首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The phosphorylation of 5'-deoxy-5-fluorouridine (doxifluridine, 5'-DFUR) has been achieved using inorganic cyclo-triphosphate (P(3m), Na(3)P(3)O(9)) and monoimido-cyclo-triphosphate (MCTP, Na(3)P(3)O(8)NH) in aqueous solution. In the reaction of 5'-DFUR with P(3m), 2'-monophospho-5'-DFUR and 3'-monophospho-5'-DFUR were synthesized with a total yield of more than 95%. In the reaction of 5'-DFUR with MCTP, 2'-diphosphoramidophosphono-5'-DFUR and 3'-diphosphoramidophosphono-5'-DFUR were synthesized with a total yield of more than 40%. The phosphorylated products with P(3m) and MCTP were stable in neutral and alkaline solutions.  相似文献   

2.
A specific high-performance liquid chromatography method has been developed for simultaneous detection of vinclozolin and its degradation products (M1, M2, and M3). The method has been validated according to ICH guidelines and can be extended to quantitation of vinclozolin. A base-line separation of vinclozolin and its degradation products was found with symmetrical peak shapes on an XTerra MS C18 column using 10 mM ammonium bicarbonate at pH 9.2 and acetonitrile as mobile phase. The retention times of vinclozolin, M1, M2, and M3 were 12.8, 8.1, 11.6, and 11.1 min, respectively. A linear calibration curve was obtained across a range from 5 to 200 microM for vinclozolin. The intra- and inter-day relative standard deviations (%RSD) were <1%. Greater than 90% recoveries of vinclozolin from bio-fluids including mouse plasma, serum and urine, and rabbit bile, were obtained in a single step with a single solvent.  相似文献   

3.
A rapid and selective liquid chromatography/tandem mass spectrometric method was developed for the simultaneous determination of capecitabine and its metabolites 5′‐deoxy‐5‐fluorocytidine (5′‐DFCR), 5′‐deoxy‐5‐fluorouracil (5′‐DFUR), 5‐fluorouracil (5‐FU) and dihydro‐5‐fluorouracil (FUH2) in human plasma. A 200 μL human plasma aliquot was spiked with a mixture of internal standards fludarabine and 5‐chlorouracil. A single‐step protein precipitation method was employed using 10% (v/v) trichloroacetic acid in water to separate analytes from bio‐matrices. Volumes of 20 μL of the supernatant were directly injected onto the HPLC system. Separation was achieved on a 30 × 2.1 mm Hypercarb (porous graphitic carbon) column using a gradient by mixing 10 mm ammonium acetate and acetonitrile–2‐propanol–tetrahydrofuran (1 : 3 : 2.25, v/v/v). The detection was performed using a Finnigan TSQ Quantum Ultra equipped with the electrospray ion source operated in positive and negative mode. The assay quantifies a range from 10 to 1000 ng/mL for capecitabine, from 10 to 5000 ng/mL for 5′‐DFCR and 5′‐DFUR, and from 50 to 5000 ng/mL for 5‐FU and FUH2 using a plasma sample of 200 μL. Correlation coefficients (r2) of the calibration curves in human plasma were better than 0.99 for all compounds. At all concentration levels, deviations of measured concentrations from nominal concentration were between ?4.41 and 3.65% with CV values less than 12.0% for capecitabine, between ?7.00 and 6.59% with CV values less than 13.0 for 5′‐DFUR, between ?3.25 and 4.11% with CV values less than 9.34% for 5′‐DFCR, between ?5.54 and 5.91% with CV values less than 9.69% for 5‐FU and between ?4.26 and 6.86% with CV values less than 14.9% for FUH2. The described method was successfully applied for the evaluation of the pharmacokinetic profile of capecitabine and its metabolites in plasma of treated cancer patients. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
A liquid chromatographic/tandem mass spectrometric method was developed and validated for the quantitation of capecitabine and its metabolite 5-fluorouracil in human plasma. The simultaneous determination of both analytes was achieved by a column switching method using a trapping column and two analytical columns with different stationary phases. Isocratic elution was used for the separation of capecitabine on a C18 column whereas 5-fluorouracil was separated using gradient elution on an non-polar carbon phase. The calibration curves were linear for both compounds with a correlation factor (R2) > 0.9993 for 5-fluorouracil and >0.9942 for capecitabine. The assay was validated in the concentration range 5.00-1000 ng ml(-1) for both compounds. The intra-day precision was better than 10% for 5-fluorouracil and better than 11% for capecitabine whereas the inter-day precision was better than 8% for 5-fluorouracil and better than 14% for capecitabine.  相似文献   

