首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 491 毫秒
1.
介绍了一种基于数字存储示波器的超声多普勒效应实验系统.该系统利用现有的超声声速测量设备,以频移信号处理电路和数字存储示波器作为数据测量单元的核心,通过与系统底座和运动控制单元相配合,开展与多普勒效应相关的多项综合性、设计性实验.实验中信号的转换、传输和处理过程清晰透明,有利于培养学生的自主动手能力和观察分析问题的能力.该实验系统结构简单,无需复杂的软件编程,各实验室均可自行完成制作,同时又可实现实验资源共享,提高仪器设备的利用率,具有较高的实用和推广价值.  相似文献   

2.
Control of rate and duration of speech movements   总被引:4,自引:0,他引:4  
A computerized pulsed-ultrasound system was used to monitor tongue dorsum movements during the production of consonant-vowel sequences in which speech rate, vowel, and consonant were varied. The kinematics of tongue movement were analyzed by measuring the lowering gesture of the tongue to give estimates of movement amplitude, duration, and maximum velocity. All three subjects in the study showed reliable correlations between the amplitude of the tongue dorsum movement and its maximum velocity. Further, the ratio of the maximum velocity to the extent of the gesture, a kinematic indicator of articulator stiffness, was found to vary inversely with the duration of the movement. This relationship held both within individual conditions and across all conditions in the study such that a single function was able to accommodate a large proportion of the variance due to changes in movement duration. As similar findings have been obtained both for abduction and adduction gestures of the vocal folds and for rapid voluntary limb movements, the data suggest that a wide range of changes in the duration of individual movements might all have a similar origin. The control of movement rate and duration through the specification of biomechanical characteristics of speech articulators is discussed.  相似文献   

3.
Previous work has shown that the lips are moving at a high velocity when the oral closure occurs for bilabial stop consonants, resulting in tissue compression and mechanical interactions between the lips. The present experiment recorded tongue movements in four subjects during the production of velar and alveolar stop consonants to examine kinematic events before, during, and after the stop closure. The results show that, similar to the lips, the tongue is often moving at a high velocity at the onset of closure. The tongue movements were more complex, with both horizontal and vertical components. Movement velocity at closure and release were influenced by both the preceding and the following vowel. During the period of oral closure, the tongue moved through a trajectory of usually less than 1 cm; again, the magnitude of the movement was context dependent. Overall, the tongue moved in forward-backward curved paths. The results are compatible with the idea that the tongue is free to move during the closure as long as an airtight seal is maintained. A new interpretation of the curved movement paths of the tongue in speech is also proposed. This interpretation is based on the principle of cost minimization that has been successfully applied in the study of hand movements in reaching.  相似文献   

4.
This study used glossometry to examine the position of the tongue and the velocity of its movements in vowels spoken normally and at a self-selected fast rate. The subject in experiment 1 showed lingual undershoot for stressed vowels in "a big again" and "a bob again." The tongue was lower for /I/ and higher for /a/ at the fast rate than at the normal rate. The stressed vowels exerted an affect on unstressed vowels: The tongue was lower in the schwas that preceded and followed /a/ than /I/. Only one of the three subjects in experiment 2 showed no lingual undershoot for fast-rate /I/. The tongue was higher at the fast rate than at the normal rate in the schwas flanking /I/ so that the displacement was less at the fast rate than at the normal rate. Another talker increased the peak velocity of tongue movements at the fast rate and showed no undershoot for /a/. Multiple regression analyses showed that the timing of movements for successive phonetic segments accounted well for undershoot in only one of the three subjects. The results suggest that in order to model the effects of speaking rate on the tongue movements used in forming stressed vowels, it will be necessary to take into account: (1) how much vowels are shortened at a fast rate: (2) how much the peak velocity of tongue movements is increased, if at all; and (3) the position of the tongue before and after the stressed vowels. All three factors are likely to be influenced by how clearly the talker wishes to speak.  相似文献   

