首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Direct determination of trace metals in sea water by flame atomic absorption technique suffers from serious interferences caused by the high salt content. Separation of the metals from the matrix has been effected by chelation and extraction with ammonium pyrrolidine dithiocarbamate and methyl-isobutyl-ketone. Besides a separation preconcentration and increased sensitivity is achieved with this extraction. Organic substances and metal-organic complexes are destroyed with UV-radiation before extraction is carried out. Flameless atomic absorption has been tried using the Heated Graphite Furnace combined with a) a selective volatilization procedure, b) removing of sodium from the samples using hydrated antimon pentoxide (HAP). Both methods were used to remove the interfering substances (mainly sodium salt). All the techniques have been compared by analysing the same sea water samples, some of which were also analysed by other laboratories.
Bestimmung einiger Schwermetalle in Meereswasser durch Atomabsorptions-Spektralphotometrie
Zusammenfassung Die direkte Bestimmung der Spurenmetalle in Meereswasser durch Flammen-Atomabsorption wird durch den hohen Salzgehalt behindert. Die Abtrennung der Metalle von der Matrix wurde durch Komplexierung und Extraktion mit Ammoniumpyrrolidindithiocarbamat und Methylisobutylketon erreicht, wodurch außerdem eine Anreicherung und Steigerung der Empfindlichkeit erzielt wird. Organische Substanzen und metallorganische Komplexe können durch UV-Bestrahlung vor der Extraktion zerstört werden. Die flammenlose Technik mit Hilfe des erhitzten Graphitrohres wurde in Kombination mit a) einer selektiven Verdampfungsmethode und b) der Entfernung des Natriums mit hydratisiertem Antimonpentoxid eingesetzt. Alle Verfahren wurden an Hand der gleichen Wasserproben verglichen. Tests wurden auch von anderen Laboratorien durchgeführt.
This work was made possible by substantial grants from International Atomic Energy Agencies (IAEA) and from the Royal Norwegian Council for Scientific and Industrial Research.  相似文献   

2.
Summary The sample of seawater (51) is freed from solid particles, buffered at pH 5.6 and percolated through a column filled with ED3A. After sample passage 15 ml 1 M hydrochloric acid solution are pumped through the column to dissolve the concentrated ions. The final measurement using flame atomic absorption is carried out in the hydrochloric acid solution. The total labour time is less than 15 min. The standard deviations (4 analyses) for the determination of Cu, Pb and Zn (in the normal concentration range of 2–6 g · l–1) were 2–5%, 5% and 1–10%, the recoveries 100%, 102% and 104%, respectively. A concentration coefficient of 300–500 was obtained.On leave from Lisbon University, Portugal  相似文献   

3.
Summary For the determination of cadmium in culture water from toxicological experiments with marine organisms direct flameless atomic absorption spectrophotometry seems to be an appropriate method, because it is less complicated than any combination with an extraction method. Unfortunately, it cannot be applied in the g·l–1-range without modifications, because matrix effects lead to unacceptable variations in the results. It was found that these difficulties can be overcome by the addition of ammonium peroxodisulphate and sulphuric acid. A routine method basing on this effect has been developed.
Bestimmung von Schwermetallen im Meerwasser und in marinen Organismen durch flammenlose Atomabsorptions-Spektralphotometrie. VI. Cadmiumbestimmung in Kulturwässern von toxikologischen Experimenten mit Meeresorganismen
Zusammenfassung Zur Cadmiumbestimmung in Kulturwasser von toxikologischen Versuchen mit marinen Organismen scheint die direkte flammenlose Atomabsorptions-Spektralphotometrie besonders geeignet zu sein, denn sie ist weniger umständlich als jede Kombination mit einer Extraktionsmethode. Ohne Modifikationen kann die Direktbestimmung jedoch im g/l-Bereich nicht eingesetzt werden, denn Matrixeffekte bewirken allzu starke Streuungen der Meßergebnisse. Es wird gezeigt, daß ein Zusatz von Ammoniumperoxodisulfat und Schwefelsäure zur Probenlösung eine deutliche Verbesserung bewirkt. Eine Routinemethode wurde entwickelt, bei der von diesem Effekt Gebrauch gemacht wird.
  相似文献   

