首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel amperometric sensor and chromatographic detector for determination of parathion has been fabricated from a multi-wall carbon nano-tube (MWCNT)/Nafion film-modified glassy-carbon electrode (GCE). The electrochemical response to parathion at the MWCNT/Nafion film electrode was investigated by cyclic voltammetry and linear sweep voltammetry. The redox current of parathion at the MWCNT/Nafion film electrode was significantly higher than that at the bare GCE, the MWCNT-modified GCE, and the Nafion-modified GCE. The results indicated that the MWCNT/Nafion film had an efficient electrocatalytic effect on the electrochemical response to parathion. The peak current was proportional to the concentration of parathion in the range 5.0×10–9–2.0×10–5 mol L–1. The detection limit was 1.0×10–9 mol L–1 (after 120 s accumulation). In high-performance liquid chromatography with electrochemical detection (HPLC–ED) a stable and sensitive current response was obtained for parathion at the MWCNT/Nafion film electrode. The linear range for parathion was over four orders of magnitude and the detection limit was 6.0×10–9 mol L–1. Application of the method for determination of parathion in rice was satisfactory.  相似文献   

2.
An electrochemical method for the determination of trace levels of mercury based on a multi-walled carbon nanotubes (MWNT) film coated glassy carbon electrode (GCE) is described. In 0.1 mol L–1 HCl solution containing 0.02 mol L–1 KI, Hg2+ was firstly preconcentrated at the MWNT film and then reduced at –0.60 V. During the anodic potential sweep, reduced mercury was oxidized, and then a sensitive and well-defined stripping peak at about –0.20 V appeared. Under identical conditions, a MWNT film coated GCE greatly enhances the stripping peak current of mercury in contrast to a bare GCE. Low concentrations of I remarkably improve the determining sensitivity, since this increases the accumulation efficiency of Hg2+ at the MWNT film coated GCE. The stripping peak current is proportional to the concentration of Hg2+ over the range 8×10–10–5×10–7 mol L–1. The lowest detectable concentration of Hg2+ is 2×10–10 mol L–1 at 5 min accumulation. The relative standard deviation (RSD) at 1×10–8 mol L–1 Hg2+ was about 6% (n=10). By using this proposed method, Hg2+ in some water samples was determined, and the results were compared with those obtained by atomic absorption spectrometry (AAS). The two results are similar, suggesting that the MWNT-film coated GCE has great potential in practical analysis.  相似文献   

3.
A novel procedure has been developed for spectrophotometric determination of anionic surfactants in water using a solenoid micro-pump as fluid-propulsion device. The proposed method is based on substitution of methyl orange (MO) by anionic surfactants in the formation of an ion-pair with the cetyl pyridine ion (CPC+) at pH 5.0. The flow network comprised four solenoid micro-pumps which, under microcomputer control, enabled sample and reagent introduction, and homogenisation in the reaction zone. The system is flexible and simple to operate and control, and sensitive and precise. The analytical plot for the anionic surfactant was linear between 1.43×10–6 and 1.43×10–5 mol L–1 (0.5 to 5.0 mg L–1; R=0.997, n=5). The relative standard deviation was 0.8% (n=11) for a sample containing 5.74×10–6 mol L–1 (2 mg L–1) surfactant. The limit of detection was 9.76×10–8 mol L–1 (0.034 mg L–1) and the sampling throughput was 60 determinations per hour. The results obtained for washing-water samples were comparable with those obtained by use of the reference method, and no significant differences at the 95% confidence level were observed.  相似文献   

4.
A cobalt hexacyanoferrate (CoHCF) nanoparticle (size ca. 60 nm) chemically modified electrode (CME) was fabricated and the electrochemical behavior of thiols at this nanosized CoHCF CME was studied. In comparison with a bare glassy carbon (GC) electrode and with a general CoHCF CME which was electrodeposited in the traditional manner, the present nanosized CoHCF CME efficiently performed electrocatalytic oxidation for glutathione (GSH) and L-Cysteine (L-Cys) with relatively high sensitivity, outstanding stability, and long-life. Combined with high-performance liquid chromatography (HPLC), the nanosized CoHCF CME was used for electrochemical determination (ECD) of GSH and L-Cys. The peak currents were a linear function of concentrations in the range 2.0×10–7 to 2.0×10–4 mol L–1 for both GSH and L-Cys, with detection limits of 1.2×10–7 and 1.0×10–7 mol L–1, respectively. Coupled with microdialysis sampling, the HPLC–ECD system has been successfully used to assess the GSH and L-Cys content of rat striatum.  相似文献   

