首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel technique enabling selective bead trapping in microfluidic devices without the use of physical barriers is presented in this paper. It is a fast, convenient and simple method, involving microcontact printing and self-assembly, that can be applied to silicon, quartz or plastic substrates. In the first step, channels are etched in the substrate. The surface chemistry of the internal walls of the channels is then modified by microcontact printing. The chip is submerged in a bead slurry where beads self-assemble based on surface chemistry and immobilize on the internal walls of the channels. Silicon channels (100 microm wide and 50 microm deep) have been covered with monolayers of streptavidin-, amino- and hydroxy-functionalized microspheres and resulted in good surface coverage of beads on the channel walls. A high-resolution pattern of lines of self-assembled streptavidin beads, as narrow as 5 microm, has also been generated on the bottom of a 500 microm wide and 50 microm deep channel. Flow tests were performed in sealed channels with the different immobilized beads to confirm that the immobilized beads could withstand the forces generated by water flowing in the channels. The presented results indicate that single beads can be precisely positioned within microfluidic devices based on self-assembly which is useful as screening and analysis tools within the field of biochemistry and organic chemistry.  相似文献   

2.
Chen X  Cheng X  Gooding JJ 《The Analyst》2012,137(10):2338-2343
Silver nanoparticles capped with mercaptoacetic acid and 2-aminoethanethiol short-chain alkanethiols were prepared by a one-step method in aqueous solution for monitoring pH and a range of heavy metal ions. The mode of transduction is optical, based on the change in aggregation of the nanoparticles in solution. Because of the different ionic interactions between the modified nanoparticles, these nanoparticle sensors can rapidly detect Pb(2+), Cu(2+) and Fe(2+), with detection limits as low as 1 × 10(-5) M, 5 × 10(-7) M and 5 × 10(-5) M respectively, as well as having the ability to detect Cu(2+) ions from Pb(2+) and Fe(2+). Furthermore, the same functionalised nanoparticles are also sensitive to pH; exhibiting a good linear dynamic response between pH 1 and 10.  相似文献   

3.
Abanulo JC  Harris RD  Sheridan AK  Wilkinson JS  Bartlett PN 《Faraday discussions》2002,(121):139-25;discussion 229-51
We describe the fabrication and characterisation of gold-coated graded index channel waveguide sensors designed for simultaneous electrochemical and surface plasmon resonance studies. The active sensing electrode area is a thin gold film between 0.5 and 5 mm in length and 200 microm wide deposited on top of a 3 microm wide waveguide which forms one arm of a Y-junction while the other arm of the Y-junction serves as a reference. Using these devices we have measured simultaneously the changes in transmittance through the device whilst carrying out cyclic voltammetry in either sulfuric or perchloric acid solution or during the deposition of an UPD layer of copper at the gold surface. In all cases we obtain stable and reproducible results which demonstrate the very high sensitivity of the devices to sub-monolayer changes occurring at the gold electrode surface. The response of these integrated optoelectrochemical devices is discussed in terms of a numerical model for the propagation of light within the waveguide structure.  相似文献   

4.
Detection of chemical processes on a single molecule scale is the ultimate goal of sensitive analytical assays. We recently reported the possibility to detect chemical modifications on individual molecules by monitoring a change in the single ion channel conductance of derivatives of gramicidin A (gA) upon reaction with analytes in solution. These peptide-based nanosensors detect reaction-induced changes in the charge of gA derivatives that were engineered to carry specific functional groups near their C-terminus.1 Here, we discuss five key design parameters to optimize the performance of such chemomodulated ion channel sensors. In order to realize an effective sensor that measures changes in charge of groups attached to the C-terminus of a gA pore, the following conditions should be fulfilled: (1) the change in charge should occur as close to the entrance of the pore as possible; (2) the charge before and after reaction should be well-defined within the operational pH range; (3) the ionic strength of the recording buffer should be as low as possible while maintaining a detectable flow of ions through the pore; (4) the applied transmembrane voltage should be as high as possible while maintaining a stable membrane; (5) the lipids in the supporting membrane should either be zwitterionic or charged differently than the derivative of gA. We show that under the condition of high applied transmembrane potential (>100 mV) and low ionic strength of the recording buffer (< or =0.10 M), a change in charge at the entrance of the pore is the dominant requirement to distinguish between two differently charged derivatives of gA; the conductance of the heterodimeric gA pore reported here does not depend on a difference in charge at the exit of the pore. We provide a simple explanation for this asymmetric characteristic based on charge-induced local changes in the concentration of cations near the lipid bilayer membrane. Charge-based ion channel sensors offer tremendous potential for ultrasensitive functional detection since a single chemical modification of each individual sensing element can lead to readily detectable changes in channel conductance.  相似文献   

