用HCl-HNO3混和酸溶解不锈钢样品,用钇为内标物质,使用标准样品绘制工作曲线,用电感耦合等离子体发射光谱(ICP-OES)法测定了不锈钢中的硅、锰、磷、铬、镍、钼、铜。在选定的操作条件下,对不锈钢标准样品按实验方法进行测定,标准样品的测定值与标准值基本吻合。元素质量分数在0.01%~0.10%时,相对标准偏差(n=11)RSD5%;质量分数大于0.10%,RSD 1%。同时测定不锈钢中的硅、锰、磷、铬、镍、钼、铜元素的含量,操作简单、快速、灵敏度高,结果令人满意。  相似文献   

2.
建立电感耦合等离子体原子发射光谱(ICP–AES)法测定铬镍不锈钢中锰、铬、镍、硅、磷、铜、钼7种元素含量的方法。试样用盐酸与硝酸混合酸溶液溶解,采用溶解国家标准样品的方法制备校准曲线溶液,确定了元素最佳分析谱线。各元素的含量在其测试范围内与原子发射强度呈良好的线性关系,线性相关系数不小于0.999,7种元素的检出限在0.000 3%~0.003 0%之间。该方法应用于铬镍不锈钢标准样品的测定,测定值与认定值相符,测定值的相对标准偏差在0.12%~1.15%之间(n=8)。应用于铬镍不锈钢样品测定时,加标回收率在90%~110%之间。该方法操作简便、迅速,可满足日常铬镍不锈钢中多元素含量的检测需要。  相似文献   

3.
为克服钼铁中元素的偏析,应用了离心浇铸工艺制成蘑菇状的片样供X射线荧光光谱法用,对制样的过程作了详细的叙述.为制作工作曲线用了5个国外内钼铁标准样品及3个内控标准样品,用同一钼铁样品制备6个片样,按试验条件分别进行钼、硅、磷、铜4元素的测定,并对方法的精密度进行了试验,测得相对标准偏差(n=6)在0.24%~5.41%之间.在分析4个钼铁试样时,所得上述4元素的测定值与用化学方法所测得结果一致.  相似文献   

4.
建立电感耦合等离子体发射光谱仪同时测定不锈钢中铬、镍、锰、铜、钛、铝6种元素含量的方法。用20mL王水溶解样品,铬、镍、锰、铜、钛、铝的分析谱线分别为283.563,231.604,259.373,324.754,334.941,308.215 nm。铬、镍、锰、铜、钛、铝的质量浓度与其信号强度均呈良好的线性关系,线性相关系数均不小于0.999,检出限分别为0.007,0.009,0.002,0.007,0.002,0.008μg/mL。测定结果的相对标准偏差为0.17%~2.80%(n=6),加标回收率为96.50%~103.70%。用该法测定国家标准物质,测定值与标准值一致,相对误差为0.05%~3.03%。该方法准确、可靠,可用于不锈钢中铬、镍、锰、铜、钛、铝的测定。  相似文献   

5.
采用硝酸-盐酸-水(1+3+6)混合酸溶液溶解不锈钢样品,用电感耦合等离子体原子发射光谱法同时测定试样溶液中铬、镍、铜、锰、磷、硅、钼和钛等8种合金元素。选择钇元素作为内标元素,选择波长为357.869,231.604,327.396,257.610,178.284,251.611,202.030,337.280 nm8条谱线依次作为铬、镍、铜、锰、磷、硅、钼和钛的分析线。方法用于分析了12种标准物质,测定值同证书值一致,各元素的相对标准偏差(n=7)均小于5.5%。  相似文献   

6.
采集了生长于青海省6个不同地区的枸杞样品150个,并制取分析用样品。每个样品称取约0.5g置于石英管中,加入水1mL和硝酸4mL,按程序进行微波消解,所得溶液在电感耦合等离子体质谱工作条件下测定其中24种微量元素(钾、钠、钙、镁、铁、锌、铜、锰、钴、镍、铅、砷、镉、铬、硒、钼、锑、锶、锡、镨、钆、镝、汞、铽)。用各元素的标准溶液绘制标准曲线。测得各元素的检出限(3s)在0.008~10μg·L-1之间。选用都兰地区的样品进行精密度和回收试验,24种元素测定值的相对标准偏差(n=6)在0.95%~6.6%之间。在回收试验中,称取4份样品,其中1份样品的测定值为本底值,其余3份样品中分别加入3个浓度水平的15种元素的标准溶液,按方法测得各元素的含量,计算得回收率在85.0%~107%之间。运用仪器自带的MPP软件对所有样品所测得的24种元素的分析数据进行主成分分析和聚类分析。结果表明:钠、镁、钙、锰、铁、钴、镍、铜、锌、镉、铅、钼、镨等元素含量在不同个体样品中差异较明显;来自德令哈与格尔木的样品区分度较好;都兰、乌兰和诺木洪的样品散布比较广,样品间的差异不明显;在青海省各地产出的枸杞的24种元素中,钆与镝存在高度相关。  相似文献   

