首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC systems to enable the determination of microcontaminants at the 0.02–1 μg L−1 level in 7–50 mL of aqueous sample. The screening was limited to compounds present in at least one heteroatom-selective GC-AED trace above a predetermined concentration level. These compounds were identified by their partial formulae (AED) and the corresponding mass spectra, which were obtained from the GC-MS chromatogram via the retention index concept. The potential of the approach was demonstrated by the identification of target compounds as well as all unknowns present in tap and waste water above the predetermined threshold of 0.05 μg L−1 (tap water) or 0.5 μg L−1 (waste water).  相似文献   

2.
This paper describes the extraction of 49 organophosphorus pesti-cides (OPPs) from water samples using solid-phase microextraction (SPME). Three fibers, including a 15-μm XAD-coated fiber, a 85-μm polyacrylate-coated fiber, and a 30-μm polydimethylsilox-ane-coated fiber (PDMS), were evaluated here. The effects of stirring and the addition of NaCl to the sample were examined for the polyacrylate-coated fiber. The precision of the technique was examined for all three fibers and the extraction kinetics were investigated using the XAD- and polyacrylate-coated fibers. With some exceptions, the XAD- and polyacrylate-coated fibers performed better than the PDMS-coated fiber. The superiority of the XAD-nd polyacrylate-coated fiber. The superiority of the XAD- and polyacrylate-coated fibers over the PDMS-coated fibers can be attribuibuted to the aromatic functionalities of the XAD and the polar functionalities in the polyacrylate. The relatively high percent RSDs indicate that the SPME technique needs to be further refined before it can be used for anything other than screening. A more effective form of agitation than mechanical stirring may be neccessary to reduce variability and achieve a faster equilibrium between the sample and the SPME fiber.  相似文献   

3.
P. Canosa  J.P. Lamas  I. Orriols 《Talanta》2009,79(3):598-24
A novel method for the determination of the miticide bis[tris(2-methyl-2-phenylpropyl)tin] oxide, also known as fenbutatin oxide (FBTO), in agricultural soils is presented. Pressurized liquid extraction (PLE) followed by analyte derivatization and extraction into isooctane was the used sample preparation approach. Selective determination was achieved by gas chromatography with atomic emission detection (GC-AED). Influence of different parameters on the performance of the extraction process is thoroughly discussed; moreover, some relevant aspects related to derivatization, determination and quantification steps are also presented. As regards PLE, the type of solvent and the temperature were the most relevant variables. Under optimized conditions, acetone, without any acidic modifier, was employed as extractant at 80 °C. Cells were pressurized at 1500 psi, and 2 static cycles of 1 min each were applied. Acetone extracts (ca. 25 mL) were concentrated to 1 mL, derivatized with sodium tetraethyl borate (NaBEt4) and the FBTO derivative, resulting from cleavage of the Sn-O-Sn bond followed by ethylation of the hydroxyl fragments, extracted into isooctane and determined by GC-AED. Under final working conditions, the proposed method provided recoveries from 76 to 99% for spiked soil samples, a limit of quantification of 2 ng g−1 and an acceptable precision. Analysis of samples from vineyards sprayed with FBTO, confirmed the persistence of the miticide in soil for more than 1 year after being applied.  相似文献   

4.
Summary On-line solid-phase extraction-gas chromatographyion-trap tandem mass spectrometry (SPE-GC-MS/MS) has been used for the trace-level determination of polar and apolar pesticides. The SPE-GC interface, an Autoloop 2000, was operated at an injection temperature of 90°C which permitted the determination of thermolabile pesticides such as carbofuran and carbaryl. Rectilinear calibration curves were obtained for the analytes tested over a range of 0.1–500 ng L−1, using a sample volume of 10–100 mL for enrichment on an SPE cartridge packed with styrene-divinylbenzene copolymer. The detection limits for the pesticides were in the 0.01–4 ng L−1 range. For a number of pesticides acceptable tandem mass spectra were obtained at levels as low as 0.1 ng L−1 level in real-life water samples. As a demonstration of the applicability of this technique for inorganic anions, bromide and nitrite were converted into 4-bromoacetanilide and 2-phenylphenol, respectively. The reaction products were pooled and subjected to simultaneous analysis by the present method using full-scan mass spectrometric detection. The detection limits were 0.3 and 2 ng L−1, respectively.  相似文献   

