首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
2,5‐Dihydroxybenzoic acid (DHB) is one of the most widely used and studied matrix compounds in matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. However, the influence of ageing of the DHB solution on the MALDI mass spectra has not been yet systematically studied. In this work, the possible changes occurring in the acidified acetonitrile/water solution of the MALDI matrix compound DHB during 1‐year usage period have been monitored with MALDI‐Fourier transform ion cyclotron resonance mass spectrometer (MALDI‐FT‐ICR‐MS) and attenuated total reflectance Fourier transform infrared (ATR‐FT‐IR) spectroscopy. No significant ageing products have been detected. The ability of the aged DHB solution to act as a MALDI matrix was tested with two materials widely used in art and conservation – bone glue (a proteinaceous material) and shellac resin (a resinous material) – and good results were obtained. A number of peaks in the mass spectra measured from the DHB solution were identified, which can be used for internal calibration of the mass axis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
Some time ago, we published an announcement that the azo group that closes model cyclic peptides is often reduced in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) in the presence of 2,5-dihydroxybenzoic acid (2,5-DHB) as the matrix. In this work, we demonstrate that these peptides are ionized in all DHB matrix isomers, although threshold ionization laser energies as well as the reduction ratios differ in each matrix. Using a NALDI plate, we confirmed that their reduction depends on the presence of DHB matrix and that the hydrogen atoms participating in the reaction come from the DHB matrix hydroxyl group. We show that the reduction ratio is affected by the overall covalent structure of the peptide, by the presence of a free carboxyl group in DHB matrix, by the mutual position of the hydroxyl and carboxyl groups, as well as the laser beam intensity. Based on these results, it can be concluded that the azo-group reduction in cyclic peptides is a very complex process and we are far from fully understanding its nature. We hope that our experimental results will help to shed some light on the MALDI process that still remains mysterious in some of its aspects.  相似文献   

3.
Utilizing synchronized dual-polarity matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, we found good evidence of the incoherent production of positive and negative matrix ions. Using thin, homogeneous 2,5-dehydroxybenzoic acid (DHB) matrix films, positive and negative matrix ions were found to appear at different threshold laser fluences. The presence of molecular matrix ions of single charge polarity suggests that the existence of DHB ion-pairs may not be a prerequisite in MALDI. Photoelectrons induced by the laser excitation may assist the production of negative DHB ions, as shown in experiments conducted with stainless steel and glass substrates. At high laser fluences, the relative yield of positive and negative matrix ions remained constant when homogeneous matrix films were used, but it fluctuated significantly with inhomogeneous crystal morphology. This result is also inconsistent with the hypothesis that matrix ion-pairs are essential primary ions. Evidence from both low and high laser fluences suggests that the productions of positive and negative matrix ions in MALDI may occur via independent pathways.  相似文献   

4.
Tong H  Sze N  Thomson B  Nacson S  Pawliszyn J 《The Analyst》2002,127(9):1207-1210
Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.  相似文献   

5.
A specially constructed split sample probe was used to unequivocally demonstrate that gas-phase cationization occurs within the desorption plume during a matrix-assisted laser desorption/ionization experiment. Two separate samples were prepared for analysis: on side A, a mixture of poly(ethylene glycol) (PEG) 1500 analyte and 2,5-dihydroxybenzoic acid (DHB) matrix, and on side B a mixture of DHB matrix and lithium hydroxide (LiOH), the cationization reagent. Analysis of the data showed that when the ionization laser was focused on the split (so that both sides were illuminated), Li(+)-cationized PEG peaks were observed. Since the PEG analyte did not come into contact with Li(+) in either the solution or solid phase, the only possibility for the observed cationization was a reaction in the gas phase. Due to the difficulty in completely removing the adventitious cations (Na(+) and K(+)) present in DHB and on sample surfaces, gas-phase cationization could not be demonstrated to be either the only or most important mechanism operating in the MALDI experiment.  相似文献   

