首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatographic method with UV detection has been developed for the determination of saikosaponin a in rat plasma. Saikosaponin a and internal standard jujuboside A were isolated from plasma samples by solid-phase extraction. The chromatographic separation was achieved on a reversed-phase C(18) column with the mobile phase of acetonitrile-water (35:65, v/v) at a flow rate of 1 mL/min and UV detection was set at 205 nm. The standard curve for saikosaponin a was linear over the concentration range 0.25-10 microg/mL and the limit of detection was 0.05 microg/mL. The absolute recovery was greater than 82%. The precision and accuracy ranged from 3.05 to 9.59% and 95.61 to 110.00%, respectively. The validated method was used to determine saikosaponin a in plasma samples in a pharmacokinetic study of saikosaponin a administered to Sprague-Dawley rats.  相似文献   

2.
A simple and rapid high-performance liquid chromatographic method with UV detection is developed and validated to determine the concentration of voriconazole in rat and beagle dog plasma. After protein precipitation using acetonitrile, the supernatant solution is chromatographed on a Diamonsil C(18) column (250 x 4.6-mm i.d., 5 microm). The mobile phase used is a combination of acetonitrile-water-acetic acid (55:45:0.25, v/v/v) with a pH of 4.0. Detection is achieved by a UV detector monitored at a wavelength of 256 nm. The matrix calibration curves are obtained both in the concentration range of 0.10-50.0 microg/mL in rat and beagle dog plasma, with the lower limit of quantitation of 0.10 microg/mL. The intra- and inter-assay precisions in terms of % relative standard deviation are lower than 8.6% and 6.0% in rat and beagle dog plasma, respectively. The accuracy in terms of % relative error ranged from -0.5% to 8.0% and -0.5% to 6.0% in rat and beagle dog plasma, respectively. This validated method is successfully applied to determine the concentration of voriconazole in plasma after intravenous administration of 36 mg/kg voriconazole to rats and 10 mg/kg voriconazole to beagle dogs, respectively.  相似文献   

3.
An analytical method based on high-performance liquid chromatographic (HPLC) with ultraviolet (UV) detection was developed for determination of scopolin in rat plasma using aesculin as internal standard (IS). After protein precipitation of plasma sample with methanol, the supernatant was directly injected and analyzed. Chromatographic separation was achieved on a C18 column using methanol and distilled water (22:78, v/v) containing 0.2% (v/v) glacial acetic acid as mobile phase with a column temperature of 30 degrees C. The UV detector was set at 338 nm. The calibration curve was linear over the range of 0.105-13.125 microg/mL with a correlation coefficient of 0.9998. The retention times of aesculin and scopolin were 10.4 and 12.8 min, respectively. The recoveries for plasma samples of 0.105, 4.725 and 13.125 microg/mL were 91.08, 95.30 and 96.10%, respectively. The RSD of intra- and inter-day assay variations was less than 7.35%. The lower limit of detection was 0.03 microg/mL .This HPLC assay is a simple, sensitive and accurate and was successfully applied to the pharmacokinetic study of scopolin in rats.  相似文献   

4.
A rapid and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for determination of myrislignan in rat plasma after intravenous administration. The analytes extracted from plasma samples by solid-phase extraction were successfully carried out on a Diamonsiltrade mark ODS C(18) column (250 x 4.6 mm i.d., 5 microm) with an RP(18) guard column (8 x 4.6 mm i.d., 5 microm) and a mobile phase of MeOH-H(2)O (4:1, v/v). The UV detector was set at a single wavelength of 270 nm. The linear ranges of the standard curves were 0.5-30.0 microg/mL with the correlation coefficients greater than 0.9992. The lower limits of detection and quantification were 0.1 and 0.3 microg/mL for myrislignan. Intra- and inter-day precisions were 2.4-7.5 and 1.3-5.7%, respectively. The extraction recovery from plasma was more than 90%. This assay method has been successfully used to study the pharmacokinetics of myrislignan in rats.  相似文献   