5.
We have developed a fetal movement monitoring system based on small displacement measurement of internal tissues. When ultrasonic pulses are transmitted to the fetus, the reflected ultrasonic waves which have a Doppler frequency shift due to the fetal movements are detected by using an ultrasonic pulsed Doppler technique. In this paper, we propose a displacement measurement method for internal tissues which is based on the Doppler signal digital detection technique. In the method, the received ultrasonic RF signals are sampled with a sampling frequency of four times higher than the centre frequency of the ultrasonic waves; the Doppler frequency shift signals are derived using digital signal processing. From the detected signals, the internal displacements are estimated using the arc-tangent method. The basic algorithm of the detection method has already been used in the area of blood flow sensing, however, we apply the algorithm to the displacement measurement of internal tissues. The comparison between the proposed method and the conventional method is presented. The fetal movement quantitative monitoring system based on the method which has been constructed is shown.  相似文献   

6.
In a radar system, it is necessary to measure both range and velocity of a target. The movement of the target causes a Doppler shift of the radar signal, and the size of the Doppler shift is used to measure the velocity of the target. In this work, a chaotic drive-response system is simulated that detects a Doppler shift in a chaotic signal. The response system can detect Doppler shifts in more than one signal at a time.  相似文献   

7.
超声动态向量血流成像的产品化实现   总被引:1,自引:1,他引:0  
传统超声彩色多普勒成像测量的是血流沿超声传播方向上的速度分量,故无法得到垂直于超声传播方向的血流。向量血流成像是一种更加先进的超声血流成像技术。它不受角度限制,可以直接计算出血流速度的大小和方向。本文总结了现有多种超声向量血流成像技术的特点和发展情况,并从产品化实现的角度分析了各项技术的优缺点。从超声系统发射接收、血流成像、向量速度方向合成、显示等几个方面详述了迈瑞超声向量血流成像技术产品化实现过程中遇到的主要问题及解决方案。实验采用了中科院声学所研制的超声多普勒仿血流体模,通过向量血流成像和脉冲多普勒成像分别测量体模的仿血流速度。将向量血流成像直接计算出来的速度值与脉冲多普勒经过角度校正得到的速度进行对比。在不同条件下,经过多次测量,二者的平均相对误差均在10%以内。  相似文献   

8.
This study was designed to test the hypothesis that the kinematic manipulations used by speakers in different speaking conditions are influenced by kinematic performance limits. A range of kinematic parameter values was elicited by having seven subjects produce cyclical CV movements of lips, tongue blade and tongue dorsum (/ba/, /da/, /ga/), at rates ranging from 1 to 6 Hz. The resulting measures were used to establish speaker- and articulator-specific kinematic performance spaces, defined by movement duration, displacement and peak speed. These data were compared with speech movement data produced by the subjects in several different speaking conditions in the companion study (Perkell et al., 2002). The amount of overlap of the speech data and cyclical data varied across speakers, from almost no overlap to complete overlap. Generally, for a given movement duration, speech movements were larger than cyclical movements, indicating that the speech movements were faster and were produced with greater effort, according to the performance space analysis. It was hypothesized that the cyclical movements of the tongue and lips were slower than the speech movements because they were more constrained by (coupled to) the relatively massive mandible. To test this hypothesis, a comparison was made of cyclical movements in maxillary versus mandibular frames of reference. The results indicate that the cyclical movements were not strongly constrained by mandible movements. The overall results generally indicate that the cyclical task did not succeed in defining the upper limits of kinematic performance spaces within which the speech data were confined. Thus, the hypothesis that performance limits influence speech kinematics could not be tested effectively. The differences between the speech and cyclical movements may be due to other factors, such as differences in speakers' "skill" with the two types of movement, or the size of the movements--the speech movements were larger, probably because of a well-defined target for the primary, stressed vowel.  相似文献   

9.
This study examined the temporal phasing of tongue and lip movements in vowel-consonant-vowel sequences where the consonant is a bilabial stop consonant /p, b/ and the vowels one of /i, a, u/; only asymmetrical vowel contexts were included in the analysis. Four subjects participated. Articulatory movements were recorded using a magnetometer system. The onset of the tongue movement from the first to the second vowel almost always occurred before the oral closure. Most of the tongue movement trajectory from the first to the second vowel took place during the oral closure for the stop. For all subjects, the onset of the tongue movement occurred earlier with respect to the onset of the lip closing movement as the tongue movement trajectory increased. The influence of consonant voicing and vowel context on interarticulator timing and tongue movement kinematics varied across subjects. Overall, the results are compatible with the hypothesis that there is a temporal window before the oral closure for the stop during which the tongue movement can start. A very early onset of the tongue movement relative to the stop closure together with an extensive movement before the closure would most likely produce an extra vowel sound before the closure.  相似文献   

