首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Effect of sample preparation methods on the matrix-assisted laser desorption/ionization (MALDI) analysis of dispersed polysaccharides is reported. By using the conventional drop-drying method, the measured number-averaged molecular weights were found to differ significantly from the values obtained from gel-permeation chromatography (GPC). These discrepancies were found to increase as the average masses of the polysaccharides increased. To understand the impact of the sample preparation method on the MALDI measurement, a dispersed dextran sample was separated into ten narrow-distribution fractions. Mixtures of different mass fractions were prepared and analyzed by using different mixing and preparation methods. By using the ratio of the signal intensity for the low-mass fraction to that of the high-mass fraction as an indicator, the impact of sample preparation conditions on the enhancement of low-mass components (or suppression of high-mass components) was determined. From the results obtained, it is postulated that the difference in solubilities between the low-mass and high-mass components for dispersed polymers might be large enough to induce an enhancement of low-mass components (or suppression of high-mass components) at the surface of the crystals during sample crystallization in the drop-drying method.  相似文献   

2.
The trend of miniaturization in bioanalytical chemistry is shifting from technical development to practical application. In matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), progress in miniaturizing sample spots has been driven by the needs to increase sensitivity and speed, to interface with other analytical microtechnologies, and to develop miniaturized instrumentation.We review recent developments in miniaturizing sample spots for MALDI-MS. We cover both target modification and microdispensing technologies, and we emphasize the benefits with respect to sensitivity, throughput and automation.We hope that this review will encourage further method development and application of miniaturized sample spots for MALDI-MS, so as to expand applications in analytical chemistry, protein science and molecular biology.  相似文献   

3.
Matrix-assisted laser desorption/ionization (MALDI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) analyses are compared to gain insight into some of the details of sample preparation for MALDI analysis of synthetic polymers. ToF-SIMS imaging of MALDI samples shows segregation of the cationization agent from the matrix crystals. The amount of observed segregation can be controlled by the sample preparation technique. Electrospray sample deposition minimizes segregation. Comparing ToF-SIMS and MALDI mass spectra from the same samples confirms that ToF-SIMS is significantly more surface sensitive than MALDI. This comparison shows that segregation of the oligomers of a polymer sample can occur during MALDI sample preparation. Our data indicate that MALDI is not as sensitive to those species dominating the sample surface as to species better incorporated into the matrix crystals. Finally, we show that matrix-enhanced SIMS can be an effective tool to analyze synthetic polymers, although the sample preparation conditions may be different than those optimized for MALDI.  相似文献   

4.
This study presents matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) as a powerful tool to analyze and characterize oligonucleotides covalently linked to a solid support during their synthesis. The analysis of the fragment ions generated either in negative or positive mode allows direct and easy access to the nucleotide sequence and identification of the internucleosidic linkage. The mechanisms of the fragmentation of the solid-supported oligonucleotides induced by MALDI-TOFMS are discussed. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

5.
The analysis of oligonucleotides using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has led to the investigation of the use of matrix additives (i.e., co-matrices) to help improve the poor spectral quality commonly observed during the analysis of this class of compounds. The use of certain matrix additives in MALDI-MS has been investigated previously, and these additives have been shown to enhance the desorption/ionization efficiency of oligonucleotides during the MALDI experiment. Specifically, amine bases, such as piperidine, imidazole, and triethylamine, have been shown to improve mass spectral quality as assessed by improved molecular ion resolution and increased molecular ion abundance. These improvements occur due to competition between the oligonucleotide and the co-matrix for protons generated during the MALDI event. Co-matrices with proton affinities near or above the proton affinities of the nucleotide residues serve as proton sinks during the desorption/ionization process. In this work, we have investigated the use of polyamines as co-matrices for MALDI mass spectrometric analysis of oligonucleotides. Spermine tetrahydrochloride, spermine, spermidine trihydrochloride, and spermidine were evaluated for their effectiveness at enhancing the mass spectral quality of oligonucleotides analyzed using MALDI-MS. The solution-phase pK( b) values and the gas-phase proton affinities of these polyamines were determined, and it was found that the polyamines appear to be more basic than the monofunctional amines investigated previously. The mass spectral data shows that spermidine and spermine are extremely effective co-matrices, yielding improved molecular ion resolution and molecular ion abundances. The spermine co-matrices are more effective than the spermidine co-matrices, but adduction problems with the spermine co-matrices limits their overall utility. In general, polyamine co-matrices are found to be more effective than monofunctional amine co-matrices at improving the mass spectral data obtained during MALDI-MS of oligonucleotides.  相似文献   

