首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Mercury exists in two forms in environment, inorganic salts and organic compounds. Determination of mercury is very important, due to its health effects. In the present research, diphenylation of mercury using phenylboronic acid as a derivatization reagent was used for the determination of Hg(II) in real water samples. A simple, rapid and cheap method named dispersive liquid–liquid microextraction was used for the extraction of analyte under the following conditions: extraction solvent 16 μL of carbon tetrachloride, disperser solvent 1 mL of ethanol and sample volume 5 mL. Under the optimal conditions, the enrichment factor for diphenylmercury was 931 and the limit of detection calculated on the basis of five replicates was 0.004 μg mL−1. The repeatability of the method expresses as relative standard deviation was 5.1 (n = 6). The linear range was between 0.01 and 10 μg mL−1. The performance of the proposed technique was evaluated for the determination of mercury in different environmental water samples.

  相似文献   

2.
A simple, sensitive, fast and efficient method based on dispersive liquid–liquid microextraction (DLLME) followed by ion mobility spectrometry (IMS) has been proposed for preconcentration and trace detection of carbamazepine (CBZ) in formulation samples. In this method, 1 mL of methanol (disperser solvent) containing 80 μL of chloroform (extraction solvent) was rapidly injected by a syringe into a sample. After 5 min centrifugation, the preconcentrated carbamazepine in the organic phase was determined by IMS. Development of DLLME procedure includes optimization of parameters influencing the extraction efficiencies such as kind and volume of extraction solvent, disperser solvent and salt addition, centrifugation time and pH of the sample solution. The proposed method presented good linearity in the range of 0.05–10 μg mL?1 and the detection limit was 0.025 μg mL?1. The repeatability of the method expressed as relative standard deviation was 6 % (n = 5). This method has been applied to the analysis of carbamazepine formulation samples with satisfactory relative recoveries ≤75 %.  相似文献   

3.
Extraction and determination of estrogens in water samples were performed using alcoholic-assisted dispersive liquid–liquid microextraction (AA-DLLME) and high-performance liquid chromatography (UV/Vis detection). A Plackett–Burman design and a central composite design were applied to evaluate the AA-DLLME procedure. The effect of six parameters on extraction efficiency was investigated. The factors studied were volume of extraction and dispersive solvents, extraction time, pH, amount of salt and agitation rate. According to Plackett–Burman design results, the effective parameters were volume of extraction solvent and pH. Next, a central composite design was applied to obtain optimal condition. The optimized conditions were obtained at 220 μL 1-octanol as extraction solvent, 700 μL ethanol as dispersive solvent, pH 6 and 200 μL sample volume. Linearity was observed in the range of 1–500 μg L?1 for E2 and 0.1–100 μg L?1 for E1. Limits of detection were 0.1 μg L?1 for E2 and 0.01 μg L?1 for E1. The enrichment factors and extraction recoveries were 42.2, 46.4 and 80.4, 86.7, respectively. The relative standard deviations for determination of estrogens in water were in the range of 3.9–7.2 % (n = 3). The developed method was successfully applied for the determination of estrogens in environmental water samples.  相似文献   

4.
《Analytical letters》2012,45(16):2518-2524
A reversed-phase high performance liquid chromatographic method was improved for the simultaneous determination of theobromine, paraxanthine, theophylline, and caffeine in urine. The method includes a liquid-liquid extraction at alkaline pH with ethylacetate. The 7-(2,3-dihidroxypropyl) theophylline was used as an internal standard (ISTD). The separation was achieved on a C18 column using 14:86 methanol:buffer (25 mM KH2PO4 adjusted to pH 4 with ortho-phosphoric acid) solution as mobile phase under isocratic conditions at a flow rate 1 mL min?1. An ultraviolet absorption at 274 nm was monitored. In these conditions, the LOD was 0.03 μg mL?1 for theobromine, 0.02 μg mL?1 for paraxanthine, 0.04 μg mL?1 for theophylline, and 0.08 μg mL?1 for caffeine. The method has been applied to urine samples.  相似文献   