5.
A new, simple, rapid, and sensitive spectrophotometric method has been developed for the determination of manganese in sewage. The method is based on the reaction of manganese with derivatives of 1,3,3-trimethyl-2-[3-(1,3,3-trimethyl-1,3-H-indol-2-ylidene)propenyl]-3H-indolium to form a colored ion associate with a sensitive absorption maximum at 560 nm. The appropriate reaction conditions have been established: pH 8.5–10.0, 1.25–2.3×10–3 mol L–1 1-nitroso-2-naphthol, and 1.6–2.4×10–4 mol L–1 dye reagent. Beer's law is obeyed for manganese concentrations up to 4.2 mg L–1. The limit of detection is 0.01 mg L–1 Mn2+; the molar absorptivity of the ion associate was 7.5×104 L mol–1 cm–1. The effect of various foreign ions was examined. A reaction mechanism is suggested. The developed procedure was tested for determination of manganese in sewage with satisfactory precision and accuracy.  相似文献   

6.
A new lanthanide-sensitized luminescence system: europium–sparfloxacin–1,10-phenanthroline–sodium dodecyl sulfate has been discovered. The spectrofluorimetric properties of the system were studied. The effect of experimental conditions on the fluorescence intensity was defined. Under the optimum conditions, the fluorescence intensity of the system is a linear function of the concentration of europium in the range 5.0×10–9–1.0×10–6 mol L–1 and the detection limit is 1.0×10–10 mol L–1. The system was used for the determination of trace amounts of europium in rare earth samples with satisfactory results.  相似文献   

7.
The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.  相似文献   

8.
Procedures for trace cobalt determinations by adsorptive stripping voltammetry at in situ and ex situ plated bismuth film electrodes are presented. These exploit the enhancement of the cobalt peak obtained by using the Co(II)–dimethylglyoxime–cetyltrimethylammonium bromide–piperazine-N,N-bis(2-ethanesulfonic acid) system. The calibration graph for an accumulation time of 120 s was linear from 2 × 10–10 to 2 × 10–8 mol L–1. The relative standard deviation from five determinations of cobalt at a concentration of 5 × 10–9 mol L–1 was 5.2%. The detection limit for an accumulation time of 300 s was 1.8 × 10–11 mol L–1. The proposed procedure was applied to cobalt determination in certified reference materials and in tap and river water samples.  相似文献   

9.
Liquid chromatography with amperometric detection (LC-AD) is developed and applied to simultaneously determine five aromatic amines. In the LC-AD, a new carbon nanotubes/poly(3-methylthiophene) modified dual-electrode is fabricated and then used as the working electrode. It is found that this chemically modified electrode (CME) exhibits efficiently electrocatalytic oxidation for aromatic amines with relatively high sensitivity, stability and long-life. Thus, lower detection in LC-AD can be achieved, which are 4.0 × 10–8 mol L–1 for aniline, 1.6 ×10–7 mol L–1 for 4-nitroaniline, 1.0 × 10–7 mol L–1 for 4-chloroaniline, 1.5 × 10–7 mol L–1 for 1-naphthylamine, 1.7 × 10–7 mol L–1 for 2-bromoaniline. The recoveries of the five analytes are also determined, which range between 0.95 and 1.05 for drinking water, 0.86 and 1.10 for the LiWa River water.  相似文献   