5.
A simple and sensitive high-performance liquid chromatographic (HPLC) method is developed for the determination of osthole in rat plasma and applied to a pharmacokinetic study in rats after administration of Fructus Cnidii extract. After addition of fluocinonide as an internal standard, plasma samples are extracted with diethyl ether. HPLC analysis of the extracts is performed on a Hypersil ODS2 analytical column, using methanol-0.4% acetic acid (65:35, v/v) as the mobile phase. The UV detector is set at 322 nm. The standard curve is linear over the range 0.0520-5.20 microg/mL (r = 0.9979). The mean extraction recoveries of osthole at three concentrations were 81.0%, 91.2%, and 90.7%, respectively. The intra- and interday precisions have relative standard deviations from 1.9% to 4.9%. The limit of quantitation is 0.0520 microg/mL. The HPLC method developed can easily be applied to the determination and pharmacokinetic study of osthole in rat plasma after the animals are given the Fructus Cnidii extract. The plasma concentration of osthole from six rats showed a Cmax of 0.776 +/- 0.069 microg/mL at Tmax of 1.0 +/- 0.3 h.  相似文献   

6.
A simple, sensitive and selective RP-HPLC method has been developed for quantification of nodakenin in rat plasma. Nodakenin in rat plasma was extracted with acetonitrile, which also acted as a deproteinization agent. Chromatographic separation of nodakenin was performed on an analytical Diamonsil ODS C18 column, with a mobile phase of MeOH-H2O (1:1, v/v) at a flow-rate of 1.0 mL/min, and UV detection was set at 330 nm. The calibration curve was linear over the range 0.2-12.0 microg/mL (R2 = 0.9995) in rat plasma. The lower limit of detection and quantification were 0.01 and 0.1 microg/mL, respectively, using the rat plasma sample. The extraction recoveries were 77.36 +/- 4.56, 82.89 +/- 1.84 and 81.66 +/- 2.49% at concentrations of 1.0, 5.0 and 10.0 microg/mL, respectively. The intra- and inter-day precision and accuracy were validated by relative standard deviation and relative error, which were in the ranges 5.07-5.83 and 3.95-6.29%, respectively. After i.v. administration to rats at a single dose of 40 mg/kg, the plasma concentration-time curve of nodakenin was best conformed to a two-compartment open model. This assay method has been successfully applied to the study of the pharmacokinetics of nodakenin in rats.  相似文献   

7.
A simple, sensitive and selective high-performance liquid chromatographic (HPLC) method with UV detection (306 nm) was developed and validated for determination of tenatoprazole, a novel proton-pump inhibitor, in dog plasma. Tenatoprazole and internal standard (pantoprazole) were extracted into diethyl ether and separated using an isocratic mobile phase of 10 mm phosphate buffer (pH4.7)-acetonitrile (70:30, v/v) on a Diamonsil C(18) column (150 x 4.6 mm, 5 microm). The retention times for tenatoprazole and internal standard were 7.1 and 12.3 min, respectively. No endogenous interferences were observed. This HPLC method was fully validated. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 20%. A linear range of 0.02-5.0 microg/mL was established. The interday and intraday precisions were within RSD 13.4-10.1 and 4.6-1.4%, respectively. This method developed can be easily applied to the pharmacokinetic study of tenatoprazole in dog plasma after oral administration of an enteric-coated capsule. The plasma concentration of tenatoprazole from six dogs showed a mean C(max) of 2.63 microg/mL at T(max) of 1.89 h. The bioavailability of tenatoprazole was improved by administration of enteric-coated capsule.  相似文献   

8.
A validated reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the determination of bergenin in rat plasma. Bergenin in rat plasma was extracted with methanol, which also acted as a deproteinization agent. Chromatographic separation of bergenin was performed on a C(18) column, with a mobile phase of methanol-water (22:78, v/v) at a flow-rate of 0.8 mL/min and an operating temperature of 40 degrees C, and UV detection was set at 220 nm. The calibration curve was linear over the range 0.25-50 microg/mL (r = 0.9990) in rat plasma. The limit of quantification was 0.25 microg/mL using a plasma sample of 100 microL. The extraction recoveries were 83.40 +/- 6.02, 81.49 +/- 2.40 and 72.51 +/- 2.64% at concentrations of 0.5, 5 and 50 microg/mL, respectively. The intra-day and inter-day precision and accuracy were validated by relative standard deviation (RSD%) and relative error (RE%), which were in the ranges 3.74-9.91 and -1.6-8.0%. After intravenous administration to rats at the dose of 11.25 mg/kg, the plasma concentration-time curve of bergenin was best conformed to a two-compartment open model. The main pharmacokinetic parameters indicated that bergenin exhibited a wide distribution and moderate elimination velocity in rat.  相似文献   