5.
A simple, rapid and efficient method termed dispersive liquid–liquid microextraction combined with liquid chromatography-fluorescence detection, has been developed for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) in water and fruit juice samples. Parameters such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were optimized. Under optimum conditions, the enrichment factors ranged from 296 to 462. The linear range was 0.01–100 μg L?1 and limits of detection were 0.001–0.01 μg L?1. The relative standard deviations (RSDs, for 5 μg L?1 of PAHs) varied from 1.0 to 11.5% (n = 3). The relative recoveries of PAHs from tap, river, well and sea water samples at spiking level of 5 μg L?1 were 82.6–117.1, 74.9–113.9, 77.0–122.4 and 86.1–119.3%, respectively. The relative recoveries of PAHs from grape and apple juice samples at spiking levels of 2.5 and 5 μg L?1 were 80.8–114.7 and 88.9–123.0%, respectively. It is concluded that the proposed method can be successfully applied for determination of PAHs in water and fruit juice samples.  相似文献   

6.
《Analytical letters》2012,45(8):1434-1447
The use of disposable pipette extraction was examined for the simple and rapid determination of seven high explosives (cyclotrimethyl-enetrinitramine, cyclotetramethyl-enetetranitramine, 2,4,6-trinitrophenyl-methylnitramine, 2,4,6-trinitrotoluene, 2,4-dinitrotoluene, nitroglycerin, and pentaerythritol tetranitrate) in water. The current study involved the determination of slightly polar and nonpolar explosives in water with a reversed phase sorbent followed by high performance liquid chromatography. The method was based on a styrene divinylbenzene sorbent loosely placed inside a 5-mL pipette tip. Water samples were drawn into the tip and mixed with the sorbent. Air bubbles were also drawn through the tip following sample solution to enhance mixing. Because disposable pipette extraction uses small amounts of sorbent, minimal solvent is required to elute analytes and solvent evaporation is not necessary. The method provided rapid sample preparation, and required less than five minutes to extract 1.0 mL of water sample in the current study. Matrix-matched calibration was performed, and the limits of detection (LOD) were determined to be below 0.1 µg mL?1 for all targeted explosives in water with an enrichment factor of two. Coefficients of determination (r2) were greater than 0.9990 for all studied explosives, and the recoveries ranged from 69.76% to 87.51%, 83.77% to 91.25%, and 83.62% to 98.99% for samples spiked at 0.25 µg mL?1, 1.0 µg mL?1, and 5.0 µg mL?1, respectively. The relative standard deviations of recoveries at all spiked levels were below 8.97%. These results indicate that the disposable pipette extraction method provided good accuracy and precision for the determination of explosives in water.  相似文献   

7.
A fast and effective preconcentration method for extraction of organochlorine pesticides (OCPs) was developed using a homogeneous liquid–liquid extraction based on phase separation phenomenon in a ternary solvent (water/methanol/chloroform) system. The phase separation phenomenon occurred by salt addition. After centrifugation, the extraction solvent was sedimented in the bottom of the conical test tube. The OCPs were transferred into the sedimented phase during the phase separation step. The extracted OCPs were determined using gas chromatography–electron capture detector. Several factors influencing the extraction efficiency were investigated and optimized. Optimal results were obtained at the following conditions: volume of the consolute solvent (methanol), 1.0 mL; volume of the extraction solvent (chloroform), 55 μL; volume of the sample, 5 mL; and concentration of NaCl, 5 % (w/v). Under optimal conditions, the preconcentration factors in the range of 486–1,090, the dynamic linear range of 0.01–100 μg L?1, and the limits of detection of 0.001–0.03 μg L?1 were obtained for the OCPs. Using internal standard, the relative standard deviations for 1 μg L?1 of the OCPs in the water samples were obtained in the range of 4.9–8.6 % (n = 5). Finally, the proposed method was successfully applied for extraction and determination of the OCPs in water and fruit samples.  相似文献   

