首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Xiaoqiang Liu 《Talanta》2009,77(4):1437-1443
Low picograms of the hormone 17β-estradiol were detected at an electrochemical immunosensor. This immunosensor features a gold nanoparticle|Protein G-(LC-SPDP)1-scaffold, to which a monoclonal anti-estradiol capture antibody was immobilised to facilitate a competitive immunoassay between sample 17β-estradiol and a horseradish peroxidase-labelled 17β-estradiol conjugate. Upon constructing this molecular architecture on a disposable gold electrode in a flow cell, amperometry was conducted to monitor the reduction current of benzoquinone produced from a catalytic reaction of horseradish peroxidase. This current was then quantitatively related to 17β-estradiol present in a sample. Calibration of immunosensors in blood serum samples spiked with 17β-estradiol yielded a linear response up to ∼1200 pg mL−1, a sensitivity of 0.61 μA/pg mL−1 and a detection limit of 6 pg mL−1. We attribute these favourable characteristics of the immunosensors to the gold nanoparticle|Protein G-(LC-SPDP) scaffold, where the gold nanoparticles provided a large electrochemically active surface area that permits immobilisation of an enhanced quantity of all components of the molecular architecture, while the Protein G-(LC-SPDP) component aided in not only reducing steric hindrance when Protein G binds to the capture antibody, but also providing an orientation-controlled immobilisation of the capture antibody. Coupled with amperometric detection in a flow system, the immunosensor exhibited excellent reproducibility.  相似文献   

2.
Eissa  Shimaa  Zourob  Mohammed 《Mikrochimica acta》2017,184(7):2281-2289
Microchimica Acta - The authors describe a voltammetric immunosensor for morphine (MOR) that is based on a graphene screen printed electrode (GSPE) modified with gold nanoparticles (AuNP) which...  相似文献   

3.
Photocurrent responses associated with the interfacial quenching of the photo-excited water-soluble zinc meso-tetra(4-carboxyphenyl)porphyrin (ZnTPPC) by ferrocene have been studied at a water|1,2-dichloroethane interface in the absence and in the presence of adsorbed gold nanoparticles. Upon addition of methanol, a mirror-like gold film is formed and an important enhancement of the photocurrent response can be observed. Intensity modulated photocurrent spectroscopy experiments (IMPS) have been performed, in order to deconvolute in the frequency domain the contribution from the competition between the recombination and the product separation arising after the electron transfer, and the attenuation associated with the resistance and interfacial capacitance (RC(int)) time constant of the cell.  相似文献   

4.
This work designed a simple, sensitive, and low-cost immunosensor for the detection of protein marker by using a carbon sphere/gold nanoparticle (CNS/AuNP) composite as an electrochemical label. The nanoscale carbon spheres, prepared with a hydrothermal method by using glucose as raw material, were used to load AuNPs for labeling antibody by electrostatic interaction, which provided a feasible pathway for electron transfer due to the remarkable conductivity. The disposable immunosensor was constructed by coating a polyethylene glycol (PEG) film on a screen-printed carbon-working electrode and then immobilizing capture antibody on the film. With a sandwich-type immunoassay format, the analyte and then the CNS/AuNP-labeled antibody were successively bound to the immunosensor. The bound AuNPs were finally electro-oxidized in 0.1 M HCl to produce AuCl(4)(-) for differential pulse voltammetric (DPV) detection. The high-loading capability of AuNPs on CNS for the sandwich-type immunorecognition led to obvious signal amplification. By using human immunoglobulin?G (IgG) as model target, the DPV signal of AuNPs after electro-oxidized at optimal potential of +1.40?V for 40?s showed a wide linear dependence on the logarithm of target concentration ranging from 10?pg mL(-1) to 10?ng mL(-1). The detection limit was around 9?pg mL(-1). The immunosensor showed excellent analytical performance with cost effectivity, good fabrication reproducibility, and acceptable precision and accuracy, providing significant potential application in clinical analysis.  相似文献   