5.
Natalia Campillo 《Talanta》2007,71(3):1417-1423
A direct immersion solid-phase microextraction (SPME) procedure was used in combination with capillary gas chromatography with atomic emission detection (GC-AED) for the determination of 10 pesticides (organochlorines, organophosphorus compounds and pyrethrins) in herbal and tea infusions. Ionic strength, sample dilution and time and temperature of the absorption and desorption stages were some of the parameters investigated in order to select the optimum conditions for SPME with a 100 μm PDMS fiber-coating. Element-specific detection and quantification was carried out by monitoring the chlorine (479 nm) and bromine (478 nm) emission lines, which provided nearly specific chromatograms. Calibration was carried out by using a spiked sample infusion. The detection limits varied between 11.9 ng ml−1 for deltamethrin and 0.03 ng ml−1 for p,p′-DDE and p,p′-DDD. The recoveries ranged from 73.5% for deltamethrin to 108.3% for p,p′-DDT in a spiked white tea infusion. Two of the eight samples analyzed contained low levels of some the pesticides considered.  相似文献   

6.
A validated gas chromatographic method for the determination of triclosan in human dental plaque is described. Based on plaque sample weights of 10 mg, the limit of detection (2 × S/N) is 0.5 μg/g. The method is linear (r = 0.9986) from the limit of detection to 50 μg/g. Recoveries from placebos spiked with 2.0, 25, and 50 μg/g of triclosan were 105.6%±7.5%, 107.2%±3.1%, and 99.1%±1.1%, respectively (n = 3 at each level). Twenty replicate preparations and analyses of a homogenized sample, conducted by two operators over the course of 4 days, showed agreement to within 9% RSD. Analyses of dental plaque collected from patients after brushing with dental cream containing triclosan, shows triclosan to be retained in dental plaque at concentrations above the minimum inhibitory concentration (1 μg/g) after 12 h.  相似文献   

7.
固相萃取-气相色谱法检测茶叶中的有机磷农药残留量   总被引:5,自引:0,他引:5  
建立了茶叶中22种有机磷农药的残留量的气相色谱分析方法. 样品用V(乙腈)∶V(丙酮)=4∶1提取, 经Envi-Carb固相小柱净化, 以V(乙腈)∶V(甲苯)=3∶1洗脱, GC-FPD检测, 外标法定量. 在添加0.05~1.0 mg/kg的水平, 22种有机磷的平均回收率在81.3%~107.9%之间, 相对标准偏差在1.1%~8.9%, 该方法的检出限为0.01~0.04 mg/kg. 该方法的灵敏度、准确度和精密度均符合农药残留量测定的技术要求.  相似文献   

8.
This article proposes an alternative method, using cloud-point extraction and gas chromatography, for extraction and determination of disulfoton in water samples. For cloud-point extraction, the nonionic surfactant Triton X-114 was used. Before gas chromatography, a cleanup stage for surfactant removal from the extracts was optimized. Cleanup used two columns, in series, containing silica gel and Florisil, with methanol:hexane (1?:?1) as eluent, resulting in the removal of more than 95% of the Triton X-114. Factors such as ionic strength (>0.5?mol?L?1) and surfactant concentration (1.0% w/v) increased the extraction efficiency of the cloud-point methodology, yielding disulfoton recoveries of almost 100%. Compared with liquid–liquid extraction, the cloud-point methodology was more efficient, with a better detectability, and resulted in a significant reduction in solvent volume.  相似文献   

9.
Summary The use of the solid-phase extraction technique for the rapid sample preparation of organochlorine pesticides is described. Samples were simultaneously extracted, cleaned, and fractionated by the solid-phase extraction method and a further separation and determination of extracted fractions was carried out by gas chromatography with either an electron capture or a Hall electrolytic conductivity detector. The percent recovery of the extracted seven pesticides was compared to that of the conventional liquid-liquid extraction method. The analytical figures of merit., chromatograms, and statistic data are reported. The application of this method was demonstrated by a real fish sample determination with mass spectra for confirmation of Kepone detection.  相似文献   

