首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A HPLC method has been developed for the direct assay of fleroxacin in serum, without previous extraction. Serum samples, after the addition of sodium dodecylsulfate (0.5%), were injected directly into an LC Hisep column. The mobile phase consisted of acetonitrile, water and triethylamine in a per cent volume ratio 18:80:2. The pH of the mobile phase was adjusted to 6.50 with the addition of phosphoric acid. The drug was detected fluorometrically at lambda (ex )=280 nm and lambda (em )=450 nm . The linear concentration range of fleroxacin was between 0.01 and 2.0mg/l with a detection limit of 1ng/ml.  相似文献   

2.
3.
4.
An assay using high-performance liquid chromatography has been developed for the determination of bromazepam in plasma. After a single-step extraction from basified samples with dichloromethane, using decarboxyloflazepate as an internal standard, samples were analysed using a reversed-phase Nova Pak 5-microns column with a mobile phase of methanol - phosphate buffer (60 + 40) adjusted to pH 7.6. The drugs were detected at 239 nm and the limit of detection was found to be 3 micrograms l-1 for bromazepam. The method is simple, rapid and sensitive and permits bromazepam levels in clinical and pharmacokinetic studies to be monitored.  相似文献   

5.
6.
7.
A simple and sensitive method for determination of benzodiazepines in plasma has been developed using high-performance liquid chromatography in a reverse-phase mode. The method is illustrated by application to plasma samples containing diazepam and N-desmethyldiazepam at concentrations which would be encountered during therapy, with limits of detection of 10 ng/ml and 2 ng/ml for diazepam and N-desmethyldiazepam, respectively.  相似文献   

8.
9.
10.
Summary A high performance liquid chromatographic method for the determination of flecainide in serum has been developed. The analysis is performed on a microparticulate silica column. The eluate is monitored by fluorescence detection at an excitation wavelength of 300nm and an emission wavelength of 370nm. No sources of interference were identified and a coefficient of variation of less than 8% was observed on repeated flecainide determinations. The method has a good reproducibility, specificity and accuracy, and can be applied in therapeutic drug monitoring of flecainide in patients.  相似文献   

11.
Ambroxol has been determined in biological fluids using a rapid and sensitive high-performance liquid chromatographic method. The samples prepared from plasma by liquid-liquid extraction were analysed on reversed-phase silica gel by competing-ion chromatography with ultraviolet detection. The method was applied to the determination of ambroxol levels in twelve healthy volunteers after oral administration of 90 mg of ambroxol in tablets of Mucosolvan and Ambrosan.  相似文献   

12.
13.
A new method is described for the determination of submicromolar concentrations of 5-bromodeoxyuridine in human plasma. Sample pretreatment involves cold methanol deproteinization, freezing-thawing and lyophilization. The sample is then analysed by reversed-phase high-performance liquid chromatography. This method is very reproducible and has a detection limit of 0.1 microgram/ml (0.32.10(-6) M). Comparison with other procedures indicates that the method is advantageous as regards sensitivity and specificity and can be readily applied in clinical pharmacological investigations.  相似文献   

14.
A sensitive and precise high-performance liquid chromatographic procedure has been developed for the measurement of tiagabine concentrations in human plasma. Isolation of tiagabine and the internal standard was achieved using solid-phase extraction on disposable C8 columns. Separation was performed on a C18 analytical column using a mobile phase containing sodium octanesulfonate. The effluent was monitored with coulometric electrochemical detection at ca. + 0.76 V. The workup procedure recovered more than 95% of tiagabine from plasma. Standard curves were linear over the concentration range 0-500 ng/ml. The precision of the method was good: coefficients of variation were typically less than 5% for concentrations as low as 8 ng/ml and although they were higher at concentrations less than 8 ng/ml, they remained within acceptable limits (less than 17%) for concentrations as low as the limit of quantitation (2 ng/ml using a l-ml plasma sample). The stability of tiagabine in plasma was excellent, with no evidence of degradation after 23 h at room temperature or 2 months at -20 degrees C.  相似文献   

15.
A selective and sensitive high-performance liquid chromatographic method for determination of intact glibenclamide in human plasma or urine has been developed. With glibornuride as internal standard, acid-buffered plasma or urine was extracted with benzene. The organic layer was evaporated and the residue was dissolved in equilibrated mobile phase (acetonitrile-phosphate buffer 0.01 M pH 3.5, 50:50). An aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column, and quantitation was achieved by monitoring the ultraviolet absorbance at 225 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents could be noted. The utility of the method was demonstrated by analysing glibenclamide in samples from diabetic subjects on therapeutic doses of the drug.  相似文献   

16.
17.
A high-performance liquid chromatographic assay for determination of cefonicid concentrations in human plasma and urine samples has been developed using cefazolin as an internal standard. For the analysis of plasma samples two calibration curves were utilized covering the cefonicid concentration ranges of 0.05-1.0 microgram/ml and 1.0-50.0 micrograms/ml, respectively. Coefficients of variation of 7.4% or less were obtained for cefonicid concentrations of 0.05-50.0 micrograms/ml. Mean bias was +6.0% at 0.05 micrograms/ml cefonicid and between -2.1% and +1.6% for 1.0-50.0 micrograms/ml cefonicid. Plasma samples containing 30 ng/ml cefonicid could be well distinguished from blank plasma samples. Urine samples were analysed by using a calibration curve for cefonicid concentrations between 1.0 and 50.0 micrograms/ml. ranged from 8.6% at a cefonicid concentration of 1.0 microgram/ml to 0.5% at 50.0 micrograms/ml with a mean bias between -3.0% and +0.3%.  相似文献   

18.
19.
Summary The purpose of this study was to develop a columnswitching HPLC method for the determination of meropenem in plasma. This method showed excellent precision and accuracy with good sensitivity and speed. The total analysis time per sample was less than 20 min and the mean coefficients of variation for intra- and inter-assay were less than 4.0%. The method has been successfully applied to plasma samples from rats receiving an intraperitoneal injection of meropenem.  相似文献   

20.
A sensitive analysis of pentaerythritol in plasma has been devised, based on the formation or its tetra-p-methoxybenzoate derivative and high-performance liquid chromatography employing an ultraviolet photometric detector. The method permits analysis of pentaerythritol in the ppm range.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号