5.
Porous silica beads with an average particle diameter between 0.2 and 3 microm have been applied as packing material in capillary electrochromatography (CEC). The experiments were directed to investigate whether it is really feasible and as promising as expected to use such small particles. In CEC, plate heights of H approximately/= 1-2 d(p) can be achieved which is smaller than the plate heights usually attained in high-performance liquid chromatography. Using a capillary packed with 0.5 microm silica beads we achieved a plate height of H = 3 d(p) indicating the presence of dispersive effects like Joule heating. Calculations demonstrate that at a field strength of about 800 V cm(-1) one third of the plate height can be lost by Joule heating effects if the heat is not removed by a cooling system. Additionally, the H(u) curve is still descending at the maximum electroosmotic flow (EOF) velocity we generated with the modified capillary electrophoresis instrument. To fully exploit the potential of submicron size silicas higher field strengths, i.e., higher EOF velocities, must be attained. To study the influence of the kind of packing on the EOF porous as well as nonporous silicas have been applied. The experiments clearly indicate that the EOF of porous and nonporous silicas is the same. Since the EOF is more or less exclusively generated by the packing material the zeta potential of n-octyl bonded 0.5 microm silica has been determined. The dependence of the zeta potential on the pH is identical to the dependence of the EOF on the pH in a packed capillary. The point of zero charge of the silica is at pH 2-3.  相似文献   

6.
Zhang X  Yin H  Cooper JM  Haswell SJ 《Electrophoresis》2006,27(24):5093-5100
A microfluidic format-based system has been developed for in situ monitoring of the calcium flux response to agonists using Chinese hamster ovary (CHO) cells. The assay is based on measuring the fluorescent intensity of the calcium-sensitive indicator, Fluo-4 AM, and was performed in a modified glass chip channel, whose surface was functionalised using a silanisation method with 3-aminopropyltriethoxysilane (APTS) (enabling the cells to be immobilised on the channel surface). CHO cells calcium flux response was measured for different agonists over a range of concentrations. Cells and reagents were introduced into the chip in a continuous flow as a series of plugs in a given sequence.  相似文献   

7.
Monitoring extracellular acidification rates (ECARs) is important for the study of cellular activities, since it allows for the evaluation of factors that alter metabolic function, such as stimulants, inhibitors, toxins as well as receptor and non-receptor mediated events. While the light addressable potentiometric sensor (Cytosensor Microphysiometer) has been the principal tool for ECARs measurement in the past, this work introduces a novel method that exploits an immobilized pH indicator on the surface of microcarrier beads (Sephadex) and is probed with a fiber optic coupled spectrophotometer. Likewise, live cells under investigation were also immobilized on microcarrier beads (Cytopore). These beads are metered, transported and monitored within a microfluidic system, termed as the Lab-on-Valve (LOV). Use of carrier beads in conjunction with Bead Injection Spectrophotometry and a Lab-on-Valve module (BIS-LOV), makes ECAR measurements reliable and automated. The feasibility of the BIS-LOV approach is demonstrated measuring ECARs of the mouse hepatocyte cell line, TABX.2S, grown on Cytopore beads packed within the central channel of the LOV system. These immobilized cells were perfused in a phosphate buffer carrier solution (capacity: 1 mmol L(-1), pH 7.4). Protons extruded from 10(5) to 10(6) cells were accumulated during a stopped flow period of 220 s followed by a pH measurement, detected by changes in absorbance of the pH indicator bonded to the microcarrier beads. Addition of metabolic inhibitors (sodium azide, oxamic acid) to the carrier buffer solution can induced an increase or decrease of the basal proton extrusion rate in a very reproducible manner. Comparison of the BIS-LOV technique to the Cytosensor microphysiometer and literature confirms the validity of this novel approach, highlighting its advantages and suggesting future improvements that will make the BIS-LOV a practical tool for routine ECARs measurement.  相似文献   

8.
Implementing DNA and protein microarrays into lab-on-a-chip systems can be problematic since these are sensitive to heat and strong chemicals. Here, we describe the functionalization of a microchannel with two types of magnetic beads using hydrodynamic focusing combined with a passive magnetic separator with arrays of soft magnetic elements. The soft magnetic elements placed on both sides of the channel are magnetized by a relatively weak applied external magnetic field (21 mT) and provide magnetic field gradients attracting magnetic beads. Flows with two differently functionalized magnetic beads and a separating barrier flow are introduced simultaneously at the two channel sides and the centre of the microfluidic channel, respectively. On-chip experiments with fluorescence labeled beads demonstrate that the two types of beads are captured at each of the channel sidewalls. On-chip hybridization experiments show that the microfluidic systems can be functionalized with two sets of beads carrying different probes that selectively recognize a single base pair mismatch in target DNA. By switching the places of the two types of beads it is shown that the microsystem can be cleaned and functionalized repeatedly with different beads with no cross-talk between experiments.  相似文献   