6.
Hydrophobic compounds with hydroxyl, aldehyde or ketone groups are generally difficult to detect using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), because these compounds have low proton affinity and are poorly ionized by MALDI. Herein, coumarins have been used as new matrices for MALDI-MS analysis of a variety of hydrophobic compounds with low ionization efficiency, including steroids, coenzyme Q10, a cyclic lipopeptide and cholesterol oleate. Five coumarins, including coumarin, umbelliferone, esculetin, 7-hydroxycoumarin-3-carboxylic acid (HCA) and 6,7-dihydroxycoumarin-3-carboxylic acid (DCA), were compared with the conventional matrices of 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (CHCA). Coumarins with hydroxyl or carboxylic acid groups enabled detection. Taking DCA as an example, this matrix proved to be superior to DHB or CHCA in detection sensitivity, stability, spot-to-spot and sample-to-sample reproducibility, and accuracy. DCA increased the stability of the target compounds and decreased the loss of water. The [M + Na]+ peaks were observed for all target compounds by adding NaCl as an additive, and the [M − H2O + H]+ and [M + H]+ peaks decreased. DCA was selected for the identification of sterols in yeast cells, and thirteen sterols were detected by Fourier transform ion cyclotron resonance (FT ICR) mass spectrometry. This work demonstrates the potential of DCA as a new matrix for detection of hydrophobic molecules by MALDI-MS and provides an alternative tool for screening sterols in antifungal research.  相似文献   

7.
A robust and sensitive sample preparation method is presented for matrix-assisted laser desorption ionization (MALDI) mass spectrometric analysis of low nanomolar concentrations of proteins containing high amounts of common salts and buffers. This method involves the production of densely packed sub-micrometer matrix crystals by depositing a matrix solution on top of a matrix seed-layer prepared on a MALDI target. A sub-microliter aliquot of analyte solution is then directly added to the top of the matrix crystals to form a thin-layer. alpha-Cyano-4-hydroxycinnamic acid (4-HCCA) is used as matrix and demonstrated to give better performance than other commonly used matrices, such as 2,5-dihydroxybenzoic acid (DHB), 2-(4-hydroxy-phenylazo) benzoic acid (HABA), or sinapinic acid. This three-layer method is shown to be superior to the other MALDI sample preparation methods, particularly for handling low nanomolar protein solutions containing salts and buffers.  相似文献   

8.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) is an excellent analytical technique for rapid analysis of a variety of molecules with straightforward sample pretreatment. The performance of MALDI‐TOF MS is largely dependent on matrix type, and the development of novel MALDI matrices has aroused wide interest. Herein, we devoted to seek more robust MALDI matrix for herbal saponins than previous reported, and ginsenoside Rb1, Re, and notoginsenoside R1 were used as model saponins. At the beginning of the present study, 2,5‐dihydroxybenzoic acid (DHB) was found to provide the highest intensity for saponins in four conventional MALDI matrices, yet the heterogeneous cocrystallization of DHB with analytes made signal acquisition somewhat “hit and miss.” Then, graphene oxide (GO) was proposed as an auxiliary matrix to improve the uniformity of DHB crystallization due to its monolayer structure and good dispersion, which could result in much better shot‐to‐shot and spot‐to‐spot reproducibility of saponin analysis. The satisfactory precision further demonstrated that minute quantities of GO (0.1 μg/spot) could greatly reduce the risk of instrument contamination caused by GO detachment from the MALDI target plate under vacuum. More importantly, the sensitivity and linearity of the standard curve for saponins were improved markedly by DHB‐GO composite matrix. Finally, the application of detecting the Rb1 in complex biological sample was exploited in rat plasma and proved it applicable for pharmacokinetic study quickly. This work not only opens a new field for applications of DHB‐GO in herbal saponin analysis but also offers new ideas for the development of composite matrices to improve MALDI MS performance.  相似文献   

9.
Direct two-photon ionization of the matrix has been considered a likely primary ionization mechanism in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. This mechanism requires that the vertical ionization threshold of matrix materials be below twice the laser photon energy. Because dimers and larger aggregates may be numerous in the early stages of the MALDI plume expansion, their ionization thresholds are important as well. We have used two-color two-photon ionization to determine the ionization thresholds of jet cooled clusters of an important matrix, 2,5-dihydroxy benzoic acid (DHB), and mixed clusters with the thermal decomposition product of DHB, hydroquinone. The thresholds of the clusters were reduced by only a few tenths of an eV compared to the monomers, to an apparent limit of 7.82 eV for pure DHB clusters. None of the investigated clusters can be directly ionized by two nitrogen laser photons (7.36 eV), and the ionization efficiency at the thresholds is low.  相似文献   

