID) were studied. These experiments demonstrate that the transmissions of different m/z ions were not only dependent on the frequency and magnitude of the rf waveform, which is similar to a high vacuum rf-only quadrupole ion guide, but also on the pressure inside the quadrupole chamber. For the pressure range tested, low m/z ions are better focused with increasing pressure. As expected, transmission of ions are subject to space charge limitations when significant numbers of ions are focused on the axis of the quadrupole. It is also observed that CID results are related to transverse motion and longitude motion of ions inside the quadrupole region. Consequently, CID is useful for fragmentation of linear peptides and it is not effective (in present configuration) for large bulky proteins. The kinetic energy of ions that enter the repelling region of the TOFMS is ultimately determined by the ensemble effect resulting from the dc bias potential of the quadrupole (the dominant factor), skimmer-2, pressure inside the quadrupole chamber, and jet expansion. While this system is tested with an ESI source, the operational principle and design criteria are directly applicable for improving other atmospheric pressure ionization sources with time-of-flight mass analyzers such as an inductively coupled plasma ion source.  相似文献   

3.
Recent advancements in mass spectrometry including data-dependent scanning and high-resolution mass spectrometry have aided metabolite profiling for non-radiolabeled xenobiotics. However, narrowing down a site of metabolism is often limited by the quality of the collision-induced dissociation (CID)-based precursor ion fragmentation. An alternative dissociation technique, higher energy collisional dissociation (HCD), enriches compound fragmentation and yields 'triple-quadrupole-like fragmentation'. Applying HCD along with CID and data-dependent scanning could enhance structural elucidation for small molecules. Liquid chromatography/multi-stage mass spectrometry (LC/MS(n) ) experiments with CID and HCD fragmentation were carried out for commercially available compounds on a hybrid linear ion trap orbital trap mass spectrometer equipped with accurate mass measurement capability. The developed method included stepped normalized collision energy (SNCE) parameters to enhance MS fragmentation without tuning for individual compounds. All the evaluated compounds demonstrated improved fragmentation under HCD as compared with CID. The results suggest that an LC/MS(n) method that incorporated both SNCE HCD- and CID-enabled precursor ion fragmentation afforded comprehensive structural information for the compounds under investigation. A dual collision cell approach was remarkably better than one with only CID MS(n) in an orbital trap. It is evident that such an acquisition method can augment the identification of unknown metabolites in drug discovery by improving fragmentation efficiency of both the parent compound and its putative metabolite(s).  相似文献   

4.
The application of electron transfer and dipolar direct current induced collisional activation (ET‐DDC) for enhanced sequence coverage of peptide/protein cations is described. A DDC potential is applied across one pair of opposing rods in the high‐pressure collision cell of a hybrid quadrupole/time‐of‐flight tandem mass spectrometer (QqTOF) to induce collisional activation, in conjunction with electron transfer reactions. As a broadband technique, DDC can be employed for the simultaneous collisional activation of all the first‐generation charge‐reduced precursor ions (eg, electron transfer no‐dissociation or ETnoD products) from electron transfer reactions over a relatively broad mass‐to‐charge range. A systematic study of ET‐DDC induced collision activation on peptide/protein cations revealed an increase in the variety (and abundances) of sequence informative fragment ions, mainly c‐ and z‐type fragment ions, relative to products derived directly via electron transfer dissociation (ETD). Compared with ETD, which has low dissociation efficiency for low‐charge‐state precursor ions, ET‐DDC also showed marked improvement, providing a sequence coverage of 80% to 85% for all the charge states of ubiquitin. Overall, this method provides a simple means for the broadband collisional activation of ETnoD ions in the same collision cell in which they are generated for improved structural characterization of polypeptide and protein cations subjected to ETD.  相似文献   