6.
Practical guidelines for the preparation of tissue sections for direct analysis by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry are presented. Techniques for proper sample handling including tissue storage, sectioning and mounting are described. Emphasis is placed on optimizing matrix parameters such as the type of matrix molecule used, matrix concentration, and solvent composition. Several different techniques for matrix application are illustrated. Optimal instrument parameters and the necessity for advanced data analysis approaches with regards to direct tissue analysis are also discussed.  相似文献   

7.
An automated sample preparation for high throughput accurate mass determinations by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed. Sample preparation was performed with an automated workstation and automated mass analyses were performed with a commercial MALDI-TOF mass spectrometer. The method was tested with a 41-sample library. MALDI-TOFMS was found to give the needed sensitivity, accurate mass measurement, and soft ionization necessary for structure confirmation, even of mixtures. A mass accuracy of 5 ppm or less was obtained in over 80% of known compound measurements. A mass accuracy better than 10 ppm was obtained for all measurements of known compounds. Analyses of parallel synthesis products resulted in 77% of the measurements with a mass accuracy of 5 ppm or better.  相似文献   

8.
A novel sample preparation method of matrix-assisted laser desorption/ionization mass spectrometry for polystyrene was reported. Compared to the conventional dried-droplet method, the efficiency of ionization and signal intensity of mass spectra were improved. The mechanism was also analyzed.  相似文献   

9.
The ionization of nucleosides in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was systematically investigated using adenine (A), thymine (T), guanine (G) and cytosine (C) with several common matrices. Experimental results of the protonation and deprotonation of the bases of A, T, G and C in the matrices 2,5-dihydroxybenzoic acid (2,5-DHB), alpha-cyano-4-hydroxycinnamic acid (alpha-CHCA) and 3-hydroxypicolinic acid (3-HPA) provide an insight into the ionization mechanism of oligonucleotides in MALDI. It was found that the low ion signal from DNA in poly-G in MALDI as reported in earlier work could be attributed to the fact that the base of G is difficult to ionize. Our results suggest that the ionization of DNA in MALDI is dominated by the protonation and deprotonation of bases and it is basically independent of the backbone of DNA. Both the protonation and deprotonation are strongly structure dependent. The protonation is dominated by pre-protonation before laser ablation, while the deprotonation is controlled by the thermal reaction.  相似文献   

10.
11.
A mixture of 2',4',6'-trihydroxyacetophenone in acetonitrile and aqueous triammonium citrate solution in a 1:1 molar proportion (0.2 M concentration) was found to be a good matrix for the detection of synthetic oligodeoxynucleotide samples. A high proportion of volatile solvent as well as the high salt content ensure fast co-crystallization of the matrix, co-matrix and analyte molecules. Matrix-assisted laser desorption/ionization (MALDI) mass spectra obtained in negative ion reflectron mode from samples prepared with this protocol show deprotonated molecules [M - H](-), rather than sodium adducts, as the most abundant ions even when up to 50 mM of sodium chloride is present in the sample. The matrix is shown to be effective for low mass modified single nucleotides as well as for longer oligodeoxynucleotides (up to 18mer). Post-source decay (PSD) mass spectra can also be obtained by increasing the laser fluence. Simple sequence information such as the identity and localization of a deleted base or the 5'/3' orientation can then easily be obtained. The calibration method and mass accuracy required are discussed depending on the type of information required.  相似文献   

12.
The susceptibility of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) to the presence of salts in a sample, especially salts of alkali metals, requires careful and often tedious desalting procedures which complicate and slow the throughput of MS-based methods. A novel approach to sample preparation was developed based on the extraction of DNA out of solution onto a solid surface with an attached DNA-binding polymer, such as polyethyleneimine or polyvinylpyrrolidone. The observed binding is strong enough to sustain washing, and, as a result, desalting and concentration can be performed in a single fast step. After DNA has been immobilized on the surface and supernatant solution removed, subsequent addition of MALDI matrix releases material from the surface, which co-crystallizes with matrix. The mass spectrometric analysis is then performed directly from this support. Analysis of oligonucleotides and three-fold multiplexed SNP typing reactions performed by this method shows improved sensitivity and excellent resolution for various DNA fragments, together with high tolerance to various buffer components, such as alkali metals and surfactants. Simplicity and speed make it attractive for high-throughput sample preparation and analysis of oligonucleotide mixtures by MALDI-MS.  相似文献   

13.
Although electrospray sample deposition in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) sample preparation increases the repeatability of both the MALDI signal intensity and the measured molecular mass distribution (MMD), the electrospray sample deposition method may influence the apparent MMD of a synthetic polymer. The MMDs of three polymers of differing thermal stability, polystyrene (PS), poly(ethylene glycol) (PEG), and poly(propylene glycol) (PPG), were studied by MALDI time-of-flight (TOF) MS as the electrospray deposition voltage was varied. The MMDs obtained using the electrospray deposition method were compared with those obtained for hand-spotted samples. No change was observed in the measured polymer MMD when the electrospray deposition voltage was varied in the analysis of PS, but those of PEG and PPG changed at higher electrospray voltages due to increased ion fragmentation. It was also shown that the fragmentation in the hand-spotted samples is dependent on the matrix used in sample preparation.  相似文献   

