 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel approach to the analysis of ecstasy tablets by direct mass spectrometry coupled with thermal desorption (TD) and counter‐flow introduction atmospheric pressure chemical ionization (CFI‐APCI) is described. Analytes were thermally desorbed with a metal block heater and introduced to a CFI‐APCI source with ambient air by a diaphragm pump. Water in the air was sufficient to act as the reactive reagent responsible for the generation of ions in the positive corona discharge. TD‐CFI‐APCI required neither a nebulizing gas nor solvent flow and the accompanying laborious optimizations. Ions generated were sent in the direction opposite to the air flow by an electric field and introduced into an ion trap mass spectrometer. The major ions corresponding to the protonated molecules ([M + H]+) were observed with several fragment ions in full scan mass spectrometry (MS) mode. Collision‐induced dissociation of protonated molecules gave characteristic product‐ion mass spectra and provided identification of the analytes within 5 s. The method required neither sample pretreatment nor a chromatographic separation step. The effectiveness of the combination of TD and CFI‐APCI was demonstrated by application to the direct mass spectrometric analysis of ecstasy tablets and legal pharmaceutical products. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
In multi-analyte procedures, sufficient separation is important to avoid interferences, particularly when using liquid chromatography/mass spectrometry (LC/MS) because of possible ion suppression or enhancement. However, even using ultra-high-performance LC, baseline separation is not always possible. For development and validation of an LC/MS/MS approach for quantification of 140 antidepressants, benzodiazepines, neuroleptics, beta-blockers, oral antidiabetics, and analytes measured in the context of brain death diagnosis in plasma, the extent of ion suppression or enhancement of co-eluting analytes within and between the drug classes was investigated using atmospheric-pressure chemical ionization (APCI) or electrospray ionization (ESI). Within the drug classes, five analytes showed ion enhancement of over 25% and six analytes ion suppression of over 25% using APCI and 16 analytes ion suppression of over 25% using ESI. Between the drug classes, two analytes showed ion suppression of over 25% using APCI. Using ESI, one analyte showed ion enhancement of over 25% and five analytes ion suppression of over 25%. These effects may influence the drug quantification using calibrators made in presence of overlapping and thus interfering analytes. Ion suppression/enhancement effects induced by co-eluting drugs of different classes present in the patient sample may also lead to false measurements using class-specific calibrators made in absence of overlapping and thus interfering analytes. In conclusion, ion suppression and enhancement tests are essential during method development and validation in LC/MS/MS multi-analyte procedures, with special regards to co-eluting analytes.  相似文献   

3.
Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) and electrospray ionization (ESI)-MS can cover the analysis of analytes from low to high polarities. Thus, an ion source that possesses these two ionization functions is useful. Atmospheric surface-assisted ionization (ASAI), which can be used to ionize polar and nonpolar analytes in vapor, liquid, and solid forms, was demonstrated in this study. The ionization of analytes through APCI or ESI was induced from the surface of a metal substrate such as a titanium slab. ASAI is a contactless approach operated at atmospheric pressure. No electric contacts nor any voltages were required to be applied on the metal substrate during ionization. When placing samples with high vapor pressure in condensed phase underneath a titanium slab close to the inlet of the mass spectrometer, analytes can be readily ionized and detected by the mass spectrometer. Furthermore, a sample droplet (~2 μL) containing high-polarity analytes, including polar organics and biomolecules, was ionized using the titanium slab. One titanium slab is sufficient to induce the ionization of analytes occurring in front of a mass spectrometer applied with a high voltage. Moreover, this ionization method can be used to detect high volatile or polar analytes through APCI-like or ESI-like processes, respectively.  相似文献   

