首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
In this study we compare on-line gel permeation chromatography (GPC) electrospray ionization (ESI) time-of-flight (TOF) mass spectrometry (MS) to automated GPC matrix assisted laser desorption ionization (MALDI) TOF MS for poly (dimethylsiloxane) (PDMS) analysis. Average mass values for a hydroxyl-terminated PDMS (OH-PDMS) sample were obtained and compared to traditional GPC that was calibrated with narrow polystyrene standards, by direct ESI and MALDI MS analysis, by a summation of mass spectra of all GPC fractions, and also by the recalibration method determined by both mass spectrometric methods. Quantitatively, the difference noted here between these hyphenated techniques is that GPC-ESI-TOF MS effectively reports the low-mass oligomers and underestimates the high-mass oligomers, while GPC-MALDI-TOF MS effectively reports the high-mass oligomers and underestimates the low-mass oligomers. In the GPC-ESI-TOF MS experiments, ion current suppression was observed in the high molecular weight region. The suppression effect was confirmed by repeatable sample runs and by injecting different PDMS samples. Higher chromatographic resolution was observed for GPC-ESI-TOF MS compared to GPC-MALDI-TOF MS. In fact, truly mono-disperse oligomers were observed in the low molecular weight range from GPC-ESI MS experiments.  相似文献   

2.
Three sample preparation strategies commonly employed in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOFMS) of whole bacterial cells were investigated for the detection of high mass signals; these included the dried droplet, the seed-layer/two-layer, and the bottom-layer methods. Different sample preparation approaches favoured the detection of high- or low-mass proteins. The low-mass peaks were best detected using the bottom-layer method. By contrast, the dried droplet method using a solvent with higher water content, and hence effecting a slower crystallization process, gave the best results for the detection of high-mass signals. Signals up to m/z 158 000 could be detected with this methodology for Bacillus sphaericus. Sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE) analysis of the same extracts used for MALDI-TOFMS showed bands in the molecular weight range in which high-mass peaks were observed in MALDI-MS, suggesting that the high-mass signals are not polymeric adducts of low-mass protein monomers. In addition, one of the high molecular weight proteins (approximately 126 kDa) was putatively identified as an S-layer protein by an in-gel tryptic digest. The bacterial samples spotted on the target wells for MALDI-TOFMS, using the different sample preparation strategies, were examined under a scanning electron microscope and differences were observed between the different strategies, suggesting that the nature of the crystals and the distribution of the analytes amidst the crystals could influence the spectral pattern observed in MALDI-TOFMS of whole bacterial cells. Finally, evidence is presented to indicate that, although the determinants are intact cells, cell lysis occurs both before and during the MALDI process.  相似文献   

3.
This paper focuses on the development of MALDI sample preparation protocols for the analysis of a bioactive beta-(1 --> 3) polysaccharide, i.e. Curdlan. The crude Curdlan sample was first separated into a low molecular weight water-soluble portion and a high molecular weight water-insoluble portion. The water-soluble portion was analyzed using a standard MALDI sample preparation method developed for dextran analysis. Two low-mass (<4000 Da) polysaccharide distributions differing by 16 Da were observed. For the analysis of the water-insoluble portion, several sample preparation protocols were evaluated using GPC-fractionated samples. A sample preparation method based on the deposition of the analyte solution with a mixture of 2,5-dihydroxybenzoic acid (DHB) and 3-aminoquinoline (3AQ) matrices in dimethyl sulfoxide (DMSO) at elevated temperature of 70 degrees C was found to reliably produce good MALDI spectra. MALDI analysis of the water-insoluble Curdlan portion gave number-average (Mn) and weight-average (Mw) molecular weights and polydispersity of 8000 Da, 8700 Da, and 1.10, respectively.  相似文献   

4.
Despite the advantages of simplicity and high-throughput detection that matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has over other methods, quantitative analysis of low-molecular-weight analyte is hampered by interference from matrix-derived background noise and signal fluctuation due to the inhomogeneous MALDI sample surface. Taking advantage of improved sample homogeneity through matrix-conjugated magnetic nanoparticles (matrix@MNP) and the seed-layer method, we report a new strategy for the rapid identification and quantification of drugs in urine samples, using morphine and 7-aminoflunitrazepam (7-aminoFM2) as model compounds. To our knowledge, this is the first attempt using the seed-layer method for small molecule analysis. By applying the proposed seed-layer method, which was specifically optimized for the 2,5-dihydroxybenzoic acid@MNP (DHB@MNP) matrix, homogeneous sample crystallization examined by microscopy analysis was obtained that generated reproducible MALDI signals (RSD<10.0%). For urine sample analysis, simple liquid-liquid extraction as a sample pretreatment step effectively reduced the ion suppression effect caused by the endogenous components in urine; good recoveries (82-90%) were obtained with a small ion suppression effect (<14% of signal decrease). This newly developed method demonstrated good quantitation linearity over a range of 50-2000 ng mL(-1) (R(2)>0.996) with reduced signal variation (RSD<10.0%). The detection limit is 30 ng mL(-1) with good precision (intra-day, 2.0-9.3%; inter-day, 5.0-10.0%) and accuracy (intra-day, 95.0-106.0%; inter-day, 103.0-115.5%). The nanoparticle-assisted MALDI-TOF MS combined with seed-layer surface preparation provides a rapid, efficient and accurate platform for the quantification of small molecules in urine samples.  相似文献   