5.
In‐source collision‐induced dissociation (CID) is commonly used with single‐stage high‐resolution mass spectrometers to gather both a molecular formula and structural information through the collisional activation of analytes with residual background gas in the source region of the mass spectrometer. However, unlike tandem mass spectrometry, in‐source CID does not involve an isolation step prior to collisional activation leading to a product ion spectrum composed of fragment ions from any analyte present during the activation event. This work provides the first comparison of in‐source CID and beam‐type CID spectra of emerging synthetic drugs on the same instrument to understand the fragmentation differences between the two techniques and to contribute to the scientific foundations of in‐source CID. Electrospray ionization–quadrupole time‐of‐flight (ESI‐Q‐TOF) mass spectrometry was used to generate product ion spectra from in‐source CID and beam‐type CID for a series of well‐characterized fentanyl analogs and synthetic cathinones. A comparison between the fragmentation patterns and relative ion abundances for each technique was performed over a range of fragmentor offset voltages for in‐source CID and a range of collision energies for beam‐type CID. The results indicate that large fragmentor potentials for in‐source CID tend to favor higher energy fragmentation pathways that result in both kinetically favored pathways and consecutive neutral losses, both of which produce more abundant lower mass product ions relative to beam‐type CID. Although conditions can be found in which in‐source CID and beam‐type CID provide similar overall spectra, the in‐source CID spectra tend to contain elevated noise and additional chemical background peaks relative to beam‐type CID.  相似文献   

6.
Analytical Chemistry Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA Ion-molecule reactions of neutral methane with analyte ions under normal methane chemical ionization conditions are discussed. Reactant ions can be generated by direct electron ionization (EI) fragmentation, chemical ionization (CI) fragmentation, or collision-induced dissociation (CID). Examples in which products of such reactions appear in mass spectra in both conventional CI sources in “beam” instruments and low pressure CI in a quadrupole ion trap are presented. Also shown is an example in which MS/MS product ions react with neutral methane used for CI in an ion trap. It is shown that it is relatively straightforward to recognize such reactions in a quadrupole ion trap and in certain cases to minimize or preclude them. Effects of various operating parameters have been investigated and are discussed.  相似文献   

7.
A commercial matrix-assisted laser desorption/ionisation time-of-flight (MALDI-ToF) instrument equipped with a curved field reflectron (CFR) was modified in order to perform collision-induced dissociation (CID) on a variety of biomolecules. The incorporation of a high-resolution ion gate together with a collision cell within the field-free region allowed tandem mass analysis (MS/MS), without the necessity to decelerate the precursor ions prior to activation. The simultaneous detection of all product ions remained possible by using the CFR. To test the MS/MS performances, ACTH (fragment 1-17), a complex high mannose carbohydrate (Man)(8)(GlcNac)(2) and a lysophosphatidylcholine lipid (18:1) were analysed on the modified instrument. Direct comparison with the low-energy product ion spectra, acquired on a MALDI quadrupole ion trap (QIT) two-stage reflectron time-of flight (ReToF) mass spectrometer, showed significant differences in the types of product ions observed. The additional ions detected were a clear indication of the high-energy fragmentation processes occurring in the collision cell.  相似文献   

8.
Using n‐butylbenzene as a test molecule, evidence is provided that fast, efficient or highly energetic collision‐induced dissociation (CID) can be achieved during the mass acquisition ramp of a commercially available quadrupole ion trap (QIT) mass spectrometer. The method of excitation is very similar to axial modulation for mass range extension except that lower amplitude waveforms are used to excite the precursor ions within the trap instead of ejecting them from the trap. ITSIM simulations verify that fast kinetic excitation followed by kinetic‐to‐internal energy transfer occurs on the rapid time‐scale required for the recapture and mass analysis of product ions during the mass acquisition ramp. CID efficiencies larger than 50% can be obtained using this new approach and ratios of Th 91/92 of n‐butylbenzene fragment ions as large as 9 are possible, albeit at significantly reduced efficiencies. These very large ratios indicate an internal energy above 7 eV for the precursor ions indicating that fragmentation of larger ions could also be possible using this new approach. The main benefits of the new method are that no extra time is required for fragmentation or cooling and that on‐resonance conditions are guaranteed because the ions' secular frequencies are swept through the fixed frequency of excitation. Also presented are the effects of experimental variables such as excitation frequency, excitation amplitude and scan rate on the CID efficiencies and energetics. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