5.
A robust new analytical method has been developed for the determination of 5-fluorouracil (5-FU) in human plasma samples using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The method is based on a liquid-liquid extraction procedure, precolumn derivatization, reversed-phase HPLC separation, and detection using atmospheric pressure chemical ionization and selected reaction monitoring. The derivatization agent used was 4-bromomethyl-7-methoxycoumarin. The internal standard for the assay procedure was a stable isotope labeled analog of 5-FU. The lower limit of quantitation was 1. 0 ng/mL using 500 µ L aliquots of plasma. Sample throughput on the mass spectrometer was approximately 17 samples/h (3. 5 min/sample). The method was fully validated. The recovery of 5-FU averaged 76. 1%. The accuracy of the assay, assessed from quality control samples, ranged from 99. 1% to 104. 3% (% theoretical). The overall interassay precision (% RSD) was 2. 7%, and the intraassay precision (% RSD) ranged from 1.5% to 3. 9%. The derivatized samples were found to be stable under sample analysis conditions and during refrigerator storage. The method was specific for the determination of 5-FU.  相似文献   

6.
A method was developed for the quantitative analysis of the novel anticancer agent ES-285 (spisulosine; free base) in human, mouse, rat, and dog plasma using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry in order to support pre-clinical and clinical studies with the drug. Sample preparation was carried out by protein precipitation with acetonitrile, containing isotopically labeled (d(3)) ES-285 as internal standard. Aliquots of 10 micro l of the supernatant were injected directly on to an Inertsil ODS-3 column (50 x 2.0 mm i.d., 5 micro m). Elution was carried out using methanol-10 mM ammonium formate (pH 4) in water (80 : 20, v/v) pumped at a flow-rate of 0.2 ml min(-1) with a run time of 8 min. Multiple reaction monitoring chromatograms obtained on an API365 triple-quadrupole mass spectrometer were used for quantification. The lower limit of quantitation (LLOQ) was 10 ng ml(-1) in human, mouse, rat, and dog plasma and the linear dynamic range extended to 500 ng ml(-1). A full validation of the method was performed in human plasma, and partial validations were performed in mouse, rat and dog plasma. Accuracies and precisions were <20% at the LLOQ concentration and <15% for all other concentrations in all matrices. ES-285 was stable during all steps of the assay. Thus far this method has been used successfully to analyze over 500 samples in pre-clinical trials, and will be implemented in the planned clinical phase I studies.  相似文献   

7.
A relatively simple, sensitive and rapid high-performance liquid chromatographic method is described for measuring the anticancer drug 5-fluorouracil (5-FU) in human plasma and urine. The procedure includes liquid-liquid extraction using ethyl acetate-methanol (95:5) and preparative column chromatography to separate 5-FU from constituents normally occurring in these biological samples. The columns contained a specially modified form of diatomaceous earth, which requires no pre-conditioning washes. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70 mm x 4.6 mm I.D.) with a mobile phase of water-methanol (95:5) and ultraviolet detection (268 nm). The overall recovery from plasma and urine was 91 and 94%, respectively, at the concentration of 50 ng/ml. The determination limit of the assay for 5-FU was 10 ng/ml of plasma and urine. Concentrations of 5-FU between 10 and 500 ng/ml were measured in plasma and urine with a relative standard deviation of 6.8%. In order to evaluate the procedure, plasma and urine samples from three patients treated with 5-FU by continuous intravenous perfusion, were investigated.  相似文献   