4.
Ohne Zusammenfassung
Determination of traces of zinc, cadmium and bismuth in pure copper by AAS
  相似文献   

5.
Summary The simultaneous determination of cadmium, lead and copper in whole blood by anodic stripping voltammetry is described. Different digestion procedures given in literature were examined. In addition, a sample pretreatment method which did not involve digestion was studied. Based on the experience with these methods two digestion procedures were developed. They utilize digestion with mixtures of nitric, perchloric and sulphuric acids, with and without pressure, respectively. Both methods are suitable for routine analysis of about 20 blood samples per day. Special attention was focussed on the completeness of the digestion, and the magnitude of the blank values. Low blank values and a high sensitivity allowed the determination of cadmium at the sub-ppb level with an electrolysis time of 5 min. The methods, which were controlled by recovery tests, were used to analyze blood samples from unexposed persons, and from workers suspected of exposure to cadmium.
Vergleich von Aufschlußverfahren für die Bestimmung von Schwermetallen (Cd, Cu, Pb) in Blut durch Anodic Stripping Voltammetrie
Zusammenfassung Verschiedene in der Literatur beschriebene Aufschlußverfahren wurden untersucht und zusätzlich ein Probenvorbereitungsverfahren ohne Aufschluß geprüft. Aufgrund der mit diesen Methoden gewonnenen Erfahrungen wurden zwei Aufschlußverfahren entwickelt, bei denen Mischungen von Salpeter-, Perchlor- und Schwefelsäure mit und ohne Anwendung von Druck eingesetzt werden. Beide Methoden eignen sich für die Routineuntersuchung von etwa 20 Blutproben je Tag. Besondere Aufmerksamkeit wurde der Vollständigkeit des Aufschlusses und der Größe der Blindwerte gewidmet. Niedrige Blindwerte und hohe Empfindlichkeit erlaubten die Bestimmung von Cadmium im sub-ppb-Bereich mit einer Elektrolysezeit von 5 min. Die Methoden wurden durch Wiederauffindungstests geprüft und für die Blutuntersuchung von Personen, die der Einwirkung von Cd ausgesetzt waren, sowie solchen, bei denen dies nicht der Fall war, angewendet.
  相似文献   

6.
Summary The appicability of flameless AAS to direct cadmium determinations in seawater samples is limited to a level of about 2g l–1 [22]. Thus, for lower concentrations, a combination with an extraction method has been tested. It has been shown that the extraction can well be carried out with ammonium pyrrolidine dithiocarbamate (APDC). However, several modifications of the well known APDC/MIBK-Method were necessary. The key for the method presented was the choice of an appropriate solvent (CCl4, C2Cl4) for the reagent as well as for its Cd-complex. Then a simple, sensitive and miniaturized method has been developed, which has then been applied to a few natural seawater samples.
Bestimmung von Schwermetallen im Meerwasser und in marinen Organismen durch flammenlose AtomabsorptionsspektralphotometrieVII. Ein einfaches Extraktionsverfahren zur Bestimmung extrem niedriger Cadmiumgehalte in kleinen Seewasserproben
Zusammenfassung Die direkte Bestimmung von Cadmium im Meerwasser durch flammenlose AAS stößt unterhalb einer Konzentration von 2g l–1 auf beträchtliche Schwierigkeiten [22]. Deshalb wurde eine kombinierte Methode erprobt, bei welcher das Metall zunächst extrahiert und dann mittels flammenloser AAS bestimmt wird. Es zeigte sich, daß die Extraktion gut mit Ammoniumpyrrolidindithiocarbamat (APDC) ausgeführt werden kann. Es wurden jedoch erhebliche Abwandlungen der wohlbekannten APDC-MIBK-Extraktionsmethode erforderlich. Erst als es gelang, ein geeignetes Solvens (CCl4, C2Cl4) sowohl für das APDC als auch für seinen Cd-Komplex zu finden, konnte eine einfache, empfindliche und miniaturisierte Bestimmungsmethode entwickelt werden, mit deren Hilfe dann der Cd-Gehalt einiger Meerwasserproben bestimmt wurde.
  相似文献   