9.
The transmission efficiency of precursor and product ions decreases significantly at lower collision energies in a four-sector tandem mass spectrometer. In an effort to improve the overall ion transmission in this energy regime three modifications were made in the interface region between the two stages of mass analysis. An einzel lens was inserted prior to the deceleration lens of the collision cell block to reduce the precursor ion beam diameter. The collision cel1 block was reduced in thickness while maintaining the collision path length, thus increasing the number of ions which entered and exited the gas chamber, while removing any stray electrical fields. Finally, a second active focusing element was incorporated after the collision cell block to enhance the collection efficiency of the product ions. A tandem mass spectrum of angiotensin I obtained with this interface, at a collision cell block potential of 9200 volts, exhibited classical high energy collision-induced dissociation (CID) fragmentation patterns, a precursor ion transmission of 92% and an overall CID efficiency of approximately 7.5%. These improvements have resulted in a dramatically higher overall ion transmission at high collision cell potentials as well as sufficient sensitivity in acquiring good quality CID spectra in the lower collision energy regime (i.e., 60 eV). (460-469)  相似文献   

10.
Ion activation methods for tandem mass spectrometry   总被引:7,自引:0,他引:7  
This tutorial presents the most common ion activation techniques employed in tandem mass spectrometry. In-source fragmentation and metastable ion decompositions, as well as the general theory of unimolecular dissociations of ions, are initially discussed. This is followed by tandem mass spectrometry, which implies that the activation of ions is distinct from the ionization step, and that the precursor and product ions are both characterized independently by their mass/charge ratios. In collision-induced dissociation (CID), activation of the selected ions occurs by collision(s) with neutral gas molecules in a collision cell. This experiment can be done at high (keV) collision energies, using tandem sector and time-of-flight instruments, or at low (eV range) energies, in tandem quadrupole and ion trapping instruments. It can be performed using either single or multiple collisions with a selected gas and each of these factors influences the distribution of internal energy that the activated ion will possess. While CID remains the most common ion activation technique employed in analytical laboratories today, several new methods have become increasingly useful for specific applications. More recent techniques are examined and their differences, advantages and disadvantages are described in comparison with CID. Collisional activation upon impact of precursor ions on solid surfaces, surface-induced dissociation (SID), is gaining importance as an alternative to gas targets and has been implemented in several different types of mass spectrometers. Furthermore, unique fragmentation mechanisms of multiply-charged species can be studied by electron-capture dissociation (ECD). The ECD technique has been recognized as an efficient means to study non-covalent interactions and to gain sequence information in proteomics applications. Trapping instruments, such as quadrupole ion traps and Fourier transform ion cyclotron resonance instruments, are particularly useful for the photoactivation of ions, specifically for fragmentation of precursor ions by infrared multiphoton dissociation (IRMPD). IRMPD is a non-selective activation method and usually yields rich fragmentation spectra. Lastly, blackbody infrared radiative dissociation is presented with a focus on determining activation energies and other important parameters for the characterization of fragmentation pathways. The individual methods are presented so as to facilitate the understanding of each mechanism of activation and their particular advantages and representative applications.  相似文献   