4.
In the HPLC of basic drugs and metabolites, good efficiency and peak shape can often be attained using strong cation‐exchange packings with isocratic 100% methanol eluents containing an ionic modifier at an appropriate pH* and ionic strength. Solvent extracts can be analysed directly, and use of ammonium acetate as modifier facilitates the use of atmospheric pressure chemical ionization (APCI)–tandem mass spectrometry, selected reaction monitoring mode. For the analysis of amisulpride and of metamfetamine/amfetamine in plasma (200 µL) after single oral doses in man, a column packed with Waters Spherisorb S5SCX (5 µm average particle size, 100 × 2.1 mm i.d.) was used with methanolic ammonium acetate (40 mmol/L, pH* 6.0, flow rate 0.5 mL/min) as eluent (35°C). Deuterated internal standards were used for each analyte. Detection was by positive‐mode APCI. Responses for all analytes were linear over the calibration ranges. Intra‐assay precision (RSD) was 2–18%, and inter‐assay precision was 2–12%. The limit of detection was 0.5 µg/L for all analytes. No significant matrix effects or isobaric interferences were noted. The total analysis time was 7 min. Similar methodology can be applied to a wide range of basic analytes using MS/MS detection. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
The atmospheric pressure chemical ionization/time,of-flight mass speetrmtry (APEI/TOF-MS) was applied to determine the mass of five a.aIIenic alcohols via their vrotonated molecu.lar ions nslna Imsifive ion mode. Polyethylene Idycol (PEG) was used as the hlternal reference. All results were obtained under the resolution of about 5000 FWHM (full width at the half maximum). Solvent effects were studied and the satired results were obtained in acetonitrile. Comvared with the theoreflcal values, nun absolute errors were less thRn 1.0 mmu. The efTeets Of nozzle pote.Jldal, push pulse potential, pug pulse potentlai, puO bias potential and ic(lulsltion rate on exact mass determina/lon were also discussed. APCI/TOF.MS is proven to be a very semi/ire analytical technique and an alternative ionizafion mode in analytical technique lablle compounds with relatively weak polarity, such as a-allenic alcohol.  相似文献   

6.
Atmospheric pressure photoionization (APPI) is a novel method of ionization in liquid chromatography/mass spectrometry (LC/MS). It was originally developed in order to broaden the range of LC/MS ionizable compounds towards less polar compounds that cannot be analyzed by electrospray (ESI) and atmospheric pressure chemical ionization (APCI). Studies done thus far have shown that non-polar compounds that earlier were not ionizable in LC/MS can indeed be ionized by the use of APPI. However, the best ionization efficiency for low polarity samples has been achieved with low proton affinity (PA) solvents that are not suitable in reversed-phase LC (RP-LC). Here it is demonstrated that the signals for analytes with low proton affinities in acetonitrile can be increased 100-fold by using anisole as the dopant for APPI, which takes the sensitivity to the same level achieved in the analysis of high PA analytes.  相似文献   

7.
We report the development and tests of several systems for the simultaneous determination of 18 energetic compounds and related congeners in untreated water samples. In these systems a Restricted Access Material trap or liquid-chromatography precolumn (with a C(18) or porous graphitic carbon, PGC, stationary phase) followed by a PGC analytical column are used for sample clean-up, enrichment and separation of the trace level analytes, which are then analyzed by mass spectrometry (MS). The relative merits of two MS ionization interfaces (atmospheric pressure chemical ionization, APCI, and atmospheric pressure photoionization, APPI) were also compared for the MS identification and quantification of these analytes. APCI was found to be superior in cases where both alternatives are applicable. A major drawback when applying APPI is that no signal is obtained for the cyclic nitramines and nitrate esters. Using APCI, a wide spectrum of unstable compounds can be determined in a single analysis, and the feasibility of using large volume samples (up to 100 mL) in combination with the sensitivity of the MS detection system provide method detection limits ranging from 2.5 pg/mL (for 2,4-dinitrotoluene and 2,6-diamino-6-nitrotoluene) to 563 pg/mL (for pentaerythritol tetranitrate, PETN), with repeatability ranging from 2 to 7%. Other chemometric parameters such as robustness, selectivity, repeatability, and intermediate precision were also evaluated in the validation of the extraction methods for use in water analysis. Tests with untreated groundwater and drinking water samples, spiked with 20 ng of the analytes, yielded results similar to those obtained with high purity water samples.  相似文献   

