首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Polycyclic aromatic hydrocarbons (PAH) and their nitrated derivatives (nitro-PAH) are environmental pollutants which pose a threat to human health even at low concentration levels. In this study, efficient analytical methods for the analysis of nitro-PAH and PAH (extraction, clean-up, chromatographic separation, and spectrometric detection) have been developed, characterized, and applied to aerosol samples. The separation and quantification of 12 nitro-PAH was carried out by reversed-phase high performance liquid chromatography (HPLC), on-line reduction, and fluorescence detection. The detection limits were in the range of 0.03–0.5 g L–1 (6–100 pg in the investigated sample aliquots), and the recovery rates from soot samples were 70–90%. Nitro-PAH and PAH concentrations have been determined for different types of soot and for urban, rural, and alpine fine air particulate matter (PM2.5). For the first time, trace amounts of nitro-PAH have been detected in a high-alpine clean air environment. The on-line reduction and fluorescence technique has been complemented by atmospheric pressure chemical ionization time-of-flight mass spectrometry (APCI-TOF-MS). The MS detection allowed the analysis of partially nitrated and oxygenated PAH in laboratory studies of the heterogeneous reaction of PAH on soot and glass fiber substrates with gaseous nitrogen oxides and ozone. It led to the tentative identification of a previously unknown nitrated derivative of the particularly toxic PAH benzo[a]pyrene (BaP-nitroquinone), and provides the first experimental evidence that PAH-nitroquinones can be formed by reaction of PAH with atmospheric photooxidants.  相似文献   

2.
A method for determination of nitrated polycyclic aromatic hydrocarbons (NPAHs) in diesel soot by high-performance liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization (APCI) and detection by ion-trap following ultrasonic extraction is described. The determination of 1-nitropyrene that it is the predominant NPAH in diesel soot was emphasized. Vaporization and drying temperatures of the APCI interface, electronic parameters of the MS detector and the analytical conditions in reversed-phase HPLC were optimized. The patterns of fragmentation of representative NPAHs were evaluated by single and multiple fragmentation steps and negative ionization led to the largest signals. The transition (247-->217) was employed for quantitative analysis of 1-nitropyrene. Calibration curves were linear between 1 and 15 microgL(-1) with correlation coefficients better than 0.999. Typical detection limit (DL) of 0.2 microgL(-1) was obtained. Samples of diesel soot and of the reference material (SRM-2975, NIST, USA) were extracted with methylene chloride. Recoveries were estimated by analysis of SRM 2975 and were between 82 and 105%. DL for 1-nitropyrene was better than 1.5 mg kg(-1), but the inclusion of an evaporation step in the sample processing procedure lowered the DL. The application of the method to diesel soot samples from bench motors showed levels 相似文献   

3.
Abstract

The soluble organic fraction (SOF) of particulate matter from diesel exhaust (from point sources, ambient air, etc.) contains hundreds of organic constituents. Normal-phase high pressure liquid chromatography (HPLC) has been used to separate the SOF into sub-fractions suitable for subsequent chemical analysis and bioassays. These fractions consist of non-polar(PAH), moderately polar (transition) and highly polar constituents. The non-polar fractions have been well characterized and consist of PAH and aliphatic hydrocarbons. The specific compounds present in the transition and polar fractions are for the most part unknown. This analytical information has been difficult to obtain since these compounds are highly labile, polar, of low volatility and in very low concentrations when compared to the bulk of material found in the SOF. Mutagenicity tests using the Ames Salmonella typhimurium assay indicate that the transition fraction accounts for most of the mutagenicity when compared to the non-polar (PAH) and polar fractions.

