首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
K&#;l&#;&#;  B.  &#;zden  T.  Toptan  S.  &#;zilhan  S. 《Chromatographia》2007,66(1):129-133

A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method was developed for the determination of zolmitriptan and N-desmethylzolmitriptan in human plasma. The analytes and the internal standard (IS) paroxetine were extracted by liquid–liquid extraction with a mixture of saturated ethyl acetate:dichloromethane (4:1) and were separated using an isocratic mobile phase on a XTerra RP18 column. The mobile phase used was acetonitrile: 5 mM ammonium acetate: formic acid (50:50:0.053, v/v/v). Zolmitriptan and N-desmethylzolmitriptan in a range of 0.25–20 ng mL−1 were easily quantified. The validated method can be applied to pharmacokinetic and bioequivalence studies.

  相似文献   

2.
&#;&#;leyen  E. A. &#;.  &#;zden  T.  &#;zilhan  S.  Toptan  S. 《Chromatographia》2007,66(1):109-113

A simple, rapid, sensitive and selective LC-MS method was developed and validated for quantification of fexofenadine in human plasma. The LC-MS system was operated under the positive electrospray ionisation mode (ESI). After liquid–liquid extraction, fexofenadine analysis was performed on a C18 column with a mobile phase of acetonitrile: 10 mM ammonium acetate: formic acid, 70:30:0.1 (v/v/v) at a flow rate of 1 mL min−1 by using loratadine as internal standard. The lower limit of quantitation was 3 ng mL−1 for fexofenadine. The assay precision ranged between 1.05 and 12.56% and accuracy ranged between 82.00 and 109.07%. The validated method was successfully used to analyze human plasma samples in bioequivalence studies.

  相似文献   

3.
Lu  Yingnian  Wu  Kefeng  Liang  Nianci  Chen  George G. 《Chromatographia》2009,70(11):1599-1603

ent-11α-Hydroxy-15-oxo-kaur-16-en-19-oic acid (5F), a diterpenoid isolated from the Chinese herb Pteris semipinnata L, has been suggested to show antitumor properties. A simple and sensitive LC method was developed for the determination of 5F in rabbit plasma. The method involved liquid–liquid extraction using ethyl acetate under acidic conditions using naproxen as an internal standard. Separations were performed on a reversed-phase column with a mixture of 1% (v/v) glacial acetic acid and methanol (45:55, v/v) as mobile phase and UV detection was utilized at 242 nm. The calibration plot was linear in the range 0.20–10.0 μg mL−1 (correlation coefficients r 2 > 0.998). The detection limit was 0.20 μg mL−1, mean extraction recovery was above 82%, intra-day precision of the method was less than 6.4%, and inter-day precision was better than 8.7%, respectively. The validated assay was found to be suitable for the pharmacokinetic study of 5F in rabbits.

  相似文献   

4.

A rapid, simple, sensitive and specific liquid chromatography–tandem mass spectrometry method was developed and validated for simultaneous quantification of itopride hydrochloride and domperidone in human plasma. Both drugs were extracted by liquid–liquid extraction with ethyl acetate and saturated borax solution. The chromatographic separation was performed on a reversed-phase C18 column with a mobile phase of water–methanol (2:98, v/v) containing 0.5% formic acid. The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The assay exhibited linearity over the concentration range of 3.33–500 ng mL−1 for itopride hydrochloride and 3.33–100 ng mL−1 for domperidone in human plasma. The precursor to product ion transitions of m/z 359.1–72.3 and 426.0–147.2 were used to measure itopride hydrochloride and domperidone respectively. The method was found suitable for the analysis of plasma samples collected during phase 1 pharmacokinetics study of itopride HCl 50 mg and domperidone 20 mg in 12 healthy volunteers after single oral doses of the combination drug.

  相似文献   

5.