8.
Dispersive liquid–liquid microextraction (DLLME) for extraction and preconcentration of phenoxyacetic acid herbicides in water samples is described. After adjusting the pH to 1.5, the sample was extracted in the presence of 10% w/v sodium chloride by injecting 1 mL acetone as disperser solvent containing 25 μL of chlorobenzene as extraction solvent. The effect of parameters, such as the nature and amount of extraction and disperser solvents, ionic strength of the sample, pH, temperature and extraction time were optimized. DLLME was followed by LC for the determination of 2,4-dichlorophenoxyacetic acid and 4-chloro-2-methyl phenoxyacetic acid. The method had good linearity and a wide linear dynamic range (0.5–750 μg L?1) with a detection limit of 0.16 μg L?1 for both the PAAs, making it suitable for their determination in water samples.  相似文献   

9.
A novel method, dispersive liquid–liquid microextraction coupled with liquid chromatography-variable wavelength detector (LC-VWD), has been developed for the determination of chloramphenicol (CAP) in honey. A mixture of extraction solvent (30 μL 1,1,2,2-tetrachloroethane) and dispersive solvent (1.00 mL acetonitrile) were rapidly injected by syringe into a 5.0 mL real sample for the formation of cloudy solution, the analyte in the sample was extracted into the fine droplets of C2H2Cl4. After extraction, phase separation was performed by centrifugation and the enriched analyte in the sedimented phase was determined by LC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 3 to 2,000 μg kg?1 for target analyte. The enrichment factor for CAP was 68.2, and the limit of detection (S/N = 3) were 0.6 μg kg?1. The relative standard deviation (RSD) for the extraction of 10 μg kg?1 of CAP was 4.3% (= 6). The main advantages of method are high speed, high enrichment factor, high recovery, good repeatability and extraction solvent volume at μL level. Honey samples were successfully analyzed using the proposed method.  相似文献   

10.
A new method, termed dispersive liquid–liquid microextraction (DLLME), was developed for the extraction and pre-concentration of estrone (E1) and 17β-estradiol (E2) in water samples. The samples were extracted by 0.50 mL methanol (disperser solvent) containing 25.0 μL tetrachloroethane (extraction solvent). Important factors such as the volume and type of extraction and disperser solvent, extraction time and salt effect were studied. Under optimum conditions, the enrichment factors and the limits of detection were 347 and 0.2 ng mL?1 for E1, and 203 and 0.1 ng mL?1 for E2, respectively. The linear range was 0.5–5,000 ng mL?1. Compared to other methods, DLLME–LC–VWD has advantages for E1 and E2 analysis in water: high enrichment factor, low cost, simplicity, quick and easy operation.  相似文献   

11.
A novel analytical technique termed ultrasonic-assisted drop-to-drop solvent microextraction (USA-DDSME) in a capillary tube was developed to determine trace benzene, toluene, xylene in one drop of a water sample, which was combined with gas chromatography–flame ionization detection (GC–FID). The advantages of this method are rapidity, convenience, ease of operation, simplicity of the device, and extremely little solvent and sample consumption. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, the volume of sample, extraction time and effect of salt concentration were optimized. The best optimum parameters for extraction were achieved with 3 μL of extraction solvent. Chloroform was divided into four equal divisions in 20 μL water sample (without salt addition) in a capillary tube and ultrasonicated for 10 min, centrifugated at 2,500 rpm for 5 min to let the extraction solvent settle at the bottom of the capillary tube, then 1 μL of the separated extraction solvent was injected into the GC–FID for analysis. Linearity of the method was determined by analyzing spiked water samples over a concentration range of 0.1–50 μg mL?1. Correspondingly, the LOD values were 0.01 μg mL?1. All calibration curves were found to have good linearity with correlation coefficients (r 2) > 0.995. The precision (RSD) of the system, measured by six repeated determinations of the analytes at 1 μg mL?1 were in the range of 1.6–3.5%.  相似文献   