10.
The polarographic characteristics of telmisartan have been investigated in 0.8 mol L–1 NH3.H2O–NH4Cl (pH 8.9)–0.01 mol L–1 H2O2 as supporting electrolyte. The results demonstrate that the polarographic reduction wave at ca. –1.30 V in the absence of H2O2 is a catalytic hydrogen wave, and the reduction wave enhanced by H2O2 is a so-called parallel catalytic hydrogen wave. The analytical sensitivity of the parallel catalytic hydrogen wave is ca. 60 times higher than that of the corresponding catalytic hydrogen wave. Based on the parallel catalytic hydrogen wave a novel method has been developed for determination of telmisartan by linear sweep polarography. The calibration curve is linear in the range 2.0×10–8–2.0×10–6 mol L–1 and the detection limit is 1.0×10–8 mol L–1. The precision is excellent with relative standard deviations of 2.6% at a concentration of 1.0×10–7 mol L–1 telmisartan. The proposed method has been applied to the direct determination of the telmisartan in capsule forms and biological samples. The proposed method has been proved to be advantageous over existing CZE and MEKC methods in simplicity, rapidity, and reproducibility.  相似文献   

11.
Under natural conditions gold has low solubility that reduces its bioavailability, a critical factor for phytoextraction. Researchers have found that phytoextraction can be improved by using synthetic chelating agents. Preliminary studies have shown that desert willow (Chilopsis linearis), a common inhabitant of the Chihuahuan Desert, is able to extract gold from a gold-enriched medium. The objective of the present study was to determine the ability of thiocyanate to enhance the gold-uptake capacity of C. linearis. Seedlings of this plant were exposed to the following hydroponics treatment: (1) 5 mg Au L–1 (2.5×10–5 mol L–1), (2) 5 mg Au L–1+10–5 mol L–1 NH4SCN, (3) 5 mg Au L–1+5×10–5 mol L–1 NH4SCN, and (4) 5 mg Au L–1+10–4 mol L–1 NH4SCN. Each treatment had its respective control. After 2 weeks we determined the effect of the treatment on plant growth and gold content by inductively coupled plasma–optical emission spectroscopy (ICP–OES). No signs of shoot-growth inhibition were observed at any NH4SCN treatment level. The ICP–OES analysis showed that addition of 10–4 mol L–1 NH4SCN increased the concentration of gold by about 595, 396, and 467% in roots, stems, and leaves, respectively. X-ray absorption spectroscopy (XAS) studies showed that the oxidation state of gold was Au(0) and that gold nanoparticles were formed inside the plants.  相似文献   

12.
A flow-injection ultrafiltration sampling chemiluminescence system for on-line determination of cimetidine–bovine serum albumin (BSA) interaction is proposed in this paper. Cimetidine can be oxidized by N-bromosuccinimide (NBS) and sensitized by fluorescein to produce high chemiluminescence emission in basic media. The concentration of cimetidine is linear with the CL intensity in the range 3×10–7–1×10–4 mol L–1 with a detection limit of 1×10–7 mol L–1 (3). The drug and protein were mixed in different molar ratios in 0.067 mol L–1 phosphate buffer, pH 7.4, and incubated at 37 °C in a water bath. The ultrafiltration probe was utilized to sample the mixed solution at a flow rate of 5 µL min–1. The data obtained by the proposed ultrafiltration flow-injection chemiluminescence method was analyzed with Scrathard analysis and a Klotz plot. The estimated association constant (K) and the number of the binding site (n) on one molecule of BSA by Scrathard analysis and Klotz plot were 3.15×104 L mol–1 and 0.95, 3.25×104 L mol–1 and 0.92, respectively. The proposed system proved that flow-injection chemiluminescence analysis coupled with on-line ultrafiltration sampling is a simple and reliable technique for the study of drug–protein interaction.  相似文献   