5.
The combination of microscope mode matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) with protein identification methodology: the molecular scanner, was explored. The molecular scanner approach provides improvement of sensitivity of detection and identification of high-mass proteins in microscope mode IMS. The methodology was tested on protein distributions obtained after separation by sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE). High-quality, high-spatial-resolution ion images were recorded on a TRIFT-II ion microscope after gold coating of the MALDI sample preparation on the poly(vinylidenedifluoride) capture membranes. The sensitivity of the combined method is estimated to be 5 pmol. The minimum amount of sample consumed, needed for identification, was estimated to be better than 100 fmol. Software tools were developed to analyze the spectral data and to generate broad mass range and single molecular component microscope mode ion images and single mass-to-charge ratio microprobe mode images.  相似文献   

6.
Protein profiling of human serum by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is potentially a new diagnostic tool for early detection of human diseases, including cancer. Sample preparation is a key issue in MALDI MS and the analysis of complex samples such as serum requires optimized, reproducible methods for handling and deposition of protein samples. Data acquisition in MALDI MS is also a critical issue, since heterogeneity of sample deposits leads to attenuation of ion signals in MALDI MS. In order to improve the robustness and reproducibility of MALDI MS for serum protein profiling we investigated a range of sample preparation techniques and developed a statistical method based on repeated analyses for evaluation of protein-profiling performance of MALDI MS. Two different solid-phase extraction (SPE) methods were investigated, namely custom-made microcolumns and commercially available magnetic beads. Using these two methods, nineteen different sample preparation methods for serum profiling by MALDI MS were systematically tested with regard to matrix selection, stationary phase, selectivity, and reproducibility. Microcolumns were tested with regard to chromatographic properties; reversed phase (C8, C18, SDB-XC), ion-exchange (anion, weak cation, mixed-phase (SDB-RPS)) and magnetic beads were tested with regard to chromatographic properties; reversed phase (C8) or affinity chromatography (Cu-IMAC). The reproducibility of each sample preparation method was determined by enumeration and analysis of protein signals that were detected in at least six out of nine spectra obtained by three triplicate analyses of one serum sample.A candidate for best overall performance as evaluated by the number of peaks generated and the reproducibility of mass spectra was found among the tested methods. Up to 418 reproducible peaks were detected in one cancer serum sample. These protein peaks can be part of a possible diagnostic profile, suggesting that this sample preparation method and data acquisition approach is suitable for large-scale analysis of serum samples for protein profiling.  相似文献   

7.
Sodium dodecyl sulfate (SDS), an anionic surfactant, is widely used in peptide and protein sample preparation. When the sample is analyzed by matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS), this surfactant can often cause signal suppression. We have previously reported an on‐probe sample preparation method using a suspension of anion‐exchange silica gel and sinapinic acid (i.e., gel‐SA suspension) as a matrix, thereby greatly improving the MALDI signal detection of the protein solutions containing SDS. In this study, we found that a certain amount of SDS enhanced the MALDI signal intensity for protein samples. This effect was also observed when using sodium decyl sulfate and sodium tetradecyl sulfate instead of SDS. Furthermore, this on‐probe sample preparation method using both SDS and the gel‐SA suspension improved the detection limit of protein samples in the MALDI‐MS analysis by about ten‐fold as compared to that of protein samples without SDS and the gel‐SA suspension. This method can be applied not only to the MALDI‐MS analysis of samples containing SDS, but also to the examination of proteins at femtomole levels or insoluble proteins such as membrane proteins. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
A direct sample fraction deposition method was developed for off-line size-exclusion chromatography (SEC)/matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. By using electrospray, the SEC eluent, together with a suitable matrix solution added coaxially, was directly deposited on the MALDI plate. Owing to the formation of very small droplets in electrospray, solvent evaporation is much faster. The fractionation volume in narrow-bore SEC, which can directly be collected in one MALDI spot, can easily be optimized in the range of a few microlitres. In addition, fairly homogeneous sample spots were obtained. The possible influence of composition variation of the SEC effluent on the analytical results using direct fraction deposition was investigated; no substantial effects were observed. The applicability of the method was demonstrated by characterizing a broad poly(methyl methacrylate) sample. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