7.
建立了用硝酸-高氯酸消解样品,电感耦合等离子体质谱法(ICP-MS)测定苦荞茶中铜、铅、镉、钴、镍的方法.方法具有灵敏度高、检出限低、精密度好、基体干扰少、准确可靠、快捷、简便的特点.各元素方法检出限(3SD,μg/L)分别为:铜0.009、铅0.023、镉0.015、钴0.022、镍0.035;方法精密度(RSD,n=12)分别为:铜2.5%~3.0%、铅2.1%~2.3%、镉3.0%~3.8%、钴2.5%~2.6%、镍1.5%~1.9%;各元素加标回收率分别为:铜95.0%~105.0%、铅95.0%~105.0%、镉98.0%~105.0%、钴95.0%~105.0%、镍95.0%~105.0%.在线用铑作为内标95.0%~105.0%.方法经国家一级标准物质验证,测定值与标准值吻合.应用于实际样品测定,结果满意.  相似文献   

8.
电感耦合等离子体质谱法测定原油中微量元素   总被引:1,自引:0,他引:1  
原油样品用硝酸和过氧化氢经高压密闭消解罐消解处理,采用电感耦合等离子体质谱法测定其中镁、铝、钒、铬、镍、铜、锌、钼、镉和铅等10种微量元素的含量。10种元素的检出限(3s)在0.012~0.300μg·g~(-1)之间。方法用于S-21油标准样品分析,测定值与认定值相吻合,相对标准偏差(n=5)在0.5%~5.0%之间。10种元素的回收率在93.3%~116.0%之间。  相似文献   

9.
丹参及其近缘种样品用硝酸-高氯酸混合酸(体积比4比1)浸泡过夜,加热消解.在优化的仪器工作条件下,用火焰原子吸收光谱法测定所制得样品溶液中钙、镁、铁、锰、铜和锌的含量,并用石墨炉原子吸收光谱法(GFAAS)测定其中的钼、铅、铬及镉的含量.测定铅及镉时,用磷酸二氢铵作基体改进剂,而测定铬时,用抗坏血酸作基体改进剂.10种元素的检出限(3S/N)均小于0.26μg·g-1,测定钙、镁、铁、锰、铜和锌时,测得其回收率在99.0%~103.6%之间,其相对标准偏差(n=5)在0.54%~1.77%之间;测定钼、铅、铬和镉时,其回收率在100.O%~108.0%之间,相对标准偏差(n=5)在0.02%~1.9%之间.  相似文献   

10.
干净的不锈钢厨具样品(5.0 cm×5.0 cm)用乙酸浸泡24 h后,采用电感耦合等离子体原子发射光谱法(ICP-AES)测定不锈钢厨具中铬、镍、镉、铅,采用氢化物发生-ICP-AES测定其中砷的迁移量。研究了介质的酸度、硼氢化钾浓度对砷信号强度的影响,并考察了其他元素对砷测定的化学干扰。选择波长为267.716,231.604,214.438,220.353,193.695 nm 5条谱线依次作为测定铬、镍、镉、铅和砷的分析线。铬、镍、镉、铅和砷的检出限(3s)分别为0.032,0.026,0.006,0.033,0.007 5 mg.L-1,相对标准偏差(n=10)依次为0.7%,0.8%,3.1%,1.2%,3.6%。应用此法测定样品中5种元素测定值与国标法GB/T 5009.81-2003的测定值相比,两种方法所得结果相一致。  相似文献   

11.
介绍0Cr18Ni10Ti、OCr18Ni12M02Ti、OCr17Ni4Cu4Nb、1Cr25Ni20Si2、1Cr13和2Cr13等6种典型不锈钢和耐热钢系列化学分析用标准物质的成分设计、制备工艺、定值方法及数据处理。采用中频感应炉冶炼.用F方差法检验均匀性,8家实验室采用不同分析方法协同定值。所研制的系列标准物质定值元素多,多数元素含量呈梯度分布,既可单独使用,也可成套使用。  相似文献   