9.
A simple and selective HPLC assay was developed and utilized for determination of human plasma protein binding of baicalin. The method involved solid-phase extraction and reversed-phase chromatographic separation with a mobile phase of acetonitrile-0.02 mol/L phosphate buffer (pH 2.5; 25:75, v/v) and UV detection at 276 nm. The standard curve for baicalin was linear over the concentration range 0.1-20 microg/mL and the limit of detection was 0.02 microg/mL. The absolute recovery was greater than 76%. The intra-day and inter-day variations were less than 10%. Ultrafiltration technique was applied to determining the plasma protein binding of baicalin in human plasma. Results show the plasma protein binding of baicalin was in the range 86-92% over all the concentrations studied and the protein binding association constant was determined to be 1.21 x 10(5) L/mol at 4 degrees C.  相似文献   

10.
An isocratic high-performance liquid chromatographic method with UV detection has been developed and validated for the quantitative determination of foscarnet in isoosmotic sodium chloride aqueous solution. The mobile phase consisted of mixture of methanol:water (30:70 v/v), containing 1 mm tetrahexylammonium hydrogen sulphate at pH 5.80. The analyte was separated on a reversed-phase C(18) column packed with 4 microm spherical particles of octadecylsilane. Hydrochlorothiazide was used as internal standard. UV detection at 232 nm allowed a quantification limit of 50 microg/mL. The assay was linear from 50 to 4000 microg/mL. The coefficient of variation was < or =2.52% for intra-assay precision and < or =3.49% for inter-assay precision. The deviation from the nominal value ranged from -0.57 to 0.47% for the same-day accuracy and from -0.75 to 3.06% for day-to-day accuracy.  相似文献   

11.
This research paper describes validated reversed-phase high-performance column liquid chromatographic (RP-HPLC) and first-derivative UV spectrophotometric methods for the estimation of voriconazole (VOR) in oral suspension powder. The RP-HPLC separation was achieved on Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using water-acetonitrile (40 + 60, v/v; pH adjusted to 4.5 +/- 0.02 with acetic acid) as the mobile phase at a flow rate of 1.4 mL/min and ambient temperature. Quantification was achieved with photodiode array detection at 255 nm over the concentration range of 0.1-1 microg/mL with mean recovery of 99.49 +/- 0.83% for VOR by the RP-HPLC method. Quantification was achieved with UV detection at 266 nm over the concentration range of 8-20 microg/mL with mean recovery of 99.74 +/- 0.664% for VOR by the first-derivative UV spectrophotometric method. These methods are simple, precise, and sensitive, and they are applicable for the determination of VOR in oral suspension powder.  相似文献   

12.
A reversed-phase high-performance liquid chromatographic (RP-HPLC) method was described for the determination of chlorogenic acid (CGA) in rat plasma using protocatechuic acid as internal standard (IS). CGA in plasma was extracted with acetonitrile, which also acted as deproteinization agent. Chromatographic separation was performed on a Kromasil C18 column with methanol-0.2 m acetic acid (pH 3.0, 25:75, v/v) as mobile phase at a flow-rate of 1.0 mL/min with an operating temperature of 30 degrees C and UV detection at 300 nm. The standard curve was found to be linear over the concentration ranges of 0.4-2.5 microg/mL and 2.5-40 microg/mL, and the limit of quantification (LOQ) was 0.4 microg/mL. The analytical precision and accuracy were validated by relative standard deviation (RSD) and relative error, which were in ranges 3.14-10.78% and -2.20-5.00%, respectively. The average recovery of CGA was 87.59%. The method was successfully applied to the pharmacokinetic study of CGA in Yin-Huang granules.  相似文献   