10.
A simple reversed-phase nano-column purification and sample preparation technique is described, which markedly improves the mass spectrometric analysis of complex and contaminated peptide mixtures by matrix-assisted laser desorption/ionization (MALDI). The method is simple, fast and utilizes only low-cost disposables. After loading the sample on the column and a subsequent washing step, the analyte molecules are eluted with 50-100 nl of matrix solution directly on to the MALDI/MS target. The washing step ensures removal of a wide range of contaminants. The small bed volume of the column allows efficient sample concentration and the elution process yields very small sample spots. This simplifies the analysis and minimizes discrimination effects due to sample heterogeneity, because the desorption/ionization laser simultaneously irradiates a large portion of the sample. Taken together, these features of the method significantly improve the sensitivity for MALDI/MS analysis of contaminated peptide samples compared with the commonly used sample preparation procedures. This is demonstrated with in-gel tryptic digests of proteins from human brain that were separated by 2D gel electrophoresis. Furthermore, it is shown that with this method 2,5-dihydroxybenzoic acid (DHB) acts as an efficient matrix for peptide mapping. Both detection sensitivity and sequence coverage are comparable to those obtained with the currently preferred matrix alpha-cyano-4-hydroxycinnamic acid (CHCA). The higher stability of peptide ions generated with DHB compared with CHCA is advantageous when analyzing fragile sample molecules. Therefore, the method described here is also of interest for the use of Fourier transform ion cyclotron resonance (FT-ICR) or ion-trap mass analyzers.  相似文献   

11.
In this study we report an improved protocol that combines simplified sample preparation and micro-scale separation for mass spectrometric analysis of neuropeptides from individual neuroendocrine organs of crab Cancer borealis. A simple, one-step extraction method with commonly used matrix-assisted laser desorption/ionization (MALDI) matrix, 2,5-dihydroxybenzoic acid (DHB), in saturated aqueous solution, is employed for improved extraction of neuropeptides. Furthermore, a novel use of DHB as background electrolyte for capillary electrophoresis (CE) separation in the off-line coupling of CE to MALDI-Fourier transform mass spectrometric (FT-MS) detection is also explored. The new CE electrolyte exhibits full compatibility with MALDI-MS analysis of neuropeptides in that both the peptide extraction process and MALDI detection utilize DHB. In addition, enhanced resolving power and improved sensitivity are also observed for CE-MALDI-MS of peptide mixture analysis. Collectively, the use of DHB has simplified the extraction and reduced the sample loss by elimination of homogenizing, drying, and desalting processes. In the mean time, the concurrent use of DHB as CE separation buffer and subsequent MALDI matrix offers improved spectral quality by eliminating the interferences from typical CE electrolyte in MALDI detection.  相似文献   

12.
A novel quadrupole ion trap mass spectrometer laser microprobe instrument with an external ionization source was constructed and used to investigate the matrix-assisted laser desorption/ionization (MALDI) detection of pharmaceutical compounds in intact tissue. In addition to MALDI, laser desorption coupled with chemical ionization (LD/CI) was investigated. MALDI, using 2,5-dihydroxybenezoic acid (DHB) as a matrix, was employed to detect the anticancer drug paclitaxel from a thin section of rat liver tissue which had been incubated in a solution of paclitaxel. The results of that experiment showed that the ability to perform tandem mass spectrometry (MS/MS) with the quadrupole ion trap was crucial in the identification of drug compounds at trace levels in the complex tissue matrix. MALDI MS/MS was then used to detect the presence of paclitaxel in a human ovarian tumor at a concentration of approximately 50 mg/kg. Finally, the drug spiperone was detected in incubated rat liver tissue at an approximate level of 25 mg/kg using LD/CI (no MALDI matrix). Again, the MS/MS capability of the quadrupole ion trap was crucial in the identification of the drug at trace levels in the complex tissue matrix.  相似文献   