9.
The size-exclusion chromatography (SEC) of acetone-soluble, pyridine-soluble and pyridine-insoluble fractions of a coal tar pitch indicates a bimodal distribution in each fraction. The proportion of high-mass material excluded from the SEC column porosity increases with solvent polarity. The polymer calibration of SEC shows the mass range of the small molecules to be from approximately 100 u to approximately 6000 u, with the mass range of the large excluded molecules above 200 000 u and up to several million u. In contrast, matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) shows a similar low-mass range of ion abundances (< m/z 6000), but with a smaller range of high-mass ion abundances, from approximately m/z 10 000 to 100 000. The large molecules may have three-dimensional structures to allow molecules of relatively low mass to behave as if they are of large size in SEC. Laser desorption mass spectrometry of the acetone- and pyridine-soluble fractions produced molecular ions of polycyclic aromatics that can be related to the known compositions from gas chromatography (GC) mass spectrometry. The experimental conditions used to generate the bimodal distribution by MALDI-MS involve reducing the ion signal intensities to avoid overload of the detector and enable detection of the high-mass ions, by reducing the high-mass detector voltage (i.e. sensitivity) and increasing the laser power.  相似文献   

10.
A new method of matrix-assisted laser desorption/ionization (MALDI) sample preparation using a dual-spray electrospray deposition system is demonstrated and employed for the investigation of gas-phase cationization reactions in the MALDI plume. The dual-spray electrospray system is found to increase the homogeneity of the sample similarly to that of a conventional single-spray electrospray system. The dual-spray electrospray system allows for intimate mixing of separately prepared sample components and results in improved quantitative results. The development of this device also leads to the possibility of mixing sample components prepared in different solvents without the need to be concerned with solvent miscibility.  相似文献   

11.
In matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI TOF MS), analyte signals can be substantially suppressed by other compounds in the sample. In this technical note, we describe a modified thin‐layer sample preparation method that significantly reduces the analyte suppression effect (ASE). In our method, analytes are deposited on top of the surface of matrix preloaded on the MALDI plate. To prevent embedding of analyte into the matrix crystals, the sample solution were prepared without matrix and efforts were taken not to re‐dissolve the preloaded matrix. The results with model mixtures of peptides, synthetic polymers and lipids show that detection of analyte ions, which were completely suppressed using the conventional dried‐droplet method, could be effectively recovered by using our method. Our findings suggest that the incorporation of analytes in the matrix crystals has an important contributory effect on ASE. By reducing ASE, our method should be useful for the direct MALDI MS analysis of multicomponent mixtures. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
A glass-chip-based sample preparation method for matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analysis of tryptic digests of proteins and intact cells is described. A MALDI matrix, 2,5-dihydroxybenzoic acid (2,5-DHB), was hybridized with sol-gels to generate a sol-gel-derived material. Taking advantage of the characteristics of sol-gels, the sol-gel-derived material readily adhered to the surface of a glass chip through covalent bonding. Only one step of sample preparation, deposition of the sample solution on the glass chip, was required before MALDI-MS analysis. Because 2,5-DHB was homogeneously dispersed on the sol-gel network structure, good spot-to-spot reproducibility was obtained in MALDI analysis using this approach and the analyte signals were uniform throughout the chip. The modified glass chips were robust and effective for at least 1 week. This glass-chip-based matrix preparation method provides a straightforward approach to developing techniques for analyzing the on-chip enzymatic digestion of proteins and intact cells of microorganisms. Cytochrome C and Escherichia coli were used as analytes to demonstrate the feasibility of this approach. The products of the on-chip enzymatic digests were identified through protein database searches.  相似文献   