13.
A chromatographic method for baicalin quantification in rat thalamus   总被引:2,自引:0,他引:2  
A rapid reversed-phase high-performance liquid chromatographic (rp-HPLC) assay for the determination of baicalin in rat thalamus was developed. This was carried out on a Hypersil -C(18) column using 4-nitro-benzoic acid as the internal standard with a mobile phase of methanol-water-H(3)PO(4) (45:55:0.2, v/v/v). Detection was by UV at 277 nm. The calibration curve for baicalin was linear (r=0.9992) over the concentration range of 0.05--4.0 microg/mL and the limit of detection was 10 ng/mL. The coefficients of variation of intra- and inter-day assays were 2.64, 5.19 and 3.19% and 3.46, 6.21 and 5.58% at concentrations of 0.5, 1.0 and 3.0 microg/mL, respectively. The recoveries of baicalin from rat thalamus were 85.4+/- 5.62, 90.7+/- 2.43 and 89.1+/- 4.75% at concentrations of 0.5, 1.0 and 3.0 microg/mL, respectively. The method was applied to determine the time course of baicalin in rat thalamus, following a single dosage of intravenous administration of Scutellariae radix extract at 90 mg/kg of baicalin to male Wistar rats.  相似文献   

14.
A simple and reliable high-performance liquid chromatographic method with diode array detection has been developed and validated for the determination of insulin in human plasma. A good chromatographic separation was achieved on a C18 column with a mobile phase consisting of acetonitrile and 0.2M sodium sulfate (pH 2.4), 25:75 (v/v). Its flow rate was 1.2 mL/min. Calibration curve was linear within the concentration range of 0.15-25 μg/mL. Intra-day and inter-day relative standard deviations for insulin in human plasma were less than 6.3 and 8.5%, respectively. The limits of detection and quantification of insulin were 0.10 and 0.15 μg/mL, respectively. Also, this assay was applied to determine the pharmacokinetic parameters of insulin in eight insulin-dependent diabetes mellitus patients after subcutaneous injection of 25 IU of Actrapid HM.  相似文献   

15.
A liquid chromatographic method with diode array detection (DAD) has been developed for the analysis of the antiepileptic agent lamotrigine (LTG) and its metabolites, lamotrigine 2-N-glucuronide and 2-N-methylated in plasma samples. The analytes were separated on a C8 RP column, using a mobile phase composed of methanol and a 0.45 mM, pH 3.5 phosphate buffer containing 0.17% triethylamine (24:76 v/v). Melatonin was used as the internal standard (IS). The DAD detector was set at 220 nm for the detection of all the analytes. A simple protein precipitation with methanol guaranteed high extraction yield values (>90%) and good purification from matrix interference. Good linearity was obtained in the 0.1-15.0 microg/mL range for LTG and lamotrigine 2-N-glucuronide and in the 0.1-2.0 microg/mL range for lamotrigine 2-N-methylated. The analytical method was validated in terms of precision, extraction yield, and accuracy. These assays gave RSD% values for precision always lower than 4.3% and mean accuracy higher than 80%. The method seems to be suitable for the analysis of plasma samples from patients treated with Lamictal.  相似文献   

16.
An isocratic reversed-phase high performance liquid chromatographic method is developed and validated for the determination of 2-(diethylamino)-N-(2,6-dimethylphenyl) acetamide (0.3%, w/w) in a gel formulation. The chromatographic separation is achieved with potassium phosphate buffer (pH 7.0)-acetonitrile (47:53, v/v) as mobile phase, a C(18) column, and UV detection at 254 nm. The calibration curve is linear (r(2) = 1.000) from 20-140% of the analytical concentration of 1.4 microg/mL. The mean percent relative standard deviation values for intra- and interday precision studies are < 1%. The recovery ranges 99.95-100.23% from a gel formulation. The method is specific and successfully routinely used in quality control for the analysis of bulk gel samples and final product release.  相似文献   

17.
A reversed-phase high-performance liquid chromatographic (HPLC) assay for calycosin-7-O-beta-D-glucopyranoside in rat plasma and urine with solid-phase extraction (SPE) was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) at a flow rate of 1.0 mL/min. Detection was set at 280 nm. The limit of quantitation of calycosin-7-O-beta-D-glucopyranoside was 0.2 microg/mL in both plasma and urine. The standard curve was linear from 0.2 to 10.0 microg/mL in plasma, and 0.2 to 5.0 microg/mL in urine. Both intra- and inter-day precision of the calycosin-7-O-beta-d-glucopyranoside were determined and their RSD did not exceed 10%. The method was successfully applied to the analysis of samples obtained from a basic pharmacokinetic study, in which calycosin-7-O-beta-d-glucopyranoside was administered orally to rats.  相似文献   