A variety of chromatographic and mass spectrometric techniques are described that have been used to determine the composition of the HPLC fractions. More than one hundred species have been identified in the transition fraction of diesel particulate matter using high resolution gas chromatography (HRGC)/high resolution mass spectrometry (HRMS), HPLC and direct-probe high resolution mass spectrometry. It has been found that the transition fraction contains mostly PAH derivatives consisting of hydroxy, ketone, quinone, carboxaldehyde, acid anhydride and dihydroxy derivatives of PAH. Three nitro-PAH species have been tentatively identified and 1-nitropyrene positively identified in the transition fraction. The 1-nitropyrene was found to account for approximately 45% and 30% of the direct-acting mutagenicity observed for the transition fraction and total extract, respectively. The HPLC separation procedure was shown to give better than 95% recovery of the mass and mutagenic activity. The problem of PAH oxidation during the analytical procedures and possible effect on bioassay results are discussed.  相似文献   

4.
An analytical procedure is described for the fractionation of organic compounds present in environmental samples and the determination of nitro polyaromatic hydrocarbons (nitro-PAHs). Both low and high resolution liquid chromatography are employed for the prefractionation of the soluble organic fraction (SOF) extracted from particulate matter or gaseous pollutants collected on adsorption traps. High resolution gas chromatography is used to analyze four fractions containing alkanes, PAHs, nitro-PAHs, and other polar PAHs. Nitrogen-containing species are separated by GC and detected specifically using an alkali flame (NPD) detector. Flame ionization (FID) detection, GC-MS of positive ions, and negative ion chemical ionization MS of the whole fraction is used for the identification and quantitation of the various components. The composition of SOF extracted from particulate matter emitted from diesel exhausts is elucidated and a large number of nitro-PAHs identified by the combination of the various techniques.  相似文献   

5.
An extremely simple and sensitive method was developed for determination of nitrated polycyclic aromatic hydrocarbons (nitro-PAHs; mono-nitro-PAHs and dinitropyrenes) in diesel exhaust particles (DEPs) by gas chromatography-negative ion chemical ionisation tandem mass spectrometry (GC/NCI/MS/MS). We used two types of column in GC/NCI/MS/MS analysis. A polar column was used for determination of mono-nitro-PAHs, and a non-polar column was used for determination of dinitropyrenes and mono-nitro-PAHs except nitrofluoranthenes. The proposed method requires no clean-up procedure. The limits of detection ranged from 0.01 to 0.09 pg for all compounds tested. The applicability of the method to DEP samples was validated using diesel particulate standard reference materials (SRMs). Although DEPs contain complex matrices, all compounds could be detected easily in SRM2975 (diesel particulate matter) and SRM1975 (diesel particulate extract) without a clean-up procedure. The RSDs were less than 5% for all compounds examined. The quantitative results for SRMs exhibited good agreement with the available data in the literature. These results indicate that the proposed GC/NCI/MS/MS method is useful for determination of nitro-PAHs in DEP samples.  相似文献   

6.
《Analytical letters》2012,45(14):2646-2657
Abstract

The burning of organic residues and wastes in furnaces of cement industries has been an attractive and lucrative approach to eliminate stocks of these pollutants. There is a potential risk for producing PAH in the workplace of industries burning organic wastes, so that highly sensitive analytical methods are needed for monitoring the air quality of these environments. An official method for determination of PAH is based on liquid chromatography with fluorescence detection at fixed excitation and emission wavelengths. We demonstrate that a suitable choice of these wavelengths, which are changed during the chromatographic run, significantly improves the detectability of PAH in atmosphere and particulate matter collected in cement industries.  相似文献   

7.
A method has been developed for analysis of the highly potent polycyclic aromatic hydrocarbon (PAH) carcinogens dibenzo(a,l)pyrene, dibenzo(a,h)pyrene, and dibenzo(a,i)pyrene (molecular weight 302) present in small amounts in diesel and air particulate material. The method can also be used for analysis of the PAH benzo(a)pyrene, coronene, and perylene, for which reference and certified values are available for the standard reference materials used for validation of the method—SRM 1649a (urban dust) and SRM 2975 (diesel particulate matter). The only NIST values that have been published for these dibenzopyrene isomers in the analyzed SRM are reference values for dibenzo(a,i)pyrene and dibenzo(a,h)pyrene in SRM 1649a. The concentrations determined in the SRM were in good agreement with reported NIST-certified and reference values and other concentrations reported in the literature. Standard reference material 1650 (diesel particulate matter) was also analyzed. The method could not, however, be validated using this material because certification of SRM 1650 had expired. The method is based on ultrasonically assisted extraction of the particulate material, then silica SPE pre-separation and isolation, and, separation and detection by hyphenated LC–GC–MS. The method is relatively rapid and requires only approximately 1–5 mg SRM particulate material to identify and quantify the analytes. Low extraction recoveries for the analytes, in particular the dibenzopyrenes, when extracting diesel SRM 2975 and 1650 resulted, however, in the dibenzopyrenes being present in amounts near their limits of quantifications in these samples. The method’s limit of quantification (LOQ), based on analyses of SRM 1649a, is in the range 10–77 pg. By use of this method more than 25 potential PAH isomers with a molecular weight of 302 could be separated.  相似文献   