13.
We report the electroanalytical determination of lead by anodic stripping voltammetry at in-situ-formed, bismuth-film-modified, boron-doped diamond electrodes. Detection limits in 0.1 mol L–1 nitric acid solution of 9.6x10–8 mol L–1 (0.2 ppb) and 1.1x10–8 mol L–1 (2.3 ppb) were obtained after 60 and 300 s deposition times, respectively. An acoustically assisted deposition procedure was also investigated and found to result in improved limits of detection of 2.6×10–8 mol L–1 (5.4 ppb) and 8.5×10–10 mol L–1 (0.18 ppb) for 60 and 300 s accumulation times, respectively. Furthermore, the sensitivity obtained under quiescent and insonated conditions increased from 5.5 (quiescent) to 76.7 A mol–1 L (insonated) for 60 s accumulation and from 25.8 (quiescent) to 317.6 A mol–1 L (insonated) for 300 s accumulation. Investigation of the use of ultrasound with diluted blood revealed detection limits of the order of 10–8 mol L–1 were achievable with excellent inter- and intra-reproducibility and sensitivity of 411.9 A mol–1 L . For the first time, electroanalytical detection of lead in diluted blood is shown to be possible by use of insonated in-situ-formed bismuth-film-modified boron-doped diamond electrodes. This method is a rapid, sensitive, and non-toxic means of clinical sensing of lead in whole human blood.  相似文献   

14.
A novel organic gel film modified electrode was simply and conveniently fabricated by casting LixMoOy and polypropylene carbonate (PPC) onto the surface of a gold electrode. The cyclic voltammetry and amperometry studies demonstrated that the LixMoOy film modified electrode has a high stability and a good electrocatalytic activity for the reduction of iodate. In amperometry, a good linear relationship between the steady current and the concentration of iodate was obtained in the range from 3×10–7 to 1×10–4 mol L–1 with a correlation coefficient of 0.9997 and a detection limit of 1×10–7 mol L–1.  相似文献   

15.
The construction and electroanalytical response characteristics of poly(vinyl chloride) matrix ion-selective sensors (ISSs) for drotaverine hydrochloride are described. The membranes incorporate ion-association complexes of drotaverine with tetraphenylborate, picrate, tetraiodomercurate, tetraiodobismuthate, Reinecke salt, and heteropolycompounds of Keggin structure—molybdophosphoric acid, tungstophosphoric acid, molybdosiliconic acid and tungstosiliconic acid as electroactive materials for ionometric sensor controls. These ISSs have a linear response to drotaverine hydrochloride over the range 8×10–6 to 5×10–2 mol L–1 with cationic slopes from 51 to 58 mV per concentration decade. These ISSs have a fast response time (up to 1 min), a low determination limit (down to 4.3×10–6 mol L–1), good stability (3–5 weeks), and reasonable selectivity. Permeabilities and ion fluxes through a membrane were calculated for major and interfering ions. Dependences of the transport properties of the membranes on the concentrations of the ion exchanger and near-membrane solution and their electrochemical characteristics are presented. The ISSs were used for direct potentiometry and potentiometric titration (sodium tetraphenylborate) of drotaverine hydrochloride. Results with mean accuracy of 99.1±1.0% of nominal were obtained which corresponded well to data obtained by use of high-performance liquid chromatography.  相似文献   

16.
This work describes an electroanalytical investigation of dopamine using cyclic voltammetry (CV) and the graphite–polyurethane composite electrode (GPU). In CV studies, well-defined redox peaks characterize the oxidation process at the GPU electrode, which is indicative of electrocatalytic effects associated with active sites on the GPU electrode surface. A new analytical methodology was developed using the GPU electrode and square wave voltammetry (SWV) in BR buffer solution (0.1 mol L–1; pH 7.4). Analytical curves were constructed under optimized conditions (f=60s–1, Ea=50 mV, EI=2 mV) and detection and quantification limits of 6.4×10–8 mol L–1 (12.1 g L–1) and 5.2×10–6 mol L–1 (0.9 mg L–1), respectively, were achieved. The precision of the method was checked by performing ten successive measurements for a 9.9×10–6 mol L–1 dopamine solution. For intra-assay and inter-assay precisions, the relative standard deviations were 1.9 and 2.3%, respectively. In order to evaluate the developed methodology, the determination of dopamine was performed with good sensitivity and selectivity, without the interference of ascorbic acid in synthetic cerebrospinal fluid, which indicates that the new methodology enables reliable analysis of dopamine.  相似文献   