10.
刘志勇  滕达  项延训 《应用声学》2021,40(6):856-864
超声相控阵是超声检测领域常用的材料缺陷定位和成像技术,可便捷快速地对裂纹、孔洞等缺陷进行成像。但是,传统超声相控阵方法对较小缺陷如闭合裂纹不太敏感。非线性超声信号因对材料性能退化以及微小缺陷敏感而广受关注。本文针对疲劳闭合裂纹检测,提出一种基于幅度调制的非线性超声相控阵成像方法,通过测量物理聚焦和虚拟聚焦两种聚焦模式下超声扩散场中的声能差,并将其作为非线性参量,实现疲劳裂纹闭合部分的定位成像和定量表征。将该法应用于7075铝合金试样疲劳裂纹的实验测量,并研究了扩散场信号延迟时间对非线性超声相控阵成像结果的影响。结果表明:相较于传统超声相控阵全聚焦法,基于幅度调制的非线性超声相控阵成像方法能够更准确地定位和成像疲劳裂纹闭合部分;延迟时间的选择对疲劳裂纹长度的表征精度影响较大,本文研究了该延迟时间的选择方法并实现了检测结果的优化。  相似文献   

11.
This paper examines tongue movements in stop and fricative consonants where the duration of the oral closure/constriction for the consonant is varied for linguistic purposes. Native speakers of Japanese served as subjects. The linguistic material consisted of Japanese word pairs that only differed in the duration of the lingual consonant, which was either long or short. Recordings were made of tongue movements using a magnetometer system. Results show a robust difference in closure duration between the long and short consonants. Overall, the path of the tongue movement during the consonant was longer for the long than for the short consonant. All speakers decreased the speed of the tongue movement during the long consonant. These adjustments in tongue movements were most likely made to maintain the contact between the tongue and the palate for the closure and constriction.  相似文献   

12.
针对现有的声多普勒效应实验装置中存在的问题,设计并制作了摆动式声多普勒效应实验仪.该仪器能够分别进行声源运动和观察者运动的声多普勒效应实验,且可定量分析频偏和测量速度.本文详细介绍了该仪器的原理、构造、特点和实验过程,并对实验结果进行了较为全面的分析.  相似文献   

13.
准确的脑血流成像对脑功能监测和脑疾病的快速诊断具有重要意义,然而颅骨对超声传播的影响会导致成像质量下降、速度或位移估计不准确等问题.论文采用平面波相干复合结合散斑跟踪方法进行颅内散射目标成像和速度估计,以实现脑血流速度矢量检测;针对颅骨存在导致的超声相位畸变,利用数值仿真和体模实验研究了其对成像及散斑跟踪效果的影响,并...  相似文献   

14.
皮棉杂质透射检测及成像目标增强方法   总被引:2,自引:0,他引:2       下载免费PDF全文
郏东耀  丁天怀 《物理学报》2005,54(9):4058-4064
由于皮棉中白色或无色的杂质与皮棉反射特性相似,现有的光谱反射成像检测方法具有一定 的局限性.对皮棉杂质的光透射成像检测方法进行深入研究.在分析杂质及棉纤维透射特性基 础上,建立了光透射成像机理模型.研究了光透射成像系统中光源种类、光源能量、棉层厚 度及皮棉运动速度对成像目标的影响.根据棉层中透射光子的传播特性,提出利用高速CCD俘 获非漫射光子及统计滤波处理方法以增强成像目标,并分析了高速CCD曝光时间与成像目标 清晰度的量化关系.结果表明,所提出的光透射检测及成像目标增强方法,可获得清晰的目 标图像特征,检测结果与实际相符,此方法不仅为检测皮棉中各种白色或无色杂质提供一种 有效途径, 而且还可推广到红外及其他波段的成像系统中,对于微弱目标的透射成像检测 提供一种新的思路. 关键词: 皮棉杂质 透射成像 准直线光子 目标增强 统计滤波  相似文献   

