首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Engineering near-infrared (NIR) light-sensitive enzymes remains a huge challenge. A photothermal effect-associated method is developed for tailoring the enzymatic activity of enzymes by exposure to NIR light. An ultrasmall platinum nanoparticle was anchored in an enzyme to generate local heating upon NIR irradiation, which enhanced the enzyme activity without increasing bulk temperature. Following NIR irradiation, the enzyme activity was tailored rapidly and reversibly, and was modulated by varying laser power density and irradiation time. Four enzymes were engineered, including glucoamylase, glucose oxidase, catalase, and proteinase K with NIR-light sensitivity, and demonstrated their utility in practical applications such as photolithography and NIR light-responsive antibacterial or anticancer actions. Our investigation suggests that this approach could be broadly used to engineer enzymes with NIR-light sensitivity for many biological applications.  相似文献   

2.
Engineering near‐infrared (NIR) light‐sensitive enzymes remains a huge challenge. A photothermal effect‐associated method is developed for tailoring the enzymatic activity of enzymes by exposure to NIR light. An ultrasmall platinum nanoparticle was anchored in an enzyme to generate local heating upon NIR irradiation, which enhanced the enzyme activity without increasing bulk temperature. Following NIR irradiation, the enzyme activity was tailored rapidly and reversibly, and was modulated by varying laser power density and irradiation time. Four enzymes were engineered, including glucoamylase, glucose oxidase, catalase, and proteinase K with NIR‐light sensitivity, and demonstrated their utility in practical applications such as photolithography and NIR light‐responsive antibacterial or anticancer actions. Our investigation suggests that this approach could be broadly used to engineer enzymes with NIR‐light sensitivity for many biological applications.  相似文献   

3.
An oxygen reducing electrode made of bilirubin oxidase and multi-walled carbon nanotubes (BOD-MWCNT-Au electrode) is coupled to enzymes catalysing oxygen-consuming reactions such as glucose oxidase (GOD) to result in a membrane-free bienzyme electrode. The feasibility of such a molecularly assembled system stabilized by covalent linkage has been demonstrated. The electrochemical characterisation of the bienzyme electrode reveals sensitivity to the enzyme substrate. The results indicate that the BOD-electrode provides a suitable platform for sensing analytes for which oxidases of high activity are available.  相似文献   

4.
This contribution describes new composite carbon paste electrodes (CPEs) for the determination of phenolic compounds. The composite CPEs were prepared by in situ generation of polypyrrole (PPy) within a paste containing the enzyme polyphenol oxidase (PPO). The best paste composition (enzyme/pyrrole monomer/carbon particles/Nujol) was determined for a model enzyme, glucose oxidase (GOx) according to the enzymatic activity of the resulting electrodes and to the enzyme leakage from the paste during storage in phosphate buffer. The in situ electrogenerated PPy improves the enzyme immobilisation within the paste since practically no enzyme was lost in solution after 72 h of immersion. Moreover, the enzyme activity remains particularly stable under storage since the biocomposite structure conserves 80% of its activity after 1 month of storage. Following the optimisation of the paste composition, PPO-based carbon paste biosensors were prepared and presented excellent analytical properties toward catechol detection with a sensitivity of 4.7 A M(-1) cm(-2) and a response time lower than 20 s. The resulting biosensors were applied to the determination of polyphenolic compounds (e.g., epicatechin and ferulic acid).  相似文献   

5.
Various enzymatic reactions or enzymatic cascade reactions occur efficiently in biological microsystems due to space constraints or orderly transfer of intermediate products. Inspired by this, the horseradish peroxidase(HRP)-like nanozyme(Fe-aminoclay) was in situ synthesized on the surface of alkali-activated halloysite nanotubes and the natural enzyme(glucose oxidase, GOx) was immobilized on it to construct a high-efficiency GOx-Fe AC@AHNTs cascade nanoreactor. In which, Fe AC@AHNTs can not on...  相似文献   

6.
G. Göbel  T. Dietz  F. Lisdat 《Electroanalysis》2010,22(14):1581-1585
Based on an oxygen reducing electrode combining bilirubin oxidase and multiwalled carbon nanotubes modified gold (BOD‐MWCNT‐Au electrode) a bienzyme sensor is developed. Therefore the BOD‐MWCNT‐Au electrode is covalently coupled to enzymes catalysing oxygen‐consuming reactions (glucose oxidase and ascorbate oxidase) to result in a membrane‐free bienzyme electrode. The electrochemical characterisation of these bienzyme sensors reveals an enzyme substrate sensitivity down to 250 μM glucose and 100 μM ascorbate. In addition, the assembled sensor systems allow amperometric measurements in a potential range where the influence of interfering substances reacting directly at the transducing electrode is minimised. The results indicate that the BOD electrode provides a suitable platform for sensing analytes of medical and environmental interest for which oxidases of high activity are available.  相似文献   