13.
For matrix‐assisted laser desorption/ionization (MALDI) mass spectra, undesirable ion contamination can occur due to the direct laser excitation of substrate materials (i.e., laser desorption/ionization (LDI)) if the samples do not completely cover the substrate surfaces. In this study, comparison is made of LDI processes on substrates of indium and silver, which easily emit their own ions upon laser irradiation, and conventional materials, stainless steel and gold. A simultaneous decrease of ion intensities with the number of laser pulses is observed as a common feature. By the application of an indium substrate to the MALDI mass spectrometry of alkali salts and alkylammonium salts mixed with matrices, 2,5‐dihydroxybenzoic acid (DHB) or N‐(4‐methoxybenzylidene)‐4‐butylaniline (MBBA), the mixing of LDI processes can be detected by the presence of indium ions in the mass spectra. This method has also been found to be useful for investigating the intrinsic properties of the MALDI matrices: DHB samples show an increase in the abundance of fragment ions of matrix molecules and cesium ions with the number of laser pulses irradiating the same sample spot; MBBA samples reveal a decrease in the level of background noise with an increase in the thickness of the sample layer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS), utilizing an on-probe sample pretreatment, was applied to the rapid and direct detection of intact phospholipids from whole bacterial cells. The sample preparation procedure involved depositing growing bacterial colonies from culture dishes directly onto the MALDI probe followed by treatment of the sample spot with a 3 micro L aliquot of an aqueous 0.05 M solution of sodium iodide prior to the addition of a 2,5-dihydroxybenzoic acid (DHB) matrix solution (ca. 8 mg dissolved in 70% acetonitrile/30% H(2)O containing 0.1% of trifluoroacetic acid). The MALDI spectra obtained from whole bacteria cells showed a series of ions generated from bacterial phospholipids, such as phosphatidylethanol-amines (PEs) and phosphatidylglycerols (PGs), which were clearly observed as well-resolved peaks. The ranges of the observed total carbon numbers in two acyl groups for PEs and PGs (30-36 and 33-36, respectively) were in good agreement with those reported previously. Furthermore, the distinct discrimination of four species of the Enterobacteriaceae family cultured identically was achieved by using principal components analysis (PCA) conducted on the relative peak intensities of phospholipids observed from the MALDI spectra.  相似文献   

15.
The behaviour of 2,5‐dihydroxybenzoic acid (2,5‐DHB) matrix under matrix‐assisted laser desorption/ionisation (MALDI) conditions was investigated, and the formation of 2,5‐DHB cluster ions, mainly dehydrated 2,5‐DHB ions, is reported. Interestingly, in the mass spectra of this compound, besides dimers and trimers, protonated tetramers, pentamers, hexamers and heptamers were also found with significant abundance. The MALDI behaviour of four flavonoids, quercetin, myricetin, luteolin and kaempferol, using 2,5‐DHB as matrix, was also investigated. The mass spectra of the flavonoids studied revealed a number of flavonoid–2,5‐DHB cluster ions (mainly with the dehydrated 2,5‐DHB). The number of clusters formed is dependent on the structure of the analyte. For luteolin and kaempferol, in particular, evidence was found for the formation of cluster ions involving retro Diels Alder fragments and intact flavonoids molecules, as well as the corresponding protonated retro Diels Alder fragments with dehydrated DHB molecules. All ion compositions were attributed taking into account high accuracy mass measurements and tandem mass spectrometry experiments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Three different types of fullerene derivatives, namely methano[60]fullerene dicarboxylate esters, [60]fulleropyrrolidines, and imino[60]fullerenes, were analyzed by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry using trans‐4‐tert‐butyl‐4′‐nitrostilbene (TBNS), 1,8,9‐anthracenetriol (dithranol), 6‐aza‐2‐thiothymine (ATT), 2,5‐dihydroxybenzoic acid (DHB) and carbazole as matrices. Unit mass resolution (sufficient to clearly resolve isotopic peaks), high signal‐to‐noise ratio, and clean mass spectra for all analytes were acquired by the optimization of experimental parameters and choice of optimal solvent for the matrix and molar matrix‐to‐analyte ratio. The new matrix, TBNS, gave the best results in the positive‐ion mode, as it can provide higher yields of analyte molecular ions at a lower laser threshold than the other four matrices, together with a very low degree of unwanted fragmentations. In the negative‐ion mode dithranol was better than TBNS, and the other three matrices gave relatively poor mass spectra for these fullerene derivatives. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