8.
This work demonstrated a simple platform for rapid and effective surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF MS) measurements based on the layer structure of reduced graphene oxide (rGO) and gold nanoparticles. A multi-layer thin film was fabricated by alternate layer-by-layer depositions of rGO and gold nanoparticles (LBL rGO/AuNP). The flat and clean two-dimensional film was served as the sample plate and also functioned as the matrix in SALDI-TOF MS. By simply one-step deposition of analytes onto the LBL rGO/AuNP sample plate, the MS measurements of various homogeneous samples were ready to execute. The optimization of MS signal was reached by the variation of the layer numbers of rGO and gold nanoparticles. Also, the small molecules including amino acids, carbohydrates and peptides were successfully analyzed in SALDI-TOF MS using the LBL rGO/AuNP sample plate. The results showed that the signal intensity, S N−1 ratio and reproducibility of SALDI-TOF spectra have been significantly improved in comparison to the uses of gold nanoparticles or α-cyano-4-hydroxy-cinnamic acid (CHCA) as the assisted matrixes. Taking the advantages of the unique properties of rGO and gold nanoparticles, the ready-to-use MS sample plate, which could absorb and dissipate laser energy to analytes quite efficiently and homogeneously, has shown great commercial potentials for MS applications.  相似文献   

9.
The use of mass spectrometry (MS) to acquire molecular images of biological tissues and other substrates has developed into an indispensable analytical tool over the past 25 years. Imaging mass spectrometry technologies are widely used today to study the in situ spatial distributions for a variety of analytes. Early MS images were acquired using secondary ion mass spectrometry and matrix-assisted laser desorption/ionization. Researchers have also designed and developed other ionization techniques in recent years to probe surfaces and generate MS images, including desorption electrospray ionization (DESI), nanoDESI, laser ablation electrospray ionization, and infrared matrix-assisted laser desorption electrospray ionization. Investigators now have a plethora of ionization techniques to select from when performing imaging mass spectrometry experiments. This brief perspective will highlight the utility and relative figures of merit of these techniques within the context of their use in imaging mass spectrometry.  相似文献   

10.
The employment of chemical weapons by rogue states and/or terrorist organizations is an ongoing concern in the United States. The quantitative analysis of nerve agents must be rapid and reliable for use in the private and public sectors. Current methods describe a tedious and time‐consuming derivatization for gas chromatography–mass spectrometry and liquid chromatography in tandem with mass spectrometry. Two solid‐phase extraction (SPE) techniques for the analysis of glyphosate and methylphosphonic acid are described with the utilization of isotopically enriched analytes for quantitation via atmospheric pressure chemical ionization–quadrupole time‐of‐flight mass spectrometry (APCI‐Q‐TOF‐MS) that does not require derivatization. Solid‐phase extraction‐isotope dilution mass spectrometry (SPE‐IDMS) involves pre‐equilibration of a naturally occurring sample with an isotopically enriched standard. The second extraction method, i‐Spike, involves loading an isotopically enriched standard onto the SPE column before the naturally occurring sample. The sample and the spike are then co‐eluted from the column enabling precise and accurate quantitation via IDMS. The SPE methods in conjunction with IDMS eliminate concerns of incomplete elution, matrix and sorbent effects, and MS drift. For accurate quantitation with IDMS, the isotopic contribution of all atoms in the target molecule must be statistically taken into account. This paper describes two newly developed sample preparation techniques for the analysis of nerve agent surrogates in drinking water as well as statistical probability analysis for proper molecular IDMS. The methods described in this paper demonstrate accurate molecular IDMS using APCI‐Q‐TOF‐MS with limits of quantitation as low as 0.400 mg/kg for glyphosate and 0.031 mg/kg for methylphosphonic acid. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
The capabilities of atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) methods for quantitative analysis of polar and ionic compounds in petroleum fractions have been examined. The requirements of the analysis for sensitivity, linear dynamic range, and structural characterization have been discussed. ESI was found to be approximately two orders of magnitude more sensitive than APCI and is most suitable for the detection of analytes in weak concentrations. Equivalent relative linear dynamic ranges were observed by the two methods (at least three orders of magnitude). For the relatively high analyte concentrations examined here (e.g., 1-100 ppm or higher), the absolute area counts increased linearly with the analyte amount only in APCI, making this method more attractive for quantitative liquid chromatography/mass spectrometry (LC/MS) applications. Nevertheless, a wider range of ionic compounds can be detected by ESI than by APCI.  相似文献   