8.
Hashi Y  Wang TR  Du W  Lin JM 《Talanta》2008,74(4):986-991
A method using on-line enrichment and fast high-performance liquid chromatography (HPLC) with fluorescence detection has been developed and validated for the determination of polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulate samples. The evaporation step for sample preparation can be eliminated since this system allows the injection of 1000microL of sample solution. PAH recoveries were between 87% and 120% for spiked atmospheric particulate samples. The limit of detection was 0.02-0.23ng/mL (signal/noise ratio=3.3). There was good linear correlation between HPLC peak area and PAH concentration, with a linear range of 0.4-40ng/mL and correlation coefficients >0.997. Furthermore, compared to conventional approaches that include an evaporation step, the method proposed is acceptable for detecting PAHs in atmospheric particulate samples.  相似文献   

9.
谢园园  花磊  陈平  侯可勇  蒋吉春  王艳  李海洋 《色谱》2015,33(2):188-194
建立了一种气相色谱(GC)与单光子电离-飞行时间质谱(SPI-TOF MS)联用(GC/SPI-TOF MS)的分析方法。首先,设计了一种双层套管的传输管用于连接GC与SPI-TOF MS,实现了GC与单光子电离离子源的无缝连接。在此基础上,以n-十五烷标准品和苯/甲苯/二甲苯的标准气为对象,对电离源的重要电压参数进行了优化,得到了纯净的分子离子峰,实现了对各类有机物的快速和准确定性。最后,将该方法用于分析柴油中的挥发性与半挥发性有机物,获得了柴油组分的二维GC×SPI-TOF MS谱图。不需要复杂的谱图解析和数据处理,根据谱图中离子的质荷比(m/z)归纳了柴油的主要成分,包括脂肪烃、芳香烃和含量很低的苯并吡咯等含氮化合物;根据色谱的保留时间将柴油中的同分异构体区分开来。结果表明GC/SPI-TOF MS法是一种简单、有效的分析方法,非常适于柴油及复杂环境样品等的分析表征。  相似文献   

10.
A new procedure is developed for the extraction of polycyclic aromatic hydrocarbons (PAHs) from the particulate phase of cigarette smoke. The procedure applies solid-phase extraction using a Bond Elut CH cartridge as a sample preparation step. The efficiency of the cleanup procedure is verified using a gas chromatographic (GC)-high-resolution mass spectrometric (MS) technique, proving that no interference occurs in the PAHs' determination. The efficient cleanup allows GC detection using either high- or low-resolution MS detection. Enhanced sensitivity is obtained using GC-MS and selected ion monitoring. This new technique has several advantages over other reported techniques. The method is simple and robust and has good repeatability and accuracy. The estimated detection limit is 0.1 ng/cigarette for benzo[a]pyrene. In addition to that, the recovery from the smoke pad in which the smoke is collected is approximately 97% for all PAHs. Results for the PAH analyses for 1R5F, 1R4F, and 1R3 Kentucky reference cigarettes are reported in this study. These results provide useful evidence for clarifying the controversy about previously reported data.  相似文献   