8.
The new monomer, α-ethoxy-exo-3,6-epoxy-1,2,3,6-tetrahydrophthaloyl-5-fluorouracil (EETFU), was synthesized from 5-fluorouracil (5-FU) and α-ethoxy-exo-3,6-epoxy-1,2,3,6-tetrahydrophthaloyl chloride. Its homopolymer and copolymers with acrylic acid (AA) and vinyl acetate (VAc) were synthesized by photopolymerizations using 2,2-dimethoxy-2-phenylaceto-phenone. The synthesized samples were characterized by FT-IR, 1H-NMR and 13C-NMR spectroscopes, elemental analysis, and gel permeation chromatography. The EETFU contents in poly(EETFU-co-AA) and poly(EETFU-co-VAc) were 40 and 37 mol %, respectively. The number average molecular weights were in range from 8,400 to 10,300. The in vitro cytotoxicities of synthesized samples were evaluated against mouse mammary carcinoma (FM3A), mouse leukemia (P388), and human histiocytic lymphoma (U937) as cancer cell lines and mouse liver cells (AC2F) as a normal cell line. The range of IC50 values obtained from the in vitro test for synthesized samples were 0.03–0.16 µg/mL against cancer cell lines. The in vitro cytotoxicities of polymers were beter than 5-FU. The in vivo antitumor activities of synthesized monomer and polymers were also investigated by mice bearing the sarcoma 180 tumor cells. The in vivo antitumor activities of the synthesized monomer and polymers were greater than those of 5-FU at corresponding dosage concentrations. © 1999 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 37: 2619–2627, 1999  相似文献   

9.
A validated, sensitive and precise reversed-phase high-performance liquid chromatographic method for the simultaneous determination of 5-flucytosine (5-FC) and 5-fluorouracil (5-FU) in human plasma is described. Two compounds, 5-methylcytosine (5-MC) and 5-chlorouracil (5-CU), were used as internal standards for the determination of 5-FC and 5-FU, respectively. Plasma samples were deproteinized with trichloroacetic acid and chromatographed on an octylsilica column, maintained at 30 degrees C during elution, using a 0.04 M phosphate buffer, pH 7.0, as eleunt. Spectrophotometric diode array detection was used at 266 nm. 5-FC, 5-FU, 5-MC and 5-CU were found to have retention times of 4.8, 5.8, 7.7 and 11.0 min respectively. Recoveries of 91-120% with reproducibility and repeatability coefficients of variation of 0.8-6% were obtained. Mean correlation coefficients of 0.99989 and 0.9995 were found for the linear calibration curves (n = 2) of 5-FC (4.816-192.6 mg/l) and 5-FU (0.05368-5.368 mg/l), respectively. The limits of quantitation were 0.3 mg/l for 5-FC and 0.05 mg/l for 5-FU.  相似文献   

10.
A highly sensitive and convenient gas chromatographic-mass spectrometric (GC-MS) method is described for the determination of 5-fluorouracil in the presence of 2'-deoxy-5-fluorouridine (which breaks down into 5-fluorouracil during ordinary GC derivatization) in biological samples such as plasma and urine. After extraction with ethyl acetate, 5-fluorouracil and 5-chlorouracil, the latter being used as an internal standard, were converted into their tert.-butyldimethylsilyl derivatives by allowing the mixture to stand for 30 min at room temperature and were assayed by electron-impact ionization GC-MS. Under these conditions, 2'-deoxy-5-fluorouridine did not decompose or interfere with the determination of 5-fluorouracil. The assay method, including the extraction and tert.-butyldimethylsilyl derivatization of 5-fluorouracil, showed good linearity in the range 0-100 ng/ml for 5-fluorouracil in plasma (detection limit 0.5 ng/ml) and urine (detection limit 1 ng/ml). The usefulness of this method was demonstrated by determining plasma concentrations of 5-fluorouracil in rats treated intravenously with 5-fluorouracil and 2'-deoxy-5-fluorouridine.  相似文献   