11.
The use of a hybrid triple quadrupole-linear ion trap (QqQ(LIT)) mass spectrometer system for a comprehensive study of fragmentation mechanisms is described. The anxiolytic drug, buspirone, was chosen as a model compound for this study. With the advent of a QqQ(LIT) instrument, both the traditional quadrupole and the new linear ion trap scans (LIT) could be performed in a single LC run. In the past, a sample had to be run on two different instruments, namely, a triple quadrupole instrument (QqQ) and a 3D ion trap (3D IT) to obtain similar information. With the new QqQ(LIT) technology, collision-induced dissociation (CID) occur in a quadrupole collision cell, q2, and fragment ions are trapped and analyzed in Q3 operated in LIT mode. In this work, high-sensitivity product ion spectra of buspirone were obtained from the one-stage 'Enhanced Product Ion' scan (EPI) with rich product ions and no low mass cut-off. Furthermore, detailed fragmentation pathways were elucidated by further dissociation of each of the fragment ions in the EPI spectrum using MS(3) mode in the same run. The MS(3) scan was performed by incorporating CID in q2, and trapping, cooling, isolation, and resonance-excitation in Q3 when operating in LIT mode. This approach allowed unambiguous assignment of all fragment ions quickly with fewer experiments and easier interpretation than the previous approach. The overall sensitivity for obtaining complete fragment ion data was significantly improved for QqQ(LIT) as compared with that of QqQ and 3D IT mass spectrometers. This is beneficial for structure determination of unknown trace components. The method allowed structure determination of metabolites of buspirone in rat microsomes at 1 microM concentration, which was a 10-fold lower concentration than was needed for QqQ or 3D IT instruments. The QqQ(LIT) instrument provided a simple, rapid, sensitive and powerful approach for structure elucidation of trace components.  相似文献   

12.
Collision induced dissociation (CID) in a quadrupole ion trap mass spectrometer using the conventional 30 ms activation time is compared with high amplitude short time excitation (HASTE) CID using 2 ms and 1 ms activation times. As a result of the shorter activation times, dissociation of the parent ions using the HASTE CID technique requires resonance excitation voltages greater than conventional CID. After activation, the rf trapping voltage is lowered to allow product ions below the low mass cut-off to be trapped. The HASTE CID spectra are notably different from those obtained using conventional CID and can include product ions below the low mass cut-off for the parent ions of interest. The MS/MS efficiencies of HASTE CID are not significantly different when compared with the conventional 30 ms CID. Similar results were obtained with a two-dimensional (linear) ion trap and a three-dimensional ion trap.  相似文献   

13.
Ion/ion proton transfer reactions involving mutual storage of both ion polarities in a linear ion trap (LIT) that comprises part of a hybrid triple quadrupole/linear ion trap mass spectrometer have been effected. Mutual ion storage in the x- and y-dimensions arises from the normal operation of the oscillating quadrupole field of the quadrupole array, while storage in the z-dimension is enabled by applying unbalanced radio-frequency amplitudes to opposing sets of rods of the array. Efficient trapping (>90%) is achieved for thermalized ions over periods of several seconds. Reactions were demonstrated for multiply charged protein/peptide cations formed by electrospray with anions derived from glow discharge ionization of perfluoro(methyldecalin) (PMD) introduced from the side of the LIT rod array. Doubly and singly charged protein ions are readily formed via ion/ion reactions. The parameters that affect ion/ion reactions are discussed, including the degree of RF unbalance on the LIT rods, vacuum pressure, nature of the buffer gas, reaction time, anion abundance, and the low mass cutoff for ion/ion reaction. The present system has a demonstrated upper mass-to-charge ratio limit of at least 33,000. The system also has high flexibility with respect to defining MS(n) experiments involving both collision-induced dissociation (CID) and ion/ion reactions. Experiments are demonstrated involving beam-type CID in the pressurized collision quadrupole (Q2) followed by ion/ion reactions involving the product ions in the LIT. Ion parking experiments are also demonstrated using the mutual storage ion/ion reaction mode in the LIT, with a parking efficiency over 60%.  相似文献   