17.
The clinical manifestations of gout result from the formation and deposition of uric acid (UA) crystals. The monitoring of UA level in less invasive biological samples such as saliva is suggested for diagnosis and therapy of gout, hyperuricemia and the Lesch–Nyhan syndrome. In order to investigate the correlation between trace amounts of UA in human saliva and urine and explore the potential application in fast diagnosis of gout, capillary electrophoresis with electrochemical detection (CE–ED) was applied for the determination of UA in human saliva and urine in this work. Under the optimum conditions, UA and three coexisting analytes could be well separated within 14 min at the separation voltage of 14 kV in 80 mmol L–1 borax running buffer (pH 7.8). A good linear relationship was established between peak current and concentration of analytes over two orders of magnitude with detection limits (S/N=3) ranging from 1.09×10–7 to 5.0×10–7 mol L–1 for all analytes. This proposed method has been successfully applied for study of the correlation between the UA content of human saliva and urine, providing an alternative and convenient method for rapid diagnosis of gout.  相似文献   

18.
A sensitive procedure for determination of micro-traces of Co(II) by adsorptive stripping voltammetry is proposed. The procedure exploits the enhancement of the cobalt peak obtained by use of the system Co(II)–dimethylglyoxime–piperazine-1,4-bis(2-ethanesulfonic acid)–cetyltrimethylammonium bromide. Using the optimized conditions, a detection limit (based on the 3 criterion) for Co(II) of 1.2×10–11 mol L–1 (0.7 ng L–1) was achieved. The calibration plot for an accumulation time of 30 s was linear from 5×10–11 to 4×10–9 mol L–1. The procedure was validated by analysis of certified reference materials and natural water samples.  相似文献   

19.
The oxidative behaviour of the antidiabetic agent glibenclamide on a bare carbon paste electrode (CPE) and a Sephadex-modified carbon paste electrode (SMCPE) was explored by cyclic and differential pulse voltammetry (DPV). The analysis procedure consisted of an open circuit accumulation step in stirred sample solution of Britton-Robinson buffer (0.04 mol L–1, pH 2.0). This was followed by medium exchange to a clean solution of Britton-Robinson buffer (0.04 mol L–1, pH 5.0), and subsequently an anodic potential scan was effected to obtain the voltammetric peak. The glibenclamide oxidation peak current obtained by DPV was proportional to the concentration of the glibenclamide in the range of 1.0×10–9 mol L–1 to 5.0×10–8 mol L–1 for 180 s accumulation time, with a detection limit of 4.0×10–10 mol L–1. A method was developed for the determination of glibenclamide in formulation and spiked human serum. Moreover, the proposed procedure was used to estimate the serum concentrations after oral administration of a 5 mg tablet of glibenclamide to three diabetic subjects.  相似文献   

20.
An electrochemical method has been established for the determination of lovastatin (LV). It is based on the enhanced oxidation of lovastatin at a novel acetylene black–dihexadecyl hydrogen phosphate composite-modified glassy-carbon electrode (AB–DHP/GCE) in the presence of Triton X-100. This electrode was prepared by dispersion of acetylene black particles in an aqueous suspension of DHP and the formation of a stable film of the resulting AB–DHP composite on the surface of a glassy carbon electrode (GCE). As a result of modification of the AB–DHP composite, the electrochemical response of lovastatin at GCE was apparently enhanced; this was apparent as amplification of the oxidation current and the negative shift of the oxidation potential. The oxidation current can be further increased in the presence of a trace amount of Triton X-100. The enhanced oxidation of lovastatin at AB–DHP/GCE was due to enlargement of the effective electrode area, catalysis of lovastatin oxidation by AB, and accumulation of lovastatin at the hydrophobic surface of the DHP layer, which would be enhanced by the coherence with Triton X-100. The effects of some working conditions on the oxidation current of lovastatin were tested and the calibration plot was examined. The result showed that the oxidation current was a linear function of lovastatin concentration in the range 2.5×10–8–1.0×10–6 mol L–1 and a low detection limit of 4.0×10–9 mol L–1 was obtained under optimum conditions. This electrode system was applied to the determination of lovastatin in dosage drug forms and the results were in accordance with the ultraviolet–visible spectroscopy method.  相似文献   