11.
A foodborne illness caused by type A toxin-producing Clostridium botulinum was investigated by using the standard mouse bioassay and a rapid invitro test for toxin detection. The patient, who consumed improperly stored hash brown potatoes that contained the preformed toxin, was diagnosed with type A botulism. C. botulinum type A toxin was detected in the hash brown potatoes as well as in the tryptone-peptone-glucose-yeast extract (TPGY) medium subcultures of this food using the mouse bioassay and an amplified ELISA technique. The mouse bioassay revealed preformed toxin at 10,000 minimum lethal dose (MLD)/g uncooked product and the amplified ELISA an equivalent 50,000 MLD/g. The cultural toxin from the uncooked product killed mice at the 10(6) dilution and a modification of the ELISA procedure was positive at the 10(3) dilution. Cooked food obtained from the consumer's waste can contained 100 MLD/g and the ELISA was also positive at the same dilution of the product. The culture of the cooked product obtained from the waste can was lethal for mice at the 10(7) dilution and positive using the modified ELISA at the 10(4) dilution. The unmodified amplified ELISA method indicated a toxin level of approximately 1 ng/mL (equivalent to 5 x 10(5) MLD/mL) in diluted culture fluid from the uncooked food and the culture of cooked food obtained from the waste can. The hash brown potatoes were negative for types B, E, and F preformed and cultural botulinal toxins using both assays.  相似文献   

12.
Determination of 5-fluorouracil in hospital effluents   总被引:1,自引:0,他引:1  
Cytostatic anticancer drugs are an increasingly important issue in the environmental debate, mainly due to the lack of knowledge about the fate of these toxic substances. Over the last decades, 5-fluorouracil (5-FU) has been one of the most frequently used antineoplastic agents and may, therefore, be regarded as one of the pilot substances for environmental contamination. As a prerequisite for these investigations, a method for the determination of 5-FU in hospital effluents has been developed. Waste water samples were enriched by solid-phase extraction on ENV+ columns (concentration factor 500) and analysed by capillary electrophoresis using a buffer containing 80% 160 mM sodium borate buffer (pH 9.5) and 20% acetonitrile (v/v). This method is applicable within the range 5–500 g 5-FU L–1. The standard curve (correlation coefficient >0.99) was linear with recovery rates from 80 to 96% and an accuracy from 9.0 to 20% (intra-assay standard deviation 0.7–8.9%; inter-assay standard deviation 2.2–9.5%). Based on the consumption of 5-FU in oncologic departments and the detection limit of 1.7 g L–1, this method covers the range necessary to evaluate 5-FU in hospital effluents. The applicability of the method was proven by chemical analysis of real hospital waste water samples. Obtained over a time period of 1 month (range 20–122 g 5-FU L–1), the results were similar to those calculated by an input–output model. The presented method provides an analytical tool necessary to face the monitoring of environmental contamination problems.Abbreviations 5-FU 5-Fluorouracil - OECD Organization for economic cooperation and development  相似文献   

13.
This investigation examined chemical and microbiological transformations of an arsenosugar by mouse cecum. To mimic the low oxygen environment in the mammalian gastrointestinal tract, reaction mixtures were incubated under anaerobic conditions. An arsenosugar extracted from ribbon kelp, 3-[5'-deoxy-5-(dimethylarsinoyl)-beta-ribofuranosyloxy]-2-hydroxypropanesulfonic acid, As392, was added to reaction mixtures that contained either cecal microflora or cecal tissue homogenate. These reaction mixtures were incubated at 0 or 37 degrees C for up to 48 hours to monitor biotransformation of the arsenosugar. Analysis of the reaction mixtures by IC-ICP-MS and LC-ESI-MS/MS indicated that the arsenosugar was converted primarily (95%) to its sulfur analog in less than 1 h at 37 degrees C. Conversion of As392 to its sulfur analog was much slower at 0 degrees C (21% conversion after 48 h). In reaction mixtures with cecal tissue homogenate, conversion of As392 to its sulfur analog was slower (77% conversion after 48 h at 37 degrees C). A good mass balance was found in all reaction mixtures between the amount of arsenosugar added and the sum of all detected arsenic-containing products. LC-ESI-MS/MS spectra of the sulfur-containing arsenosugar formed in all reaction mixtures containing cecal microflora compared well with those of a synthetic standard. These results suggest that the anaerobic microflora of the gastrointestinal tract can rapidly convert ingested arsenosugars to sulfur analogs. This biotransformation may affect the subsequent absorption, metabolism, and disposition of arsenic present in arsenosugars.  相似文献   