5.
将抗体结合蛋白A和交联剂联硫基二(琥珀酰亚胺丙酸盐)(DTSP)组成的骨架修饰到电极表面,再将单克隆雌二醇抗体与骨架中的蛋白A相结合,制备出电化学免疫传感器.利用样品雌二醇与辣根过氧化酶所标记的雌二醇同传感器表面抗体的竞争性结合,将该传感器用于测定溶液中样品雌二醇的浓度;利用方波伏安法监测电化学还原辣根过氧化酶催化产生的苯醌分子的电流,以还原电流为纵坐标,以雌二醇浓度为横坐标绘制标准曲线.结果表明,雌二醇浓度在50~1 500ng.L-1范围内与方波伏安还原电流呈良好的线性关系,灵敏度为0.51μA.ng-1.L,检测限为50ng.L-1.所制备的免疫传感器良好的分析性能得益于蛋白A和DTSP所组成的骨架,该骨架能够增加免疫分子组分在电极表面的修饰量,并能够控制抗体在电极上的结合方位,使其抗原结合位点朝向电极外端,减少结合空间阻碍.  相似文献   

6.
The authors describe a disposable electrochemical immunosensor strip for the detection of the Japanese encephalitis virus (JEV). The assay is based on the use of a screen printed carbon electrode (SPCE) modified with carbon nanoparticles (CNPs) that were prepared from starch nanoparticles and deposited on the SPCE working electrode whose surface was functionalized with 3-aminopropyl triethoxysilane. Next, antibody of JEV was immobilized on the surfaces of the CNPs. The analytical performance of immunosensor strip was characterized using cyclic voltammetry (with hexacyanoferrate as the redox probe) and electrochemical impedance spectroscopy. The deposition of CNPs enhances the electron transfer kinetics and current intensity of the SPCE by 63% compared to an unmodified SPCE. Under optimized conditions, the calibration plot is linear within the 5–20 ng·mL?1 JEV concentration range, the limit of detection being 2 ng·mL?1 (at an S/N ratio of 3), and the assay time is 20 min. This immunosensor strip was successfully applied to the detection of JEV in human serum samples. It represents a cost-effective alternative to conventional diagnostic tests for JEV.
Graphical abstract A disposable carbon nanoparticles modified screen printed carbon electrode (SPCE) immunosensor strip for Japanese encephalitis virus (JEV) detection is described. A limit of detection of 2 ng·mL?1 and an assay time of 20 min were achieved.
  相似文献   

7.
A sensitive immunosensor using colloidal gold as electrochemical label is described. In this method, the capture protein was first immobilized on a carbon paste electrode surface through passive adsorption to bind quantitatively with corresponding antigen and colloidal gold labeled antibody to perform a sandwich assay. To detect the amount of the colloidal gold captured on the electrode surface, the colloid was first oxidized electrochemically to produce AuCl4 ions which were adsorbed strongly on the electrode surface. Adsorptive voltammetry was then employed for the determination of the adsorbed AuCl4 ions. A linear relationship between reduction wave peak current and the antigen concentration (human IgG) from 10 to 500 ng/ml is obtained with a detection limit of 4.0 ng/ml.  相似文献   

8.
An amperometric detector with a gold nanoparticle modified carbon paste electrode (GNMCPE) was applied applied to flow injection analysis for the determination of acetaminophen. An obvious shift of the peak potential and increase of the current peak were observed for the GNMCPE in comparison to that of the bare carbon paste electrode. The experimental conditions, such as species of buffer, pH, flow rate, detection volume, injection volume, and injection time were investigated. Under the optimized conditions, the calibration curve was obtained over the concentration range of 0.1–80 mg L?1 of acetaminophen with a linear correlation coefficient of 0.9994. The detection limit (3σ) was estimated to be 0.05 mg L?1 (n?=?7). The recoveries of acetaminophen were between 98.40% and 104.1%, and the relative standard deviation varied between 1.66% and 2.74% for the different samples. This method was applied to analyze six types of tablets obtained from a local drugstore. The contents of acetaminophen were found to be 0.498, 0.323, 0.249, 0.324, 0.319 and 0.323 g of each tablet, respectively. These results are consistent with the values obtained by high performance liquid chromatography.  相似文献   

9.
10.
11.
Hu SQ  Xie JW  Xu QH  Rong KT  Shen GL  Yu RQ 《Talanta》2003,61(6):769-777
An electrochemical immunosensor for the direct determination of paraoxon has been developed based on the biocomposites of gold nanoparticles loaded with paraoxon antibodies. The biocomposites are immobilized on the glassy carbon electrode (GCE) using Nafion membrane. On the immunosensor prepared paraoxon shows well-shaped CV with reduction and oxidation peaks located −0.08 and −0.03 mV versus SCE, respectively. The detection of paraoxon performed at −0.03 mV is beneficial for guaranteeing sufficient selectivity. The amount of the biocomposite consisting gold nanoparticles loaded with antibodies and the volume of Nafion solution used for fabricating the immunosensor have been studied to ensure sensitivity and conductivity of the immunosensor. The immunosensor has been employed for monitoring the concentrations of paraoxon in aqueous samples up to 1920 μg l−1 with a detection limit of 12 μg l−1.  相似文献   