7.
A new complex consisting of CdTe quantum dots (QDs) and glucose oxidase (GOx) has been facilely assembled to achieve considerably enhanced enzymatic activity and a wide active temperature range of GOx; these characteristics are attributed to the conformational changes of GOx during assembly. The obtained complex can be simultaneously used as a nanosensor for the detection of glucose with high sensitivity. A mechanism is put forward based on the fluorescence quenching of CdTe QDs, which is caused by the hydrogen peroxide (H2O2) that is produced from the GOx-catalyzed oxidation of glucose. When H2O2 gets to the surface of the CdTe QDs, the electron-transfer reaction happens immediately and H2O2 is reduced to O2, which lies in electron hole traps on CdTe QDs and can be used as a good acceptor, thus forming the nonfluorescent CdTe QDs anion. The produced O2 can further participate in the catalyzed reaction of GOx, forming a cyclic electron-transfer mechanism of glucose oxidation, which is favorable for the whole reaction system. The value of the Michaelis-Menton constant of GOx is estimated to be 0.45 mM L(-1), which shows the considerably enhanced enzymatic activity measured by far. In addition, the GOx enzyme conjugated on the CdTe QDs possesses better thermal stability at 20-80 degrees C and keeps the maximum activity in the wide range of 40-50 degrees C. Moreover, the simply assembled complex as a nanosensor can sensitively determine glucose in the wide concentration range from micro- to millimolar with the detection limit of 0.10 microM, which could be used for the direct detection of low levels of glucose in biological systems. Therefore, the established method could provide an approach for the assembly of CdTe QDs with other redox enzymes, to realize enhanced enzymatic activity, and to further the design of novel nanosensors applied in biological systems in the future.  相似文献   

8.
A nanostructured multicatalyst system consisting of Fe(3)O(4) magnetic nanoparticles (MNPs) as peroxidase mimetics and an oxidative enzyme entrapped in large-pore-sized mesoporous silica has been developed for convenient colorimetric detection of biologically important target molecules. The construction of the nanocomposites begins with the incorporation of MNPs on the walls of mesocellular silica pores by impregnating Fe(NO(3))(3)·9H(2)O, followed by the immobilization of oxidative enzymes. Glutaraldehyde crosslinking was employed to prevent enzymes leaching from the pores and led to over 20 wt% loading of the enzyme. The oxidase in the nanocomposite generates H(2)O(2) through its catalytic action for target molecules and subsequently activates MNPs to convert selected substrates into colored products. Using this strategy, two different biosensing systems were constructed employing glucose oxidase and cholesterol oxidase and their analytical capabilities were successfully verified by colorimetrically detecting the corresponding target molecules with excellent selectivity, sensitivity, reusability, and stability. Future potential applications of this technology range from biosensors to multicatalyst reactors.  相似文献   

9.
《Sensors and Actuators》1989,16(3):235-245
A reliable method of physically immobilizing enzymes in cellulose triacetate (TAC) membranes was developed. The method has several advantages compared with analogous ones currently employed; it was possible to prepare enzyme sensors based on immobilized glucose oxidase (GOD) for determination of glucose in standard solutions and control sera, and based on GOD and invertase for determination of sucrose.  相似文献   

10.
吕金枝  张鑫浩 《应用化学》2022,39(5):828-836
环境友好型纳米生物传感器能够提高传统生物分子传感器的检测性能,在实际应用中具有重要的应用价值。本研究以胆碱氧化酶(ChOx)为模板,在室温(25 ℃)下通过矿化作用制备了一种ChOx功能化的室温磷光(RTP)量子点(QDs)(ChOx RTP QDs)纳米生物传感器,并利用ChOx与氯化胆碱的特异性酶-底物反应和光诱导的电子转移(PIET)实现了对氯化胆碱(Cho)的RTP定量检测。该纳米生物传感器对氯化胆碱检测的线性范围为0.05~20 mmol/L,检出限为0.02 mmol/L。该方法基于QDs的RTP性质,可以有效地避免生物样品背景荧光的干扰,且无需复杂的样品前处理过程,因此该方法较适合于生物样品中氯化胆碱的定量检测。  相似文献   