18.
Four different stability-indicating procedures are described for determination of tiapride in pure form, dosage form, and human plasma. Second derivative (D2), first derivative of ratio spectra (1DD), spectrofluorimetric, and high-performance column liquid chromatographic (LC) methods are proposed for determination of tiapride in presence of its acid-induced degradation products, namely 2-methoxy-5-(methylsulfonyl) benzoic acid and 2-diethylaminoethylamine. These approaches were successfully applied to quantify tiapride using the information included in the absorption, excitation, and emission spectra of the appropriate solutions. In the D2 method, Beer's law was obeyed in the concentration range of 1.5-9 microg/mL with a mean recovery of 99.94 +/- 1.38% at 253.4 nm using absolute ethanol as a solvent. In 1DD, which is based on the simultaneous use of the first derivative of ratio spectra and measurement at 245 nm in absolute ethanolic solution, Beer's law was obeyed over a concentration range of 1.5-9 microg/mL with mean recovery 99.64 +/- 1.08%. The spectrofluorimetric method is based on the determination of tiapride native fluorescence at 339 nm emission wavelength and 230 nm excitation wavelength using water-methanol (8 + 2, v/v). The calibration curve was linear over the range of 0.2-3 microg/mL with mean recovery of 99.66 +/- 1.46%. This method was also applied for determination of tiapride in human plasma. A reversed-phase LC method performed at ambient temperature was validated for determination of tiapride using methanol-deionized water-triethylamine (107 + 93 + 0.16, v/v/v) as the mobile phase. Sulpiride was used as an internal standard at a flow rate of 1 mL/min with ultraviolet detection at 214 nm. A linear relation was obtained over a concentration range of 2-30 microg/mL with mean recovery of 99.66 +/- 0.9%. Results were statistically analyzed and compared with those obtained by applying the reference method. They proved both accuracy and precision.  相似文献   

19.
A new, simple, and reproducible method for determination of carboxylic acid metabolite of clopidogrel in human plasma has been developed. After liquid-liquid extraction in acidic medium with chloroform, samples were quantified on a Nova-pak C(8), 5 microm column using a mixture of 30 mM K(2)HPO(4)-THF-acetonitrile (pH = 3, 79:2:19, v/v/v) as mobile phase with UV detection at 220 nm. The flow rate was set at 0.9 mL/min. Ticlopidine was used as internal standard and the total run time of analysis was about 12 min. The method was linear over the range of 0.2-10 microg/mL of clopidogrel metabolite in plasma (r(2) > 0.999). The within-day and between-day precision values were in the range 1.0-4.8%. The limit of quantification of the method was 0.2 microg/mL. The method was successfully used to study the pharmacokinetics of clopidogrel in healthy volunteers.  相似文献   

20.
A sensitive and simple high-performance liquid chromatography method with UV detection was developed and validated for determining picroside II in dog plasma. Paeoniflorin was employed as internal standard and the sample pre-treatment procedure consists of deproteinization by addition of acetonitrile. Chromatographic separations were performed on a Shimadzu VP-ODS column (250 x 4.6 mm i.d., 5 microm). The mobile phase consisted of acetonitrile-0.1% acetic acid aqueous (v/v), 23:77, v/v, at a rate of 1 mL/min. Detection was carried out at a wavelength of 266 nm. Calibration standards ranged from 0.25 to 500 microg/mL in dog plasma and the mean correlation coefficient of 0.9981 was found for the linear calibration curves (n = 6). The limit of quantification (LOQ) was 0.25 microg/mL. Intra- and inter-assay RSD ranged from 0.70 to 7.5%. Accuracy (%bias) ranged from -6.3 to 6.0%. This method was applied to the pharmacokinetic study of picroside II in dogs. The study demonstrated the plasma picroside II concentration-time curves were fitted to the two-compartment open model and showed linear pharmacokinetics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号