14.
15.
Here we report the first application of a matrix-assisted laser desorption/ionization (MALDI) triple-quadrupole mass spectrometer for targeted proteomics. Employing an amine-specific isotopic labelling approach, the technique was validated using five randomly selected bovine serum albumin peptides differentially labelled at known ratios. An indirect benefit of the isotopic labelling technique is a significant enhancement of the a1 ion in tandem mass (MS/MS) spectra of all peptides studied. Therefore, the a1 ion was selected as the fragment ion for multiple reaction monitoring (MRM) in all cases, eliminating tedious method development and optimization. Accurate quantification was achieved with an average relative standard deviation (RSD) of 5% (n = 5) and a detection limit of 14 amol. The technique was then applied to validate an important virulence biomarker of the fungal pathogen Candida albicans, which was not accurately quantified using global proteomics experiment employing two-dimensional liquid chromatography/electrospray ionization tandem mass spectrometry (2D-LC/ESI)-MS/MS. Using LC/MALDI-MRM analysis of five tryptic peptides, the protein PHR1 was found to be upregulated in the hyphal (pathogenic) form of C. albicans by a factor of 7.7 +/- 0.8.  相似文献   

16.
We report the development of a solid‐phase proteolytic digestion and continuous deposition microfluidic chip platform for low volume fraction collection and off‐line matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry. Tryptic peptides were formed in an on‐chip bioreactor and continuously deposited onto a MALDI target plate using a motor‐driven xyz stage. The bioreactor consisted of a 4 cm × 200 µm × 50 µm microfluidic channel with covalently immobilized trypsin on an array of 50 µm diameter micropost structures with a 50 µm edge‐to‐edge inter‐post spacing. A 50 µm i.d. capillary tube was directly attached to the end of the bioreactor for continuous sample deposition. The MALDI target plate was modified by spin‐coating a nitrocellulose solution containing a MALDI matrix on the surface prior to effluent deposition. Protein molecular weight standards were used for evaluating the performance of the digestion and continuous deposition system. Serpentine sample traces 200 µm wide were obtained with a 30 fmol/mm quantity deposition rate and a 3.3 nL/mm volumetric deposition rate. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
A method of solvent-free sample preparation is shown to be of universal applicability for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Results obtained were compared with those of traditional solvent-based sample preparation for MALDI-MS in order to demonstrate their similarities with respect to accuracy, sensitivity and resolution for polymers such as polystyrene and poly(methyl methacrylate) in a mass range from 2 to 100 kDa. The results revealed that there is fundamentally no difference in the quality of the obtained mass spectra, and we conclude that the mechanism of desorption and ionization remains unchanged. However, the solvent-free sample preparation turned out to have some advantages over the traditional method in certain cases: quick and easy applicability is shown for polyetherimide avoiding time-consuming optimization procedures. In particular, industrial pigments that are insoluble in common solvents were characterized without interfering signals from fragments. The method even showed improvements with respect to reproducibility and mass discrimination effects in comparison to traditional sample preparation. Additionally, this contribution provides new insight regarding the analyte/matrix preorganization for the desorption step which now appears to be independent of crystallinity.  相似文献   

18.
Direct tandem mass spectrometric (MS/MS) analysis of small, singly charged protein ions by tandem time-of-flight mass spectrometry (TOFMS) is demonstrated for proteins up to a molecular mass of 12 kDa. The MALDI-generated singly charged precursor ions predominantly yield product ions resulting from metastable fragmentation at aspartyl and prolyl residues. Additional series of C-terminal sequence ions provide in some cases sufficient information for protein identification. The amount of sample required to obtain good quality spectra is in the high femtomolar to low picomolar range. Within this range, MALDI-MS/MS using TOF/TOF trade mark ion optics now provides the opportunity for direct protein identification and partial characterization without prior enzymatic hydrolysis.  相似文献   

19.
20.
5-Methoxysalicylic acid (MSA) is demonstrated to be a useful matrix for matrix-assisted laser desorption/ionization time-of-flight (TOF) mass spectrometry of oligonucleotides, when desorption/ionization without fragmentation is desired. When MSA is combined with the additive spermine, the need for desalting is reduced. The MSA/spermine matrix yields linear TOF mass spectra with improved resolution, less fragmentation, and less intense alkali ion adduct peaks than those spectra obtained using 3-hydroxypicolinic acid and 6-aza-2-thiothymine with spermine or diammonium hydrogen citrate as additives. Instrumental conditions are discussed to improve the spectral resolution, specifically the use of longer delay times in the delayed-extraction ion source.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号