9.
An in situ method of modifying the chemistry and topology of microfluidic surfaces in order to mimic the cellular environment is described. The binding of functionalised microbeads to microfluidic channels allows the surface-to-volume ratio of the system, and thus the number of biomolecules available for reaction, to be vastly increased, thereby enhancing the sensitivity of biochemical analyses. The sensitivity and specificity of the technique were first investigated via the study of carbohydrate-protein interactions. Beads featuring hydrazide moieties were adhered to the channel surface, after which carbohydrates (galactose and mannose) were bound to the beads in situ and reacted with fluorescently labelled proteins. Results showed a six-fold increase in fluorescent signal compared to the same process performed on a glass surface without the presence of beads, thereby demonstrating the increase in valence afforded by the method. In a subsequent study, beads, modified with galactose moieties via the in situ functionalisation technique, were used to perform studies of colon tumour cells from a cell sample. Here, the carcinoma cells exhibited superior adhesion than the normal cells due to an increased expression of active galactose receptors, thereby demonstrating the success of the biofunctionalisation method for investigating cellular mechanisms.  相似文献   

10.
The electrochemical manipulation of the local pH at a polymer functionalised electrode has been achieved in order to enhance the electrochemical response to cationic analytes. The changes in pH have been shown to provide a method for significantly enhancing the analytical signal towards the model compounds, dopamine and p-aminophenol. The procedure was found to operate irrespective of the electrical properties of the film. The main requirement for this electroanalytical system is that the film contains acidic groups within the polymer backbone. In the carboxylic acid functionalised polypyrrole film studied here, the performance was found to be greatest when the bulk solution pH was less than the pKa of the acid groups. The mechanism attributed to the enhanced response is elucidated and the limitations of the technique are assessed.  相似文献   

11.
Choi CJ  Cunningham BT 《Lab on a chip》2006,6(10):1373-1380
A method for simultaneously integrating label-free photonic crystal biosensor technology into microfluidic channels by a single-step replica molding process is presented. By fabricating both the sub-micron features of the photonic crystal sensor structure and the >10 microm features of a flow channel network in one step at room temperature on a plastic substrate, the sensors are automatically self-aligned with the flow channels, and patterns of arbitrary shape may be produced. By measuring changes in the resonant peak reflected wavelength from the photonic crystal structure induced by changes in dielectric permittivity within an evanescent field region near its surface, detection of bulk refractive index changes in the fluid channel or adsorption of biological material to the sensor surface is demonstrated. An imaging detection instrument is used to characterize the spatial distribution of the photonic crystal resonant wavelength, gathering thousands of independent sensor readings within a single fluid channel.  相似文献   

12.
Axial development and radial non-uniformity of flow in packed columns   总被引:4,自引:0,他引:4  
Flow inhomogeneity and axial development in low-pressure chromatographic columns have been studied by magnetic resonance imaging velocimetry. The columns studied included (a) an 11.7-mm I.D. column packed with either 50 microm diameter porous polyacrylamide, or 99 or 780 microm diameter impermeable polystyrene beads, and (b) a 5-mm I.D. column commercially packed with 10 microm polymeric beads. The packing methods included gravity settling, slurry packing, ultrasonication, and dry packing with vibration. The magnetic resonance method used averaged apparent fluid velocity over both column cross-sections and fluid displacements greater than one particle diameter and hence permits assessment of macroscopic flow non-uniformities. The results confirm that now non-uniformities induced by the conical distributor of the 11.7-mm I.D. column or the presence of voids at the column entrance relax on a length scale of the column radius. All of the 11.7-mm I.D. columns examined exhibit near wall channeling within a few particle diameters of the wall. The origins of this behavior are demonstrated by imaging of the radial dependence of the local porosity for a column packed with 780 microm beads. Columns packed with the 99-microm beads exhibit reduced flow in a region extending from ten to three-to-five particle diameters from the wall. This velocity reduction is consistent with a reduced porosity of 0.35 in this region as compared to approximately 0.43 in the bulk of the column. Ultrasonicated and dry-packed columns exhibit enhanced flow in a region located between approximately eight and 20 particle diameters from the wall. This enhancement maybe caused by packing density inhomogeneity and/or particle size segregation caused by vibration during the packing process. No significant non-uniformities on length scales of 20 microm or greater were observed in the commercially packed column packed with 10 microm particles.  相似文献   