12.
Chen X  Kong L  Su X  Pan C  Ye M  Zou H 《Journal of chromatography. A》2005,1089(1-2):87-100
An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P. corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with detection of UV absorbance and atmospheric pressure chemical ionization mass spectrometer (APCI/MS), respectively, and also analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) with matrix of oxidized carbon nanotubes. Totally more than 188 components in P. corylifolia extract were detected with this integrated approach, and 12 of them were preliminary identified according to their UV spectra and mass spectra performed by APCI/MS and MALDI-TOF/MS. The obtained analytical results not only demonstrated the powerful resolution of integration IEC fractionation with reversed-phase liquid chromatography (RPLC)-APCI/MS and MALDI-TOF/MS for analysis of compounds in a complex sample, but also exhibited the superiority of APCI/MS and MALDI-TOF/MS for identification of low-mass compounds, such as for study of traditional Chinese medicines (TCMs) and metabolome.  相似文献   

13.
Ambient mass spectrometry, pioneered with desorption electrospray ionization (DESI) technique, is of increasing interest in recent years. In this study, a corona discharge ionization source is adapted for direct surface desorption chemical ionization of compounds on various surfaces at atmospheric pressure. Ambient air, with about 60% relative humidity, is used as a reagent to generate primary ions such as H(3)O(+), which is then directed to impact the sample surface for desorption and ionization. Under experimental conditions, protonated or deprotonated molecules of analytes present on various samples are observed using positive or negative corona discharge. Fast detection of trace amounts of analytes present in pharmaceutical preparations, viz foods, skins and clothes has been demonstrated without any sample pretreatment. Taking the advantage of the gasless setup, powder samples such as amino acids and mixtures of pharmaceutical preparations are rapidly analyzed. Impurities such as sudan dyes in tomato sauce are detected semiquantitatively. Molecular markers (e.g. putrescine) for meat spoilage are successfully identified from an artificially spoiled fish sample. Chemical warfare agent stimulants, explosives and herbicides are directly detected from the skin samples and clothing exposed to these compounds. This provides a detection limit of sub-pg (S/N > or = 3) range in MS2. Metabolites and consumed chemicals such as glucose are detected successfully from human skins. Conclusively, surface desorption atmospheric pressure chemical ionization (DAPCI) mass spectrometry, without toxic chemical contamination, detects various compounds in complex matrices, showing promising applications for analyses of human related samples.  相似文献   

14.
Desorption electrospray ionization mass spectrometry (DESI-MS) was used as a simple and rapid way to analyze drug tablets and powders without sample preparation. Experiments were performed with a home-made DESI source coupled to a triple-quadrupole linear-ion trap (QqQ(LIT)) mass spectrometer. Twenty-one commercial drugs as well as some illicit Ecstasy tablets and powders were analyzed. MS spectra almost exclusively showed the protonated or deprotonated ion of the drug after directing the pneumatically assisted electrospray onto the tablet's surface. With some tablets, inhomogeneity of the surface resulted in different spectra depending on the spot analyzed, thus showing that DESI could be used for imaging. Directly triggered MS/MS spectra were used for confirmatory analysis, with analysis times often below 10 s per tablet. For illicit Ecstasy tablets, DESI-MS, GC/MS and LC/MS analyses provided similar qualitative results for the main analytes. With MS/MS spectra library comparison or exact mass measurements, this technique could become very powerful for the rapid analysis of unknown tablets and shows the great potential of desorption techniques as an alternative to solution-based analysis.  相似文献   

15.
Some glycosides of hydroxylysine, viz., alpha-1, 2-glucosylgalactosyl-O-hydroxylysine and beta-1-galactosyl-O-hydroxylysine, appear to be good indicators of collagen turnover. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method is proposed for measuring these analytes in urine, with no sample preparation except for a dilution step. Quantitation is performed using external calibration with no internal standard. A preliminary survey indicates good intra- and inter-day reproducibility (better than 5 and 8%, respectively). With the present method, the estimated limits of detection (S/N > 3) in urine are 0.8 and 0.5 microM/L for beta-1-galactosyl-O-hydroxylysine and alpha-1,2-glucosylgalactosyl-O-hydroxylysine, respectively. The method is proposed as a robust tool for a large-scale research investigation on collagen turnover.  相似文献   

16.
Ion suppression is a well-known phenomenon in electrospray ionization (ESI) mass spectrometry. These suppression effects have been shown to adversely affect the accuracy and precision of quantitative bioanalytical methods using ion spray. Such suppression effects have not been as well defined in atmospheric pressure chemical ionization (APCI) and there is some debate whether these effects actually occur in the ionization process using APCI. Here an example is described where clear ion suppression was observed during studies on a model compound and three metabolites using APCI liquid chromatography/tandem mass spectrometry (LC/MS/MS).  相似文献   