14.
A practical synthesis of 3'-O-benzyl-2'-deoxy-5-trifluoromethyluridine (1), a candidate antitumor agent for clinical testing, was developed from 2'-deoxy-5-iodouridine (3). Benzylation of 2'-deoxy-5-iodo-5'-O-trityluridine (14) with benzyl bromide and sodium hydride in tetrahydrofuran gave the 3'-O-derivative (16). Benzoylation of 16 afforded the N3-benzoyl derivative (17). Coupling of 17 with trifluoromethylcopper, prepared from bromotrifluoromethane and copper powder in the presence of 4-dimethylaminopyridine, gave the 5-trifluoromethyl derivative (19) minimally contaminated with the 5-pentafluoroethyl compound. Deprotection of 19 furnished 1.  相似文献   

15.
A simple and rapid high-performance liquid chromatographic (HPLC) method with ultraviolet detection has been developed and validated for the simultaneous determination of rifampicin and sulbactam in mouse plasma. Plasma samples were deproteinized with acetonitrile and separated by HPLC on a RP-18 (125 x 4 mm, 5 microm) column and gradient elution with potassium dihydrogen phosphate solution (pH 4.5; 50 mm) and acetonitrile at a flow-rate of 1.0 mL/min. Rifampicin and sulbactam were monitored at 230 nm and confirmed by means of their UV spectra using a diode-array detector. The method was linear at plasma levels from 1 to 100 microg/mL for rifampicin and from 5 to 200 microg/mL for sulbactam. The limits of quantification were 0.6 microg/mL for rifampicin and 4.2 microg/mL for sulbactam. The intra- and inter-day precisions of the method (RSD) were lower than 5% for both compounds. Average recoveries of rifampicin and sulbactam from mice plasma were 98.2 and 89.3%, respectively. The developed method was successfully applied to the determination of the pharmacokinetic profile of both compounds in mice.  相似文献   

16.
The aim of the present study was to develop a simple, sensitive and accurate liquid chromatography–electrospray ionization tandem mass spectrometry (ESI‐MS/MS) method for the determination of lixivaptan (LIX) in mouse plasma using vildagliptin as the internal standard (IS). A precipitation procedure was used for the extraction of LIX and vildagliptin from mouse plasma. Chromatographic separation of LIX was achieved using a C18 analytical column (50 × 2.1 mm, 1.8 μm) at 25°C. The mobile phase comprised acetonitrile and ammonium formate (10 mm , pH 3.1; 40:60, v /v) pumped at a flow rate of 0.3 mL min−1. A tandem mass spectrometer with an electrospray ionization source was used to perform the assay. Quantification of LIX at m/z 290 → 137 and IS at 154 → 97 was attained through multiple reaction monitoring. The investigated method was authenticated following the bio‐analytical method of validation guidelines of the US Food and Drug Administration. The developed method showed a good linearity over the concentration range from 5 to 500 ng mL−1, and the calibration curve was linear (r = 0.9998). The mean recovery of LIX from mouse plasma was 99.2 ± 0.68%. All validation parameters for LIX were within the levels required for acceptance. The proposed method was effectively used for a pharmacokinetic study of LIX in mouse plasma.  相似文献   

17.
We have investigated the response of normal and cancer cells to exposure a combination of celecoxib (Celbx) and 5-fluorouracil (5-FU) using a lab-on-a-chip microfluidic device. Specifically, we have tested the cytotoxic effect of Celbx on normal mouse embryo cells (Balb/c 3T3) and human lung carcinoma cells (A549). The single drugs or their combinations were adjusted to five different concentrations using a concentration gradient generator (CGG) in a single step. The results suggest that Celbx can enhanced the anticancer activity of 5-FU by stronger inhibition of cancer cell growth. We also show that the A549 cancer cells are more sensitive to Celbx than the Balb/c 3T3 normal cells. The results obtained with the microfluidic system were compared to those obtained with a macroscale in vitro cell culture method. In our opinion, the microfluidic system represents a unique approach for an evaluation of cellular response to multidrug exposure that also is more simple than respective microwell plate assays.
Figure
?  相似文献   