13.
We demonstrate a method for generating flow within a microfluidic channel using an optically driven pump. The pump consists of two counter rotating birefringent vaterite particles trapped within a microfluidic channel and driven using optical tweezers. The transfer of spin angular momentum from a circularly polarised laser beam rotates the particles at up to 10 Hz. We show that the pump is able to displace fluid in microchannels, with flow rates of up to 200 microm(3) s(-1) (200 fL s(-1)). The direction of fluid pumping can be reversed by altering the sense of the rotation of the vaterite beads. We also incorporate a novel optical sensing method, based upon an additional probe particle, trapped within separate optical tweezers, enabling us to map the magnitude and direction of fluid flow within the channel. The techniques described in the paper have potential to be extended to drive an integrated lab-on-chip device, where pumping, flow measurement and optical sensing could all be achieved by structuring a single laser beam.  相似文献   

14.
This paper describes the development of a rapid and sensitive enzyme-linked electrochemical genosensor using a novel microfluidic-based platform. In this work, hybridization was performed on streptavidin-coated paramagnetic micro-beads functionalized with a biotinylated capture probe. The complementary sequence was then recognized via sandwich hybridization with a capture probe and a biotinylated signaling probe. After labeling the biotinylated hybrid with a streptavidin-alkaline phosphatase conjugate, the beads were introduced in a disposable cartridge composed of eight parallel microchannels etched in a polyimide substrate. The modified beads were trapped with a magnet addressing each microchannel individually. The presence of microelectrodes in each channel allowed direct electrochemical detection of the enzymatic product within the microchannel. Detection was performed in parallel within the eight microchannels, giving rise to the possibility of performing a multiparameter assay. Quantitative determinations of the analyte concentrations were obtained by following the kinetics of the enzymatic reaction in each channel. The chip was regenerated after each assay by removing the magnet and thus releasing the magnetic beads. The system was applied to the analytical detection of PCR amplified samples with a RSD% = 6. A detection limit of 0.2 nM was evaluated.  相似文献   

15.
Pentacene-based organic thin-film transistors were used to create highly sensitive, real-time electronic sensors for selective antibody detection. Bovine serum albumin was covalently attached to a modified pentacene surface to selectively detect the label free monoclonal antiBSA. These sensors displayed a high affinity constant (K(A)) of (1.1 ± 3) × 10(7) M(-1) at pH 7, which is 1 order of magnitude higher than those obtained with a highly sensitive surface plasmon resonance spectroscopy detection system. Furthermore, a high degree of discrimination in the hybrid antiBSA charges was achieved at different pH values. This demonstration of fast, label-free, real-time detection of nanoscale biomolecules in aqueous buffer solutions using the organic transistor sensing platform will have a significant impact on high-performance microarrays in addition to discriminating the presence of ionizable groups.  相似文献   

16.
Zhao Y  Cho SK 《Lab on a chip》2006,6(1):137-144
This paper describes a new microparticle sampler where particles can be efficiently swept from a solid surface and sampled into a liquid medium using moving droplets actuated by the electrowetting principle. We successfully demonstrate that super hydrophilic (2 microm and 7.9 microm diameter glass beads of about 14 degrees contact angle), intermediate hydrophilic (7.5 microm diameter polystyrene beads of about 70 degrees contact angle), and super hydrophobic (7.9 microm diameter Teflon-coated glass beads and 3 microm size PTFE particles of over 110 degrees contact angles) particles on a solid surface are picked up by electrowetting-actuated moving droplets. For the glass beads as well as the polystyrene beads, the sampling efficiencies are over 93%, in particular over 98% for the 7.9 microm glass beads. For the PTFE particles, however, the sampling efficiency is measured at around 70%, relatively lower than that of the glass and polystyrene beads. This is due mainly to the non-uniformity in particle size and the particle hydrophobicity. In this case, the collected particles staying (adsorbing) on the air-to-water interface hinder the droplet from advancing. This particle sampler requires an extremely small amount of liquid volume (about 500 nanoliters) and will thus be highly compatible and easily integrated with lab-on-a-chip systems for follow-up biological/chemical analyses.  相似文献   

