首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes the most important articles that have been published on amino acid analysis using CE during the period from June 2009 to May 2011 and follows the format of the previous articles of Smith (Electrophoresis 1999, 20, 3078-3083), Prata et al. (Electrophoresis 2001, 22, 4129-4138) and Poinsot et al. (Electrophoresis 2003, 24, 4047-4062; Electrophoresis 2006, 27, 176-194; Electrophoresis 2008, 29, 207-223; Electrophoresis 2010, 31, 105-121). We present new developments in amino acid analysis with CE, which are reported describing the use of lasers or light emitting diodes for fluorescence detection, conductimetry electrochemiluminescence detectors, mass spectrometry applications, and lab-on-a-chip applications using CE. In addition, we describe articles concerning clinical studies and neurochemical applications of these techniques.  相似文献   

2.
Recent advances in amino acid analysis by capillary electrophoresis   总被引:3,自引:0,他引:3  
Poinsot V  Bayle C  Couderc F 《Electrophoresis》2003,24(22-23):4047-4062
Amino acids are studied extensively using capillary electrophoresis. In a previous article, we reviewed applications reported in the period 1999-early 2001 (Prata, C., Bonnafous, P., Fraysse, N., Treilhou, M., Poinsot, V., Couderc, F., Electrophoresis 2001, 22, 4129-4138). In this article we follow on with this review for the period end of 2001-beginning of 2003. We will report the developments of detection methods, separations of enantiomers, the new medical applications, and amino acids in food and plants. This review shows that CE is more and more important for the amino acid analysis.  相似文献   

3.
This paper describes a number of articles that have been published on amino acid analysis using CE during the period from June 2003 to May 2005. This review article follows the previous ones of Smith (Electrophoresis 1999, 20, 3078-3083), Prata et al. (Electrophoresis 2001, 22, 4129-4138), and Poinsot et al. (Electrophoresis 2003, 24, 4047-4062). Several new developments in amino acid analysis with CE are reported concerning UV detection, LIF, MS, and NMR. In addition, we describe articles concerning clinical and pharmaceutical studies, neuroclinical applications, and agricultural and food analysis.  相似文献   

4.
Recent advancements in amino acid analysis using capillary electrophoresis   总被引:7,自引:0,他引:7  
Smith JT 《Electrophoresis》1999,20(15-16):3078-3083
Recent advances in the analysis of amino acids using capillary electrophoresis are addressed. This area of research continues to receive increased attention as is evident from the 62 references reviewed. This review discusses current detection strategies including UV absorbance, laser-induced fluorescence, electrochemical, and others. Separation methodologies for both derivatized and underivatized amino acids are reviewed. Both direct and indirect enantiomeric resolution of amino acids are addressed. Applications utilizing capillary electrophoresis for the analysis of amino acids are discussed. This review covers literature published in 1997 and 1998.  相似文献   

5.
With the maturation of microfluidic technologies, microchip electrophoresis has been widely employed for amino acid analysis owing to its advantages of low sample consumption, reduced analysis time, high throughput, and potential for integration and automation. In this article, we review the recent progress in amino acid analysis using microchip electrophoresis during the period from 2007 to 2012. Innovations in microchip materials, surface modification, sample introduction, microchip electrophoresis, and detection methods are documented, as well as nascent applications of amino acid analysis in single-cell analysis, microdialysis sampling, food analysis, and extraterrestrial exploration. Without doubt, more applications of microchip electrophoresis in amino acid analysis may be expected soon.  相似文献   

6.
In this review, the main aspects related to the separation of different groups of antibiotics by CE as well as the different applications reported in the literature from the beginning 2003 till May 2005 will be provided to the readers. Firstly, the experimental conditions employed to achieve the analysis of antibiotics by CE are given. Then, the main applications performed in the pharmaceutical, clinical, food, and environmental fields have been reviewed making emphasis on sample preparation requirements needed in each case. Finally, the main conclusions and future prospects in this field are presented.  相似文献   