7.
Summary A new device for automated sample injection in flameless AAS with graphite tubes had been investigated. Using solutions of Cd, Pb, Cu, and Ni the attainable precision, the carry-over factor by additional experiments with 89Sr, the lifetime of commercially available graphite tubes as well as the influence of some selected matrix types and a pyrolytic coating on the surface of the graphite tubes upon measured values had been studied. The results of these studies together with the hereby resulting advantages of the system and possible future applications are discussed.
Untersuchungen zur automatisierten flammenlosen Atomabsorptionsspektrometrie
Zusammenfassung Ein neuartiges Gerät zur automatischen Probendosierung bei der flammenlosen AAS mit Graphitrohren wurde untersucht. Mit Lösungen von Cd, Pb, Cu und Ni wurde die erreichbare Reproduzierbarkeit, der Verschleppungsfaktor durch zusätzliche Experimente mit 89Sr, die Lebensdauer kommerziell erhältlicher Graphitrohre, der Einfluß einiger ausgewählter Matrices sowie einer pyrolytischen Beschichtung der Oberfläche der Graphitrohre auf die Meßwerte ermittelt. Die Ergebnisse der Studien, die hieraus ersichtlichen Vorteile des Systems sowie zukünftige Einsatzmöglichkeiten werden diskutiert.
Presented at the 6th Annual Symposium on Recent Advances in the Analytical Chemistry of Pollutants, April 21–23, 1976; Vienna, Austria.  相似文献   

8.
Summary Beside ionic impurities, DI water contains non-ionic compounds, which mainly consist of the oxyhydrates of the elements Fe, Ti, and Si present as colloids. This paper describes an analytical method for Fe, which is based on a simple enrichment by evaporation and the subsequent determination by flameless AAS. It is demonstrated that DI water systems, which are mainly based on coprecipitation and ion exchange, remove the Fe from the main water only to a small extent. The Fe content in DI water shows significant variations.
Bestimmung von Eisen in hochreinem Wasser durch Atomabsorptionsspektroskopie
Zusammenfassung Neben ionischen Bestandteilen enthält selbst hochreines Wasser auch nicht-ionische Komponenten, hauptsächlich Oxidhydrate der Elemente Ti, Fe und Si, die als Kolloide vorliegen. Die analytische Bestimmung des Eisens durch Eindampfen in einer einfachen Anordnung mit anschließender flammenloser AAS wird beschrieben. Es wird gezeigt, daß DI-Wasseranlagen, die heute zumeist noch nach dem Prinzip der Mitfällung und anschließendem Ionenaustausch arbeiten, nur begrenzt kolloidal vorliegendes Eisen entfernen und daß das Reinstwasser in seinem Fe-Gehalt stärkeren Schwankungen unterworfen ist.
  相似文献   

9.
Summary The microtrace content of Cu, Zn, Ni, Co, Mn and Fe in NaClO4, KCl, KOH and KAl(SO4)2 · 12 H2O is determined by flame atomic absorption spectrometry after preceding preconcentration of the traces using the extraction system PMBP/MIBK. It is proved that the salt matrix does not affect the quantitative extraction of the traces. The method permits the determination of the traces in the concentration range of 10–3–10–6% with good precision (variation coefficient 2–8%) and accuracy.
Extraktions-Flammenatomabsorptions-Bestimmung von Mikrospuren von Cu, Zn, Ni, Co, Mn und Fe in Alkali-Salzen
Zusammenfassung Der Mikrospurengehalt von Cu, Zn, Ni, Co, Mn und Fe in NaClO4, KCl, KOH, und KAl(SO4)2 · 12H2O wurde durch Flammenatomabsorption nach Extraktionsanreicherung mit einer 1-Phenyl-3-methyl-4-benzoylpyrazolon-5 (PMBP)-Lösung in MIBK bestimmt. Die Salz-Matrix weist keinen störenden Einflu\ auf die quantitative Extraktion der Elementspuren auf. Die Bestimmung der Spuren im Konzentrationsgebiet von 10–3–10–6% erfolgt mit guter PrÄzision (Variationskoeffizient 2–8%) und Richtigkeit.
  相似文献   

10.
Summary An extraction technique is described for the determination of ppm concentrations of both hydrophobic and hydrophilic methylsiloxane compounds in water, based on a single extraction with a mixed solvent of (11) l-pentanol and methyl isobutyl ketone followed by the determination of the silicone compounds extracted into the mixed solvent by atomic absorption spectroscopy. The method is applicable over the concentration range 0.3–30 ppm Si. Standard deviation in the case of 10 ppm Si is 0.313.
Bestimmung von siliciumorganischen Verbindungen in Wasser mit Hilfe der Atomabsorptions-Spektralphotometrie
Zusammenfassung Zur Bestimmung von ppm-Konzentrationen an hydrophoben und hydrophilen Methylsiloxanverbindungen im Wasser wird ein Extraktionsverfahren beschrieben. Hierbei wird nach einfacher Extraktion mit l-Pentanol/Methylisobutylketon (11) das Silicium im Extrakt mit Hilfe der AAS bestimmt. Der erfaßbare Konzentrationsbereich liegt bei 0,3–30 ppm Si. Die Standardabweichung beträgt bei 10 ppm Si 0,313.
  相似文献   