17.
A microfluidic device is described in which an electrospray interface to a mass spectrometer is integrated with a capillary electrophoresis channel, an injector and a protein digestion bed on a monolithic substrate. A large channel, 800 microm wide, 150 microm deep and 15 mm long, was created to act as a reactor bed for trypsin immobilized on 40-60 microm diameter beads. Separation was performed in channels etched 10 microm deep, 30 microm wide and about 45 mm long, feeding into a capillary, attached to the chip with a low dead volume coupling, that was 30 mm in length, with a 50 microm i.d. and 180 microm o.d. Sample was pumped through the reactor bed at flow rates between 0.5 and 60 microL/min. The application of this device for rapid digestion, separation and identification of proteins is demonstrated for melittin, cytochrome c and bovine serum albumin (BSA). The rate and efficiency of digestion was related to the flow rate of the substrate solution through the reactor bed. A flow rate of 1 or 0.5 microL/min was found adequate for complete consumption of cytochrome c or BSA, corresponding to a digestion time of 3-6 min at room temperature. Coverage of the amino acid sequence ranged from 92% for cytochrome c to 71% for BSA, with some missed cleavages observed. Melittin was consumed within 5 s. In contrast, a similar extent of digestion of melittin in a cuvet took 10-15 min. The kinetic limitations associated with the rapid digestion of low picomole levels of substrate were minimized using an integrated digestion bed with hydrodynamic flow to provide an increased ratio of trypsin to sample. This chip design thus provides a convenient platform for automated sample processing in proteomics applications.  相似文献   

18.
A method based on capillary electrophoresis with electrochemical detection (CE-ED) to calculate the rate constants and activation energy of 3-chloro-1,2-propanediol (3-MCPD) hydrolysis was described. Effects of several factors, such as the pH value and the concentration of the running buffer, separation voltage, injection time and the potential applied to the working electrode, were investigated to find the optimum conditions. With a 50 cm length of 25 microm diameter fused-silica capillary at a separation of 10 kV, well-defined separation of 3-chloro-1,2-propanediol from glycerol was achieved in 30 mmol/l borax (pH 9.24) within 13 min. Operated in a wall-jet configuration, a 328 microm copper-disk electrode used as the working electrode exhibits good response at 0.65 V (versus SCE) for 3-MCPD and glycerol. The rate constants of 3-MCPD hydrolysis at different temperatures were determined by monitoring the concentration changes of 3-MCPD. At 80, 85 and 90 degrees C, the measured rate constants of 3-MCPD hydrolysis were 3.8 x 10(-3) min(-1), 7.1 x 10(-3) min(-1) and 11.5 x 10(-3) min(-1), respectively. The activation energy for 3-MCPD hydrolysis was calculated to be 118.1 kJ/mol, which is in good agreement with the value in the literature.  相似文献   

19.
Kim KS  Park JK 《Lab on a chip》2005,5(6):657-664
This paper describes a novel microfluidic immunoassay utilizing binding of superparamagnetic nanoparticles to beads and deflection of these beads in a magnetic field as the signal for measuring the presence of analyte. The superparamagnetic 50 nm nanoparticles and fluorescent 1 microm polystyrene beads are immobilized with specific antibodies. When target analytes react with the polystyrene beads and superparamagnetic nanoparticles simultaneously, the superparamagnetic nanoparticles can be attached onto the microbeads by the antigen-antibody complex. In the poly(dimethylsiloxane)(PDMS) microfluidic channel, only the microbeads conjugated with superparamagnetic nanoparticles by analytes consequently move to the high gradient magnetic fields under the specific applied magnetic field. In this study, the magnetic force-based microfluidic immunoassay is successfully applied to detect the rabbit IgG and mouse IgG as model analytes. The lowest concentration of rabbit IgG and mouse IgG measured over the background is 244 pg mL(-1) and 15.6 ng mL(-1), respectively. The velocities of microbeads conjugated with superparamagnetic nanoparticles are demonstrated by magnetic field gradients in microfluidic channels and compared with the calculated magnetic field gradients. Moreover, dual analyte detection in a single reaction is also performed by the fluorescent encoded microbeads in the microfluidic device. Detection range and lower detection limit can be controlled by the microbeads concentration and the higher magnetic field gradient.  相似文献   

20.
Monodisperse poly(glycidyl methacrylate-divinylbenzene) microspheres were prepared by a simple one-step dispersion polymerization process. Examination of the polymeric microspheres showed that they had a mean particle diameter of 3 microm and dual pore size distribution with mean pore diameters of 300 and 800 A. The microspheres were functionalized by introducing quaternary ammonium/octadecyl groups to obtain positively charged beads in a wide pH range. The functionalized beads were packed into fused-silica capillary having 50 microm inner diameter and used to separate erythromycin derivatives by capillary electrochromatography (CEC). These samples require gradient elution when separated by high-performance liquid chromatography (HPLC) or micro-HPLC, but with the new columns isocratic elution suffices for their separation by CEC. The column efficiency ranged from 40,000 to 50,000 theoretical plates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