11.
A new sampling method was developed to collect vapor-phase polycyclic aromatic compounds (PAHs) downstream of a diesel engine equipped with a diesel particulate filter (DPF). This configuration allowed us to collect separately the particulate phase, which was trapped inside the DPF, and the vapor phase, which was sampled downstream of the DPF. PAHs, which were not predominantly absorbed into the poor organic fraction of the diesel soot, but were rather physically sorbed on high energetic adsorption sites, should be extracted using very drastic extraction conditions Microwave-assisted extraction using solvent mixtures composed of pyridine and diethylamine were used to desorb particulate PAHs, and the total PAH amounts corresponded to a very low value, i.e., 8 μg g−1 or 0.24 μg km−1, with a predominance of low weight PAHs. For collection of the vapor phase, gas bubbling in an aqueous medium was preferred to conventional methods, e.g., trapping on solid sorbents, for several reasons: aqueous trapping allowed us to use a solid phase enrichment process (SPE) that permitted PAH sampling at the sub-picogram levels. Consequently, low volume sampling was possible even if the sampling duration was very short (20 min). Additionally, the amount of time saved for the analysis was considerable when coupling SPE to the analytical system (liquid chromatography with fluorimetric detection). Solvent consumption for the overall sampling and analytical processes was also drastically reduced. Experiments on a diesel engine showed that vapor phase samples collected downstream of the DPF contained all of the 15 target priority PAHs, even the heaviest ones. The total vapor-phase PAH amount was 6.88 μg N m−3 or 10.02 μg km−1, which showed that the gaseous fraction contains more PAHs than the particulate fraction. Partitioning coefficients (Kp) were estimated showing the predominance in the vapor phase of all the PAHs. However, the DPF technology effects a considerable decrease in the total PAH emission when compared to non-equipped diesel vehicles.  相似文献   

12.
Chlorinated polycyclic aromatic hydrocarbons (ClPAHs) have been discovered to represent ubiquitous environmental pollutants in the last decade. In the present study, sample pre-treatment and ionisation conditions associated with the gas chromatography/mass spectrometry (GC/MS) analysis of ClPAHs were evaluated. The optimal pre-treatment of ambient air particulate samples was achieved using fractionation over silica gel with 10% dichloromethane in n-hexane as the eluent. The optimised condition of GC/MS with electron impact ionisation permitted analysis of all target ClPAHs. Not all target ClPAHs were detected using GC/MS with negative chemical ionisation, although this technique exhibited greater sensitivity for several of the compounds compared to electron impact ionisation. The analytical method was applied to the survey of ClPAHs in atmospheric particulate matter obtained close to an industrial site and in a standard sample of tunnel dust. Fourteen and eighteen species of ClPAHs were detected in the industrial air samples and tunnel dust, respectively, confirming the capability of the method. The compositions of ClPAHs were significantly different between air samples and tunnel dust. It suggests that alternative emission sources rather than vehicle exhaust could play a significant role in the air.  相似文献   

13.
This is the first of a series of two papers intended to review the state-of-the-art knowledge on atmospheric PAHs, concerning their monitoring, sources and transformation processes in the atmosphere. The monitoring section briefly introduces this class of compounds, mainly focusing on the 16 PAHs indicated by the US-EPA as priority pollutants. These compounds undergo partitioning between the gas phase and particulate, which has to be considered in the choice of the sampling methodology. Furthermore, sampling artifacts may arise from further phase transfers inside the sampling device. After sampling, extraction, clean up and detection/quantification procedures will follow. They are closely related since the choice of the extraction technique will heavily condition the clean-up step, and both procedures will place demands on the performance of the detection technique (usually GC-MS or HPLC). This is particularly true in the case of complex samples such as those arising from atmospheric sampling. The sources of atmospheric PAHs are then discussed with a particular focus on receptor models, which can allow the apportionment of PAH sources based on concentration data that can be routinely obtained by pollution control networks.  相似文献   