A simple, sensitive and specific liquid chromatographic method with UV detection (228 nm) was developed for the simultaneous estimation of rosiglitazone and glimepride in human plasma. Rosiglitazone and glimepride were extracted from plasma using liquid–liquid extraction. Separation was achieved with an RP C18 Column using a mixture of phosphate buffer (50 mM) with octane sulfonic acid (10 mM), methanol and acetonitrile as a mobile phase (55:10:35, v/v). pH was adjusted to 7.0. Amlodipine was used as an internal standard (IS). LOD of the method was found to be 20 ng mL−1 for both drugs. Results were linear over the studied range 40.994–2007.556 ng mL−1 for rosiglitazone (r ≥ 0.99) and 41.066–2094.84 ng mL−1 for glimepride( r ≥ 0.99). The method was found to be simple, selective, precise and reproducible for the estimation of both drugs from spiked human plasma.

  相似文献   

6.
A simplified solid phase extraction method, eliminating a preliminary protein precipitation has been developed for the determination of celecoxib in rat plasma. The technique included a solid phase extraction of the serum samples on a [poly (divinylbenzene-co-N-vinylpyrrolidone)] sorbent. After conditioning, the cartridge was loaded with 0.5 mL of acidified serum containing internal standard. Elution was made with 1 mL of a mixture of acetonitrile and methanol (1/1, v/v). After evaporation of the eluate to dryness and reconstitution with methanol, the samples were analyzed on an octadecyl bonded phase with several mobile phases containing acetonitrile and a phosphate buffer. Detection was carried out using a Photodiode Array Detector. Full validation of the proposed method was provided (linearity range: 0.01–2 mg. L–1, average extraction efficiency: 92.4%; average intra-day variability: 4.6% with an accuracy of 94.8%; average interday variability: 5% with an accuracy of 95.3%, limit of detection: 0.005 mg. L–1, limit of quantification: 0.002 mg. L–1). The proposed method was successfully utilised to quantify celecoxib in rat plasma for a pharmacokinetic study.Revised: 26 January and 23 April 2004  相似文献   

7.
Dogan-Topal  B.  Uslu  B.  Ozkan  S. A. 《Chromatographia》2007,66(1):97-101

This paper describes the validation of an isocratic high-performance liquid chromatographic method for the assay of valganciclovir in raw materials, tablets and human serum samples. Valganciclovir and fluvastatin (internal standard) were well separated using a reversed phase column and a mobile phase consisting of a mixture of acetonitrile:methanol:KH2PO4 (0.02 M) (40:20:40; v/v/v) (at pH 5.0). The mobile phase was pumped at 1.0 mL min−1 flow rate and valganciclovir was detected by diode-array detection at 255 nm. The retention times for valganciclovir and fluvastatin were 3.41 and 5.60 min, respectively. A linear response (r > 0.999) was observed in the range of 10–30,000 ng mL−1 in mobile phase and serum. The limit of detection and limit of quantification were found as 2.95 and 9.82 ng mL−1 in mobile phase and 1.73 and 5.77 ng mL−1 in human serum samples, respectively. Validation parameters as precision, accuracy, selectivity, reproducibility and system suitability tests were also determined. The method can be used for valganciclovir assay of tablets and human serum samples as the method separates valganciclovir from tablet excipients and endogenous substances.

  相似文献   

8.
Du  Kehe  Wu  Caisheng  Ding  Chunguang  Zhao  Shanlin  Qin  Hailin  Zhang  Jinlan 《Chromatographia》2009,69(11):1259-1266

A rapid and specific high-performance liquid chromatographic method coupled with electrospray ionization mass spectrometric detection has been developed and validated for identification and quantification of wogonin and oroxylin A in rat plasma. Wogonin, oroxylin A, and diazepam (internal standard) were extracted from plasma samples by liquid–liquid extraction with ethyl acetate. Chromatographic separation was achieved on a C18 column with acetonitrile–0.6% aqueous formic acid 35:65 (v/v) as mobile phase at a flow rate of 0.2 mL min−1. Detection was performed with a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. Linearity was good within the concentration range 14.4–360 ng mL−1 for wogonin and 10.8–271 ng mL−1 for oroxylin A; the correlation coefficients (r 2) were 0.9999. The intra-day and inter-day precision, as RSD, was below 12.4%, and accuracy ranged from 81.1 to 111.9%. The lower limit of quantification was 14.4 ng mL−1 for wogonin and 10.8 ng mL−1 for oroxylin A. This method was successfully used in the first pharmacokinetic study of wogonin and oroxylin A in rat plasma after oral administration of the active fraction from Xiao-xu-ming decoction.