11.
Summary The insolubility of sugars and fruit acids in MIBK allows the direct extraction of heavy metals by APDC from wine and similar products. With special precautions an accuracy of /+-5% can be obtained for Pb and Cd in the concentration range from 0.1–1 ppm and 1–10 ppb, respectively. Together with our experiences a brief survey of the most recent literature is also presented.
Das substöchiometrische Extraktionssystem MIBK/APDC und seine Anwendung auf die Direktbestimmung von Pb und Cd in Wein
Zusammenfassung Die Unlöslichkeit der Zucker und Fruchtsäuren in MIBK erlaubt die Direktextraktion von Schwermetallionen mittels APDC aus Wein und ähnlichen Produkten. Unter Beachtung besonderer Vorsichtsmaßnahmen wird für Pb im Bereich von 0,1–1 ppm und für Cd im Bereich 1–10 ppb eine Genauigkeit von ± 5% erhalten. Gleichzeitig wird zusammen mit unseren Erfahrungen ein kurzer Überblick über die neueste Literatur gegeben.
  相似文献   

12.
13.
Summary In natural waters, heavy metals such as Cd may be present in bound form. It is, therefore, important to consider chemical speciation, especially at low concentrations of the metal where a significant part can be bound by other trace constituents so tightly that it escapes several forms of its determination. It has been demonstrated that even the very strong complexant APDC is unable to leach out all of the heavy metal present in several coastal water samples from the German Bight.This paper describes a new micro method for the determination of total Cd in natural waters. First a small sample is dried in a polypropylene vial. Then the salt residue is heated to 90° C with a mixture of sulphuric and nitric acid for digestion of organic trace constituents (and oxidation of sulphides if present). After dilution subsamples are neutralized using an excess of NaHCO3 buffer solution. Extraction results are then independent from the possible slight variations of pH. The extractant, a solution of APDC in CCl4 is stable for weeks, and even the extract is stable for at least 16h. Precision is in the range of 7% at a concentration of 0.066 g Cd l–1; the detection limit is below 0.002 g l–1 and can be lowered, if necessary, by enlargement of the original sample. According to the sensitivity of the method the typical blank of 0.022 g Cd l–1 is high, but it is rather constant (mean variation from the mean: 0.0024 g l–1).Teil XI: Fresenius Z. Anal. Chem. 299, 206–207 (1979)  相似文献   

14.
15.
Summary With the well-known APDC-MIBK extraction of dissolved trace metals from aqueous solutions for AAS analysis only Cr6+ is determined, whereas practically no Cr3+ is extracted. This technique was therefore modified (PHP-buffer; pH 4.7–5.5; 80° C; 20 min reaction time) so that hexavalent and trivalent chromium can be extracted simultaneously into the organic phase, thus allowing determination of the percentage of each of these ionic species in water (hexavalent chromium being determined separately). A procedure for the modified extraction is described.
Analyse von gelöstem Cr3+ und Cr6+ in Wasser durch APDC-MIBK-Extraktion und Atomabsorptionsspektrometrie
Zusammenfassung Mit der bekannten APDC-MIBK-Extraktion gelöster Spurenmetalle aus wäßrigen Lösungen für die AAS-Analyse wird nur Cr6+ erfaßt, während Cr3+ praktisch nicht extrahiert wird. Die bisherige Methode wurde deshalb so modifiziert (PHP-Puffer; pH 4,7–5,5; 80° C; 20 min Reaktionszeit), daß mit dem sechswertigen auch das dreiwertige Chrom in die organische Phase extrahiert wird und so der Anteil beider lonenarten bestimmt werden kann (nach getrennter Bestimmung des Cr6+). Eine Arbeitsvorschrift wird angegeben.
  相似文献   