15.
除垢超声波传播影响因素的理论研究   总被引:1,自引:0,他引:1  
从一维平面波理论入手分析了超声波声压分布特性。依据多普勒频移原理,在声场的运动方程,连续性方程,波动方程的基础上,建立一个超声波在流动的液体中传播的控制方程。根据轴对称模型的实际特点,简化了所得方程,并求出解析解。结果表明流动液体可以产生声波的衰减。液体的黏滞性是产生超声波衰减的重要原因。超声波的频率较高,液体的黏滞性对超声波衰减影响明显。依据黏滞力与速度梯度的关系,建立一个超声波在黏滞液体传播的控制方程,并依据边界条件求出解析解,反映了媒质黏滞性对超声波传播尤其是衰减特性的影响。  相似文献   

16.
肌肉组织受力时的弹性特征变化,是其功能特性、健康状态的重要评估参量.该文利用在离体肌肉组织表面施加低频振动引起组织发生形变,在组织内部产生剪切波的方法,经过快速超声成像,通过剪切波图像估计剪切波的传播速度.研究结果表明顺肌纤维方向传播的剪切波速度快于垂直肌纤维方向传播的剪切波速度,剪切波的传播速度随受力的增加而变大,且...  相似文献   

17.
Hirata S  Kurosawa MK 《Ultrasonics》2012,52(7):873-879
Real-time distance measurement of a moving object with high accuracy and high resolution using an ultrasonic wave is difficult due to the influence of the Doppler effect or the limit of the calculation cost of signal processing. An over-sampling signal processing method using a pair of LPM signals has been proposed for ultrasonic distance and velocity measurement of moving objects with high accuracy and high resolution. The proposed method consists of cross correlation by single-bit signal processing, high-resolution Doppler velocity estimation with wide measurement range and low-calculation-cost Doppler-shift compensation. The over-sampling cross-correlation function is obtained from cross correlation by single-bit signal processing with low calculation cost. The Doppler velocity and distance of the object are determined from the peak interval and peak form in the cross-correlation function by the proposed method of Doppler velocity estimation and Doppler-shift compensation. In this paper, the proposed method of Doppler-shift compensation is improved. Accuracy of the determined distance was improved from approximately within ±140 μm in the previous method to approximately within ±10 μm in computer simulations. Then, the proposed method of Doppler velocity estimation is evaluated. In computer simulations, accuracy of the determined Doppler velocity and distance were demonstrated within ±8.471 mm/s and ±13.87 μm. In experiments, Doppler velocities of the motorized stage could be determined within ±27.9 mm/s.  相似文献   

18.
We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.  相似文献   

19.
This paper examines tongue movements between the two vowels in sequences of vowel-labial consonant-vowel, addressing the question whether the movement is a straight line or a curved path. Native speakers of Japanese and Italian served as subjects. The linguistic material consisted of words where the bilabial consonant was either long or short. The inclusion of words with different consonant lengths was motivated by earlier findings that the tongue movement is often longer when the consonant is long, which may be due to a more curved movement path. Tongue movements were recorded using a three-transmitter magnetometer system. To assess the movement path, the movement magnitude was calculated in two ways, as a straight line, the Euclidean distance, and as the actual path, obtained by summing the individual Euclidean distances between successive samples from movement onset to offset. The ratio between the path and the Euclidean distance is 1 when the movement is a straight line and greater than 1 when the path is curved. Results show that in virtually all 21 cases examined the ratio was very close to 1 and in most cases 1.2 or less. There was no reliable influence of consonant length on the ratio.  相似文献   

20.
We describe a novel optical system for bidirectional color Doppler imaging of flow in biological tissues with micrometer-scale resolution and demonstrate its use for in vivo imaging of blood flow in an animal model. Our technique, color Doppler optical coherence tomography (CDOCT), performs spatially localized optical Doppler velocimetry by use of scanning low-coherence interferometry. CDOCT is an extension of optical coherence tomography (OCT), employing coherent signal-acquisition electronics and joint time-frequency analysis algorithms to perform flow imaging simultaneous with conventional OCT imaging. Cross-sectional maps of blood flow velocity with <50-microm spatial resolution and <0.6-mm/s velocity precision were obtained through intact skin in living hamster subdermal tissue. This technology has several potential medical applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号