11.
Egg shell membrane is a novel, robust, microporous, cost effective, easily available organic support material. In recent studies egg shell membranes were utilized as organic support for enzyme immobilization. But low conjugation yield limits its application as good support for biotechnological industries. In present study egg shell membrane was chemically treated to introduce free functional groups for covalent linkage of proteins to increase its conjugation yield and stability of conjugate complex. Many enzymes were tested for immobilization on modified egg shell membrane like oxalate oxidase, glucose oxidase, peroxidase and lipase. A fifteen to sixteen fold increase in conjugation yield was observed when immobilization was performed after chemical treatment in comparison to immobilization on native membrane with slight change in specific activity of immobilized enzyme which ranges from 5% to 15%. Egg shell membrane bound enzymes showed slight changes in their kinetic properties after immobilization. Egg shell membrane bound oxalate oxidase shows detection limit of 1.5 μM when used for urinary oxalate determination. Egg shell membrane support shows no interference to enzyme activity and a good correlation of 0.99 was observed with the values estimated using commercially available Sigma kit. The immobilized oxalate oxidase, glucose oxidase, peroxidase and lipase were stable up to duration of 180 days and there is respective loss of 10%, 13%, 24%, and 33% of initial activity. Overall result strengthens our view of using chemically modified egg shell membrane as solid support for better immobilization of enzymes and can be used in various biotechnological applications.  相似文献   

12.
《Analytical letters》2012,45(16):1279-1289
Abstract

The coupling of an enzyme immunoassay for factor VIII-related antigen with a commercial glucose oxidase based amperometric sensor permits the determination of 1.6 to 16 ng of factor XIII-related antigen in human plasma. Further pure amperometric sensors or amperometric enzyme sensors for determination of the main marker-enzymes of enzyme immunoassays are described.  相似文献   

13.
本文以有效提高生物分子包埋率为目的,基于生物/化学同步聚合的新方法制备了一种新型纤维蛋白聚合物基纳米复合物,并研究了该复合物修饰电极的传感性能。该方法在凝血仿生聚合的同时,采用NaAuCl4作为氧化剂化学氧化聚合生成聚多巴胺(PDA),在PDA膜内原位合成纳米金(AuNPs),同时在PDA-纤维蛋白凝胶生长时包埋葡萄糖氧化酶(GOx)。生物/化学同步聚合法操作简单,条件温和。该纳米复合物引入了AuNPs的优异性质,有效提升了GOx的包埋量,所制电化学生物传感器对葡萄糖的检测灵敏度高达117μA/(cm2·mmol/L),检测限为57nmol/L。  相似文献   

14.
《中国化学快报》2021,32(10):3185-3188
In this research, a novel bird nest-like zinc oxide (BN-ZnO) nanostructures were prepared by a simple solvothermal method. A sensitive electrochemical glucose biosensor was for the first time developed based on the immobilization of glucose oxidase (GOx) on nanostructured BN-ZnO modified electrode. The BN-ZnO nanostructure and the resultant biosensor were characterized by scanning electron microscope, X-ray diffraction spectroscopy, Fourier transform infrared spectroscopy, and electrochemical impedance spectroscopy. BN-ZnO nanostructures have large specific surface area and can load large amounts of GOx molecules. Meanwhile, BN-ZnO provides an excellent microenvironment to retain the native bioactivity of enzymes and to promote direct electron transfer between GOx and electrode surface. The proposed biosensor shows a wide linear range of 0.005–1.6 mmol/L, high sensitivity of 15.6 mA L mol−1 cm−2 with a low detection limit of 0.004 mmol/L. The resulting biosensor also shows excellent selectivity, acceptable stability and reproducibility, and can be successfully applied in the detection of glucose in human serum samples at −0.37 V.  相似文献   

15.
A new photoelectrochemical method for the determination of glucose based on the photoelectrochemical effect of poly(thionine) photoelectrode to hydrogen peroxide (H2O2) was reported. The H2O2‐sensitive photoelectrode was fabricated by electropolymerizing thionine on the surface of ITO electrode. And then glucose oxidase was immobilized on the photoelectrode via the aid of chitosan enwrapping, forming an enzyme‐modified photoelectrode. The photoelectrode was employed as an electron acceptor; H2O2 from the catalytic reaction of enzyme was employed as an electron donor, developing an analytical method of glucose without hydrogen peroxidase. In the paper, the photoelectrochemical effects of photoelectrode to H2O2 and glucose were studied. The effects of the bias voltage and the electrolyte pH on the photocurrent were investigated. The linear response of glucose concentrations ranged from 0.05 to 2.00 mmol/L was obtained with a detection limit of 22.0 µmol/L and sensitivity of 73.2 nA/(mmol·L?1). The applied feasibility of method was acknowledged through monitoring the glucose in practical samples.  相似文献   