12.
A novel, fast and efficient method for the analysis of nitroaniline isomers as model compounds was developed using vortex-assisted supramolecular solvent liquid–liquid microextraction (VA-SMS-LLME). A vortex mixer was used as the mixer in supramolecular solvent liquid–liquid microextraction, and it decreased the extraction time greatly. Several important parameters influencing extraction efficiency, such as the type and volume of extraction solvent, pH of sample, salt effect and extraction time, were optimised in detail. Under the optimal conditions, the enrichment factor was 133 for p-nitroaniline, 98 for m-nitroaniline and 115 for o-nitroaniline, and the limits of detection by HPLC were 0.3, 1.0 and 0.5 μg L?1, respectively. Linearity with determination coefficient from 0.9981 to 0.9993 was evaluated using water samples spiked with the nitroanilines at fourteen different concentration ranging from 4 to 1000 μg L?1. The ranges of intra-day and inter-day precision (n = 5) at 10 μg L?1 of nitroanilines were 1.67–7.05% and 9.4–11.6%, respectively. The VA-SMS-LLME method was successfully applied for preconcentration of nitroanilines in environmental water samples.  相似文献   

13.
In the present study, an environment-friendly sample preparation method termed ionic liquid-based dispersive liquid–liquid microextraction combined with flame atomic absorption spectrometry has been developed for the determination of Pb(II) ion in water samples prior to flame atomic absorption spectrometry determination. In this method, ionic liquid was used as an extraction solvent instead of the organic solvent used in the conventional dispersive liquid–liquid microextraction (DLLME) assay, and there is no need for a chelating agent. Several variables that may affect extraction efficiencies, including pH, the volume of ionic liquid, the type and volume of disperser solvent, salt addition, and the time for centrifugation and extraction were studied and optimised. Under the optimised conditions, the calibration curve exhibited linearity over the range of 20.0–1000.0 μg L?1. The enrichment factor and the limit of detection based on 3Sb/m were 35.0 and 5.9 μg L?1, respectively. Seven replicate determination of a solution containing of 100.0 μg L?1 Pb(II) ions gave a relative standard deviation of ±2.1%. Finally, the feasibility of the proposed method for Pb(II) determination was assessed by the analysis of certi?ed reference material and various water samples and the satisfactory results were obtained.  相似文献   

14.
Simultaneous derivatization and dispersive liquid–liquid microextraction technique for gas chromatographic determination of fatty acids in water samples is presented. One hundred microlitre of ethanol:pyridine (4:1) were added to 4 mL aqueous sample. Then a solution containing 0.960 mL of acetone (disperser solvent), 10 μL of carbon tetrachloride (extraction solvent) and 30 μL of ethyl chloroformate (derivatization reagent) were rapidly injected into the aqueous sample. After centrifugation, 1 μL sedimented phase with the analytes was analyzed by gas chromatography. The effects of extraction solvent type, derivatization, extraction, and disperser solvents volume, extraction time were investigated. The calibration graphs were linear up to 10 mg L?1 for azelaic acid (R 2 = 0.998) and up to 1 mg L?1 for palmitic and stearic acids (R 2 = 0.997). The detection limits were 14.5, 0.67 and 1.06 μg L?1 for azelaic, palmitic, and stearic acids, respectively. Repeatabilities of the results were acceptable with relative standard deviations (RSD) up to 13%. A possibility to apply the proposed method for fatty acids determination in tap, lake, sea, and river water was demonstrated.  相似文献   

15.
Dispersive liquid–liquid microextraction (DLLME) based on the solidification of floating organic droplets (DLLME-SFO) combined with gas chromatography-electron-capture detection (GC–ECD) has been developed for extraction and analysis of three dinitrobenzenes. The extraction conditions including extraction solvent, disperser solvent, extraction time, salt effect and temperature were investigated and optimized systematically. The limits of detection were 0.019 μg L?1 for 1,4-dinitrobenzene, 0.079 μg L?1 for 1,3-dinitrobenzene and 0.034 μg L?1 for 1,2-dinitrobenzene. Moreover, it offered good repeatability and high recovery. This method was successfully applied to monitor DNBs in different water samples.  相似文献   