18.
The ability of surface-enhanced Raman spectroscopy (SERS) to measure 5-fluorouracil (5-FU) in saliva is presented. The approach is based on the capacity of Raman spectroscopy to provide a unique spectral signature for virtually every chemical, and the ability of SERS to provide microg/mL sensitivity. A simple sampling method, that employed 1-mm glass capillaries filled with silver-doped sol-gels, was developed to isolate 5-FU from potential interfering chemical components of saliva and simultaneously provide SERSactivity. The method involved treating a 1 mL saliva sample with 1 mL of acetic acid, drawing 10 microL of sample into a SERS-active capillary by syringe, and then measuring the SER spectrum. Quality SER spectra were obtained for samples containing as little as 2 microg of 5-FU in 1 mL saliva. The entire process, the acid pretreatment, extraction and spectral measurement, took less than 5 minutes. The SERS of 5-fluorouridine and 5-fluoro-2'-deoxyuridine, two major metabolites of 5-FU, were also measured and shown to have unique spectral peaks. These measurements suggest that disposable SERS-active capillaries could be used to measure 5-FU and metabolite concentrations in chemotherapy patient saliva, thereby providing metabolic data that would allow regulating dosage. Tentative vibrational mode assignments for 5-FU and its metabolites are also given.  相似文献   

19.
The development and validation of an assay for the determination of paclitaxel in human plasma, human brain tumor tissue, mouse plasma and mouse brain tumor tissue is described. Paclitaxel was extracted from the matrices using liquid-liquid extraction with tert-butyl methyl ether, followed by chromatographic analysis using an alkaline eluent. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicate that calibration standards in human plasma can be used to quantify paclitaxel in all tested matrices. In human samples, the validated range for paclitaxel was from 0.25-1000 ng ml(-1) using 200 microl plasma aliquots and from 5 to 5000 ng g(-1) using 50 microl tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma). In mice, the ranges were 1-1000 ng ml(-1) and 5-5000 ng g(-1) using 50 microl of mouse plasma and 50 microl of tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma), respectively. The method can be applied to studies generating only small sample volumes (e.g. mouse plasma and tumor tissue), but also to studies in human plasma requiring a lower limit of quantitation. The assay was applied successfully to several studies with both human and mouse samples.  相似文献   

20.
The new monomer, α-methoxy-3,6-endo-methylene-1,2,3,6-tetrahydrophthaloyl-5-fluorouracil (MMTFU), was synthesized from 5-fluorouracil (5-FU) and α-methoxy-3,6-endo-methylene-1,2,3,6-tetrahydrophthaloyl chloride (MMTC). Poly(α-methoxy-3,6-endo-methylene-1,2,3,6-tetrahydrophthaloyl-5-fluorouracil) [poly(MMTFU)], poly(α-methoxy-3,6-endo-methylene-1,2,3,6-tetrahydrophthaloyl-5-fluorouracil-co-acrylicco-AA), and poly(α-methoxy-3,6-endo-methylene-1,2,3,6-tetrahydrophthaloyl-5-fluorouracil-co-vinyl acetate) [poly(MMTFU-co-VAc)] were synthesized by photopolymerizations using 2,2-dimethoxy-2-phenylacetophenone (DMP) as the photoinitiator. The synthesized MMTFU and the polymers were identified by FT-IR, 1H-NMR, and 13C-NMR spectroscopies. The contents of MMTFU in poly(MMTFU-co-AA) and poly(MMTFU-co-VAc) determined by elemental analysis were 63 and 57 mol %, respectively. The number average molecular weights and polydispersity indices of synthesized polymers determined with GPC were in range of 7,700–19,100 and 1.6–2.7. The in vitro cytotoxicities of samples were evaluated with mouse mammary carcinoma (FM3A), mouse leukemia (P388), and human histiocytic lymphoma (U937) as cancer cell lines and mouse liver cells (AC2F) as a normal cell line. The cytotoxicities of 5-FU and synthesized samples against cancer cell lines increased in following orders: 5-FU > MMTFU > poly(MMTFU) > poly(MMTFU-co-AA) > poly(MMTFU-co-VAc). The in vivo antitumor activities of the synthesized samples against mice bearing the sarcoma 180 tumor cell line were evaluated. The in vivo antitumor activities of the polymers were greater than that of 5-FU at a dose of 80 mg/kg. © 1998 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 36: 1625–1632, 1998  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号