14.
Recently, we demonstrated a new method, STEP (Statistical Test of Equivalent Pathways) analysis, which differentiates first-generation product ions (primary product ions) from second-generation product ions (secondary product ions) obtained in tandem mass spectrometric (MS/MS) experiments on a quadrupole ion trap mass spectrometer. The study presented here defines how to adapt the STEP method to a more routinely used mass analyzer, the triple quadrupole. New ion activation conditions were developed to adapt the STEP method to the triple quadrupole mass spectrometer using peptides and carbohydrates. The application of this method to the triple quadrupole is useful because it provides an efficient approach to differentiate primary and secondary ions on this instrument. Out of the total number of ions that were subjected to the STEP analysis, this method correctly identified 96% of ions as primary or secondary, indicating that this analysis is effective for carbohydrates and peptides undergoing collision-induced dissociation (CID) on a triple quadrupole mass spectrometer.  相似文献   

15.
Axial collision induced dissociation (CID) and high-pressure resonance CID were implemented and compared with normal low-pressure resonance CID in a miniature ion trap mass spectrometer to obtain more complete fragmentation spectra. Axial CID was realized simply by applying a potential to the discontinuous atmospheric pressure interface (DAPI) capillary without performing parent ion isolation before dissociation. High-pressure resonance CID employed a double-introduction pulse scan function, by means of which precursor ions isolated at low-pressure (<10−3 torr) were dissociated at high-pressure (0.1 torr-1 torr) with higher excitation energy, so that tandem MS of isolated precursor ions was achieved and extensive fragmentation was obtained. A simple peptide (Leu-enkephalin) and dye molecule (rhodamine B) ionized by ESI were used to investigate both methods and compare them with normal low-pressure resonance CID.  相似文献   

16.
The propensities of a series of peptide ions produced by both electrospray and atmospheric pressure matrix assisted laser desorption ionization (AP-MALDI) to fragment in an ion trap mass spectrometer under various conditions were studied in detail by measuring the extent of fragmentation of precursor ions by collision induced dissociation (CID) as a function of applied resonance excitation RF voltage. For the most basic peptides, the energy required to fragment MH+ ions generated by electrospray exceeded that required to fragment equivalent AP-MALDI ions under identical instrumental conditions; the reverse was observed for a peptide incorporating no basic residues, while peptides of intermediate basicity showed little difference between the ionization methods. This correlation between peptide basicity and the difference in the energy required to induce fragmentation of MH+ ions generated by AP-MALDI and electrospray is attributed primarily to a trend in the internal energies of the ions generated by AP-MALDI (the greater the difference in gas-phase basicities between the matrix and the analyte the greater the internal energy of the analyte ions produced). Furthermore the internal energies of ions produced by AP-MALDI, but not the equivalent ions formed by electrospray, were observed to decrease with decreasing analyte concentration. We attribute this finding to the cooling effect of endothermic dissociation of analyte ion/matrix molecule clusters following the matrix assisted laser desorption step. Time-resolved analyses (measurement of extent of fragmentation of precursor ions by CID as a function of pre-CID "cool times") revealed that cooling periods in excess of 250 ms were required to achieve internal energy equilibrium through cooling collisions with the helium buffer gas. Furthermore, these analyses demonstrated that, even after these extended cooling times, equivalent ions formed by the two ionization techniques showed different propensities to fragment. We conclude that the two different ionization techniques produce ion populations that may differ in their three-dimensional structure.  相似文献   