17.
A mass spectrometry based method for the simultaneous determination of an in vivo Greenford-Ware or 'GW cocktail' of CYP450 probe substrates and their metabolites in both human plasma and urine is described. The probe substrates, caffeine, diclofenac, mephenytoin, debrisoquine, chlorzoxazone and midazolam, together with their respective metabolites and stable isotope labelled internal standards, are simultaneously extracted from the biological matrix using solid phase extraction in 96-well microtitre plate format, automated by means of a custom built Zymark robotic system. The extracts are analysed by fast gradient high performance liquid chromatography (HPLC) with detection by tandem mass spectrometry (MS/MS) using thermally and pneumatically assisted electrospray ionisation in both positive and negative ion modes and selected reaction monitoring. The methods are specific, accurate and precise with intra- and inter-assay precision (%CV) of less than 15% for all analytes.  相似文献   

18.
Direct probe in vacuo chemical ionization (isobutane CI-MS) and Pyroprobe atmospheric pressure chemical ionization (APCI-MS) are complementary techniques for the analysis of polymeric materials. Both techniques can generally be used to detect residual chemicals and more volatile additives (via thermal desorption), as well as polymeric components (via pyrolysis).Isobutane CI-MS is often a “softer” technique than APCI-MS, giving less background, less fragmentation, and more predictable and reproducible spectra. APCI, on the other hand, provides a higher maximum temperature and a means to carry out sample heating at atmospheric pressure (to simulate TGA). Pyroprobe APCI with high performance instruments has the added features of high resolution mass measurement (to determine atomic compositions) and tandem mass spectrometry (MS/MS, to obtain fragmentation patterns).  相似文献   

19.
A self-aspirating, liquid microjunction surface sampling probe/electrospray emitter mass spectrometry system was demonstrated for use in the direct analysis of spotted and dosed drugs and their metabolites in thin tissue sections. Proof-of-principle sampling and analysis directly from tissue without the need for sample preparation was demonstrated first by raster scanning a region on a section of rat liver onto which reserpine was spotted. The mass spectral signal from selected reaction monitoring was used to develop a chemical image of the spotted drug on the tissue. The probe was also used to selectively spot sample areas of sagittal whole-body tissue from a mouse that had been dosed orally (90 mg/kg) with R,S-sulforaphane 3 h prior to sacrifice. Sulforaphane and its glutathione and N-acetyl cysteine conjugates were monitored with selected reaction monitoring and detected in the stomach and various other tissues from the dosed mouse. No signal for these species was observed in the tissue from a control mouse. The same dosed-tissue section was used to illustrate the possibility of obtaining a lane scan across the whole-body section. In total, these results illustrate the potential for rapid screening of the distribution of drugs and metabolites in thin tissue sections with the liquid micro-junction surface sampling probe/electrospray mass spectrometry approach. Published in 2007 by John Wiley & Sons, Ltd.  相似文献   

20.
A fully automated interface to couple high-performance thin-layer chromatography (HPTLC) with mass spectrometry (MS) is described. This universal hands-free interface connects intact normal-phase plates to any liquid chromatography/mass spectrometry (LC/MS) system without any adjustments or modifications to the mass spectrometer. The interface extracts the complete substance band with its depth profile and thus allows detections in the pg/band range. The high performance of the automated interface was evaluated through caffeine quantification in real samples, viz., energy drinks and pharmaceutical tablets, without internal standard. Following chromatographic separation on silica gel 60 F(254) HPTLC plates, caffeine bands were eluted from the plate by means of the automated interface to the electrospray ionization (ESI) source of a triple-quadrupole mass spectrometer. Since in full scan mode only the protonated molecule [M+H](+) was observed, caffeine quantification was performed using the selected-ion monitoring (SIM) mode at m/z 195. The validation showed highly reliable results for the linear range (R(2) = 0.9973), repeatability (RSD = 5.6%, n = 6) and intermediate precision (RSD = 1.5%, n = 3). Regarding accuracy the results obtained by HPTLC/MS were not statistically different (F-test, t-test) from those obtained by validated HPTLC/UV methods. Hence, this interface proved to be one of the most reliable and universal interfaces for HPTLC/MS.  相似文献   