16.
A sensitive and selective, reasonably fast method for the determination of glucose content has been developed. A glucose oxidase immobilized column was coupled to a small-size anion exchange column/borate buffer chromatograph. The hydrogen peroxide produced in the enzyme reaction was detected directly by an amperometric detector using a platinum working electrode. The detection limit was 0.03 ppm (1.5 x 10(-7) M, 3 pmol/injection). The linear dynamic range was three orders of magnitude at least. The system was stable and reproducible both in short- and long-term operation. The proposed method is suitable for analysis of complicated matrices of biological samples because of its good selectivity and sensitivity.  相似文献   

17.
A quantitative method for the determination of four penicillin antibiotics, amoxicillin (AMO), oxacillin (OXA), cloxacillin (CLO), and dicloxacillin (DICLO), has been developed. Separation was achieved on an Inertsil ODS-3 (250 x 4 mm, 5 microm) column after selective extraction of penicillin drugs from biological matrices by means of SPE. Gradient elution with a mobile phase consisting of 0.1% TFA (pH 1) and ACN, and PDA detection with monitoring at 240 nm was applied. Salicylic acid (5 ng/microL) was used as the internal standard. RP-8 Adsorbex Merck cartridges provided high absolute recoveries (98-101%). The developed method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 8) and between-day precision (n = 8) revealed RSD <10%. Recoveries from biological samples ranged from 91 to 103%. The detection limits were estimated as 3.3 ng for AMO, OXA, and CLO, and 6.6 for DICLO in blood plasma. LOD in whole blood and urine was 6.6 ng. Injection volume was 20 microL. The method was applied to commercially available AMO containing pharmaceuticals and spiked biological matrices. The method was also applied to biological samples after AMO oral administration, where the drug was successfully identified and quantified.  相似文献   

18.
Glucose oxidase and catalase were immobilized via the Ugi reaction by means of cyclohexyl isocyanide and glutaraldehyde on a nylon net partially hydrolysed by hydrochloric acid. A specific enzyme sensor for D-glucose was made by fixing the nylon net with immobilized enzymes on the tip of a Clark-type oxygen sensor. For comparison purposes glucose oxidase and catalase were also co-immobilized in the absence of cyclohexyl isocyanide or only glucose oxidase was immobilized with and without cyclohexyl isocyanide. The prepared biosensors were characterized by the specific activity of glucose oxidase and its dependence on Ph and temperature and by the apparent Michaelis constant. The linear range of the biosensor response to the substrate concentration and the stability of the biosensor were determined. The long-term stabilities of the enzyme electrodes were compared and the advangtage of the developed method was demonstrated.  相似文献   

19.
A novel amperometric glucose biosensor was fabricated by in situ incorporating glucose oxidase (GOD) within the sol‐gel silica film on a Prussian blue (PB) modified electrode. The method is simple and controllable, which combined the merits of in situ immobilizing biomolecules in sol‐gel silica film by electrochemical method and the synergic catalysis effects of PB and GOD molecules. Scanning electron microscopy (SEM) showed that the GOD/sol‐gel silica film was homogeneous with a large number of three‐dimensional nanopores, which not only enhanced mass transport, but also maintained the active configuration of the enzyme molecule and prevented the leakage of enzyme, therefore improved the stability and sensitivity of the biosensor. The fabricated biosensor showed fast response time (10 s), high sensitivity (26.6 mA cm?2 M?1), long‐term stability, good suppression of interference, and linear range of 0.01 mM–5.8 mM with a low detection limit of 0.94 μM for the detection of glucose. In addition, the biosensor was successfully applied to determine glucose in human serum samples.  相似文献   

20.
Aldehyde oxidase is a widely distributed enzyme that is involved in the metabolism of an extensive range of aldehydes and N-heterocyclic compounds with physiological, pharmacological, and toxicological relevance. In the present study, a highly sensitive RP-HPLC-fluorescence method based on the oxidation of phenanthridine to phenanthridinone has been developed and validated to assay aldehyde oxidase activity in biological samples. Determination of phenanthridinone was achieved on a C18 column using 10 mmol/L phosphate buffer (pH 5.0) containing 0.1 mmol/L EDTA-acetonitrile (40 + 60, v/v) as the mobile phase. The fluorescence intensity of phenanthridinone was measured at 364 nm with excitation at 236 nm. The proposed method was precise, accurate, specific and rapid (analysis time, approximately 8 min) with a mean RSD of 2.54%. Peak responses were linear from 0.5 to 100 nmol/L, with an LOD of 0.125 nmol/L. The applicability of the method was demonstrated by measurement of aldehyde oxidase activity in rat liver, kidney, ovary, and heart fractions.  相似文献   