17.
Quaternary ammonium salts (Quats) and amines are known to facilitate the MS analysis of high molar mass polyethers by forming low charge state adduct ions. The formation, stability, and behavior upon collision-induced dissociation (CID) of adduct ions of polyethers with a variety of Quats and amines were studied by electrospray ionization quadrupole time-of-flight, quadrupole ion trap, and linear ion trap tandem mass spectrometry (MS/MS). The linear ion trap instrument was part of an Orbitrap hybrid mass spectrometer that allowed accurate mass MS/MS measurements. The Quats and amines studied were of different degree of substitution, structure, and size. The stability of the adduct ions was related to the structure of the cation, especially the amine’s degree of substitution. CID of singly/doubly charged primary and tertiary ammonium cationized polymers resulted in the neutral loss of the amine followed by fragmentation of the protonated product ions. The latter reveals information about the monomer unit, polymer sequence, and endgroup structure. In addition, the detection of product ions retaining the ammonium ion was observed. The predominant process in the CID of singly charged quaternary ammonium cationized polymers was cation detachment, whereas their doubly charged adduct ions provided the same information as the primary and tertiary ammonium cationized adduct ions. This study shows the potential of specific amines as tools for the structural elucidation of high molar mass polyethers.  相似文献   

18.
A novel tandem quadrupole mass spectrometer is described that enables gaseous collision-induced dissociation (CID) and surface-induced dissociation (SID) experiments. The instrument consists of a commercially available triple quadrupole mass spectrometer connected to an SID region and an additional, orthogonal quadrupole mass analyser. The performance of the instrument was evaluated using leucine-enkephalin, allowing a comparison between CID and SID, and with previous reports of other SID instruments. The reproducibility of SID data was assessed by replicate determinations of the collision energy required for 50% dissociation of leucine-enkephalin; excellent precision was observed (standard deviation of 0.6 eV) though, unexpectedly, the reproducibility of the equivalent figure for CID was superior. Several peptides were analysed using SID in conjunction with liquid secondary-ion mass spectrometry or electrospray; a comparison of the fragmentation of singly protonated peptide ions and the further dissociation of y-type fragments was consistent with the equivalence of the latter fragments to protonated peptides. Few product ions attributable to high-energy cleavages of amino acid side-chains were observed. The SID properties were investigated of a series of peptides differing only in the derivatization of a cysteine residue; similar decomposition efficiencies were observed for all except the cysteic acid analogue, which demonstrated significantly more facile fragmentation.  相似文献   

19.
Fixed-energy sequential tandem mass spectrometry (MS(n)) capabilities offered by quadrupole ion trap instruments have been explored in a systematic study of six isomers of Gal-Fucalpha-OBenzyl disaccharides. Under collision-induced dissociation (CID), sodiated molecular species generated in the positive-ion electrospray ionization mode yield simple and predictable mass spectra. Information on interglycosidic linkages and configurations can be deduced from the relative intensities of the selected diagnostic fragments arising from the glycosidic bond cleavages and corroborated by the fragments arising from cross-ring cleavages. As the CID patterns are not dependent on the number of prior tandem mass spectrometric steps, structures can be unambiguously assigned by matching the spectra with a library. The rules governing the fragmentation behavior of this class of oligosaccharides were tested for a representative isomeric disaccharide, Glcbeta1,3Fucalpha-OAllyl. The findings establish a basis for using MS(n) with a quadrupole ion trap instrument to elucidate structures of hexose-fucose subunits from more complicated oligosaccharides. Energy-resolved mass spectra were also acquired by CID tandem triple-quadrupole mass spectrometry. The breakdown behavior of the molecular ions revealed patterns which could differentiate stereoisomers of Gal-Fuc disaccharides over a range of collision energy from 20 to 50 eV.  相似文献   

20.
Fragmentations of three triphenylethylene compounds (toremifene and its two metabolites) with different functional side-chain groups (alcohol, acid and amine) were studied. The compounds were dissociated by collision-induced dissociation (CID) in the interface region of an electrospray ionization source (ESI(+)) and in the collision cell of a triple quadrupole mass spectrometer. Fragmentation pathways for these molecules are proposed, based on accurate mass measurements of in-source fragment ions and MS/MS experiments using product and precursor ion scanning. The side-chain functional groups were found to strongly affect the fragmentations of the molecular ions. The fragmentation pathways of the protonated molecule and sodium ion adduct were quite similar, but the subsequent stabilities of certain common fragments were surprisingly different.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号