16.
A novel, efficient, and environmentally friendly method—supramolecular solvent liquid–liquid microextraction (SMS-LLME) combined with high-performance liquid chromatography (HPLC)—was first established for the determination of p-nitrophenol and o-nitrophenol in water samples. Several important parameters influencing extraction efficiency, such as the type and volume of extraction solvent, pH of sample, temperature, salt effect, extraction time, and stirring rate, were optimized in detail. Under the optimal conditions, the enrichment factor was 166 for p-nitrophenol and 160 for o-nitrophenol, and the limits of detection by HPLC were 0.26 and 0.58 μg L?1, respectively. Excellent linearity with coefficients of correlation from 0.9996 to 0.9997 was observed in the concentration range of 2–1,000 μg L?1. The ranges of intra- and interday precision (n = 5) at 100 μg L?1 of nitrophenols were 5.85–7.76 and 10.2–11.9 %, respectively. The SMS-LLME method was successfully applied for preconcentration of nitrophenols in environmental water samples.  相似文献   

17.
A dispersive liquid–liquid microextraction (DLLME) method for separation/preconcentration of ultra trace amounts of Co(II) and its determination with FAAS was developed. The DLLME behavior of Co(II) using Aliquat 336-chloride as ion pairing agent was systematically investigated. The factors influencing the ion pair formation and extraction by DLLME method were optimized. Under the optimized conditions for 150 µL of extraction solvent (carbon tetrachloride), 1.5 mL disperser solvent (acetonitrile) and 5 mL of sample, the enrichment factor was 30. The detection limit was 5.6 µg L?1 and the RSD for replicate measurements of 1 mg L?1 was 1.32 %. The calibration graph using the preconcentration system for cobalt was linear from 40 to 400 µg L?1 with a correlation coefficient of 0.999. The proposed method was successfully applied for determination of cobalt in black tea, paprika and marjoram real samples.  相似文献   

18.
A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL?1 for ibuprofen, 0.001–1.0 μg mL?1 for naproxen, and 0.01–10.0 μg mL?1 for fenbufen. The limits of detection were 0.5 ng mL?1 for ibuprofen, 0.05 ng mL?1 for naproxen and 0.5 ng mL?1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.  相似文献   

19.
A green and sensitive dispersive liquid-phase microextraction procedure based on room-temperature ionic liquid (1-hexyl-3-methylimidazolium hexafluorophosphate) for preconcentration and determination of total iron in real samples prior to flame atomic absorption spectrometry was developed. 2-Mercaptopyridine-N-oxide (pyrithione) and ethanol were used as complexing agent and dispersive solvent in the proposed method, respectively. The factors influencing the extraction were optimized. Under optimum conditions, the enhancement factor of 15 was obtained from only 11.35 mL of aqueous phase. The linear dynamic range and the detection limit were 10.0–700 and 2.4 μg L?1, respectively. The relative standard deviation (RSD) for ten replicate measurements of 500 μg L?1 of iron is 3.1 %. The developed method has been successfully applied for the determination of iron in water samples, human blood serum and rock certified reference material with high efficiency.  相似文献   

20.
A simple, sensitive high performance liquid chromatographic method with UV detection was developed and validated for determination of insulin in rat plasma, using methyl paraben as an internal standard. Insulin was extracted from plasma by a liquid–liquid extraction with a mixture of dichloromethane and n-hexane (1:1, v/v) followed by an acidic back extraction. Chromatographic separation was achieved isocratically with a Phenomenex® C18 analytical column (150 × 4.6 mm ID, 5 μm) at ambient room temperature. The calibration curves were linear within a concentration range of 0.7–8.4 μg mL?1 (r 2 = 0.9994). The inter-day and intra-day accuracy and precision were ≤3.33 and ≤5.55%. The limit of detection (LOD) and limit of quantification (LOQ) were 0.35 and 0.7 μg mL?1. The average recovery was 87.86% for insulin and 83.52% for methyl paraben. Insulin containing plasma samples were stable at ?20 °C for 7 days. Validated HPLC method was successfully applied to a pharmacokinetic study of insulin in streptozotocin induced diabetic rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号