13.
This paper focuses on the development of methodology based on MALDI-TOF mass spectrometry for evaluation of molecular weight profile of the water-insoluble portion of an extracellular polysaccharide, i.e. Curdlan. As previously demonstrated, MALDI analysis of water-insoluble Curdlan fraction gave number-average and weight-average molecular weights of 8000 and 8700 Da, respectively [T.W.D. Chan, K.Y. Tang, Rapid Commun. Mass Spectrom. 17 (2003) 887]. To validate the MALDI determined molecular weight information, several additional analytical schemes were used to analysis the water-insoluble Curdlan fraction. In all cases, the water-insoluble Curdlan sample was fractionated by gel permeation chromatography (GPC) using Sephadex G-75 column. The of low-mass and narrow distributed polysaccharide fractions were obtained by MALDI-MS. Good linearity was found in the calibration plot constructed from the measured -values and the corresponding elution time/volume. The relative quantity of various fractionated samples was then measured using three different approaches. These include (a) direct refractometric analysis; (b) UV-vis absorption analysis of the Aniline Blue stained sample; and (c) GC-MS analysis of the hydrolyzed and TMS-derivatized sample. Using results obtained from theses quantification methods and the correlation function between the GPC retention time and , the MW and MWD of water-insoluble Curdlan were obtained. Our results demonstrated that the previous use of MALDI methods for measuring and polydispersity (PD) of water-insoluble Curdlan (with and without GPC fractionation) were unreliable. However, by standardizing the narrow distributed polysaccharides using MALDI-MS method, reliable molecular weight information for dispersed polysaccharides could be obtained. The and PD of the water-insoluble Curdlan were found to be 22,000, 31,500 Da and 1.40, respectively.  相似文献   

14.
Chemical cross-linking in combination with high-mass MALDI mass spectrometry allows for the rapid identification of interactions and determination of the complex stoichiometry of noncovalent protein–protein interactions. As the molecular weight of these complexes increases, the fraction of multiply charged species typically increases. In the case of homomeric complexes, signals from multiply charged multimers overlap with singly charged subunits. Remarkably, spectra recorded in negative ion mode show lower abundances of multiply charged species, lower background, higher reproducibility, and, thus, overall cleaner spectra compared with positive ion mode spectra. In this work, a dedicated high-mass detector was applied for measuring high-mass proteins (up to 200 kDa) by negative ion mode MALDI-MS. The influences of sample preparation and instrumental parameters were carefully investigated. Relative signal integrals of multiply charged anions were relatively independent of any of the examined parameters and could thus be approximated easily for the spectra of cross-linked complexes. For example, the fraction of doubly charged anions signals overlapping with the signals of singly charged subunits could be more precisely estimated than in positive ion mode. Sinapinic acid was found to be an excellent matrix for the analysis of proteins and cross-linked protein complexes in both ion modes. Our results suggest that negative ion mode data of chemically cross-linked protein complexes are complementary to positive ion mode data and can in some cases represent the solution phase situation better than positive ion mode.  相似文献   

15.
A limitation of any current approach using solvent-free MALDI mass spectrometry is that only one sample at a time can be prepared and transferred to the MALDI-plate. For this reason, multiple-sample preparation approaches for solvent-free MALDI MS analysis of synthetic polymers were developed that are simple and practical. One approach multiplexed sample preparation by simultaneously preparing multiple samples. With this approach, as many as 384 samples could be prepared by addition of analyte, matrix, salt, and 1-mm metal beads to each well of a 384-well disposable bacti plate, capping the plate with the lid and homogenizing all samples simultaneously using a common laboratory vortex device. Besides the time savings achieved by a single vortex step for multiple samples, an additional advantage of this method relative to previously reported solvent-free preparation methods is that the mixing volume per sample is reduced, which allows a reduction in the amount of analyte required. This method, however, still requires the transfer of each homogenized sample to the MALDI plate for subsequent analysis. Here we report a novel approach that combines multiple simultaneous solvent-free sample preparation with automatic sample transfer to the MALDI target plate. This approach reduces the possibility of cross-contamination, the amount of sample and matrix consumed for an analysis, and the time required for preparation of multiple samples. These methods were shown to provide high-quality mass spectra for various synthetic polymer standards with M(n) values to 10 kDa. The methods are efficient in that small sample amounts are required, the sample/salt/matrix ratio is not critical, and the time necessary to achieve sufficient homogenization of multiple samples is less than 5 min.  相似文献   

16.
A refined sample preparation procedure for matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) was developed for the evaluation of the degree of substitution (DS) in partially depolymerised carboxymethyl cellulose (CMC). By adding ammonium sulphate to the sample mixture prior to the analysis, good quality mass spectra could be acquired. The usual time-consuming search for 'sweet-spots' at the crystalline rim of the MALDI target spot was also avoided. This quality improvement made it possible to investigate whether various positions on the target spot generated mass spectra in which the measured DS varied. The accuracy and reproducibility of the sample preparation procedure were tested by applying it on three commercial CMCs. The study shows that the DS values that were calculated from the spectra acquired from the centre region of the MALDI target spot were in better agreement with the DS provided by the supplier than were the values obtained from the large crystals at the target spot rim. This observation could be one reasonable explanation for the higher DS values reported in other publications. By applying our refined MALDI sample preparation procedure DS values that were in good agreement with the values provided by the manufacturer could be obtained. This indicates that MALDI-TOFMS of partially depolymerised CMCs can be used for an estimation of the DS as a complement to the more established methods, e.g. NMR, titrimetry, and chromatographic techniques.  相似文献   