7.
This review covers recent advances of capillary electrophoresis (CE) in pharmaceutical analysis. The principle, instrumentation, and conventional modes of CE are briefly discussed. Advances in the different CE techniques (non-aqueous CE, microemulsion electrokinetic chromatography, capillary isotachophoresis, capillary electrochromatography, and immunoaffinity CE), detection techniques (mass spectrometry, light-emitting diode, fluorescence, chemiluminescence, and contactless conductivity), on-line sample pretreatment (flow injection) and chiral separation are described. Applications of CE to assay of active pharmaceutical ingredients (APIs), drug impurity testing, chiral drug separation, and determination of APIs in biological fluids published from 2008 to 2009 are tabulated.  相似文献   

8.
Recent advances in amino acid analysis by CE   总被引:1,自引:0,他引:1  
This paper describes a number of articles that have been published on amino acid (AA) analysis using CE during the period from June 2005 to May 2007. This review article follows the format of the previous articles of Smith (Electrophoresis 1999, 20, 3078-3083), Prata et al.. (Electrophoresis 2001, 22, 4129-4138), and Poinsot et al.. (Electrophoresis 2003, 24, 4047-4062 and Electrophoresis 2006, 27, 176-194). Several new developments in AA analysis with CE are reported describing the use of laser-emitting diodes for LIF, MS, and chips. In addition, we describe articles concerning clinical studies and neuroclinical applications.  相似文献   

9.
Kostal V  Arriaga EA 《Electrophoresis》2008,29(12):2578-2586
This review covers research papers published in the years 2005-2007 that describe the application of capillary electrophoresis to the analysis of biological particles such as whole cells, subcellular organelles, viruses and microorganisms.  相似文献   

10.
Recent advances in capillary electrophoresis methods for food analysis   总被引:2,自引:0,他引:2  
Frazier RA 《Electrophoresis》2001,22(19):4197-4206
This review article addresses recent advances in the analysis of foods and food components by capillary electrophoresis (CE). CE has found application to a number of important areas of food analysis, including quantitative chemical analysis of food additives, biochemical analysis of protein composition, and others. The speed, resolution and simplicity of CE, combined with low operating costs, make the technique an attractive option for the development of improved methods of food analysis for the new millennium.  相似文献   

11.
Recent advances in nonaqueous capillary electrophoresis   总被引:3,自引:0,他引:3  
Riekkola ML 《Electrophoresis》2002,23(22-23):3865-3883
Nonaqueous capillary electrophoresis is undergoing rapid development. The scope of the investigations has clearly expanded, covering both basic studies and analytical applications. This review provides a comprehensive overview at the current status of the technique. Special attention is given to theoretical, methodological, and technical challenges, and the achievements of capillary electrophoresis in nonaqueous media are demonstrated with reference to recent applications.  相似文献   

12.
Recent advances in affinity capillary electrophoresis   总被引:2,自引:0,他引:2  
Use of the specificity of (bio)interactions can effectively overcome the selectivity limitation faced in capillary electrophoresis (CE), and the resulting technique usually is referred to as affinity capillary electrophoresis (ACE). Despite the high selectivity of ACE, several important problems still need to be addressed. A major issue in all CE separations, including ACE, is the concentration detection limit. Using UV detection, this is usually in the order of 10(-6) M whereas laser-induced fluorescence (LIF) detection can provide detection limits down to the sub-10(-10) M range. However, a marked disadvantage of LIF is that labeling of the analytes is usually required, which might change the interaction behavior of the solutes under investigation. Additionally, labeling reactions at sub-10(-10) M concentration levels are certainly not trivial and often difficult to perform quantitatively. Alternative and universal detection approaches, particularly mass spectrometric (MS) detection, look very promising but (A) CE-MS techniques are still far from routine application. Important future progress in sensitive detection strategies is likely to increase the use of ACE in the future.  相似文献   

13.
The current status of high-performance capillary electrophoresis as an analytical separation method for proteins, peptides and amino acids is assessed. Recent advances in suppressing the effects of electroosmotic flow and irreversible adsorption of proteins at the capillary wall are reviewed, together with procedures for optimal separations of peptides and amino acids. The detection aspects emphasize the role of laser-induced fluorescence and capillary electrophoresis/mass spectrometry in high-sensitivity measurements.  相似文献   