10.
The elemental responses for a series of alkylated and arylated phosphates evaluated were measured on an atomic emission spectrometric detector. The signals for carbon, hydrogen, chlorine, phosphorus and oxygen were used to determine the specifity of elemental response ratios to a particular compound structure and the dependence of response ratios on the amounts of the analytes. Variations of the response ratios, as well as the accuracy and variations of the stoichiometric values of the calculated empirical formulae, were evaluated. For this purpose, a test mixture with reference compounds was used. Determination of empirical formulae with acceptable errors of a few percent is possible if the calibrating reference substance is closely related — by structure, elemental composition, molecular weight and amount — to the compounds to be identified. Analyte amounts of at least 30 ng are required for efficient calibration.  相似文献   

11.
Summary A fast and simple procedure for the analysis of aqueous samples by on-line membrane disk extraction and capillary gas chromatography (GC) is presented. As an example, organophosphorus pesticides are preconcentrated from aqueous samples on three 0.5 mm thick, 4.2 mm diameter extraction disks. The layers are dried by a stream of nitrogen (10–15 min; ambient temperature). Desorption of the analytes is carried out with ethyl acetate which is directly introduced into a retention gap under partially concurrent solvent evaporation conditions, using an early solvent vapour exit. The final analysis is carried out by GC with thermionic detection. The technique is applied to the determination of a series of organophosphorus pesticides in tap water and water from two European rivers. With a sample volume of only 2.5 ml, detection limits of 10–30 ppt are achieved in tap water and of 50–100 ppt in river water.  相似文献   

12.
Summary Gas chromatography of polychlorinated biphenyls and chlorinated pesticides in water samples has been performed after adsorption from a 50–250 mL sample on to a cartridge containing 100 mg cyanopropyl-bonded porous silica. The PCBs are desorbed with 500 μL ethyl acetate, which is concentrated and analysed by gas chromatography with electron-capture detection (GC-ECD). The average recovery of 1 ppb PCB congeners at from distilled water and from Marta river water is ≥95% (standard deviation ≤2.5). The average recovery of 20 ppb Aroclor 1260 from Marta river water was ≥91% (standard deviation ≤3.5). In the separation of the PCBs from the chlorinated pesticides only aldrin, heptachlor and 4,4′-DDD are adsorbed with the PCBs by the CN Sep-Pak cartridge. The method proposed is rapid, simple and reproducible.  相似文献   

13.
An atomic emission detector for gas chromatography has been developed which is, in principle, capable of detecting selectively any element (except helium) which can elute from a gas chromatographic column. Software methods have been developed so far for 23 elements and on isotope, including all of the organic elements along with mercury, lead, tin, silicon, and deuterium. Element-specific analyses are shown for several petroleum, environmental, and aroma samples. A table for the detector's element-specific detection limits, selectivities, and linear dynamic ranges is given for 12 elements and deuterium.  相似文献   

14.
Natalia Campillo 《Talanta》2010,80(5):1856-1861
A method based on solid-phase microextraction (SPME) followed by gas chromatography with microwave-induced plasma atomic emission detection for determining dimethylselenide (DMSe) and dimethyldiselenide (DMDSe) in milk and milk by-products is proposed. Parameters affecting the SPME, such as sample volume or mass, ionic strength, adsorption and desorption times and temperatures were optimized in the headspace mode. The matrix effect was evaluated for the different samples studied, concluding that standard additions calibration was required for quantification purposes. The detection limits ranged from 70 to 110 pg mL−1 for DMSe and from 80 to 400 pg mL−1 for DMDSe, depending on the sample under analysis. None of the twenty-three samples analyzed contained the studied compounds at concentrations above the corresponding detection limits.  相似文献   