14.
 A rapid less labour-intensive procedure for complete decomposition of tungsten bearing complex matrices by potassium pyrosulphate and its determination using toluene 3,4-dithiol and thiocyanate is reported. The analytical results of various standard reference materials are presented (Jasperoid GXR-1, Deposit GXR-3, copper mill head GXR-4, tin-tungsten ore IGS-26, Mo-W ore IGS-27, tungsten concentrate SRM-277, scheelite ore SRM-2430, reference tungsten ore TLG-1, CT-1, BH-1 and Mo-W ore MP-2) along with two manganese nodules (GSPN-2 and GSPN-3) recently introduced by the Chinese Academy of Geological Sciences and one Polish soil sample (SRM-2710). For most of the samples the agreement between the observed value and the published data have been found to be extremely good. Derivations have been noted in some samples where published concentrations are indicative values only, indicating that more data are still required to upgrade the status from proposed/unspecified to the certified level. Results of various statistical analyses (intermethod comparison, F-test and regression analysis) reveal that the methods are matrix dependent. Separation of tungsten from molybdenum is straightforward, hence can be used for a quality control programme and in the evaluation of reference materials. Received: 30 December 1996 / Revised: 12 March 1997 / Accepted: 15 March 1997  相似文献   

15.
Polycyclic aromatic hydrocarbons (PAHs) are common pollutants present in atmospheric aerosols and other environmental mixtures. They are of particular air quality and human health concerns as many of them are carcinogenic toxins. They also affect absorption of solar radiation by aerosols, therefore contributing to the radiative forcing of climate. For environmental chemistry studies, it is advantageous to quantify PAH components using the same analytical technics that are commonly applied to characterize a broad range of polar analytes present in the same environmental mixtures. Liquid chromatography coupled with photodiode array and high-resolution mass spectrometric detection (LC-PDA-HRMS) is a method of choice for comprehensive characterization of chemical composition and quantification of light absorption properties of individual organic compounds present in the environmental samples. However, quantification of non-polar PAHs by this method is poorly established because of their imperfect ionization in electrospray ionization (ESI) technique. This tutorial article provides a comprehensive evaluation of the quantitative analysis of 16 priority pollutant PAHs in a standard reference material using the LC–MS platform coupled with the ESI source. Results are further corroborated by the quantitation experiments using an atmospheric pressure photoionization (APPI) method, which is more sensitive for the PAH detection. The basic concepts and step-by-step practical guidance for the PAHs quantitative characterization are offered based on the systematic experiments, which include (1) Evaluation effects of different acidification levels by formic acid on the (+)ESI-MS detection of PAHs. (2) Comparison of detection limits in ESI+ versus APPI+ experiments. (3) Investigation of the PAH fragmentation patterns in MS2 experiments at different collision energies. (4) Calculation of wavelength dependent mass absorption coefficient (MACλ) of the standard mixture and its individual PAHs using LC-PDA data. (5) Assessment of the minimal injected mass required for accurate quantification of MACλ of the standard mixture and of a multi-component environmental sample.  相似文献   

16.
A method has been developed for determination of polycyclic aromatic hydrocarbons (PAH) in particulate matter from ambient air and diesel exhaust emissions. It is reproducible and accurate and, compared with similar methods for analysis of individual PAH components in complex matrices, it is relatively fast and simple. Single PAH components can be determined in samples of particulate matter from ambient air and diesel exhaust emissions with LOD of approximately 1 pg/sample. Further, sample throughput is high, because more than 20 samples can be extracted and prepared for analysis in one working (8-h) day. The particulate matter is subjected to ultrasound-assisted extraction, a technique that is shown to extract PAH from particulate material with efficiencies fully comparable with those of Soxhlet extraction. An aliphatic/PAH-enriched fraction is obtained by solid-phase extraction before isolation, separation, and identification/quantification of PAH by on-line liquid chromatography–gas chromatography–mass spectrometry. The method was validated by analysis of US National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM) 1649a, Urban Dust, and 2975, Diesel Particulate Matter. Results from the method are in good agreement with the NIST-certified PAH concentrations and with NIST reference PAH concentrations.  相似文献   

17.
An analytical procedure based on extraction by accelerated solvent extraction (ASE) followed by gas chromatography–mass spectrometry (GC/MS) analysis has been developed for the determination of particulate polycyclic aromatic hydrocarbons (PAHs) from large-volume water samples (20 L). The effect of temperature and number of cycles on the efficiency of ASE was investigated: the best results were obtained by using a temperature of 100°C and one static cycle. A mixture of hexane/acetone 1:1 (v/v) was used as extraction solvent. Mean total method recovery under optimized conditions was 85%. The developed methodology was applied to the analysis of suspended particulate matter from Lake Maggiore waters (north of Italy). Mean PAH concentrations in suspended particulate matter from Lake Maggiore ranged from 0.2 ng L−1 for anthracene to 18.7 ng L−1 for naphthalene.  相似文献   