17.
Residual acrylamide can cause severe suppression of signal intensity during matrix-assisted laser desorption/ionization (MALDI) peptide mass mapping experiments. This suppression phenomenon can compromise the ability to detect low picomole and subpicomolar amounts of peptides extracted from two-dimensional gels. A rapid and simple method that exploits the use of pipette tips incorporating C18 packing materials for the enhancement of MALDI signal intensity is presented. The utility of the method is demonstrated with peptide solutions incorporating residual acrylamide and/or gel monomer components.  相似文献   

18.
A variety of derivatized fullerenes have been studied by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Of particular emphasis has been the evaluation of a recently introduced solvent-free sample/target preparation method. Solvent-free MALDI is particularly valuable in overcoming adverse solvent-related effects, such as insolubility and/or degradation of the sample. The method was applied to fullerene derivatives susceptible to decomposition under insufficiently "soft" MALDI conditions. Analytes included the hydrofullerene: C(60)H(36), fluorofullerenes: C(60)F(x) where x = 18, 36, 46, 48 and C(70)F(x) where x = 54, 56, methano-bridged amphiphilic ligand adducts to C(60) and the [4 + 2] cycloadduct of tetracene to C(60). The new solvent-free sample preparation is established as an exceedingly valuable addition to the repertoire of preparation protocols within MALDI. The MALDI mass spectra were of very high quality throughout, providing a testimony that "soft" MALDI conditions could be achieved. Using the [4 + 2] cycloadduct of tetracene to C(60) as the model analyte for direct comparison with solvent-based MALDI, the solvent-free approach led to less fragmentation and more abundant analyte ions. Applying solvent-free sample preparation, different matrix compounds have been examined for use in the MALDI of derivatized fullerenes, including sulfur, tetracyanoquinodimethane (TCNQ), 9-nitroanthracene (9-NA) and trans-2-[3-(4-tert-butylphenyl)-2-methyl-2- propenylidene]malononitrile (DCTB). DCTB was confirmed as the best performing matrix, reducing unwanted decomposition and suppression effects.  相似文献   

19.
Although electrospray sample deposition in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) sample preparation increases the repeatability of both the MALDI signal intensity and the measured molecular mass distribution (MMD), the electrospray sample deposition method may influence the apparent MMD of a synthetic polymer. The MMDs of three polymers of differing thermal stability, polystyrene (PS), poly(ethylene glycol) (PEG), and poly(propylene glycol) (PPG), were studied by MALDI time-of-flight (TOF) MS as the electrospray deposition voltage was varied. The MMDs obtained using the electrospray deposition method were compared with those obtained for hand-spotted samples. No change was observed in the measured polymer MMD when the electrospray deposition voltage was varied in the analysis of PS, but those of PEG and PPG changed at higher electrospray voltages due to increased ion fragmentation. It was also shown that the fragmentation in the hand-spotted samples is dependent on the matrix used in sample preparation.  相似文献   

20.
Nanodiscs have become a leading technology to solubilize membrane proteins for biophysical, enzymatic, and structural investigations. Nanodiscs are nanoscale, discoidal lipid bilayers surrounded by an amphipathic membrane scaffold protein (MSP) belt. A variety of analytical tools has been applied to membrane proteins in nanodiscs, including several recent mass spectrometry studies. Mass spectrometry of full-length proteins is an important technique for analyzing protein modifications, for structural studies, and for identification of proteins present in binding assays. However, traditional matrix-assisted laser desorption/ionization-time-of-flight (MALDI-TOF) mass spectrometry methods for analyzing full-length membrane proteins solubilized in nanodiscs are limited by strong signal from the MSP belt and weak signal from the membrane protein inside the nanodisc. Herein, we show that an optimized ultra-thin layer MALDI sample preparation technique dramatically enhances the membrane protein signal and nearly completely eliminates the MSP signal. First-shot MALDI and MALDI imaging are used to characterize the spots formed by the ultra-thin layer method. Furthermore, the membrane protein enhancement and MSP suppression are shown to be independent of the type of membrane protein and are applicable to mixtures of membrane proteins in nanodiscs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号