12.
Adsorption of cytochrome c (Cyt c) on a gold nanoparticle – modified gold electrode was studied by using cyclic voltammetry, electrochemical impedance spectroscopy and chronopotentiometry in a phosphate buffer solution. It is shown that the charge transfer resistance is directly proportional to the amount of adsorbed Cyt c. The effects of temperature and time on the course of adsorption were also studied. The trends obtained in ΔGADS showed that Cyt c was found to have a smaller affinity for the modified electrode as indicated by their smaller negative ΔGADS values.  相似文献   

13.
Gold nanoparticles were deposited electrolessly on multiwalled carbon nanotubes (CNTs) via in situ reduction of HAuCl4 by NaBH4. The resulting gold covered nanotubes were immobilised onto the surface of a glassy carbon electrode via evaporation of a suspension in chloroform. Anodic stripping voltammetry was performed with the modified electrode in As(III) solutions. A limit of detection (LOD based on 3σ) of 0.1 μg L−1 was obtained but more importantly a sensitivity of 1985 μA μM−1 was obtained with square wave voltammetry (SWV) in an optimised system with a deposition time of 120 s. These values, particularly the high sensitivity compare favourably with previously reported methods in the area of electrochemical arsenic detection.  相似文献   

14.
We describe a multiplex electrochemical immunoassay based on the use of gold nanoparticle (Au-NP) probes and immunochromatographic strips (ISs). The approach takes advantage of the speed and low cost of the conventional IS tests and the high sensitivities of the nanoparticle-based electrochemical immunoassays. Rabbit IgG (R-IgG) and human IgM (H-IgM) were used as model targets for the demonstration of the proof of concept. The Au-NPs based sandwich immunoreactions were performed on the IS, and the captured gold nanoparticle labels on the test zones were determined by highly sensitive stripping voltammetric measurement of the dissolved gold ions (III) with a carbon paste electrode. The detection limits are 1.0 and 1.5 ng ml−1 with the linear range of 2.5–250 ng ml−1 for quantitative detection of R-IgG and H-IgM, respectively. The total assay time is around 25 min. Such multiplex electrochemical immunoassay could be readily highly multiplexed to allow simultaneous parallel detection of numerous proteins and is expected to open new opportunities for protein diagnostics and biosecurity.  相似文献   

15.
Kong FY  Xu MT  Xu JJ  Chen HY 《Talanta》2011,85(5):2620-2625
In this paper, gold nanoparticle-thionine-reduced graphene oxide (GNP-THi-GR) nanocomposites were prepared to design a label-free immunosensor for the sensitive detection of carcinoembryonic antigen (CEA). The nanocomposites with good biocompatibility, excellent redox electrochemical activity and large surface area were coated onto the glassy carbon electrode (GCE) surface and then CEA antibody (anti-CEA) was immobilized on the electrode to construct the immunosensor. The morphologies and electrochemistry of the formed nanocomposites were investigated by using scanning electron microscopy (SEM), ultraviolet-visible (UV-vis) spectrometry, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). CV and differential pulse voltammetry (DPV) studies demonstrated that the formation of antibody-antigen complexes decreased the peak current of THi in the GNP-THi-GR nanocomposites. The decreased currents were proportional to the CEA concentration in the range of 10-500 pg/mL with a detection limit of 4 pg/mL. The proposed method was simple, fast and inexpensive for the determination of CEA at very low levels.  相似文献   

16.
The first-known aptamer for the stress biomarker cortisol was selected using a tunable stringency magnetic bead selection strategy. The capture DNA probe immobilized on the beads was systematically lengthened to increase the number of bases bound to the complementary pool primer regions following selection enrichment. This resulted in a single sequence (15–1) dominating the final round 15 pool, where the same sequence was the second-highest copy number candidate in the enriched pool with the shorter capture DNA probe (round 13). A thorough analysis of the next-generation sequencing results showed that a high copy number may only correlate with enhanced affinity under certain stringency and enrichment conditions, in contrast with prior published reports. Aptamer 15–1 demonstrated enhanced binding to cortisol (K d?=?6.9?±?2.8 μM by equilibrium dialysis; 16.1?±?0.6 μM by microscale thermophoresis) when compared with the top sequence from round 13 and the negative control progesterone. Whereas most aptamer selections terminate at the selection round demonstrating the highest enrichment, this work shows that extending the selection with higher stringency conditions leads to lower amounts eluted by the target but higher copy numbers of a sequence with enhanced binding. The structure-switching aptamer was applied to a gold nanoparticle assay in buffer and was shown to discriminate between cortisol and two other stress biomarkers, norepinephrine and epinephrine, and a structurally analogous biomarker of liver dysfunction, cholic acid. We believe this approach enhances aptamer selection and serves as proof-of-principle work toward development of point-of-care diagnostics for medical, combat, or bioterrorism targets.  相似文献   