18.
Twenty-three polycyclic aromatic hydrocarbons (PAH) were determined in atmospheric particulate matter in 4 places of the Paris area at several times of the year. Fractionation was performed by reversed-phase high-pressure liquid chromatography. Determination was done by recording emission or excitation fluorescence spectra via a stopped-flow technique. Triphenylene was also extemporaneously determined by its phosphorescence spectrum at low temperature. Among the PAH determined dibenz(e,ghi)perylene has not been detected before in atmospheric particulate matter. The 10 more abundant PAH ranged from 0.1 to 40 ng/m3 of filtered air. Concentrations in August are from 14 to 250 times less than in January depending on the PAH. The reasons for this difference of behaviour among the PAH were investigated with regard to their photochemical and non-photochemical reactivity.  相似文献   

19.
1-Nitropyrene (1-NP) is enriched in diesel exhaust particulate matter (DPM) relative to other sources of particulate matter (PM), and has been proposed as a marker for DPM. However, in ambient air, 1-NP concentrations are typically in the low pg/m(3) range. Therefore, collection of large volume air samples coupled with extensive sample clean-up procedures has been required to achieve adequate detection limits to measure 1-NP in ambient samples. We report here an improved LC-MS/MS method suitable for the detection and quantification of 1-NP in low volume ambient PM samples. The method involves ultrasonic extraction of ambient PM in organic solvent, concentration of the sample under reduced pressure, and two-dimensional HPLC analysis of the extract. 1-NP is isolated on the first HPLC column, then converted to 1-aminopyrene (1-AP) via online reduction in a column packed with a Pt/Rh catalyst. The 1-AP containing fraction from the first column is refocused on a trapping column, then eluted through a second HPLC column prior to MS/MS detection. Deuterated (d(9)) 1-NP (1-dNP) is added to each sample prior to extraction as an internal standard for quantification of 1-NP. The accuracy and precision of the assay, as applied to ambient particulate standard reference materials are 110+/-5.7% for SRM 1650b, 116+/-7.1% for SRM 2975, 108+/-5.8% for SRM 1649a, and 53+/-9.2% for SRM 1648. The analytical limit of detection was 152 fg on column, and analytical limit of quantitation 221 fg on column. To our knowledge, the sensitivity of this method is comparable with GC-NICI-MS methods while having the advantage of considerably less extensive sample preparation. This method is an approximately 10-fold improvement in sensitivity over HPLC methods utilizing fluorescence and/or chemiluminescence detection.  相似文献   

20.
Polycyclic aromatic hydrocarbons (PAH) are products of the incomplete combustion of organic materials and, therefore, occur ubiquitously in the environment and also in tobacco smoke. Since some PAH have been classified as carcinogens, it is important to have access to suitable analytical methods for biomarkers of exposure to this class of compounds. Past experience has shown that measuring a profile of PAH metabolites is more informative than metabolites of a single PAH. Assessment of environmental and smoking-related exposure levels requires analytical methods with high sensitivity and specificity. In addition, these methods should be fast enough to allow high throughput. With these pre-conditions in mind, we developed and validated a high-performance liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of phenolic metabolites of naphthalene, fluorene, phenanthrene and pyrene in urine of smokers and non-smokers. Sample work-up comprised enzymatic hydrolysis of urinary conjugates and solid-phase extraction on C18 cartridges. The method showed good specificity, sensitivity, and accuracy for the intended purpose and was also sufficiently rapid with a sample throughput of about 350 per week. Application to urine samples of 100 smokers and 50 non-smokers showed significant differences between both groups for all measured PAH metabolites, and strong correlations with markers of daily smoke exposure in smoker urine. Urinary levels were in good agreement with previously reported data using different methodologies. In conclusion, the developed LC-MS/MS method is suitable for the quantification of phenolic PAH metabolites of naphthalene, fluorene, phenanthrene, and pyrene in smoker and non-smoker urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号