  相似文献   

9.
Chae  Yoon-Jee  Koo  Tae-Sung  Lee  Kyeong-Ryoon 《Chromatographia》2012,75(19):1117-1128

A liquid chromatography-mass spectrometry (LC-MS) assay was developed and validated for the quantification of lurasidone, an atypical antipsychotic drug, in rat plasma, bile, and urine. Rat plasma, bile, or urine samples were processed by liquid–liquid extraction and injected onto an LC-MS system for the quantification of lurasidone and ziprasidone (an internal standard). Lurasidone and ziprasidone were separated from endogenous substances using a Gemini C6-Phenyl column with mixture of acetonitrile and 0.1 % formic acid (80:20, v/v) as the mobile phase. Quantification was performed using the selected ion monitoring mode at m/z 493 for lurasidone and m/z 413 for the IS. The detector response was specific and linear for lurasidone in the concentration range 5–5,000 ng mL−1 The intra- and inter-day accuracy and precision of the method were determined to be within the acceptable criteria for assay validation guidelines. In addition, lurasidone was stable under a variety of processing and handling conditions. Lurasidone concentrations could be readily measured in rat plasma, bile, and urine samples up to 24 h after an intravenous or oral administration, suggesting that the assay can be used in pharmacokinetic studies of lurasidone in rats.

  相似文献   

10.
A simple and sensitive liquid chromatographic method was developed for quantification of cefteram in human plasma. Amoxicillin was used as an internal standard. The present method used protein precipitation for extraction of cefteram from human plasma. Separation was carried out on a reversed-phase C18 column. The column effluent was monitored by UV detection at 262 nm. The mobile phase was a mixture of methanol and water containing 0.3% v/v triethylamine and 0.6% v/v glacial acetic acid (35:65:0.3:0.6 v/v) at a flow rate of 0.30 mL min?1. The column temperature was 20 °C. This method was linear over the range of 47.5–4,750.0 ng mL?1 with determination coefficient greater than 0.99. The mean extraction recovery of cefteram and IS was ≥76.82 and ≥76.49%, respectively, and the method was found to be precise, accurate, and specific during the study. The method was successfully applied for a pharmacokinetic study of cefteram in human.  相似文献   

11.
A rapid and simple miniaturized liquid–liquid extraction method has been developed for the determination of topramezone in soil, corn, wheat, and water samples using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-electrospray ionization (ESI)/MS/MS). The established method for the extraction and purification procedure was based on liquid–liquid partitioning into an aqueous solution at a low pH (pH ≈ 2.5), followed by back-partitioning into water at pH > 9. Two precursor, product ion transitions for topramezone were measured and evaluated to provide the maximum degree of confidence in the results. Under negative ESI conditions, quantitation was achieved by monitoring the fragment at m/z = 334 and the qualitative fragment at m/z = 318, whereas also collecting the corresponding parent ion at m/z = 362. Chromatographic separation was achieved using gradient elution with a mobile phase consisting of methanol and a 0.01% aqueous ammonium hydroxide solution. Recovery studies for soil, corn, wheat, and water were conducted at four different topramezone concentrations (5 or 10, 50, 100, and 1,000 μg kg−1); the overall average recoveries ranged from 79.9% to 98.4% with intra-day relative standard deviations (RSD) of 3.1~8.7% and inter-day RSD of 4.3~7.5%. Quantitative results were determined from calibration curves of topramezone standards containing 1–500 μg L−1 with an R 2 ≥ 0.9994. Method sensitivities expressed as limits of quantitation were typically 6, 8, 9, and 1 μg kg−1 in soil, corn, wheat, and water, respectively. The results of the method validation confirmed that this proposed method was convenient and reliable for the determination of topramezone residues in soil, corn, wheat, and water.  相似文献   