14.
Scriba GK 《Electrophoresis》2003,24(22-23):4063-4077
The present review summarizes peptide enantioseparations by capillary electrophoresis with the focus on recent developments. These include the application of new chiral selectors and systematic studies involving series of di- and tripeptides with either common features or with a variety of structures. One section emphasizes mechanistic aspects of the migration order of the enantiomers in cyclodextrin-assisted chiral separations with respect to the complexation constants and the mobilities of the transient diastereomeric complexes. In addition, short paragraphs on the application of chiral capillary electrophoresis to the determination of the stereochemical purity of peptidomimetics and on chiral separations of peptides by capillary electrochromatography have also been included.  相似文献   

15.
16.
毛细管电泳在手性化合物分离分析中的研究进展   总被引:1,自引:0,他引:1  
刘明霞  李向军  白玉  刘虎威 《色谱》2020,38(3):317-323
手性化合物的对映异构体往往表现出不同的生理活性,因此建立手性化合物的有效分离分析方法具有重要意义。毛细管电泳(CE)是一种分离效率高、分析速度快、样品用量少、分离模式灵活多样的分离分析方法,在手性化合物的分离和检测领域应用广泛。该文主要综述了2017~2019年CE在手性分离分析方面的最新进展,并对其未来的发展趋势进行了展望。  相似文献   

17.
This article highlights recent methodological developments in the on-line concentration and separation of amino acids and their enantiomers using capillary electrophoresis. Sections are dedicated to recent contributions to on-line concentration strategies such as field-amplified sample stacking, large-volume sample stacking, dynamic pH junction, transient isotachophoresis, sweeping, and the combination of two methods. The main applications, advantages, and limitations of these procedures in the biological, food, and pharmaceutical fields are addressed. Comprehensive tables listing on-line techniques for the concentration and separation of amino acids and their enantiomers, categorized by the stacking strategies used, background electrolytes, sample matrix, limit of detection, and enhancement factor, are provided.
Figure
Capillary electrophoretic preconcentration techniques for amino acids analysis  相似文献   

18.
CE is gaining great popularity as a well‐established separation technique for many fields such as pharmaceutical research, clinical application, environmental monitoring, and food analysis, owing to its high resolving power, rapidity, and small amount of samples and reagents required. However, the sensitivity in CE analysis is still considered as being inferior to that in HPLC analysis. Diverse enrichment methods and techniques have been increasingly developed for overcoming this issue. In this review, we summarize the recent advances in enrichment techniques containing off‐line preconcentration (sample preparation) and on‐line concentration (sample stacking) to enhancing sensitivity in CE for trace analysis over the last 5 years. Some relatively new cleanup and preconcentration methods involving the use of dispersive liquid–liquid microextraction, supercritical fluid extraction, matrix solid‐phase dispersion, etc., and the continued use and improvement of conventional SPE, have been comprehensively reviewed and proved effective preconcentration alternatives for liquid, semisolid, and solid samples. As for CE on‐line stacking, we give an overview of field amplication, sweeping, pH regulation, and transient isotachophoresis, and the coupling of multiple modes. Moreover, some limitations and comparisons related to such methods/techniques are also discussed. Finally, the combined use of various enrichment techniques and some significant attempts are proposed to further promote analytical merits in CE.  相似文献   

19.
A number of significant improvements in the electrophoretic performance and design of DNA sequencing devices have culminated in the introduction of truly industrial grade production scale instruments. These instruments have been the workhorses behind the massive increase in genomic sequencing data available in public and private databases. We highlight the recent progress in aspects of capillary electrophoresis (CE) that has enabled these achievements. In addition, we summarize recent developments in the use of microfabricated devices for DNA sequencing that promise to bring the next leap in productivity.  相似文献   

20.
Frazier RA  Papadopoulou A 《Electrophoresis》2003,24(22-23):4095-4105
This article reviews recent developments in the application of capillary electrophoresis (CE) for the analysis of foods and food components. CE has been applied to a number of important areas of food analysis and is fast becoming an established technique within food analytical and research laboratories. Papers are reviewed that were published during the two years to date following the previous review (Electrophoresis 2001, 22, 4197-4206).  相似文献   