17.
Fragmentation of different generations of poly(amidoamine) dendrimers was explored in five common MALDI matrices: 2,5-dihydroxybenzoic acid (DHB), 4-hydroxy-3-methoxycinnamic acid (FER), α-cyano-4-hydroxycinnamic acid (ACH), 2,4,6-trihydroxyacetophenone (THAP), and 3-hydroxypicolinic acid (HPA). Of these, DHB was the softest matrix and ACH produced significant fragment intensity already at MALDI threshold, FER and THAP being in between. HPA was not a convenient matrix for dendrimers and produced a specific fragmentation pattern. Fragmentation analysis was mainly concentrated on generation G1, which contains already all essential structural elements. Dendrimers showed complicated fragmentation behavior with multiple fragmentation channels in our MALDI experiments. The relative intensities of these channels depended selectively on choice of the matrix and showed dissimilar dependence on the laser pulse energy. This was attributed to different fragmentation mechanisms, due to different protonation pathways, occurring in the same MALDI plume. The fragmentation pathways were proposed for all observed fragmentation channels. All fragmentation sites of protonated ions were found to be directly attached to the protonation sites and the fragmentation was surplus charge driven in this sense. No charge remote fragmentation channels were detected. Cationized dendrimers showed higher stability than the protonated ions.  相似文献   

18.
Four C3-symmetrical tris(dipeptide) disks and their precursors were characterized using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). The C3-symmetrical disks were based on a benzene-1,3,5-triscarboxamide core extended by oligopeptides with trialkoxyanilide tails. The results indicate that MALDI TOF MS is a powerful and straightforward analytical technique for characterizing C3-symmetrical disks and their precursors. Clear (pseudo)-molecular ion peaks could readily be identified. It is remarkable that strong radical ion signals were observed for all the compounds, including the anilines that were expected to be protonated prior to laser irradiation using acidic MALDI matrixes. Possible mechanisms for radical ion formation were investigated with the employment of radical scavengers, with various matrixes and with direct laser desorption/ionization (LDI). Most likely the radicals are formed by losing one electron from the aniline nitrogen and stabilized by conjugation through the phenyl ring. It appears that direct photo/thermal ionization of analytes is an important route for the radical ion formation of the compounds with trialkoxy aniline/anilide groups.  相似文献   

19.
The use of a novel 2,5-dihydroxybenzoic acid/N,N-dimethylaniline (DHB/DMA) matrix-assisted laser desorption/ionization (MALDI) matrix for detection and quantitative analysis of native N-linked oligosaccharides was investigated in this study. Substantial improvements in sensitivity were observed relative to the signals obtained with a traditional DHB matrix. Moreover, the morphology of the matrix crystal layer was very uniform, unlike that of DHB. This resulted in highly homogeneous sample distribution throughout the spot, allowing reproducible and consistent mass spectra to be obtained without spot-to-spot variations in signal. Here, we also demonstrate an approach for performing sensitive and accurate quantitative analysis of native N-linked glycans with this novel matrix using an internal standard method.  相似文献   

20.
High‐resolution matrix‐assisted laser desorption/ionization (MALDI) time‐of‐flight mass spectrometry (TOF MS) was used for the analysis of the low‐molecular‐weight products from the photo‐oxidation of poly(3‐hexylthiophene) (P3HT) in solution and thin film. Eight new peak series were observed in the low‐mass range of the mass spectra of the products degraded in solution, and the formulas of the eight components were determined from the accurate mass. From SEC/MALDI‐TOF MS, two components were identified as the degraded products, and the other six components were derived from the fragmentation of the degraded products during the MALDI process. A mechanism for the formation of these components was proposed on the basis of the results of MALDI‐TOF MS. For the thin film degradation, a part of products in the solution degradation were observed, which supports that the oxidation of P3HT in solution and thin film proceeded in the same mechanism. This study shows that high‐resolution MALDI‐TOF MS is effective for the analysis of the low‐molecular‐weight products from P3HT photo‐oxidation and expected to be feasible for the degradation analyses of other polymers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号