12.
A high-performance liquid chromatographic method with triple-quadrupole mass spectrometry detection (LC-MS-MS) was developed and validated for the first time for the simultaneous quantification of zopiclone and its metabolites in rat plasma samples. The analytes were isolated from rat plasma by liquid–liquid extraction and separated using a chiral stationary phase based on an amylose derivative, Chiralpak ADR-H column, and ethanol–methanol–acetonitrile (50:45:5, v/v/v) plus 0.025% diethylamine as the mobile phase, at a flow-rate of 1.0 mL min−1. Moclobemide was used as the internal standard. The developed method was linear over the concentration range of 7.5–500 ng mL−1. The mean absolute recoveries were 74.6 and 75.7; 61.6 and 56.9; 72.5, and 70.7 for zopiclone enantiomers, for N-desmethyl zopiclone enantiomers and for zopiclone-N-oxide enantiomers, respectively, and 75.9 for the internal standard. Precision and accuracy were within acceptable levels of confidence (<15%). The method application in a pilot study of zopiclone kinetic disposition in rats showed that the levels of (+)-(S)-zopiclone were always higher than those of (−)-R-zopiclone. Higher concentrations were also observed for (+)-(S)-N-desmethyl zopiclone and (+)-(S)-N-oxide zopiclone, confirming the stereoselective disposition of zopiclone.  相似文献   

13.
A high-performance liquid chromatography–UV method for determining DCJW concentration in rat plasma was developed. The method described was applied to a pharmacokinetics study of intramuscular injection in rats. The plasma samples were deproteinized with acetonitrile in a one-step extraction. The HPLC assay was carried out using a VP-ODS column and the mobile phase consisting of acetonitrile–water (80:20, v/v) was used at a flow rate of 1.0 mL min−1 for the effective eluting DCJW. The detection of the analyte peak area was achieved by setting a UV detector at 314 nm with no interfering plasma peak. The method was fully validated with the following validation parameters: linearity range 0.06–10 μg mL−1 (r > 0.999); absolute recoveries of DCJW were 97.44–103.46% from rat plasma; limit of quantification, 0.06 μg mL−1 and limit of detection, 0.02 μg mL−1. The method was further used to determine the concentration–time profiles of DCJW in the rat plasma following intramuscular injection of DCJW solution at a dose of 1.2 mg kg−1. Maximum plasma concentration (C max) and area under the plasma concentration–time curve (AUC) for DCJW were 140.20 ng mL−1 and 2405.28 ng h mL−1.  相似文献   

14.
Summary A sensitive and selective high-performance liquid chromatographic method has been developed for monitoring clozapine levels in human plasma. Chromatography was performed on a reversed-phase column (C8, 150 mm×4.6 mm i.d., 5 μm) with acetonitrile-aqueous sodium acetate solution, 88∶12 (v/v), as mobile phase; the flow rate was 1 mL min−1. Clozapine oxidation at +800 mV was detected amperometrically. Response was linearly dependent on concentration over the range 50–1500 ng mL−1 clozapine in plasma. Sample preparation by solid-phase extraction before HPLC analysis gave high extraction yield (94%). The accuracy and precision of the method were both very good (recovery: 97%;RSD<3.3%).  相似文献   

15.
A fast and sensitive high performance liquid chromatography method for quantitative determination of rosiglitazone in human plasma has been developed. The extraction from plasma was performed using solid-phase extraction (SPE) on C4 silica (100 mg) disposable extraction cartridges (DEC). The separation of rosiglitazone and two metabolites was achieved on a Phenomenex® Synergi 4 µm MAX-RP (150 × 4.6 mm) column, protected by a guard column. The mobile phase was 0.01 M ammonium acetate, pH 7.0 - acetonitrile (65:35, v/v). (3S)-3-OH-quinidine was used as internal standard. The analytes were detected using fluorescence detection. The method was validated. The limit of quantitation was 1 ng mL−1 and the detection limit was 0.25 ng mL−1 for rosiglitazone in human plasma. The recovery was 90% for rosiglitazone. Linearity was observed over a range of 1-1000 ng mL−1 (r2=0.9959). The intra- and inter-day precision (C.V.) did not exceed 8.7 %. Applicability of the method was demonstrated by a clinical pharmacokinetic study. A healthy volunteer received in two separate phases 4 mg and 8 mg rosiglitazone maleate as a single oral dose. Plasma concentrations were measured for 24 h in both phases.  相似文献   