15.
Twenty nine organophosphorus pesticides (OPPs) are identified on a DB-17 capillary column using gas chromatography-flame photometric detection (GC-FPD). An acetone-acetonitrile mixture is used to initially extract OPPs from milk and infant formula samples, followed by partition of the analytes into dichloromethane (DCM). Dichloromethane is removed on a rotary evaporator and the residue taken up in acetonitrile (ACN) for cleanup on a C-18 (octadecylsiloxane bonded silica) (SPE) cartridge. ACN eluate is evaporated under nitrogen and the residue taken up in acetone for GC-FPD determination. Initial studies showed mean recoveries for 28 of 29 OPPs in whole milk fortified at 0.10 ppm ranged between 69 and 99% with a relative standard deviation (RSD) of 1.0–9.7%. Whole/chocolate/skim-milk and four infant formula products fortified at 0.02 ppm gave mean recoveries of 64–103% with RSDs between 1.9 and 20.9% for 24 of 29 OPPs. Excluding skim milk, recoveries for Dichlorvos, Methamidophos, Mevinphos E, and Acephate ranged between 47 and 89%. Sample extracts were extremely clean and posed no difficulty to the GC system. The procedure is faster and less costly than Association of Official Analytical Chemists (AOAC) procedures and allows for determination of a broad spectrum of OPPs.  相似文献   

16.
An improved set-up for solid-phase extraction with thermal desorption coupled on-line to gas chromatography (SPETD-GC) is presented. It includes a newly designed liner for a programmable temperature vaporizer (PTV) and an improved water elimination system. The SPETD procedure now includes a washing step with HPLC-grade water to prevent degradation of analytes due to interaction with remaining sample constituents. The system was used to analyze surface and tap water samples over a 4-month period. No decrease of chromatographic or trace-enrichment performance was observed, and a liner packed with Tenax GR could be used for at least 150 analyses. The SPETD module was coupled to GC with ion-trap detection for mass spectrometric (MS) and MS/MS detection. The linearity and repeatability of the procedure for several pesticides which were tested in the 0.5–10 μg/1 range were fully satisfactory (1 μg/1, RSD range 5–11%; n = 5). When using sample volumes of 0.1 ml only, detection limits were as low as 0. 1-0.2 μg/1. As an example, the confirmation and quantification of a suspected pesticide in a real-life sample using electron impact and positive chemical ionization in both the MS and MS/MS mode is shown.  相似文献   

17.
Capillary GC coupled to an atomic emission detector (AED) provides a powerful new hyphenated technique for the separation and characterization of complex mixtures and compounds. The AED provides simultaneous and truly specific multi-element detection. The specificity of detection reduces the need for the complex sample pretreatment procedures which are necessary to reduce the interference from co-eluted substances which is experienced with detectors such as the FID and the ECD. A range of environmentally significant problems has been studied, including PCB analysis, the characterization of the reaction products of a novel waste treatment process, and the profiling of sulfur-containing species formed by the pyrolysis of various types of coal.  相似文献   

18.
The extraction of six tetraalkyltin and seven ionic organotin compounds from spiked topsoil samples with supercritical carbon dioxide and carbon dioxide modified with 5 percent methanol was investigated. Analysis of the soil extracts was performed by gas chromatography with atomic emission detection. Retention times, minimum detectable concentrations, and detector linear ranges are included for nine organotin compounds (seven of the nine compounds were derivatized with n-pentylmagnesium bromide prior to gas chromatographic analysis). A 23 factorial experimental design was used to study the effect of three variables (pressure, temperature, and extraction time) on compound recovery. The results indicate that the tetraalkyltin compounds are extracted from topsoil samples with recoveries ranging from 90 to 110 percent. Recoveries for the ionic organotin compounds ranged from 50 to 75 percent for trimethyltin chloride, triethyltin bromide, and tributyltin iodide; they were below 20 percent for dimethyltin dichloride, dibutyltin dichloride, diphenyltin dichloride, and butyltin trichloride. When sodium diethyldithiocarbamate was added to the soil samples prior to extraction, followed by extraction with carbon dioxide modified with 5 percent methanol, recoveries ranged from 70 to 90 percent for trimethyltin chloride, triethyltin bromide, dimethyltin dichloride, tributyltin iodide, and dibutyltin dichloride; recoveries were approximately 40 percent for butyltin trichloride and diphenyltin dichloride.  相似文献   

19.
20.
Environmental applications of capillary gas chromatography coupled with atomic emission derection (GC-AED) have been reviewed with emphasis on both the commercial and laboratory-built systems. Attention was focused on (1) element-selective detection of non-metallic as well as metallic pollutants, (2) identification of contaminants, and (3) sample preparation considerations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号