17.
Different promoters were used to enhance the rate of the electron transfer process of superoxide dismutase (SOD). A quasi-reversible cyclic voltammogram (CV) of SOD was observed on the cysteine-modified gold wire electrode. The coupled adsorption/desorption processes and the characteristic Raman spectra of different states of SOD molecules on the electrode surface were studied with electrochemical quartz crystal microbalance (EQCM) and in-situ Raman spectroelectrochemical techniques. The possible promotion mechanism was discussed.  相似文献   

18.
Nanometer sized materials have been shown to possess excellent chemical and electrochemical catalytic properties. In this work, a gold nanoparticle (AuNP) modified indium tin oxide (ITO) electrode was employed for investigating its electro-catalytic property. AuNP was deposited on the 3-aminopropyltriethoxysilane (APTES) modified ITO electrode by self-assembly, and was characterized by scanning electron microscopy and cyclic voltammetry. Although the electrochemical reaction of dopamine was very sluggish on the ITO/APTES electrode, it was significantly enhanced after AuNP deposition. The cyclic voltammogram exhibited apparent dependence on the surface coverage of 11 nm AuNPs, which could be rationalized by different modes of mass diffusion. Among the different sizes of AuNP investigated, the lowest anodic peak potential was observed on 11 nm AuNP. However, the potential was still about 50 mV more positive than that obtained on a bulk gold electrode of similar geometry. It is therefore concluded that there is no nanometer size effect of AuNP modified ITO on the electrochemistry of dopamine.  相似文献   

19.
Xun Mao  Yan Luo 《Talanta》2007,73(3):420-424
We demonstrate herein a novel electrochemical protocol for quantification of human IgG based on the precipitation of copper on gold nanoparticle tags and a subsequent electrochemical stripping detection of the dissolved copper. The immunoassay was conducted by following the typical procedure for sandwich-type immunoreaction. Goat anti-human IgG was immobilized on the wells of microtiter plates. The human IgG analyte was first captured by the primary antibody and then sandwiched by secondary antibody labeled with gold nanoparticles. The copper enhancer solution was then added to deposite copper on the gold nanoparticle tags. After dissolved with HNO3, the released copper ions were then quantified by ASV. The detection limit is 0.5 ng/mL by 3σ-rule. In order to investigate the feasibility of the newly developed technique to be applied for clinical analysis, several standard human IgG serum specimens were also examined by the method. To our knowledge, the copper enhancing procedure is the first time to be developed for immunoassay. The new strategy of using copper-enhanced gold nanoparticle tags for electrochemical stripping detection holds great promise for immunoassay and DNA detection.  相似文献   

20.
The immobilization of anti-IgG on Au-colloid modified gold electrodes has been investigated. A cleaned gold electrode was first immersed in a mercaptoethylamine (AET) solution, and then gold nanoparticles were chemisorbed onto the thiol groups of the mercaptoethylamine. Finally, anti-IgG was adsorbed onto the surface of the gold nanoparticles. Potentiometric immunosensor, cyclic voltammetry, and electrochemical impedance techniques were used to investigate the immobilization of anti-IgG on Au colloids. In the impedance spectroscopic study, an obvious difference of the electron transfer resistance between the Au-colloid modified electrode and the bare gold electrode was observed. The cyclic voltammogram tends to be more irreversible with increased anti-IgG concentration. Using the potentiometric immunosensor, the proposed technique is based on that the specific agglutination of antibody-coated gold nanoparticles, averaging 16 nm in diameter, in the presence of the corresponding antigen causes a potential change that is monitored by a potentiometry. It is found that the developed immunoagglutination assay system is sensitive to the concentration of IgG antigen as low as 12 ng mL(-1). Experimental results showed that the developed technique is in satisfactory agreement with the ELISA method, and that gold nanoparticles can be used as a biocompatible matrix for antibody or antigen immobilization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号