16.
To evaluate the pharmacokinetics of a novel analogue of ginkgolide B, 10-O-dimethylaminoethylginkgolide B (XQ-1) in rat plasma in pre-clinical studies, a sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry detection (LC–ESI–MS) was developed and validated. After a simple extraction with ethyl acetate, XQ-1 was analyzed on a Shim-pack C18 column with a mobile phase of a mixture of 1 μmol L−1 ammonium acetate containing 0.02% formic acid and methanol (55:45, v/v) at a flowrate of 0.3 mL min−1. Detection was performed in selected ion monitoring (SIM) mode using target ions at [M + H]+ m/z 496.05 for XQ-1 and m/z 432.10 for the internal standard (lafutidine). Linearity was established for the concentration range from 2 to 1,000 ng mL−1 . The extraction recoveries ranged from 86.0 to 89.9% in plasma at concentrations of 5, 50, and 500 ng mL−1. The lower limit of quantification was 2 ng mL−1 with 100 μL plasma. The validated method was successfully applied to a pharmacokinetic study after intragastic administration of XQ-1 mesylate in rats at a dose of 20 mg kg−1.  相似文献   

17.
A novel and sensitive dispersive liquid–liquid microextraction method based on the solidification of the floating organic drop combined with high‐performance liquid chromatography and ultraviolet detection was used for the determination of atorvastatine in blood serum samples. The chromatographic separation of atorvastatin was carried out using methanol as the mobile phase organic modifier. Various parameters affecting the extraction efficiency were optimized, such as the kind and volume of extraction solvent (1‐undecanol) and disperser solvent (acetonitrile), pH, and the extraction time. The calibration curve was linear in the range of 0.2–6000 μg/L of atorvastatin (r2 = 0.995) with a limit of detection of 0.07 μg/L. The relative standard deviation for 100 μg/L of atorvastatin in human plasma was 8.4% (n = 4). The recoveries of plasma samples spiked with atorvastatin were in the range of 98.8–113.8%. The obtained results showed that the proposed method is fast, simple, and reliable for the determination of very low concentrations of atorvastatin in human plasma samples.  相似文献   

18.
A new high-performance liquid chromatography assay was developed for the determination of minocycline in plasma and brain. A solid–liquid extraction procedure was coupled with a reversed-phase HPLC system. The system requires a mobile phase consisting of acetonitrile:water:perchloric acid (26:74:0.25, v/v/v) adjusted to pH 2.5 with 5 M sodium hydroxide for elution through a RP8 column (250 × 3.0 mm, i.d.) with UV detection set at 350 nm. The method proved to be accurate, precise (RSD < 20%) and linear between 0.15–20 μg mL−1 in plasma and 1–20 μg mg−1 in brain. The method was successfully applied to a blood-brain barrier minocycline transport study.  相似文献   

19.
A selective, sensitive, and accurate high-performance liquid chromatographic method for determination of diltiazem in plasma samples has been developed and validated. The effects of mobile phase composition, buffer concentration, mobile phase pH, and concentration of organic modifiers on retention of diltiazem and internal standard were investigated. Solid-phase and liquid–liquid extraction were examined and proposed for isolation of the drug and elimination of endogenous plasma interferences. A 5 m Lichrocart Lichrospher 60 RP-select B chromatographic column was used; the mobile phase was acetonitrile–0.025 mol L–1 KH2PO4 (pH 5.5), 35:65 ( v / v) at a flow-rate of 1.5 mL min–1. The detection wavelength was 215 nm. The calibration plots were linear in the concentration range 20.0–500.0 ng mL–1. The method has been implemented to monitor diltiazem levels in patient samples.  相似文献   

20.
Xu  Fan  Xu  Guili  Shang  Beicheng  Yu  Fang 《Chromatographia》2009,69(11):1421-1426

A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号