12.
The k0-based internal mono standard instrumental neutron activation analysis (INAA) method was used for the composition analysis of some irregular shape stainless steel (SS) samples of type SS 316M, which is used as fuel cladding in Indian fast breeder test reactor (FBTR). The method utilizes in situ relative detection efficiency using γ-rays of the activation products present in the sample for overcoming γ-ray self-attenuation. Samples were neutron activated using the thermal column as well as the core position of the reactor and the assay of radioactivity was carried out by high-resolution gamma ray spectrometry. The elements determined were Fe, Cr, Ni, Mo, Mn, Co, Cu, As and W. Since all the major elements (Fe, Cr, Ni, Mo and Mn) were amenable to NAA, the relative elemental concentrations with respect to Fe, obtained by this method, were converted to their absolute values by mass balance. The results were compared with specified compositions and found to be satisfactory. In order to validate these results obtained by the standard-less approach, sub samples of SS 316M in solution forms were analyzed by prevalent relative and k0 methods of INAA, and results were found to be in good agreement. The accuracy of the internal mono standard INAA method has been evaluated by analyzing an alloy steel certified reference material, CRM 225/1 of British Chemical Standards (BCS).  相似文献   

13.
不锈钢的 X射线荧光光谱分析   总被引:6,自引:0,他引:6  
用高性能飞利浦PW2400X射线荧光光谱仪,测定不锈钢中Al、Si、P、S、Ti、Cr、Mn、Co、Ni、Cu、As、Mo、Sn、W、Fe15个元素。给出了各元素的干扰校正系数和基体效应校正系数。方法准确、灵敏、稳定性好、速度快。  相似文献   

14.
建立环形聚焦单模微波消解–电感耦合等离子体质谱法同时测定罐头食品中钒、铬、镍、镉、铅、砷、锰、铝、铜、锡金属元素的含量。采用浓硝酸消解样品,各元素分析目标物分别为Pb208,Cd111,As75,Mn55,Cu63,V51,Ni60,Sn120,Cr53,Al27。Pb208以Bi209为内标,Cd111,Sn120以In115为内标,Ni60,Cr53,V51,Mn55,Cu63,As75,Al27以Sc45为内标。各元素工作曲线线性良好,相关系数不小于0.999 5,方法检出限为0.0030~0.030μg/g,加标回收率在98.0%~104.1%之间,测定结果的相对标准偏差为1.29%~4.50%(n=6)。该方法简便快捷,灵敏度高,适合分析大批量罐头食品中多种金属元素。  相似文献   

15.
依据光电发射光谱仪光源激发机理,结合钛合金的材料性能,选用火花放电激励光源和时间分解脉冲分布测光法,绘制钛合金中主要合金元素的工作曲线,对A l、V、Fe、S i、C、Mn、Cu、Mo、Sn、Zr、N i、Cr等元素进行光谱直接测定。测定结果与化学法测定结果基本一致,测定结果的相对标准偏差为0.72%~4.27%(n=11)。  相似文献   

16.
李春盈  张玉英 《分析测试学报》2016,35(12):1634-1638
建立植物类中药材及饮片中铅、镉、总砷、总汞、铜、锑、锡、铬、镍、钡、锰、铊、银、铍、镝、铝、硒、钼共18种重金属及有害元素含量的检测方法和限量。样品经微波消解处理后,采用电感耦合等离子体质谱法(ICP-MS)对100批植物类中药材中的重金属及有害元素进行测定和方法研究。各元素线性关系良好,相关系数(r)均大于0.999 5,方法检出限为0.000 22~0.023 0 mg/kg,回收率为90.2%~108.7%,相对标准偏差为1.8%~4.9%。该方法准确、简便、灵敏,可为植物类中药材中重金属及有害元素的检测与控制提供方法参考。  相似文献   

17.
Liang Q  Jing H  Gregoire DC 《Talanta》2000,51(3):507-513
Proposed is a simple and reliable method for the dissolution of granite and the determination of 38 elements by inductively coupled plasma mass spectrometry. One hundred milligrams of sample are digested with 1 ml of HF and 0.5 ml of HNO(3) in screw top PTFE-lined stainless steel bombs at 190 degrees C for 12 h. Insoluble residues are dissolved using 8 ml of 40% HNO(3) (v/v) heated to 110 degrees C for 3 h. Six granite standard reference materials (GSR-1, JG-2, G-2, NIM-G, SG-3, SG-1a) were studied. Analytical calibration was accomplished using aqueous standard solutions. Rhodium was used as an internal standard to correct for matrix effects and instrument drift. We report data for: Li, Be, Sc, V, Cr, Co, Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, Nb, Mo, Cs, Ba, Hf, Ta, W, Pb, Th, U and 14 of the rare earth elements. The recoveries for most of these elements in granite ranged from 90 to 110%.  相似文献   

18.
Summary A universal method for quantitative analysis of twelve elements in low-alloy steels is described. The samples are digested in a mixture of sulfuric-/nitric acid/ammonium peroxodisulfate. Si, Mn, P, Cu, Al, Ni, Cr, Mo, V, Ti, Co, As are determined in solution by ICP-AES. The procedure was tested with NBS and BCS reference samples. The analytical results are in good agreement with the certified values. With slight modifications, the method is applicable to the analysis of high-alloy steel samples.  相似文献   