16.
Summary This paper presents results of an intercalibration of cadmium determination by means of flameless AAS in biological materials from toxicological experiments. Furthermore, the philosophy of this kind of investigation is discussed in some detail. The goal and the result of this investigation was a correspondence of the measurement results within an acceptable range. Contamination during further handling has been identified as the main reason for severe deviations. The authors made measurements in the labs of several colleagues. The equipment itself did not produce individual variations. Repeated intercomparison after elimination of identified systematic errors showed sufficient correspondence of the results.Teil XII: Fresenius Z. Anal. Chem.301, 294–299 (1980)  相似文献   

17.
Zusammenfassung Die inverse Voltammetrie ist für Schwermetallbestimmungen in Grund- und Leitungswasser geeignet. Das wird durch die Qualitätskriterien der Werte und den Vergleich mit atomabsorptionsspektrometrischen Messungen gezeigt. Beim Grundwasser tritt die Art der Probenahme als wichtige Einflußgröße hervor. Stagniertes Wasser in Hausinstallationen zeigt bis zu 10fache Konzentrationen, verglichen mit den durch kräftiges Abfließen erreichbaren Minimalwerten. Die Wassertemperatur ist hierfür eine gute Beurteilungshilfe.
Determination of lead, cadmium, copper and zinc in ground water and tap water by anodic stripping voltammetry
Summary Heavy metals in ground water and tap water can be determined by differential pulse anodic stripping voltammetry (DPASV). This is shown by the quality criteria of the results and by comparison with AAS values. Concentrations down to 0.1 g/l are detectable. The way of sampling turns out to be quite important for ground water results. Heavy metal content in tap water is influenced by the retention time in the domestic pipes. Stagnation values are up to ten times the minimum concentration measured after heavy discharge. Water temperature is shown to be a good criterion for heavy metal concentration in that case.
Diese Arbeit wurde von der Deutschen Forschungsgemeinschaft unterstützt.  相似文献   

18.
Ohne Zusammenfassung
Extraction of Sb(III) from strongly acid media and determination of Sb in copper, lead, zinc and cadmium by means of extraction/atomic-absorption spectrophotometry
  相似文献   

19.
Summary An atomic absorption spectrometric method has been developed for the determination of chromium, cobalt, copper, manganese and nickel in U3O8 by electrothermal atomization of 5 mg powder samples. Nanogram amounts of all the elements can be estimated with a precision ranging between 7–12%. The non-specific absorption due to U3O8 for these measurements is negligible. The use of graphite powder with U3O8 in equal or double the sample amount improves sensitivity for the analyte element and prolongs the life of the atomizer.
Direkte AAS-Bestimmung von Co, Cr, Cu, Mn und Ni in U3O8 durch elektrothermische Atomisierung
Zusammenfassung Das entwickelte AAS-Verfahren geht von pulverförmigen 5mg-Proben aus. Nanogramm-Mengen der genannten Elemente können mit einer Genauigkeit im Bereich von 7–12% bestimmt werden. Die durch U3O8 verursachte unspezifische Absorption ist zu vernachlässigen. Durch Graphitzusatz (in der gleichen oder doppelten Menge der Probe) wird die Empfindlichkeit der Bestimmung verbessert und die Lebensdauer des Atomizers verlängert.
  相似文献   

20.
Summary Traces of Hg, Ag and Cu were separated in the range of 0.5–500 g with blotting-paper collectors and were subsequently determined directly with energy dispersive X-ray fluorescence. For comparison, spectrophotometric determinations were carried out as well. The results were in good agreement. The collectors contained 0.2 mM ZnS, in case of Ag a thioureide collector was also employed. Limits of detection were 0.2 g Hg, 0.4 g Cu and 0.15 g Ag for the ZnS collector and 0.13 g Ag for the thioureide collector.
Verwendung von Flie\papier-Kollektoren zur Abtrennung und röntgenfluorescenzspektrometrischen Bestimmung von Schwermetallspuren (Cu, Hg, Ag) in Wasser und Abwasser
Zusammenfassung Hg, Ag und Cu im Bereich von 0,5–500 g wurden auf Flie\papier-Kollektoren abgetrennt und direkt durch energiedispersive Röntgenfluorescenzanalyse bestimmt. Die Ergebnisse wurden durch Spektralphotometrie überprüft. Die Kollektoren enthielten 0,2 mM ZnS, für Ag statt dessen auch Thioureid. Alle Ergebnisse waren in guter übereinstimmung. Die Nachweisgrenzen für den ZnS-Kollektor betrugen 0,2 g Hg, 0,4 g Cu, 0,15 g Ag; für den Thioureid-Kollektor 0,13 g Ag.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号